Too Much Vibration


SMCS - 1000-035

Probable Causes
z Vibration damper or pulley

z Engine mounts

z Driven equipment

z Misfire, rough operation, or instability

Recommended Repairs
Vibration Damper or Pulley

Inspect the vibration damper for damage. Look for evidence of overheating and leaks. Make sure that
the vibration damper is fastened securely.

Inspect the pulley for good condition and alignment.

Engine Mounts

Inspect the condition of the engine mounts. Look for proper installation. Make sure that the bolts are
secure.

Driven Equipment

Inspect the alignment and the balance of the driven equipment. Inspect the coupling. If necessary,
disconnect the driven equipment and test the engine.

https://sisweb.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/s... 21/09/2009
G3516 Generator Set CSZ00001-UP(SEBP3374 - 29) - Document Structure Page 2 of 2

Misfire or Rough Operation

Refer to Troubleshooting, "Engine Misfires, Runs Rough or Is Unstable".