Compressive Strength of Cylindrical Concrete Specimens


Test Standard: CSA A23.2:19-9C
Client: ONTrack Alliance
Project: CA-WSP-201-11216-02 / 21488014 - Union Station
Element: Area D, 300 Slab-BC01
External ID: USEP-CON-240131-02 Report Number: GAL00365-24

Minimum Strength 35 MPa at 28 Days


Batching Date: 01/31/2024 Time: 15:41 Air Temp. During Pour (°C): 5.0
Sampling Date: 01/31/2024 Time: 16:48 Concrete Temp. During Pour (°C): 20.5
Supplier: CRHCA Concrete Specified Slump (mm): 120 To 180
Concrete Mix ID: S355L410 Measured Slump (mm): 135
Delivery Ticket No.: 24924423 Specified Air Content (%): NA To NA
Truck No.: 1843 Measured Air Content (%): NA
Load No.: 1 Water Added on Site: NA
Contractor: NA Type of Admixtures: Super P
Departure From Site: 02/01/2024 Time: 12:00 Nominal Aggregate Size (mm): 14
Received in Lab: 02/01/2024 Time: 13:00 Plastic Density (kg/m³): NA

Test Specimen
Cast by: Zeel /Aditya Cast Time: 16:55 Lab Number: GAL24-00312
Total Number: 7 Mold Type: Plastic 102mm x 201mm Curing Location: On site in WSP curing box with max/min.
Initial Curing Temp. (°C): Min 19 Max 22 Self Consolidating Concrete (SCC Only) Spec.Slump Flow NA to NA
Non-Standard Curing VSI Value NA Slump Flow NA
NA
Conditions VSI Values (As per CSA A23.2-19C) T50 cm Time NA

Results
Curing
Age of test Avg. Hardened Cylinder
Condition Avg. Length Type of
Cylinder ID Date Tested Tested By (days) 'x' if Diameter Mass (g) Density Compressive
(Standard or (mm) Fracture
Hold (mm) (kg/m³) Strength (MPa)
Field)
A 02/07/2024 Saleh, Abu 7 Standard 101.5 200.0 3981 2460 1 25.8
B 02/28/2024 Saleh, Abu 28 Standard 101.5 200.0 3958 2450 1 35.1
C 02/28/2024 Saleh, Abu 28 Standard 101.5 200.0 3943 2440 1 35.0
D 03/27/2024 56 Standard 101.5 200.0 3963 2450
E 02/05/2024 Saleh, Abu 5 Field 101.5 200.0 3975 2460 1 25.2
F 02/05/2024 Saleh, Abu 5 Field 101.5 200.0 3980 2460 1 26.7
G 02/06/2024 Saleh, Abu 6 Field 101.5 200.0 3975 2460 1 27.3

Average Strength at: 28 Days: 35.1

Type of fracture (As per CSA A23.2-9C)


1. 2. 3. 4. 5. 6.
Cones Cone Columnar Diagonal Side Similar to
on both on one vertical fracture with fracture type 5 with
ends end cracking no cracking at top / pointed
through ends bottom end(s)

Lab Reporting Comments / Deviations


RFT# 00301
General Comments

Amir Ahsan
Reviewed By: ... Title: ...

Signature:

Notice: The test data given herein pertain to the sample provided and may not be applicable to other samples or to material from earlier or subsequent production.
Reporting of these results constitutes a testing service only. Engineering interpretation and advice may be provided upon written request.