Based on the Platform Geometry, the Enhancement and Cancellation frequencies are
tabulated below. Sample calculation of both frequencies given as follows.
Natural Frequency of the Platform for first three modes shall be 0.685, 0.694, and 0.792 Hz.
Also, COD wave period is 4.543 sec ﴾0.220Hz﴿. Hence the Frequency of Platform & COD wave
frequency does not coincide with the frequencies which leads to cancellation wave frequency.
Cancellation wave period for 0 Degree Direction = √23 / (1.56 x (1.0 − 0.5)
Cancellation wave period for 90 Degree Direction = √21 / (1.56 x 1.0 − 0.5)
Cancellation wave period for Diagonal Direction = √31.14 / (1.56 x 1.0 − 0.5)
Where,