You are on page 1of 12

Pepito Jigs for RC










First Trial Right.

CONFIDENTIAL
After sales Status
➢ Special JIGs

第 Item Description PN Reference Pic Qty Status



次 1
Back cover mylar stick jig
WAA64K0U6002 1 Ready
就 (For battery cover)

事 2
Double-side adhesive stick jig WAA64K0HU002
1 Ready
情 (For Deco)


Pressure Shell Fixture
3 (For deco & battery cover) WAA64K0ME002 1 Ready
First Trial Right.

Adaptor for WAA64HANL001


Ready
4 (For air leak test) WAA64K0VX001 1

CONFIDENTIAL
After sales Status
➢ Generic JIGs (Copy Go play’s JIGs)
Item Description PN Reference Pic Qty Status

第 1 Platform of pressure WAA00002U002 1 Ready




就 2 Weight 1KG
N/A
1 Ready
把 (prepare locally)
事 Manometer N/A
情 3
(GMH3161-13) (prepare locally)
1 Ready

对 USB cable for GMH3161
N/A
4 (prepare locally) 1 Ready
(Greisinger:USB 3100N)
First Trial Right.

5 Fixture for Manometer solution WAA64HANL001 1 Ready

N/A
Blu-Tack (Bostik)
(prepare locally)
7 (For IP68/IP67 general air tightness 1 Ready
(Reusable material)
test jig )

CONFIDENTIAL
Battery-cover-sticker jig introduction(for battery cover)
➢ Jig information
No. Description PN Comment

第 1 back cover mylar stick jig(for battery cover) WAA64K0U6002 Only for pepito

次 * battery-cover-sticker,Pepito,92.36x46.36xWH0.3, BPA64K0006C0
Sticker for below


SEKESUI 5230PCB,zexin operation process

把 ➢ Jig operating process



情 (Sticker*: BPA64K0006C0) Note:
Assemble the TP-LCD-frame part in Take out the TP-LCD-frame

1.The adhesive side faces up;
2. Pay attention to the battery- the right direction and then press the part and then separate it from

对 cover-sticker assembly direction LCD side lightly battery-cover-sticker


First Trial Right.

CONFIDENTIAL
Double-side adhesive stick jig introduction(for deco)
➢ Jig information
No. Description PN Comment
2 Double-side adhesive stick jig(for decoration) WAA64K0HU002 Only for pepito
第 * Decoration, PEPITO,PC,PAINTED GLOSS,BLACK,GREEN,-MATCH BDA64K0A11C0 Component for below


FRONT GLASS (May be updated) operation process


pito-plastic-deco-sticker,Pepito,94.4x48.8xT0.1,TESA sticker for below operation
* 61365/0.1,zexin
BPA64K0021C0
process

就 ➢ Jig operating process (Sticker*:BPA64K0021C0)


把 Decoration*: BDA64K0A11C0

Note: The adhesive
side of plastic-deco-

情 Left Right
sticker faces down



Left Right
First Trial Right.

Note: The decoration


adhesive side faces up Assemble the upper
cover down well

Done

Press down lightly 5


Separate deco from plastic- Take out the plastic-deco-
deco-sticker sticker with deco from jig

CONFIDENTIAL
Pressure Shell Fixture introduction (for deco & battery cover)
➢ Jig information
No. Description PN Time F(kgf) Comment

第 3
Pressure Shell
Fixture
WAA64K0ME002 10s 58.8 Only for Pepito
一 Press platform WAA00002U002 - - For all models



事 ➢ Jig operating process
情 Put the phone on the Jig in the right

做 direction as red frame shown.


(Note: Only the battery-cover side
对 faces up is effective)
Assemble the Jig’s upper cover in
the right direction
First Trial Right.

Time(S) F(Kgf)
10 58.8
The Pepito device with 6
battery-cover & deco
well assembled

CONFIDENTIAL
Air tightness test solution introduction

➢ Air leak test solution (2 solution modes for choose)



一 Working
Using range

Condition
Item Solution Mode Pic Details
就 With liquid
Normal phone* All states phone All phone, watch
(Pepito) (Pepito) and tablet (within 8’)

事 1KG Weight + APK

1 No Yes No No Page 8 & 9


对 2 Manometer + PC program No Yes Yes No Page 10 & 11
First Trial Right.

Note *: “Normal phone” means the device can power on & work with APK.

CONFIDENTIAL
Pepito air leak test after sales
➢ IP68_ Air leak test solution 1 (Internal Manometer)
• Description:
✓Add 1Kg Weight on handset, test the barometer data variation, meaning the leakage from

一 handset inner to outside.
次 • Tools:
就 ✓1KG Weight

事 Download link:

做 https://css.tclmobile.cn/Web_Skill/filelis


t.aspx?s_id=113&b_id=111&model_na
me=PVG100&productname=(pepito+V
ZW)&path=%2fCMS%2fRSH_Manage
%2fUploaded_Images%2f&model_cod
First Trial Right.

e=9265

• Test Steps:
Step1: Seal hole of MIC(2 positions) and test hole by using Blu-Tack or adhesive as below;

Note:
(1) Make sure the device SIM tray is well
assembled ;
(2) Must seal the 3 holes well, otherwise the
test would fail.
Seal holes by 8
Blu-Tack

CONFIDENTIAL
➢ IP68_ Air leak test solution 1 (Internal Manometer)
Step3: Make sure the SIM/SD card tray is well
 Test Steps: assembled, set home button on pepito phone as
Step2: Download “APK” from CCS website and then install it on Pepito phone below method and then put it on a pad on the table
to ensure that the phone is flat.
PC interface
Note: Please set home button on phone as following
method: Settings->Display->Advanced->Activate
“Use Navigation Bar instead of Home Button”
第 Pad sample


就 Whatever the shape
and size should ensure

把 interface
Phone
the phone is balanced
to accept 1kg weight


情 Note: Must ensure that


Power on the touching surface of
the pad is smooth to


avoid scratch

Step4: ①Open the “Barometer” app on the phone; ② Click “”Reset” to clean data; ③ Step5: Test result display
First Trial Right.

Note: Please recollect Blu-Tack and clean the


Click “Reference Read” to begin test;④Check the shown time from 3s to 0s, Once shown device while finish testing
0s, put the 1kg weight on the TP in red circle;⑤Wait for test result about 20s till shown
“Test Finished!”

⑤ ⑤
① ② ③ ④ ④
CONFIDENTIAL
➢ IP68_ Air leak test solution 2 (External Manometer)
• Description:
✓ Measure air pressure variable by Manometer and PC
program;
第 • Tools:
一 ✓ Manometer, (GMH3161);

就 ✓ Test USB cable (USB 3100N);


情 ✓ Inspect program;
做 Download link:
对 https://css.tclmobile.cn/Web_Skill/filelist.aspx?s_id=113&b_id=
111&model_name=PVG100&productname=(pepito+VZW)&pat
First Trial Right.

h=%2fCMS%2fRSH_Manage%2fUploaded_Images%2f&mode
l_code=9265
Assemble
Disassemble
✓ Test fixture;
Note: Need to change Krypton and Goplay’s adaptor for
WAA64HANL001 into Pepito’s (WAA64K0VX001)

The disassembly & assembly adaptor for WAA64HANL001 is


WAA64K0VX001
as below. 10

Remark: Follow Go play or Krypton’s solution


CONFIDENTIAL
Step1: Disassemble the
1 screw in red circle and Step2: Remove the Step3: Assemble the
adaptor as below Pepito’s adaptor as below Step4: Assemble the 5
Loosen the 4 screw in
screws well
blue circle




就 Take out Assemble





对 •Test steps
WAA64K0VX001

✓ Step1,Prepare:
First Trial Right.

A)Connect with test fixture/Cylinder/Manometer/PC

✓ Step 2
A) Turn on switch
B)Pumping air out by Cylinder to STD limitation
C)Turn off tube switch;

✓ Step 3
A) Check the test and result from PC program.
11

Remark: Follow Go play or Krypton’s solution


CONFIDENTIAL





事 Thank you



First Trial Right.

12

CONFIDENTIAL

You might also like