You are on page 1of 20

VIR

Valduggia (VC)
Italy

VIR Foundry &


Plastic division
Valduggia (VC)
V IR S.p.A. was established in Italy in
1971 by Savino Rizzio and is now an
Italy
international company with offices in 3
continents: in Europe, with its historical
headquarters in the town of Valduggia,
Northern Italy (with 3 separate sites : the
production, the warehouse and the foun-
dry together with the plastic division); in
North America with Red-White Valve
VIR Warehouse
Corp.; in Asia with its plant in Taizhou and
Valduggia (VC)
Italy its sales office in Shanghai, and in the
Middle East with the Dubai office and
warehouse.
More than 40 years of presence in the
market, together with the creation of a
new logistic centre in the town of Valdug-
gia in 2001, have made the VIR Group an
extremely competitive company, close to
Red-White Valve Corp. its customers' needs and able to handle
Lake Forest, CA short-time deliveries and shipping, even
USA
of small quantities.

VIR ME VIR VIR Taizhou


International DWC LLC Trading Shanghai Manufacturing Co
Dubai Shanghai Taizhou
UAE China China

2
Via Circonvallazione, 10 ®
13018 Valduggia (VC), Italy
Tel: +39 0163 47891
Fax: +39 0163 47895
www.vironline.com

Ductile iron Lug butterfly valve

Lengths according to EN558-1 series 20 (ex DIN3202 K1)


Design according to EN593, testing according to EN12266-1

Available with ductile iron or stainless steel disc


Seat in EPDM (NBR also available for steel disc version)
With lever (lockable in both open and close position) or manual gear
TR CU 010 compliant

PN16

(versions for Max differential pressure 16Bar available)

Working conditions
Suitable for: water, -10°C to +110°C for 4020 and 4025 series
Suitable for: water, -10°C to +90°C for 4329 series
below 0°C only for water with added antifreeze fluids
Not suitable for: gases group 1 & 2, liquids group 1 (Dir. 2014/68/EU)

4320 series 4325 series 4329 series


N. Part
Material Norm Material Norm Material Norm
1 Body D.I. + epoxy GGG40 D.I. + epoxy GGG40 D.I. + epoxy GGG40
2 Disc D.I. Nickel plat. GGG40 Stainless steel SS316 Stainless steel SS316
3 Stem Stainless steel SS416 Stainless steel SS316 Stainless steel SS316
4 Taper pin1 Stainless steel - Stainless steel - Stainless steel -
5 Seat EPDM - EPDM - NBR -
6 Seat support Plastic - Plastic - Plastic -
7 Bushing PTFE - PTFE - PTFE -
8 O-ring EPDM - EPDM - FKM -
9a Lever Cast iron - Cast iron - Cast iron -
9b Manual gear Cast iron - Cast iron - Cast iron -
1

A Sezione A-A
8

1
A
181026
Drawings, photos and data contained in this card are provided for information only. VIR reserves the right to change them without notice.
GA GB GC
L HL GA GB GC HG ØG Weight1
DN
[mm] [mm] [mm] [mm] [mm] [mm] [mm] [kg]
032 267 152 153 53 125 229 146 3,5 / 7,6 ØG
040 267 152 153 53 125 229 146 3,8 / 7,9 HG
050 267 194 153 53 125 271 146 5,2 / 9,3
065 267 207 153 53 125 284 146 5,5 / 9,6
080 267 213 153 53 125 290 146 5,9 / 10
100 267 232 153 53 125 309 146 9,3 / 13,4
125 267 245 153 53 125 322 146 12,9 / 17,0
150 267 257 153 53 125 334 146 13,7 / 17,8
200 359 296 236 73 216 442 289 19,5 / 30,5
L
250 359 328 236 73 216 474 289 29,7 / 40,7
300 359 373 231 80 237 521 289 45,2 / 58,2
350 - - 231 80 237 552 289 - / 81,3
400 - - 243 111 319 680 290 - / 138,2 HL
450 - - 243 111 319 702 290 - / 158,7
500 - - 243 111 319 759 290 - / 226,6
600 - - 296 133 385 902 375 - / 315,5
1
Weight for version with lever / weight for version with gear

HA HB HC NxØP ØK L ØF S MxØB ØC Torque Kv Wgt


DN
[mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [Nm] [m3/h] [kg]
032 65 120 32 4xM16 100 33 90 11 4x9 70 10 40 2,6
040 75 120 32 4xM16 110 33 90 11 4x9 70 12 50 2,9
050 76 162 32 4xM16 125 43 90 13 4x9 70 14 99 4,3
065 89 175 32 4xM16 145 46 90 13 4x9 70 20 170 4,6
080 95 181 32 8xM16 160 46 90 13 4x9 70 27 261 5,0
100 114 200 32 8xM16 180 52 90 13 4x9 70 49 519 8,4
125 127 213 32 8xM16 210 56 90 13 4x9 70 80 884 12,0
150 140 225 32 8xM20 240 56 90 13 4x9 70 119 1366 12,8
200 173 260 36 12xM20 295 60 125 14 4x11 102 229 2713 17,5
250 203 292 36 12xM24 355 68 125 14 4x11 102 380 4697 27,7
300 242 337 36 12xM24 410 78 150 20 4x14 125 552 7136 43,2
350 267 368 45 16xM24 470 78 150 20 4x14 125 650 10308 66,3
400 298/3091 400 51 16xM27 525 102 210 20 4x22 165 922 14175 98,2
450 318/3281 422 51 20xM27 585 114 210 20 4x22 165 1194 18774 118,7
500 349/3611 479 64 20xM30 650 127 210 22 4x22 165 1706 24140 171,6
600 410/4591 562 70 20xM33 770 154 210 22 4x22 165 3080 37294 253,5
1
Version for Max differential pressure 10Bar / version for Max differential pressure 16Bar

ØF

HC
S

ISO 5211
connection NxØP HB
MxØB ØK ®

ØC
Q HA
Via Circonvallazione, 10
13018 Valduggia (VC), Italy
L Tel: +39 0163 47891
Fax: +39 0163 47895
www.vironline.com

Drawings, photos and data contained in this card are provided for information only. VIR reserves the right to change them without notice.
Cutter-AQ electric actuators Jackup electric actuators1
DN
230VAC 24VDC 230VAC 24VAC Double eff. Spring ret.
032
040
050
065
080
100
125
150
200
250 on request
300 on request
350 on request
400 on request
450 on request
500 on request on request
600 on request on request on request
1
3 points control versions / 0-10V control versions
2
Pneumatic actuators sized on 6Bar air supply
3
Flange adaptors required
Mounting of proposed actuators may require specific square connection adaptors
Technical description and dimensions of actuators as reported in their specific technical sheets

Via Circonvallazione, 10
13018 Valduggia (VC), Italy
Tel: +39 0163 47891
Fax: +39 0163 47895
www.vironline.com

Drawings, photos and data contained in this card are provided for information only. VIR reserves the right to change them without notice.
Via Circonvallazione, 10 ®
13018 Valduggia (VC), Italy
Tel: +39 0163 47891
Fax: +39 0163 47895
www.vironline.com

Variable orifice cast iron double regulating valve


Flanged PN16 according to EN1092-2 (ex DIN2533)
Lengths according to EN558-1 series 1 (ex DIN3202 F1)

Tolerance on nominal Kv for completely open valve ±5%


With plugged threaded drains (¼" ISO 7/1Rp) for test points
Provided with test points (given unmounted)
TR CU 010 compliant

PN16
Free of CE marking (cat. according to Art. 4.3 Dir. 2014/68/EU)

Working conditions
Suitable for: water, -10°C to +110°C
below 0°C only for water with added antifreeze fluids
over 100°C only for water with added anti-boiling fluids
Not suitable for: gases group 1 & 2, liquids group 1 (Dir. 2014/68/UE)

20
N. Part Material Norm 19
1 Body Cast iron EN-GJL-250 JL1040
18
2 Cone screw Stainless steel A2
3 Balancing cone Composite material - 17
4 Gasket disc EPDM - 16
5 Shutter Composite material -
15
6 Shut./bon. O-ring EPDM -
7 Body/bon. O-ring EPDM - 14
8 Bonnet1 Cast iron EN-GJL-250 JL1040 13
9 Screws Carbon steel 8.8 A2A 12
10 Memory stop DZR Brass EN12164 CW602N
11 Mem. stop O-ring EPDM Perox - 11
12 Washer DZR Brass EN12164 CW602N 10
13 Stem DZR Brass EN12164 CW602N
9
14 Stem O-ring EPDM -
15 Screw Brass2 CW508L 8
16 Bushing O-ring EPDM - 7
17 Bushing DZR Brass EN12164 CW602N 6
18 Handwheel Polyamide3 PA6.6
5 22
19 Handwheel screw Brass4 CW508L
20 Handwheel cap Polyamide PA6.6 4
21 Plug Steel5 C35E 3
22 Test point DZR Brass6 EN12164 CW602N
1
Two-pieces bonnet (screwed) with EPDM gasket for DN65
2 21
1
Two-pieces bonnet with bottom part in ductile iron EN-GJS-500-7 JL1050 and 8.8 A2A steel
1
1
2

5
Caps with carbamide rubber gaskets
6
Test points with EPDM gaskets and polypropylene ties

160202
Drawings, photos and data contained in this card are provided for information only. VIR reserves the right to change them without notice.
ØF ØE NxØD L H ØV Weight Flow range1 ØV
DN
[mm] [mm] [mm] [mm] [mm] [mm] [kg] [l/s]
065 185 145 4x19 290 215 130 13,4 3,02-6,95
080 200 160 8x19 310 220 130 17,8 6,40-15,36 H
100 220 180 8x19 350 240 130 22,7 10,85-26,04
125 250 210 8x19 400 260 130 34,0 16,85-39,75
150 285 240 8x23 480 285 130 48,5 23,71-56,91 ØF ØE
200 340 295 12x23 600 480 310 114,5 41,86-100,47
250 405 355 12x28 730 525 310 159,0 66,58-156,78 NxØD
300 460 410 12x28 850 535 310 210,5 94,16-255,99 L
1
Suggested flow range applicability (BS7350)

If used with measuring manometers different from those proposed by VIR please verify that sensibility of the measuring
device is compatible with indicated minimum flow (see flow measurement paragraph)

Accuracy on nominal Kv
Handwheel Kv [m3/h @ 1bar] 11
position 065 080 100 125 150 200 250 300
1,0 21,9 7,9 9,6 13,0 14,8 38,6 62,3 57,1 10
1,5 26,4 9,9 12,8 17,8 19,1 45,6 73,1 72,2
2,0 31,1 11,8 16,6 23,7 29,7 54,6 87,3 89,8 9
2,5 35,7 13,8 22,9 33,1 51,8 71,2 115,8 110,2
3,0 40,1 16,7 34,0 51,2 83,7 99,9 163,9 140,7 8
3,5 44,4 21,9 50,5 77,0 132,0 148,6 239,2 202,0
4,0 49,3 31,2 71,4 106,5 183,7 216,2 345,3 331,7
Handwheel position
7
4,5 53,2 45,9 90,9 135,7 219,5 283,9 451,4 500,2
5,0 57,5 65,0 107,4 160,9 247,1 341,2 543,3 634,1 6
5,5 64,4 79,5 121,6 182,1 273,3 387,7 622,0 733,2
6,0 71,8 89,3 135,0 201,9 298,2 430,1 694,0 825,1 5
6,5 76,6 96,6 148,1 221,6 321,3 471,7 765,2 922,9
7,0 80,4 102,7 159,9 239,8 342,2 507,6 823,7 1018 4
7,5 84,1 108,2 169,8 255,9 360,7 535,2 876,3 1100
8,0 88,8 113,4 177,9 270,8 376,8 560,8 925,3 1170 3
8,5 - - 184,7 285,1 390,2 590,0 974,4 1230
9,0 - - - - - 619,3 1022 1285 2
9,5 - - - - - 644,9 1068 1340
10,0 - - - - - 667,2 1110 1394 1
10,5 - - - - - 688,4 1150 1449
11,0 - - - - - 710,0 1188 1504 0
0 1 2 3 4 5 6 7 8 9 10 11 12 13
±%
Kv p TP
Q
36 pTP

Formula linking flow Q (in l/s) and


measured at test points (in Low pressure
kPa). Kv depends on handwheel test point
position as indicated on table.
Minimum flow that can be High pressure
measured for each diameter may test point ®
be calculated by using in the
formula minimum that can be
measured by used manometer.
Valves are anyway designed for
best performances when used on Via Circonvallazione, 10
range previously suggested and Q (flow) 13018 Valduggia (VC), Italy
as indicated by BS7350. Tel: +39 0163 47891
Fax: +39 0163 47895
www.vironline.com

Drawings, photos and data contained in this card are provided for information only. VIR reserves the right to change them without notice.
DN65
100 Handwheel
position
1,0
1,5
2,0
2,5
3,0
pTP [kPa]

3,5
10 4,0
4,5
5,0
5,5
6,0
6,5
7,0
7,5
1 8,0
0,1 1 10 100
Flow [l/s]

DN80
100 Handwheel
position
1,0
1,5
2,0
2,5
3,0
pTP [kPa]

3,5
10 4,0
4,5
5,0
5,5
6,0
6,5
7,0
7,5
1 8,0
0,1 1 10 100
Flow [l/s]

DN100
100 Handwheel
position
1,0
1,5
2,0
2,5
3,0
pTP [kPa]

3,5
10 4,0
4,5
®
5,0
5,5
6,0
6,5
7,0 Via Circonvallazione, 10
7,5 13018 Valduggia (VC), Italy
1 Tel: +39 0163 47891
8,5
0,1 1 10 100 Fax: +39 0163 47895
Flow [l/s] www.vironline.com

Drawings, photos and data contained in this card are provided for information only. VIR reserves the right to change them without notice.
DN125
100 Handwheel
position
1,0
1,5
2,0
2,5
3,0
pTP [kPa]

3,5
10 4,0
4,5
5,0
5,5
6,0
6,5
7,0
7,5
8,0
1 8,5
0,1 1 10 100
Flow [l/s]

DN150
100 Handwheel
position
1,0
1,5
2,0
2,5
3,0
pTP [kPa]

3,5
10 4,0
4,5
5,0
5,5
6,0
6,5
7,0
7,5
1 8,5
0,1 1 10 100
Flow [l/s]

DN200
100 Handwheel
position
1,0
1,5
2,0
2,5
3,0
pTP [kPa]

3,5
10 4,0
4,5
5,0 ®
5,5
6,0
7,0
8,0
9,0 Via Circonvallazione, 10
10,0 13018 Valduggia (VC), Italy
1 11,0 Tel: +39 0163 47891
1 10 100 1000 Fax: +39 0163 47895
Flow [l/s] www.vironline.com

Drawings, photos and data contained in this card are provided for information only. VIR reserves the right to change them without notice.
DN250
100 Handwheel
position
1,0
1,5
2,0
2,5
3,0
pTP [kPa]

3,5
10 4,0
4,5
5,0
5,5
6,0
7,0
8,0
9,0
10,0
1 11,0
1 10 100 1000
Flow [l/s]

DN300
100 Handwheel
position
1,0
1,5
2,0
2,5
3,0
pTP [kPa]

3,5
10 4,0
4,5
5,0
5,5
6,0
7,0
8,0
9,0
10,0
1 11,0
1 10 100 1000 ®
Flow [l/s]

Via Circonvallazione, 10
13018 Valduggia (VC), Italy
Tel: +39 0163 47891
Fax: +39 0163 47895
www.vironline.com

Drawings, photos and data contained in this card are provided for information only. VIR reserves the right to change them without notice.
Handwheel Kv [m3/h @ 1bar]
position 065 080 100 125 150 200 250 300
1,0 21,9 7,9 9,6 13,0 14,8 38,6 62,3 57,1
1,5 26,4 9,9 12,8 17,8 19,1 45,6 73,1 72,2
2,0 31,1 11,8 16,6 23,7 29,7 54,6 87,3 89,8
2,5 35,7 13,8 22,9 33,1 51,8 71,2 115,8 110,2
3,0 40,1 16,7 34,0 51,2 83,7 99,9 163,9 140,7
3,5 44,4 21,9 50,5 77,0 132,0 148,6 239,2 202,0
4,0 49,3 31,2 71,4 106,5 183,7 216,2 345,3 331,7
4,5 53,2 45,9 90,9 135,7 219,5 283,9 451,4 500,2
5,0 57,5 65,0 107,4 160,9 247,1 341,2 543,3 634,1
5,5 64,4 79,5 121,6 182,1 273,3 387,7 622,0 733,2
6,0 71,8 89,3 135,0 201,9 298,2 430,1 694,0 825,1
6,5 76,6 96,6 148,1 221,6 321,3 471,7 765,2 922,9
7,0 80,4 102,7 159,9 239,8 342,2 507,6 823,7 1018 Q (flow) p
7,5 84,1 108,2 169,8 255,9 360,7 535,2 876,3 1100 (headloss)
8,0 88,8 113,4 177,9 270,8 376,8 560,8 925,3 1170
8,5 - - 184,7 285,1 390,2 590,0 974,4 1230
9,0 - - - - - 619,3 1022 1285
9,5 - - - - - 644,9 1068 1340
10,0 - - - - - 667,2 1110 1394
10,5 - - - - - 688,4 1150 1449
11,0 - - - - - 710,0 1188 1504
Copy of the table presented in flow measurement paragraph
TP

2
36 Q
p Kv depends on handwheel position as indicated on table.
KV

To obtain the best performances valve must be installed on a pipe with its same
nominal size preceded and followed by straight pipe lengths as per figure
indications.

Min 5xDN
(10xDN if installed
on pump outlet)

Min 2xDN

Via Circonvallazione, 10
13018 Valduggia (VC), Italy
Tel: +39 0163 47891
Fax: +39 0163 47895
www.vironline.com

Drawings, photos and data contained in this card are provided for information only. VIR reserves the right to change them without notice.
Using diagram above, determine the
presetting position of the valve with the given
design flowrate and headloss:
1) draw a straight line joining design flowrate
and design headloss;
2) determine design Kv value as intersection ®
of drawn line and Kv axis;
3) draw a straight horizontal line from
intersection previously identified and the
specific valve DN Axis;
4) intersection determines handwheel Via Circonvallazione, 10
position to use for presetting. 13018 Valduggia (VC), Italy
3
In the example for a design flowrate of 40m /h and
Tel: +39 0163 47891
Fax: +39 0163 47895
determined for a DN125 valve www.vironline.com

Drawings, photos and data contained in this card are provided for information only. VIR reserves the right to change them without notice.
Via Circonvallazione, 10 ®
13018 Valduggia (VC), Italy
Tel: +39 0163 47891
Fax: +39 0163 47895
www.vironline.com

Fixed orifice bronze double regulating valve


Threaded F/F (ISO 228/1 for DN15 and DN20, ISO 7/1 Rp above)
Olive and nut kit (O/N) for European copper tubing (EN1057) on request:
DN15, kit for 15mm pipe
DN20, kit for 22mm pipe
Design according to BS7350
Tolerance on nominal Kvs ±3% (test according to BS7350)
Available in the following versions:
Fig. 9585, with test points
Fig. 9586, with test points (high pressure TP with drain)
TR CU 010 compliant

PN25 (Max 25bar up to 110°C, max 20bar above)


PN16 with O/N kit (Max 16bar up to 30°C, max 5bar at 120°C)
Free of CE marking (cat. according to Art. 4.3 Dir. 2014/68/EU)

Working conditions
Suitable for: water, -10°C to +130°C (120°C with O/N kit)
below 0°C only for water with added antifreeze fluids
over 100°C only for water with added anti-boiling fluids
Not suitable for: gases group 1 & 2, liquids group 1 (Dir. 2014/68/UE)

15
14
13
N. Part Material Norm 12
1 Venturi insert DZR Brass EN12164 CW602N 11
2 Body Bronze EN1982 CB491K 10
3 Balancing cone DZR Brass EN12164 CW602N 9
4 Gasket disc PTFE -
8
5 Disc1 DZR Brass EN12164 CW602N
7
6 Disc O-ring1 EPDM Perox -
7 Disc stem DZR Brass EN12164 CW602N 6
8 Stem O-ring EPDM Perox - 5
9 Union1 DZR Brass EN12165 CW602N 4
10 Stem Brass EN12164 CW617N 3
11 Bonnet DZR Brass EN12164 CW602N
12 Stop spring ring Spring steel -
13 Screw Steel -
14 Handwheel ABS (blue) - For Fig.
15 Nut Zinc plated steel EN10025 Fe42 9585
16 Test point DZR Brass2 EN12164 CW602N
1
Only on DN32, DN40 and DN50
2
Test points with EPDM gaskets and polypropylene ties

2
16
1 For Fig. 9586,
equipped with
TP with drain
Fig. 9315

160323
Drawings, photos and data contained in this card are provided for information only. VIR reserves the right to change them without notice.
H L B ØV I Wgt Flow range
DN G1 H
[mm] [mm] [mm] [mm] [mm] [g] [l/s]
U 015 ½" 103,0 87,82 17,5 70 22 5752 0,017-0,045
L 015 ½" 103,0 87,82 17,5 70 22 5702 0,031-0,074
015 ½" 103,0 87,82 17,5 70 22 5652 0,062-0,1484
020 ¾" 103,0 95,93 19,0 70 22 6403 0,138-0,3254
G
025 1" 103,0 100,0 22,5 70 22 780 0,258-0,6034
032 1¼" 123,3 117,5 24,8 70 22 1270 0,540-1,2504
040 1½" 125,4 127,0 24,8 70 22 1570 0,810-1,8804 B
050 2" 135,6 145,3 29,2 70 22 2180 1,520-3,5104 L
1
ISO 228/1 for DN15 and DN20, ISO7/1 Rp above
2
For olive and nut version length 109,2mm, weight +63g
3
For olive and nut version length 119,1mm, weight +65g
4
Suggested flow range applicability (BS7350).
ØV
If used with measuring manometers different from those proposed by VIR please verify that sensibility of the
measuring device is compatible with indicated minimum flow (see flow measurement paragraph)
I

100,00

U-DN15, Kvs venturi 00,55


10,00
L-DN15, Kvs venturi 01,15
pTP [kPa]

DN15, Kvs venturi 02,80


DN20, Kvs venturi 05,33
DN25, Kvs venturi 09,72
DN32, Kvs venturi 20,25
1,00 DN40, Kvs venturi 30,23
DN50, Kvs venturi 55,07

0,10
0,001 0,010 0,100 1,000 10,000 100,000
Flow [l/s]

Formula linking flow Q (in l/s) and


K vsventuri p TP
Q pTP
measured at test points (in kPa). 36
Minimum flow that can be measured
for each diameter may be calculated
by using in the formula minimum
that can be measured by used High pressure test point
manometer. Low pressure test point ®
Valves are anyway designed for best
performances when used on range
previously suggested and as indicated
by BS7350.

Q (flow) Via Circonvallazione, 10


13018 Valduggia (VC), Italy
Tel: +39 0163 47891
Fax: +39 0163 47895
www.vironline.com

Drawings, photos and data contained in this card are provided for information only. VIR reserves the right to change them without notice.
Handwheel Kv [m3/h @ 1bar]
position U 015 L 015 015 020 025 032 040 050
0,5 0,115 0,115 0,26 0,39 1,38 2,60 2,92 5,26
0,7 0,142 0,143 0,33 0,48 1,63 3,01 3,39 6,74
1,0 0,188 0,195 0,45 0,60 1,94 3,36 3,99 8,89
1,3 0,233 0,250 0,57 0,74 2,30 3,84 4,51 11,32
1,5 0,268 0,291 0,63 0,85 2,50 4,20 5,06 13,12
1,7 0,298 0,346 0,71 0,95 2,77 4,63 5,80 15,08
2,0 0,348 0,439 0,79 1,09 3,34 5,52 7,59 18,41
2,3 0,390 0,513 0,86 1,24 3,97 6,93 10,09 21,81
2,5 0,419 0,563 0,91 1,37 4,45 8,07 11,90 23,60
2,7 0,438 0,608 1,01 1,58 4,72 9,42 13,55 24,90
3,0 0,463 0,673 1,29 2,06 5,16 11,12 15,66 26,34
3,3 0,484 0,737 1,68 2,66 5,46 12,39 17,40 28,00
3,5 0,493 0,775 1,87 2,97 5,67 13,12 18,19 28,93
3,7 0,502 0,815 1,99 3,20 5,82 13,58 18,78 29,89
4,0 0,516 0,865 2,03 3,50 6,07 13,85 19,27 30,81
4,4 0,515 0,879 2,03 3,57 6,15 - - -

Formula linking flow Q (in l/s) and

Kv depends on handwheel position as


indicated on table.

2
36 Q
p
KV
p
Q (flow)
(headloss)

To obtain the best performances valve must be installed on a pipe with its same
nominal size preceded and followed by straight pipe lengths as per figure
indications.

Min 5xDN
(10xDN if installed ®
on pump outlet)
Min 2xDN

Via Circonvallazione, 10
13018 Valduggia (VC), Italy
Tel: +39 0163 47891
Fax: +39 0163 47895
www.vironline.com

Drawings, photos and data contained in this card are provided for information only. VIR reserves the right to change them without notice.
By using diagram above is possible to
esteem the presetting position of the valve
with given design flowrate and headloss:
1) draw a straight line joining design flowrate
and design headloss;
2) determine design Kv value as intersection ®
of drawn line and Kv axis;
3) draw a straight horizontal line from
intersection previously identified and the
specific valve DN Axis;
4) intersection determines handwheel Via Circonvallazione, 10
position to use for presetting. 13018 Valduggia (VC), Italy
3
In the example for a design flowrate of 2m /h and
Tel: +39 0163 47891
Fax: +39 0163 47895
determined for a DN25 valve www.vironline.com

Drawings, photos and data contained in this card are provided for information only. VIR reserves the right to change them without notice.
Via Circonvallazione, 10 ®
13018 Valduggia (VC), Italy
Tel: +39 0163 47891
Fax: +39 0163 47895
www.vironline.com

Full bore bronze ball valve


Threaded F/F (ISO 228/1)
(available on request with ASME B1.20.1 NPT threads)
Design according to MSS-SP110
Air testing according to EN12266-1
Blow-out proof stem, adjustable packing

CE and TR CU 010 compliant

Working conditions
Suitable for: water, 0°C to +185°C;
Suitable for: air, -10°C to +185°C
Not suitable for: gases and liquids group 1 (Dir. 2014/68/UE)

9
8
N. Part Material Norm 7 alt.
1 Fixed End Bronze EN1982 CB491K
6
2 Stem Brass EN12164 CW617N
3 Ball Chromium pl. Brass EN12165 CW617N 5
4 Seat PTFE -
4
5 Body Bronze EN1982 CB491K
6 Packing ring PTFE - 3
7 Packing nut Brass EN12164 CW617N 2
8 Screw Geomet steel EN10025 Fe42
9 Handle Geomet steel1 EN10025 Fe P11 1
9alt. Butterfly Geomet steel1 EN10025 Fe P11
1
With red PVC cover

A C P HL L HF F Kv Weight HF
DN G
[mm] [mm] [mm] [mm] [mm] [mm] [mm] [m3/h] [g]
010 46 12,5 10 39 81,0 45 52 5,8 139 / 1321
015 ½" 57 15,5 15 54 91,5 54 62 15,7 259 / 2461
020 ¾" 67 16,5 20 58 91,5 58 62 30,8 364 / 3511
025 1" 77 19,5 25 65 126,5 69 83 49,3 597 / 5731 L
032 1¼" 91 21,5 32 71 126,5 75 83 79,0 926 / 9021
040 1½" 103 21,5 40 83 141,5 93 110 125,3 1414 / 13861
050 2" 122 25,0 50 91 141,5 101 110 224,2 2102 / 20741
HL
065 2½" 153 30,0 65 119 281,3 - - 330,2 4366
080 3" 179 34,0 80 131 281,3 - - 419,4 6200
1
Weight for lever handle version / weight for butterfly handle version
G P

C
A 161221
Drawings, photos and data contained in this card are provided for information only. VIR reserves the right to change them without notice.
Via Circonvallazione, 10 ®
13018 Valduggia (VC), Italy
Tel: +39 0163 47891
Fax: +39 0163 47895
www.vironline.com

Cast iron strainer in GG25


Flanged PN16 according to EN1092-2 (ex DIN2533)
Lengths according to EN558-1 series 1 (ex DIN3202 F1)

Steel strainer in SS304 with round holes mesh

With threaded drain (1/2" BSP for all sizes)


TR CU 010 compliant

Free of CE marking (cat. according to Art. 4.3 Dir. 2014/68/EU)

Working conditions
Suitable for: water, 0°C to +110°C
Not suitable for: gases group 1 & 2, liquids group 1 (Dir. 2014/68/UE)

6
N. Part Material Norm
1 Body Cast Iron GG25 5
2 Drain cap Ductile iron GGG40 4
3 Bonnet Cast Iron GG25
4 Gasket Graphite - 3
5 Nuts Carbon steel - 2
6 Strainer Stainless steel SS304
1

ØF ØE S NxØD L H HG ØG Kv Wgt
DN
[mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [m3/h] [kg]
032 140 100 18 4x18 180 111 90 37 20 6,2 L
040 150 110 18 4x18 200 128 100 44 33 7,5 S
050 165 125 18 4x18 230 140 120 54 54 10,8
065 185 145 18 4x18 290 161 130 68 95 15,5 ØD
080 200 160 20 8x18 310 187 150 88 140 20,2
100 220 180 20 8x18 350 215 175 106 201 26,8 ØF ØE
125 250 210 22 8x18 400 249 200 133 340 37,1
150 285 240 22 8x23 480 292 235 158 526 56,1
200 340 295 24 12x23 600 361 290 208 870 90,6 H
250 405 355 30 12x27 730 429 345 258 1260 144,0 HG
ØG
300 460 410 30 12x27 850 492 400 308 1735 185,0
350 520 470 36 16x27 980 595 492 342 - 294,0
400 580 525 38 16x30 1100 673 552 412 - 388,0

160309
Drawings, photos and data contained in this card are provided for information only. VIR reserves the right to change them without notice.
Via Circonvallazione, 10 ®
13018 Valduggia (VC), Italy
Tel: +39 0163 47891
Fax: +39 0163 47895
www.vironline.com

Bronze strainer
Threaded F/F (ISO 228/1)
Stainless steel strainer

TR CU 010 compliant

Free of CE marking (cat. according to Art. 4.3 Dir. 2014/68/EU)

Working conditions
Suitable for: water, 0°C to +150°C
Not suitable for: gases group 1 & 2, liquids group 1 (Dir. 2014/68/UE)

N. Part Material Norm 4


1 Body Bronze EN1982 CB491K 3
3 Strainer Stainless steel AISI 304
4 Gasket Fiber - 2
2 Bonnet Brass EN12165 CW617N 1

A C P H Weight
DN G
[mm] [mm] [mm] [mm] [g]
010 56 10 13 37 178
015 ½" 54 12 12 38 175
H
020 ¾" 67 15 17 43 290
025 1" 79 16 24 53 410
032 1¼" 98 17 30 64 700 G
040 1½" 106 18 35 70 915 P
050 2" 122 20 43 85 1390
065 2½" 147 22 60 122 2800
C
080 3" 165 23 68 140 3725
A
100 4" 221 23 93 175 6860

161111
Drawings, photos and data contained in this card are provided for information only. VIR reserves the right to change them without notice.
Via Circonvallazione, 10 ®
13018 Valduggia (VC), Italy
Tel: +39 0163 47891
Fax: +39 0163 47895
www.vironline.com

ON/OFF linear actuator with threaded connection


M30x1,5 threaded nut with fast connection
With 1m electric wire
Enclosure protection IP54
CE compliant

Power supply 50Hz or 60Hz


Versions for 230VAC or 24V AC/DC available
Normally closed (NC)
Normally open (NO) version available on request
Working temperature: 0°C to +60°C

VIR Code P. supply1 Thrust Stroke Power Trav. time


KA952AT00.800 230VAC 100N 4,0mm 1,0W / 2,0W 2
KA952AT02.800 24V AC/DC 100N 4,0mm 1,0W / 2,0W 2
KA952AT50.800 230VAC 100N 5,0mm 1,0W
KA952AT52.800 24V AC/DC 100N 5,0mm 1,0W
KA952AT05.800 230VAC 125N 6,5mm 1,2W
KA952AT07.800 24V AC/DC 125N 6,5mm 1,2W
1
±10%
2
Type 1 / type 2

NC version (standard)
Stroke
Opened valve

Closed valve
time
Delay Delay
on ON on OFF
ON OFF
Stroke
Opened valve

Closed valve
time
NO version (on request)

170427
Drawings, photos and data contained in this card are provided for information only. VIR reserves the right to change them without notice.
HA HB LA LB Weight HB
VIR Code
[mm] [mm] [mm] [mm] [g]
KA952AT00.800 4,3 57,3 / 54,01 48 44 100 / 1151
KA952AT02.800 4,3 57,3 / 54,01 48 44 100 / 1151
KA952AT50.800 4,3 57,3 48 44 100
HA
KA952AT52.800 4,3 57,3 48 44 100
LA LB
KA952AT05.800 4,3 / 7,52 67,4 / 76,92 48 44 110
KA952AT07.800 4,3 / 7,52 67,4 / 76,92 48 44 110
1
Type 1 / type 2
2
With short nut / with long nut Short Long
nut nut

N Ph
Ref. Designation
N Wiring to neutral
Ph Wiring to phase

VIR Code 9520 series valves 9920 series valves 9700 series valves
KA952AT00.800 L 015, 015, 020 015, H 015, L 020, 020, 025 -
KA952AT02.800 L 015, 015, 020 015, H 015, L 020, 020, 025 -
KA952AT50.800 L 015, 015, 020 015, H 015, L 020, 020, 025 L 015, 015, 020
KA952AT52.800 L 015, 015, 020 015, H 015, L 020, 020, 025 L 015, 015, 020
KA952AT05.800 L 015, 015, 020, 025 H 015, 020, 025 025, 032
KA952AT07.800 L 015, 015, 020, 025 H 015, 020, 025 025, 032