A B C D E F G H J

DO NOT SCALE NOTES:-


FLASHING TO TOP OF FASCIA 1. DO NOT SCALE THIS DRAWING. ALL DIMENSION ARE IN
1 2 3 AS PER ARCHIRECT MILLIMETERS & LEVELS ARE IN METERS (U.N.O)
2. THIS DRAWING IS TO BE READ IN CONJUNCTION WITH ALL
4700 10000 8500 4700 RELEVANT ARCHITECTURAL, STRUCTURAL, SITE GRADING
LAYOUT DRAWINGS AND SPECIFICATIONS.
EL (+) 5.963 3. PLEASE NOTE THAT THIS STANDARD DRAWING INCLUDES ALL

TR1
TR1
750
(TOS) DETAILS FOR CANOPY BASED ON DESIGN PARAMETERS AGREED
SB2 SB2 WITH THE CLIENT AND AS PER IS CODES. THE DEC WILL SELECT

250
7 7
U/S Canopy SB2 SB2 THE APPROPRIATE DETAILS AS PER THE SITE CONDITIONS AT
FASCIA SIGNAGE AS
INDIVIDUAL LOCATIONS AND CUSTOMIZE AND COORDINATE WITH
5.500 m SB1 SB1 SB1 SB1 PER ARCHIRECT
150X250 CUTOUT FOR 150 OTHER SERVICES FOR EXECUTION.
DOWNTAKE PIPE TYP.

01
C63-702

SC1

SC1

SC1
6
50

HPP / F.G.L.
0.000 m
U/S of Base Plate
.-0.050 m
A SECTION A-A
C63-702 (Scale1 : 50) REFERENCE DRAWING:-
SR. NO. DRAWING NO. DRAWING TITLE

01 NR0P4-GEN-STDCMN-SSC-104 SPECIFICATION FOR


STRUCTURAL STEEL WORKS
5 02 NROP4-GEN-STDCNP-A04-301 ARCHITECTURAL DRAWING 5
BUILDING FOR MIXED USE
A B CANOPY
3500 3000 3500 03 NROP4-GEN-STDCMN-C01-101 GENERAL NOTES SHEET 1
GENERAL REQUIREMENTS,
ROOF SHEETING WITH FLASHING TO TOP OF FASCIA SUBMITTALS LEGENDS AND
SELF TAPPING SCREWS AS PER ARCHIRECT CONCRETE WORKS
04 NROP4-GEN-STDCMN-C01-102 GENERAL NOTES SHEET 2
1:50 SLOPE 1:50 SLOPE STRUCTURAL STEEL WORKS
P1 P1 P1 P1 P1 P1
P1
05 NROP4-GEN-STDCNP-C02-101 MIXED USE 3-PEDESTAL
TR1

TR1
(TOS) CANOPY LAYOUT & DETAILS OF

750
FOUNDATION (FROM 1.5m TO
U/S Canopy 2.5m FOUNDATION DEPTH)
06 NROP4-GEN-STDCNP-C02-102 MIXED USE 3-PEDESTAL
5.500 m
CANOPY LAYOUT & DETAILS OF
FASCIA SIGNAGE AS FOUNDATION (>2.5m TO 4.0m
02 PER ARCHIRECT FOUNDATION DEPTH )
C63-702
07 NROP4-GEN-STDCNP-C63-701 MIXED USE 3-PEDESTAL CANOPY
CANOPY ROOF FRAMING PLAN
4 08 NROP4-GEN-STDCNP-C63-703 MIXED USE 3-PEDESTAL CANOPY 4
FASCIA TRUSS ELEVATIONS
09 NROP4-GEN-STDCNP-C63-401 MIXED USE 3-PEDESTAL CANOPY
STRUCTURAL CONNECTION
DETAILS - SHEET 1
10 NROP4-GEN-STDCNP-C63-402 MIXED USE 3-PEDESTAL CANOPY
STRUCTURAL CONNECTION
DETAILS - SHEET 2

LEGEND:-
3 TOS = TOP OF STEEL
C63-702 U/S = UNDESIDE SIDE
50

3 HPP / F.G.L. 3
0.000 m
U/S of Base Plate
-0.050 m .

B SECTION B-B
C63-702 (Scale1 : 50)
DRAWING STATUS
50 150 50 ISSUED FOR IMPLEMENTATION
2 COLUMN
50

RAINWATER GUTTER
15 150 40 EL (+) 5.963 (300 WIDE x 200 DEEP) IN ROOF
(TOS) 12 THK PLATE FOR 06 01.04.2022 ISSUED FOR IMPLEMENTATION DM VJ GJ HI
REINFORCING COLUMN 05 09.03.2022 ISSUED FOR REVIEW DM VJ GJ HI
50

300

10 THK PLATE FOR P1 P1


200

AROUND CUTOUT.(ON ALL 04 26.05.2021 ISSUED FOR IMPLEMENTATION DM VJ GJ HI


2 REINFORCING COLUMN 300 50mm WIDEx10 THK FOUR FACE OF COULMN) 03 12.03.2021 ISSUED FOR IMPLEMENTATION DM VJ GJ HI 2
AROUND CUTOUT. 02 26.02.2021 ISSUED FOR IMPLEMENTATION SP VJ GJ HI
CLEATS TO SUPPORT
3D VIEW 01 19.02.2021 ISSUED FOR REVIEW SP VJ GJ HI
250

CUTOUT FOR SERVICES


PURLINS TYP CUTOUT FOR SERVICES C 00 15.02.2021 ISSUED FOR REVIEW SP VJ GJ HI
CHK APPROVED
50

REV. DATE REVISION DESCRIPTION DRN


5.963 C63-702 (Scale )
BEAM (TOS) 6MM WELD
150

6
50

ALL AROUND AECOM


HPP / F.G.L.
SB1 SB1 L50x50x6 @ 300c/c Unit No. 2, 8th Floor, Times Square, Wing A,
24

U/S Canopy 0.000 m Opp. Mittal Estate, Andheri Kurla Road,


Marol, Andheri (East), Mumbai -400059,
5.500 m Maharashtra INDIA
ALL AROUND U/S of Base Plate 58 T: +91 22 67894000
6 F: +91 22 67894111
-0.050 m www.aecom.com
COLUMN

14
SC1

200
THIS DRAWING IS PROPERTY OF RBML AND ISSUED FOR ITS CAPTIVE USE ONLY. IT SHALL NOT BE REPRODUCED,
Z 200x1.5 LOANED OR EXHIBITED WITHOUT WRITTEN PERMISSION OF RBML.


11
1 1

DETAIL - 01 DETAIL - 02 DETAIL -03 PURLIN DETAIL NEW RETAIL OUTLET - PHASE IV
01 02 3 DRAWING TITLE
C63-702 (Scale 1 : 10) C63-702 (Scale 1 : 10) C63-702 (Scale 1 : 10) (Scale 1 : 10) MIXED USE 3-PEDESTAL CANOPY
STRUCTURAL SECTION DETAIL
PROJ NO. DRAWING NO. REV.
NROP4
PLOT SCALE NROP4-GEN-STDCNP-C63-702 06
As indicated
A B C D E F G H J