1 Product description
DA 100B/150B pad cooling is used in connection with SKOV Combi-Tunnel and Tunnel systems. The cooling
takes place when the air is directed through the pads which are kept constantly moist by recirculating water.
The air passes through these pads and is cooled when absorbing water vapour.
SKOV supplies a complete pad cooling system for cooling pads. The pad cooling system is flexible and can
easily be adapted to the building in question.
2 Product survey
2.1 DA 150B pad cooling
DA 150B pad cooling
437773 DA 150B pad cool basic 6m 1x230V 50Hz
437774 DA 150B pad cool basic 6m 1x230V 60Hz
437759 DA 150B pad cool basic 6m 3X230/400V60Hz
Basic 6 m is a complete pad cooling system for 6 meter, i.e. supply
unit, middle element and end kit.
Pads must be ordered separately.
437783 DA 150B pad cool basic 6m ex pump
Basic 6 m is a pad cooling system for 6 meter, i.e. supply unit,
middle element and end kit.
The supply unit is without pump.
Pads must be ordered separately.
3 Technical data
DA 100B/150B pump
Electric 437371 437370 437375 437374
Supply voltage [V] 1x230 (± 10 %) 1x230 (± 10 %) 1x230 (± 10 %) 3 x 230/400 (± 10 %)
Operational voltage [V AC] 220-240 220-240 220-240 220-240/380-420
Supply frequency [Hz] 50 60 50 60
Performance [m3/h] 18 18 9 18
Power input P1 [kW] 0.69 0.69 0.35 0.68
Power output P2 [kW] 0.45 0.45 0.18 0.45
Current [A] 3.2 3.0 1.95 1.9/1.1
Capacitor [μF] 12 12 6 -
Environment
Max. ambient temperature [°C] 40 40 40 40
Max. liquid temperature [°C] 60 60 60 60
pH- range 6–9 6–9 6-9 6-9
Protection class IP 55 IP 55 IP 55 IP 55
Class of insulation B B B B
Mechanics
Suction/discharge [mm] 50 50 50 50
Weight [kg] 7.6 7.6 6.5 9.3
Total water supply to the system 2.5 m3/h (air speed 1.5 m/s).
Total water supply to the system 3.5 m3/h (air speed 2.0 m/s).