Basics Applies Manning's formula to analyze the normal flow condition, and
applies Froude Number Fr = 1.0 to determine the critical flow condition.
Design Info Provides recommended Manning's n values for low-flow section and overbanks in composite channels.
Acknowledgements: This spreadsheet was originally designed by the Denver Urban Drainage and Flood Control District (UDFCD)
and has been modified by the City of Springfield to reflect local criteria and policies with the permission
of the UDFCD. The original UDFCD spreadsheet development team was comprised of:
Dr. James C.Y. Guo, P.E.
Professor, Department of Civil Engineering
University of Colorado at Denver
Ken A. MacKenzie, P.E.
Urban Drainage and Flood Control District
Wright Water Engineers, Inc. (WWE)
Denver, Colorado
Modifications to the spreadsheet to reflect City of Springfield criteria and policies were made by WWE with
consultation and peer review by the City of Springfield, MO.
Comments? Direct all comments regarding this spreadsheet workbook to: Todd Wagner E-Mail
twagner@springfieldmo.gov
Revisions? Check for revised versions of this or any other workbook at: Downloads
http://www.ci.springfield.mo.us/egov/publicworks/storm_water/manual.html
Maximum Allowable Longitudinal Slope Smax = ft/ft (based on Q25, nmin, & channel lining)
User-Defined Longitudinal Slope Suser = ft/ft (min of 0.004 to prevent ponding)
Drop Height per 100 ft D= ft/ 100 ft
2-Year Discharge
(using Q2 and nmax)
2-Year Flow Depth Y= ft
2-Year Flow Velocity Vmin= fps
2-Year Top Width T= ft
2-Year Flow Area A= sq ft
2-Year Froude Number Fr =
2-Year Wetted Perimeter P= ft
2-Year Hydarulic Radius R= ft
Design Discharge
(using Qd and navg)
Design Discharge Flow Depth YD = ft
Design Discharge Flow Velocity VD = fps
Design Discharge Top Width TD = ft
Design Discharge Flow Area AD = sq ft
Design Discharge Froude Number Fr D=
Design Discharge Wetted Perimeter PD = ft
Design Discharge Hydarulic Radius RD= ft
51
52
53
9
10 Design Information (Input)
11 Design discharge Q= cfs
12 Bottom width B= ft
13 Side slope Z= ft/ft
14 Channel slope So = ft/ft
15 Channel Manning's n (Minimum) n-min =
16
17 Y/B Ratio (Calculated)
18 Flow depth to width ratio (Y/B) Y* =
19 Value of k = (1+z^2)^0.5 k=
20 Wetted perimeter (P/B) P* =
21 Top width (T/B) T* =
22 Flow area (A/B^2) A* =
23 Max. Froude number without roll waves F* =
24 Limiting discharge parameter Q* =
25 Max. discharge without roll waves Q-limit = cfs
26 Calculated discharge in channel (check) Q-design = cfs
27
28 Roll Wave Height (Calculated)
29 Limiting flow condition at section 1 (upstream of the jump)
30 Limiting Froude number (F*) F1 =
31 Normal depth upstream of the jump = Y*B Y1= ft
32 Depth to the centroid of A1 = 0.5(Y1) Y1-bar= ft
33 Flow area upstream of the jump = A*B^2 A1 = sq ft
34 Flow velocity upstream of the jump = Q/A1 V1 = fps
35 Required freeboard w/o roll waves= 2+0.025*V1*Y1^0.33 Fb = ft
36 Pulsating flow condition with roll waves at section 2 (downstream of the jump)
37 Froude number for Q-design: F2 =
38 Flow depth downstream of the jump = Y1+h Y2 = ft
39 Depth to the centroid of A2 = 0.5(Y2) Y2-bar= ft
40 Flow area downstream of the jump A2 = sq ft
41 Calculations of roll waves
42 Wave speed Vw = fps
43 Flow velocity downstream of the jump V2 = fps
44 Wave celerity = Vw-V2 C= fps
45 Calculated roll wave height h= ft
46 Check the solutions by momentum principle
47 Force upstream of jump = ((Vw-V1)*(V2-V1)) Force-u/s = lb's
48 Force downstream of jump = (g*(Y2-bar -A1/A2*Y1-bar)) Force-d/s = lb's
49
50 Required channel depth = max.(Y1+Fb, Y1+h, Y1+0.5') Y-req. = ft
51
52
53
54
55
56
57
58
59
60