You are on page 1of 16

Qualcomm Audio Calibration Tool

v2.8.18
Release Notes
80-VM679-19 A
March 2, 2012

Submit technical questions at:


https://support.cdmatech.com/

Qualcomm Confidential and Proprietary


Restricted Distribution. Not to be distributed to anyone who is not an employee of either Qualcomm or a
subsidiary of Qualcomm without the express approval of Qualcomm’s Configuration Management.

Not to be used, copied, reproduced in whole or in part, nor its contents revealed in any manner to others without the
express written permission of Qualcomm.

Qualcomm reserves the right to make changes to the product(s) or information contained herein without notice. No
liability is assumed for any damages arising directly or indirectly by their use or application. The information
provided in this document is provided on an “as is” basis.

This document contains Qualcomm confidential and proprietary information and must be shredded when discarded.

QUALCOMM is a registered trademark of QUALCOMM Incorporated in the United States and may be registered
in other countries. Other product and brand names may be trademarks or registered trademarks of their respective
owners. CDMA2000 is a registered certification mark of the Telecommunications Industry Association, used under
license. ARM is a registered trademark of ARM Limited. QDSP is a registered trademark of QUALCOMM
Incorporated in the United States and other countries.

This technical data may be subject to U.S. and international export, re-export, or transfer (“export”) laws. Diversion
contrary to U.S. and international law is strictly prohibited.

QUALCOMM Incorporated
5775 Morehouse Drive
San Diego, CA 92121-1714
U.S.A.

Copyright © 2012 QUALCOMM Incorporated.


All rights reserved.
Contents

1 Introduction...................................................................................................... 5
1.1 Purpose.......................................................................................................................... 5
1.2 Requirements ................................................................................................................ 5
1.3 Installation instructions ................................................................................................. 5
1.4 Conventions .................................................................................................................. 5
1.5 References..................................................................................................................... 5
1.6 Technical assistance ...................................................................................................... 6
1.7 Acronyms ...................................................................................................................... 6

2 New Features ................................................................................................... 7

3 Bugs and Limitations ...................................................................................... 8


3.1 Known bugs .................................................................................................................. 8
3.2 Fixed bugs ..................................................................................................................... 8
3.3 Limitations .................................................................................................................. 12

4 QACT Test Notes ........................................................................................... 13

A ACDB Conversion Wizard Support ............................................................. 14

B Test Cases ..................................................................................................... 16

80-VM679-19 A 2 Qualcomm Confidential and Proprietary


MAY CONTAIN U.S. AND INTERNATIONAL EXPORT CONTROLLED INFORMATION
Contents

Tables

Table 1-1 Reference documents and standards .............................................................................. 5


Table 2-1 New features .................................................................................................................. 7
Table 3-1 Fixed bugs ..................................................................................................................... 8
Table B-1 Test cases .................................................................................................................... 16

80-VM679-19 A 3 Qualcomm Confidential and Proprietary


MAY CONTAIN U.S. AND INTERNATIONAL EXPORT CONTROLLED INFORMATION
Revision history

Revision Date Description


A Mar 2012 Initial release

80-VM679-19 A 4 Qualcomm Confidential and Proprietary


MAY CONTAIN U.S. AND INTERNATIONAL EXPORT CONTROLLED INFORMATION
1 1 Introduction

2 1.1 Purpose
3 This document provides information for Qualcomm Audio Calibration Tool v2.8.18.

4 1.2 Requirements
5 This product requires:
6  Windows XP or Windows 7
7  Microsoft .NET 2.0 framework (or greater)

8 1.3 Installation instructions


9 If you received this version of Qualcomm Audio Calibration Tool in a self-extracting Zip file
10 (for example, xxxxx.exe), you can install it as follows:
11 1. Select the Run... option from the Taskbar Start menu
12 2. Type the full path and name of the file, e.g.,:
13

14 C:\DNLOAD\xxxxx.exe
15

16 3. Press the Enter key and follow the prompts.

17 1.4 Conventions
18 Function declarations, function names, type declarations, and code samples appear in a different
19 font, e.g., #include.

20 1.5 References
21 Reference documents, which may include Qualcomm, standards, and resource documents, are
22 listed in Table 1-1. Reference documents that are no longer applicable are deleted from this table;
23 therefore, reference numbers may not be sequential.

24 Table 1-1 Reference documents and standards

Ref. Document

Qualcomm
Q1 Application Note: Software Glossary for Customers CL93-V3077-1
Q2 Qualcomm Audio Calibration Tool v2.x.x User Guide 80-VM407-2

80-VM679-19 A 5 Qualcomm Confidential and Proprietary


MAY CONTAIN U.S. AND INTERNATIONAL EXPORT CONTROLLED INFORMATION
Introduction

1 1.6 Technical assistance


2 For assistance or clarification on information in this guide, submit a case to Qualcomm CDMA
3 Technologies at https://support.cdmatech.com/.
4 If you do not have access to the CDMATech Support Service website, register for access or send
5 email to support.cdmatech@qualcomm.com.

6 1.7 Acronyms
7 For definitions of terms and abbreviations, see [Q1].
8

80-VM679-19 A 6 Qualcomm Confidential and Proprietary


MAY CONTAIN U.S. AND INTERNATIONAL EXPORT CONTROLLED INFORMATION
1 2 New Features

2 Table 2-1 lists the new features in this release.

3 Table 2-1 New features


Index Technology CR New feature description
1. Audio 339780 MSM8930.WP.1.0 ACDB release 1.0
New feature description
Represents the ACDB 1.0 release for MSM8930.WP.1.0. Support is required in QACT for performing
offline/online calibration on 8930 WP.
2. Audio 339747 Support AF Coeffs monitoring view for Fluence v5 and Fluence Pro in RTC
New feature description
QACT support added for AF coeffs monitoring view for Fluence Pro and Fluence v5 RTC.
4

80-VM679-19 A 7 Qualcomm Confidential and Proprietary


MAY CONTAIN U.S. AND INTERNATIONAL EXPORT CONTROLLED INFORMATION
1 3 Bugs and Limitations

2 3.1 Known bugs


3 This section is not applicable to this release.

4 3.2 Fixed bugs


5 Table 3-1 lists the fixed bugs in this release.

6 Table 3-1 Fixed bugs


Impact
Index Technology CR Fixed bug description
category
1. Audio Function/Feature 336005 QACT fails to connect to MSM8960.WA ACDB rel 1.2 target
Failure (Partial) Problem description
QACT fails to connect to a MSM8960.WA ACDB rel 1.2 target in Online mode.
Failure frequency: Every Time
Scenario frequency: Common
Change description
Fixed QACT not to query MBHC data from Global2 table, since it does not exist in 8960.WA rel
1.2 ACDB.
No side effect from this change is anticipated.

80-VM679-19 A 8 Qualcomm Confidential and Proprietary


MAY CONTAIN U.S. AND INTERNATIONAL EXPORT CONTROLLED INFORMATION
Bugs and Limitations

Impact
Index Technology CR Fixed bug description
category
2. Audio Function/Feature 336225 Fluence Pro/Fluence v5 specialized view cannot set value
Failure (Partial) Problem description
In QACT v2.8.17, Fluence Pro and Fluence v5 specialized view, changing checkboxes for mode
and all advanced parameters cannot be set correctly.
Failure frequency: Every Time
Scenario frequency: Common
Change description
Linked the instance with mode and advanced parameters on UI, so that they can be set correctly.
No side effect from this change is anticipated.
3. Audio Function/Feature 337103 ICS - Cannot convert GBs acdb to .c file with latest QACT
Failure (Partial) Problem description
Audio COPP topology DualMicFluence was not applied to dual mic devices in Conversion
Wizard, resulting in QACT being unable to save the converted acdb file to a .c file.
Failure frequency: Every Time
Scenario frequency: Common
Change description
Fixed the Conversion Wizard that caused the problem.
No side effect from this change is anticipated.
4. Audio Function/Feature 338258 QACT unable to set data for SET_WNR to DSP in Fluence RTC
Failure (Partial) Problem description
In Fluence RTC, QACT is not able to set data for SET_WNR to the DSP. After Mode is changed
to 0xF9F3 and user clicks Set, SET_WNR should be enabled. In addition, after Mode is changed
to 0xFDF3 and user clicks Set, SET_WNR should be disabled. However, no matter what value is
set for Mode in RTC, there is no change for SET_WNR.
Failure frequency: Every Time
Scenario frequency: Common
Change description
Hide SET_WNR from QACT UI. For get/set functionality, its behavior should be same as for
other ParamIDs.
No side effect from this change is anticipated.

80-VM679-19 A 9 Qualcomm Confidential and Proprietary


MAY CONTAIN U.S. AND INTERNATIONAL EXPORT CONTROLLED INFORMATION
Bugs and Limitations

Impact
Index Technology CR Fixed bug description
category
5. Audio Function/Feature 339581 Need to allow negative button voltage value in QACT
Failure (Partial) Problem description
In MBHC, the following two arrays cannot be set as negative values:
- MBHC_VButLow[MBHC_NumBut]
- MBHC_VButHigh[MBHC_NumBut]
Failure frequency: Every Time
Scenario frequency: Common
Change description
Updated the value range for following two arrays to -3000 ~ 3000:
- MBHC_VButLow[MBHC_NumBut]
- MBHC_VButHigh[MBHC_NumBut]
No side effect from this change is anticipated.
6. Audio Function/Feature 339739 QACT unable to open workspace files created in QACT v2.8.16 and earlier.
Failure (Partial) Problem description
QACT cannot open workspace files created in QACT v2.8.16 and earlier due to unmatched
names in the file.
Failure frequency: Every Time
Scenario frequency: Common
Change description
When QACT opens a workspace file created in QACT v2.8.16 and earlier, it automatically fixes
the unmatched names.
No side effect from this change is anticipated.

80-VM679-19 A 10 Qualcomm Confidential and Proprietary


MAY CONTAIN U.S. AND INTERNATIONAL EXPORT CONTROLLED INFORMATION
Bugs and Limitations

Impact
Index Technology CR Fixed bug description
category
7. Audio Function/Feature 339744 Voice DRC specialized view to have hard-coding for downsamplelevel changed from 8 to 1 and
Failure (Partial) allow field to be editable
Problem description
The downsamplelevel is not a part of DSP voice DRC interface. It is only a UI parameter in
QACT. Before it was hardcoded as 8 on the DSP. In QACT DRC specialized view, it is also hard
coded as 8 and read-only. However, it has been changed to 1 instead of 8 on the DSP. It should
be updated in QACT to match.
Failure frequency: Every Time
Scenario frequency: Common
Change description
Changed downsamplelevel default value to 1. Also, to make DRC specialized view backward
compatible, needed to make it editable for customers, so that for old DSP tuning, 8 still can be
used as the downsamplelevel.
Files affected
MBDRCDataPanel.cs
No side effect from this change is anticipated.
8. Audio Function/Feature 339852 AF coeffs spec view of Echo canceller not updating correctly in RTC mode
Failure (Partial) Problem description
AF coeffs spec view of Echo canceller is not updating correctly in RTC mode. The query to get
NLMS_Taps was failing since the parameter name was recently updated to AF_Taps
Failure frequency: Every Time
Scenario frequency: Common
Change description
Updated AF coeffs spec view to correctly query AF_Taps.
No side effect from this change is anticipated.
9. Audio Function/Feature 339874 QACT unable to push AFE common data in Online mode
Failure (Partial) Problem description
QACT was not handling the case to set AFE common data in Online mode.
Failure frequency: Every Time
Scenario frequency: Common
Change description
Updated QACT to handle setting AFE common data in Online mode.
No side effect from this change is anticipated.

80-VM679-19 A 11 Qualcomm Confidential and Proprietary


MAY CONTAIN U.S. AND INTERNATIONAL EXPORT CONTROLLED INFORMATION
Bugs and Limitations

Impact
Index Technology CR Fixed bug description
category
10. Audio User Experience 336053 In MSM8960 single mic voice RTC, AF_Coeffs graphic view shows the first point for 'reserved'
Problem description
In MSM8960 single mic voice RTC, AF_Coeffs graphic view shows the first point for 'reserved'.
The 'reserved' is an int16 value after numbOfTaps, which exists in single mic topology only.
Sometimes, it contains an unusual value instead of '0' in the DSP. This may cause the AF_Coeffs
graphic to look incorrect.
Failure frequency: Every Time
Scenario frequency: Common
Change description
Updated AF_Coeffs view to skip 'reserved' value for single mic and tri-mic topologies.
No side effect from this change is anticipated.
1

2 3.3 Limitations
3 This release has the following limitations:
4  MBADRC and MBDRC crossover frequency points are not persisted to the QACT™ workspace file.
5  In RTC, voice samplerate cannot be obtained. HPF module may show an error message since cut_off_freq could not be identified
6 without the correct voice samplerate.
7

80-VM679-19 A 12 Qualcomm Confidential and Proprietary


MAY CONTAIN U.S. AND INTERNATIONAL EXPORT CONTROLLED INFORMATION
1 4 QACT Test Notes

2 This release of QACT has been tested with:


3  Qualcomm Product Support Tool (QPST™) v2.7.369
4  Qualcomm USB Network Driver Package 1.0.6.0
5 Many of QACT’s changes are dependent on changes in the CRM build. This release of QACT
6 has been tested on either internal software releases or CRM Builds of the following Product Lines
7 (PLs). If testing has been done on an internal software release, then a CR is listed that can be used
8 to track the changes into a CRM build. The PLs include:
9  MSM8930.WP.1.0:
10  CR tracking to CRM build is CR 339780

11 NOTE: Build IDs of the applicable customer-facing software releases used for testing will be provided in
12 revision B of these release notes.

13

80-VM679-19 A 13 Qualcomm Confidential and Proprietary


MAY CONTAIN U.S. AND INTERNATIONAL EXPORT CONTROLLED INFORMATION
1 A ACDB Conversion Wizard Support

2 NOTE: New conversions that are added to this release are indicated with boldface type.

3 The ACDB Conversion Wizard supports the following conversions:


4  MSM7x30:
5  MSM7x30 ACDB rel.0.12 to MSM7x30 ACDB rel.0.13
6  MSM7x30 ACDB rel.0.13 to MSM7x30 ACDB rel.0.14
7  MSM7x30 ACDB rel.0.15 to MSM7x30 ACDB rel.0.16
8  MSM7x30 ACDB rel.0.16 to MSM7x30 ACDB rel.0.17
9  MSM7x30 ACDB rel.0.16 to MSM7x30 ACDB rel.1.0
10  MSM7x30 ACDB rel.1.0 to MSM7x30 ACDB rel.1.1
11  MSM7x30 ACDB rel.1.1 to MSM7x30 ACDB rel.1.2
12  MSM7x30 ACDB rel.0.17 to MSM7x30 ACDB rel.0.18
13  MSM7x30 ACDB rel.0.18 to MSM7x30.RM.1.2 ACDB rel.1.0
14  MSM7x30 ACDB rel.0.18 to MSM7x30 ACDB rel.0.19
15  MSM7x30 ACDB rel.0.19 to MSM7x30.RM.1.2 ACDB rel.1.0
16  MSM7x30 ACDB.rel.0.19 to MSM7x30.RM.1.2 ACDB.rel.1.0
17  MSM8660:
18  MSM8660 ACDB rel.1.7 to MSM8660 ACDB rel.1.7.1
19  MSM8660 ACDB rel.1.7.1 to MSM8660.LA.3.0 ACDB rel.1.1
20  MSM8660.LA.3.0 ACDB rel.1.1 to MSM8660.LA.4.0 ACDB rel.1.0
21  MSM8660.LA.3.0 ACDB rel.1.1 to MSM8960.LA.1.0 ACDB rel.1.0
22  MSM8660.LA.4.0 ACDB rel 1.0 to MSM8660.LA.4.0 ACDB rel 1.1
23  MSM8960.LA:
24  MSM8960.LA.1.0 ACDB rel 1.0 to MSM8960.LA.1.0 ACDB rel 1.1
25  MSM8960.LA.1.0 ACDB rel 1.1 to MSM8960.LA.1.0 ACDB rel 1.2
26  MSM8960.LA.1.0 ACDB rel 1.2 to MSM8960.LA.1.0 ACDB rel 1.3
27  MSM8960.LA.1.0 ACDB rel 1.3 to MSM8960.LA.1.0 ACDB rel 1.4
28  MSM8960.LA.1.0 ACDB rel 1.4 to MSM8960.LA.1.0 ACDB rel 1.5

80-VM679-19 A 14 Qualcomm Confidential and Proprietary


MAY CONTAIN U.S. AND INTERNATIONAL EXPORT CONTROLLED INFORMATION
ACDB Conversion Wizard Support

1  MSM8960.QX:
2  MSM8960.QX.1.0 ACDB rel 1.0 to MSM8960.QX.1.0 ACDB rel 1.1
3  MSM8960.QX.1.0 ACDB rel 1.1 to MSM8960.QX.1.0 ACDB rel 1.2
4  MSM8960.QX.1.0 ACDB rel 1.2 to MSM8960.QX.1.0 ACDB rel 1.3
5  MSM8960.QX.1.0 ACDB rel 1.3 to MSM8960.QX.1.0 ACDB rel 1.4
6  MSM8960.QX.1.0 ACDB rel 1.4 to MSM8960.QX.1.0 ACDB rel 1.5
7  MSM8960.QX.1.0 ACDB rel 1.5 to MSM8960.QX.1.0 ACDB rel 1.6
8  MSM8960.WA.1.0:
9  MSM8960.WA.1.0 ACDB rel 1.0 to MSM8960.WA.1.0 ACDB rel 1.1
10  MSM8960.WA.1.0 ACDB rel 1.1 to MSM8960.WA.1.0 ACDB rel 1.2
11  MSM8960.WA.1.0 ACDB rel 1.2 to MSM8960.WA.1.0 ACDB rel 1.3
12  MSM8960.WA.1.0 ACDB rel 1.3 to MSM8960.WA.1.0 ACDB rel 1.4
13

80-VM679-19 A 15 Qualcomm Confidential and Proprietary


MAY CONTAIN U.S. AND INTERNATIONAL EXPORT CONTROLLED INFORMATION
1 B Test Cases

2 Table B-1 gives the test cases for this release.

3 Table B-1 Test cases


Index ACDB version Test mode Test case Test result
1 MSM8930.WP.1.0 rel1.0 Offline Open_Save_Open_Save_Compare_Files Pass
2 QACT only RTC CR 339747 – Support AF Coeffs monitoring view for Fluence v5 and Pass
Fluence Pro in RTC
3 QACT only Online CR 336005 – QACT failure to connect to MSM8960 target because of Pass
failure to get data for MBHC in Global2 table
4 QACT only RTC CR 336053 – In MSM8960 single mic voice RTC, AF_Coeffs graphic Pass
view shows first point for 'reserved'
5 QACT only Offline/online/RTC CR 336225 – Fluence Pro/Fluence v5 specialized view cannot set Pass
value
6 QACT only RTC CR 338258 – QACT not able to set data for SET_WNR to DSP in Pass
Fluence RTC
7 QACT only Offline CR 337103 – Cannot convert GB's acdb to .c file with latest QACT Pass
8 QACT only Offline CR 339581 – MBHC QACT: Allowing negative button Voltage value Pass
9 QACT only Offline CR 339739 – Correct support for opening workspace files created in Pass
QACT v2.8.16 and earlier
10 QACT only Offline CR 339744 – Voice DRC hard-coding for downsamplelevel changed Pass
from 8 to 1; also, allow field to be editable
11 QACT only RTC CR 339852 – [MSM7x30] AF coeffs spec view not updating correctly in Pass
RTC mode
12 QACT only Online CR 339874 – [MSM8960.EA and MSM8930.WP] QACT unable to push Pass
AFE common data in online mode
4

80-VM679-19 A 16 Qualcomm Confidential and Proprietary


MAY CONTAIN U.S. AND INTERNATIONAL EXPORT CONTROLLED INFORMATION