Mid 014-Cid 0318-Fmi 01
Mid 014-Cid 0318-Fmi 01
Shutdown SIS
Previous Screen
Troubleshooting
G3500 Engines
Media Number -SENR6413-08 Publication Date -01/06/2008 Date Updated -05/06/2008
i02336853
The conditions which generate this code depend on the software in the control module for the Electronic
Ignition System (EIS).
If the date code for the EIS software is earlier than October 1996, the code is activated when the engine
speed is above 500 rpm and the signal from the detonation sensor for the right cylinder bank is below
the normal range.
If the date code for the EIS software is later than September 1996, the code is activated when the engine
speed is above 900 rpm and the signal from the detonation sensor for the right cylinder bank is below
the normal range.
System Response:
The shutdown output is activated. The diagnostic code may be viewed on the Digital Diagnostic Tool
(DDT) or on the Caterpillar Electronic Technician (ET).
Results:
z OK - STOP