You are on page 1of 8

AKSIJALNI KOMPENZATORI

-KORISTE SE ZA CEVOVODE RELATIVNO MALIH PREČNIKA I PRITISKA

-U OZNACI PROIVOĐAČA, KAO OSNOVNI PODACI MORAJU STAJATI: NAZIVNI PREČNIK (DN),MAX.
AKSIJALNO POMERANJE KOJE PRIMA KOMPENZATOR (∆b) I PRITISAK ZA KOJI SE PREPORUČUJE (PN)

-PREDNOSTI:

 MINIMALNI INSTALACIONI PROSTOR


 NISKA CENA
 LAKO RAZUMEVANJE KOMPENZACIONOG PROBLEMA

-NEDOSTACI:

 FIKSNE TAČKE MORAJU BITI JAKE


 ZA VELIKA AKSIJALNA POMERANJA ,KOD DUGIH CEVOVODA, MORA SE UGRADITI VIŠE KOMPENZATORA

-AKSIJALNI KOMPENZATORI SE MOGU UGRADITI DA APSORBUJU SVA KRETANJA , VIBRACIJE ILI


NEDOSTATKE PRI UGRADNJI KOD PUMPI,MOTORA,KOMPRESORA

1.TERMIČKI PRORAČUN DILATACIJE CEVOVODA

∆total= αt∙∆t∙L [mm]

∆total - UKUPNO TERMIČKO ŠIRENJE CEVOVODA [mm]


αt – KOEFICIJENT TEMPERATURSKE DILATACIJE [1/K]
∆t - RAZLIKA IZMEĐU MAX I MIN TEMPERATURE [K]
L - DUŽINA CEVOVODA IZMEĐU DVE FIKSNE TAČKE [mm]
 Vrednosti αt za neke materijale:

αt [1/K]
čelik 12 ∙ 10⁻⁶
mesing 19 ∙ 10⁻⁶
olovo 28 ∙ 10⁻⁶
cink 39,7 ∙ 10⁻⁶
2.ŠEMA UGRADNJE AKSIJALNOG KOMPENZATORA

3.PRORAČUN "COLD-PULL" DIMENZIJE


 POMERANJE KOMPENZATORA OBIČNO SE IZRAŽAVA KAO ± ∆total/2, kao na slici:
Lb- slobodna dužina kompenzatora [mm]

Linst- ugradna dužina kompenzatora [mm]

Hp- COLD PULL [mm]

Linst= Lb + Hp [mm]

 AKSIJALNI KOMPENZATOR JE NAPRAVLJEN TAKO DA SE JEDNAKO POMERA I U EKSPANZIJI,I U


KOMPRESIJI,(kao što se vidi na predhodnoj slici).
 MEĐUTIM, POSTO JE U PRAKSI VIŠE UOBIČAJENO DA CEVI PROVODE VRUĆE MEDIJE,OBIČNO SE
KOMPENZATORI POSTAVLJAJU DA PRIME EKSTENZIJU CEVI.
 TAKO DA BI SMO MAKSIMALNO ISKORISTILI AKSIJALNO POMERANJE KOMPENZATORA ,TREBA
URADITI “COLD-PULL” PRORAČUN. SA GORNJE SLIKE SLEDI:

t inst −t min
Hp = Δtotal ·0,5 –( t −t ) Δtotal [mm]
max min

 EKSPANZIJA:
t inst −t min
tinst > tmin Hp = Δtotal · ( 0,5 – tmax −t min ) [mm]

tinst = tmin Hp = Δtotal · 0,5 [mm]


t min −t inst
tinst < tmin Hp = Δtotal · ( 0,5 + t −t ) [mm]
max min

 KOMPRESIJA:
t max −t inst
tinst < tmax Hp = Δtotal · ( t −t – 0,5 ) [mm]
max min

tinst = tmax Hp = – 0.5 Δtotal [mm]


t inst −t max
tinst > tmax Hp = – Δtotal · ( t −t + 0,5 ) [mm]
max min
Hp=COLD PULL [mm]

∆total= ukupno termičko širenje cevi [mm]

tinst= ugradna temperatura [ °C ]

Ukupno toplotno širenje cevi mora biti manje ili jednako ukupnom mogućem pomeranju
aksijalnog kompenzatora:

∆total ≤ (±) ∆b
Gde je:

∆total - ukupno toplotno širenje cevi , dobija se proračunom ∆b


- ukupno pomeranje kompenzatora je kataloška vrednost

4.ANALIZA PRORAČUNA
-ANALIZIRAĆEMO DOLE PRIKAZANU ŠEMU:

-PRVO ĆEMO DEFINISATI SREDNJU TEMPERATURU tsr=(tmax+tmin)/2 I POSMATRAĆEMO ŠTA SE


DOGAĐA AKO VREDNOST tINST MENJAMO U GRANICAMA tmax< tinst<tmin
-OČIGLEDNO JE DA ĆE UGRADNA DUŽINA KOMPENZATORA VARIRATI OD MIN DO MAX VREDNOSTI

-UOČAVAMO TRI ZANIMLJIVE TAČNE VREDNOSTI TEMPERATURE UGRADNJE KOMPENZATORA:

A. tinst=tmax POLOŽAJ U KOJEM JE KOMPENZATOR UGRAĐEN JE TAKAV DA JE ON POD KOMPRESIJOM

I Hp= - ∆total/2

B. tinst=tsr KOMPENZATOR SE UGRAĐUJE BEZ NAPREZANJA Hp=0, Linst=Lb

C. tinst=tmin POLOŽAJ U KOJEM JE KOMPENZATOR UGRAĐEN JE TAKAV DA JE ON U EKSTENZIJI

I Hp= ∆total/2
-SADA ĆEMO ANALIZIRATI 4 ZONE I TO:

 ZONA 1 - tinst>tmax , Hp <- ∆total/2 , Linst< Lb


KOMPENZATOR JE UGRAĐEN POD KOMPRESIJOM
 ZONA 2 - tmax>tinst>tsr , - ∆total/2 < Hp < 0 , Linst< Lb
KOMPENZATOR JE UGRAĐEN POD KOMPRESIJOM
 ZONA 3 - tsr>tinst>tmin , 0 < Hp < ∆total/2 , Linst> Lb
KOMPENZATOR JE UGRAĐEN U EKSTENZIJI
 ZONA 4 - tinst<tmin , Hp > ∆total/2 , Linst> Lb
KOMPENZATOR JE UGRAĐEN U EKSTENZIJI

A. B. C.

tinst=tmax tinst=tsr tinst=tmin

tinst>tmax tmax>tinst>tsr tsr>tinst>tmin tinst<tmin


ZONA 1 ZONA 2 ZONA 3 ZONA 4
OBLAST KOMPRESIJE OBLAST EKSTENZIJE

5.ZAKLJUČAK
- IZBOR AKSIJALNOG KOMPENZATORA JE VRLO OSETLJIVA STVAR I DOBRO TREBA VODITI RAČUNA O
IZBORU TEMPERATURA PRI PRORAČUNU! JER MOŽE DA SE DESI SLUČAJ KAO NA SLICI:

-KOD MEDIJA KOJE PROVODE VRELU VODU,KAO ŠTO JE SLUČAJ U JKP“NOVOSADSKATOPLANA”,NAJČEŠĆI


SLUČAJ JE ZONA 3:

 ZONA 3 - tsr>tinst>tmin , 0 < Hp < ∆total/2 , Linst> Lb


KOMPENZATOR JE UGRAĐEN U EKSTENZIJI

Linst= Lb + Hp [mm]

Linst-UGRADNA DUŽINA KOMPENZATORA


t inst −t min
Hp = Δtotal · ( 0,5 – t −t ) – COLD PULL DUŽINA
max min
Lb- SLOBODNA DUŽINA KOMPENZATORA

PRIMER:

-TREBA UGRADITI KOMPENAZATOR NA VRELOVODU :

DN=300 mm p= 12 bar

L = 70 m –DUŽINA CEVOVODA IZMEĐU DVE FIKSNE TAČKE

αt= 12 ∙ 10⁻⁶ [1/K] – CEVOVOD OD ČELIKA

tmax=130 °C , tmin= 0 °C , tinst =10 °C

∆total= αt∙∆t∙L = 12 ∙ 10⁻⁶ ∙ 130 ∙ 70.000 = 109,2 mm (109 mm)


Sad treba da izaberemo aksijalni kompenazator iz kataloga odabranog proizvožača.

Mi ćemo birati iz kataloga DOO ĐURA ĐAKOVIC – S.BROD

USVAJAMO KOMPENZATOR OZNAKE PROIZVOĐAČA ĐURA ĐAKOVIC:

AR/ 16 /300 /125 / N / 1

-PROJEKTOVANI PRITISAK 16 bar

-PROJEKTOVANA TEMPERATURA 300°C

-ISPITNI PRITISAK 25 bar

-Lb= 475 mm ∆b= 125 mm

t inst −t min 10−0


Hp = Δtotal · ( 0,5 – t max −t min
) =109 ∙ (0,5 - 150−0 )= 47,2 mm

Linst= Lb + Hp = 475 + 47,2 = 522,2 mm


PROVERAVAMO 109 mm < 125 mm 12bar<16bar 130°C<300°C

KOMPENZATOR ĆE BITI U EKSTENZIJI

-RASTOJANJE OD FIKSNE TAČKE ĆEMO IZRAČUNATI:

L = 2 ∙ D + ∆/2 =2 ∙ 300 + 109/2 = 601 mm , a max vrednost je :

Lmax=4 ∙ D = 4 ∙ 300 = 1.200 mm


MREŽA JKP“NOVOSADSKA TOPLANA“ :

POTIS tmax= 130 °C

TPV tmax= 90 °C tmin= 0 °C

POVRAT tmax= 70 °C

Temperature ugradnje tinst= 20-40 °C

Zoran Migić,dipl.maš.inž.