Project Title : Two (2) Storey Residential Building

Lot Description : 490 Square Meters

Zoning : Residential – 1 (R-1)

Setbacks : Five (5) Meter in Front, Three (3) Meters on remaining Sides.

Problem Set Kit :

Problem Description:

The client is a wealthy bachelor who envisions his inherited lot from his parents to be a Two (2) Storey Residential
Building. The site is situated in Valle Verde, an Executive Subdivision in Ugong, Pasig City, with Subdivision
Restriction in Setbacks with Five (5) meters in front, and Three (3) meters on the remaining side, with minimum
Building Height Limit of Ten (10) meters. The site in an inside lot with a slope (See Annex A).

The Bachelor wants to have his abode to have three (3) bedrooms for (1) Himself, (2) for a future child, (3) for
Guests, and he wants to have a different approach per bedroom, and leaves the three approach to the designer,
but also points that each bedroom shall have their own Toilet and Bathroom, if it is possible to have a walk-in
closet, then include, but emphasizes that the Walk-in closet is a must in the Master Bedroom.

The Bachelor loves to cook so he requests to have a Show Kitchen, and a Dirty Kitchen. A Dining Area for Six
(6), a Breakfast Nook for quick breakfast, and a Coffee Table. In his living room, he would like to have a High
Ceiling, so he prefers not to use the space above the living area, and would like to make his living area a large
one.

On the exterior side, the Client lets the Architect to design according to the Architect’s expertise, provided that
the Client want to have a Carport for Two (2) Cars, and 1 Motorcycle Parking. In his Site Development, the Client
emphasize that service area shall have separate entrance with the living area that prevents too much cleaning
in the house, and wants to have a Koi Pond, and a Lap Pool that can be accessed through the Kitchen and
through a Bar. Other than that, the client entrusts the things that is not listed in the Design Brief to the Architect
to provide to complete the functionality, and the utilities required in the overall aesthetics of the Project.

Drawing Requirements

Architectural 19. Toilet and Bath Details with Perspective


20. Other Pertinent Details necessary
1. Technically Drawn Perspective, Site
Development Plan (on a smaller scale), Structural
Vicinity Map, Location Plan
1. General Structural Notes
2. Ground Floor Plan; Second Floor Plan
2. Foundation Plan
3. Roof Plan (integrated with Site Development
3. Ground Floor Framing Plan
Plan)
4. Second Floor Framing Plan
4. Front Elevation
5. Roof Deck Framing Plan
5. Rear Elevation
6. Roof Framing Plan
6. Left Side Elevation
7. Truss Details and its Connection Details
7. Right Side Elevation
8. Footing Detail
8. Longitudinal Section
9. Column Detail
9. Cross Section
10. Beam Detail
10. Architectural Bay Section (Showing Façade
11. Slab Detail and Section
Details)
12. Column to Beam Connection
11. Reflected Ceiling Plan, and its Details
13. Beam to Beam Connection
12. Floor Pattern Layout, and Termination Details
14. Slab Depression Details
13. Schedule of Doors and Windows
15. Stair Structural Details
14. Stair Details
16. Stiffener Column Detail
15. Kitchen Details with Perspective
17. Lintel Beam Detail
16. Landscape Development Plan (showing fence,
18. Masonry Details
landscape finishes, gate schedule)
19. Masonry to Slab Soffit Termination Detail
17. Fence Elevation and Details
20. Lap Pool Framing Plan
18. Gate Plan, Elevation, and Details
Legends:
BASIC ARCHITECTURAL DRAWINGS
ARCHITECTURAL DETAILING
STRUCTURAL DRAWINGS

Prepared by: Arch. Aldrin Ron C. Mamaril, UAP


LYCEUM OF THE PHILIPPINES UNIVERSITY
Cavite Campus
COLLEGE OF ENGINEERING COMPUTER STUDIES, AND ARCHITECTURE
DEPARTMENT OF ARCHITECTURE
BUILDING TECHNOLOGY 2
SEMESTRAL PLATE
Lot Description:

Deadline of Submissions:

1. Basic Architectural Drawings : First day of Prelim Examination Week (06:00PM)


(Pencil Submission Only)
2. Completion of Architectural Drawings : First day of Midterm Examination Week (06:00PM)
Partial Structural Drawings
(Architectural - Technical Pen; Structural – Pencil Submission)
3. Completion of Architectural and : First day of Final Examination Week (06:00PM)
Structural
(All Technical Pen - Submission in Blueprints)
Note: First Day shall mean the day of the actual subject.
Late Submissions:
Late Submission : Pass or Fail (INC at Final Examination) **
No submission : Grade equivalent to 40

Accepted Late Submission **

1. Presence of Medical Certificate (in case of sickness, with Parent-Issued Letter of Consideration)
2. Death of an IMMEDIATE Family Member with attachment of Death Certificate.
3. Other emergency situations with Parent-Issued Letter of Consideration. This note is subject for
Professor’s Approval

Submissions format:

1. Manual Drafting with Application of Full Technical Drafting, with Architectural Lettering. Lettering
Scribers, Leroy, and other writing tools can be used.
2. Copied Plans from other classmates, google, family project, etc. shall be automatically failed in the
whole semester for Cheating (Refer to College Handbook).

Pointing System
50 Point Criteria 30 Point Criteria 20 Point Criteria
0 No Submission 0 No Submission 0 No Submission
1 to 17 Below Average 1 to 16 Below Average 1 to 6 Below Average
17 to 29 Needs Improvement 10 to 17 Needs Improvement 7 to 11 Needs Improvement
30 to 38 Passing Average 18 to 22 Passing Average 12 to 14 Passing Average
39 to 45 Above Average 23 to 27 Above Average 15 to 18 Above Average
46 to 50 Above Expectation 28 to 30 Above Expectation 19 to 20 Above Expectation

Prepared by: Arch. Aldrin Ron C. Mamaril, UAP


LYCEUM OF THE PHILIPPINES UNIVERSITY
Cavite Campus
COLLEGE OF ENGINEERING COMPUTER STUDIES, AND ARCHITECTURE
DEPARTMENT OF ARCHITECTURE
BUILDING TECHNOLOGY 2
SEMESTRAL PLATE
General Plate Rubrics and Probabilities:

The rubrics indicated in this table are the probabilities of what the student can get in situations.

Grade
Verdict Description
Range
The student was not able to exercise knowledge in Building
Technology, with Mastery level of Architectural Design and Drafting
Below by proving Poor Drafting Techniques, Poor Space Planning, and
40-60
Satisfactory Poor Architectural Designing, with incomplete drawing
requirements, and very tidy work that is not acceptable in the
Architectural Standards.

The student was able to provide complete drawings but was not able
to exercise knowledge in Building Technology and was not able to
Needs
61-74 show mastery level in Architectural Design and Drafting by providing
Improvement
Poor Drafting Techniques, Poor Architectural Designing, and was
able to complete the drawings for the sake of compliance.

The student was able to provide an accepted design idea but has
75-84 Satisfactory provided an acceptable Building Technology application, and slightly
poor to acceptable Drafting Techniques with Complete Drawings

The student was able to provide an acceptable Design Idea, with


Highly Good to Excellent application of Building Technology knowledge
85-94
Satisfactory with Good to Excellent Drafting Techniques with Complete
Drawings.

The student was able to provide an exemptional design idea with


Above good to above expectation drafting techniques, building technology
95-100
Expectation knowledge, and presentation and has provided good solutions to the
design problem stipulated.

Actual Rubrics:

50% - Knowledge and Application of Building Technology

Execution of preparing complete drawing showing the representation of drawings symbols


and legends per actual Construction Methodologies, showing complete Architectural
Information and Data needed in an Architectural Construction Drawings. This includes
correctness of Architectural Details in connection, termination, actual use of materials with
correct complete specifications that completes the essence of the outcomes of the subject
matter.

30% - Applications of Architectural Design and Space Planning Techniques

The execution good design techniques and space planning techniques that responds to
the clients’ desires and performing the design with considerations to the constructive
techniques and its applicability to the actual construction.

20% - Architectural Drafting

The execution of Architectural Drafting techniques that responds to the drawing quality in
terms of Precision and Accuracy, Completeness of Drawings and Details that responds to
the overall outcomes of the project, to the Linework in performing the drawings, the
Cleanliness of the Drawings, with execution of proper Architectural Lettering Techniques.

Next Page: Annexes and Attachments

Prepared by: Arch. Aldrin Ron C. Mamaril, UAP


L M B Form No. GSD - C - 3

N LOT LOCATION

PLAN
AS PREPARED FOR
BUILDING TECHNOLOGY 2

SITUATED IN THE

457
6
RURBAN CODE :
BARANGAY OF :
MUN. OF : CITY OF PASIG
PROVINCE OF : NATIONAL CAPITAL REGION
ISLAND OF : LUZON

497
CONTAINING AN AREA OF 1734.50 SQ. M.

0
391
6
ZONE NO.:
PPCS-PTM/PRS 92:
BEARING: TRUE
SCALE 1: 200
0 1 2 5 10 20 m.

496

497
CERTIFICATION

0
544
0

497

497
0

0
496
4

Date prepared:

509
GEODETIC ENGINEER

495
2

4
Reg. Cert. No. : Date :
License No. : Date :
495
8

352
483
Republic of the Philippines

1
1
Department of Environment and Natural Resources
495
2

VERIFICATION
434
4

I certify that this survey plan is verified and found to


conform with survey data / records on file in this office.
THIS PLAN SHALL NOT BE USED FOR LAND
494
6

REGISTRATION.

DATE 20
PURPOSE
2741

CHIEF, REGIONAL SURVEYS DIVISION

NOTE:
Date Submitted
Lot cannot be used nor distributed to any lower year class.
Distribution of this Paper, or reproduction of this paper is strictly for Building Technology 2 Uses only. ADDITIONAL INFORMATION AFTER DATE OF VERIFICATION
Unauthorized use of this document shall be directly reported to Center for Students and Alumni Relations (CSAR) Office
S
Printed for the exclusive use
Building Technology 2 Students
Lyceum of the Philippines University - Cavite
Governor's Drive, Gen. Trias City, Cavite, Region IV-A
Authorized by the Department of Architecture
Until End of 2nd Semester, Academic Year 2022-2023
REG NO. : (INPUT STUDENT NO.) REPUBLIC ACT 9266, SECTION 33 CLIENT PROJECT DESCRIPTION: SHEET CONTENTS: SHEET NO:
Ownership of Plans

CREATE YOUR OWN


(affix signature)
PTR NO. : (INPUT SECTION)

ISSUED BY : LPU-C
Drawings and specifications duly signed,
stamped or sealed as instruments of service
are intellectual properties and documents of
the ARCHITECT, whether the object for which
A PROPOSED TWO (2) STOREY A/S
FIRM NAME AND LOGO
they are made is executed or not. It shall be
RESIDENTIAL BUILDING
N/O
ISSUED ON : GEN. TRIAS, CAVITE unlawful for any person, without written

FIRST NAME MI. LAST NAME IAPOA NO : (CONTACT NO.)


consent of the ARCHITECT or author of said
documents to duplicate or to make copies of
said documents for use in the repetition of ADDRESS
Student, Building Technology 2, Department of Architecture and for other projects or buildings, whether ARCH. ALDRIN RON C. MAMARIL, UAP
Lyceum of the Philippines University - Cavite Campus TIN : (EMAIL ADDRESS) executed partly or in whole. BUILDING TECHNOLOGY 2 PMARK
REPUBLIC ACT 9266, SECTION
33
Ownership of Plans
Drawings and specifications duly signed,
stamped or sealed as instruments of service
are intellectual properties and documents of
the ARCHITECT, whether the object for which
they are made is executed or not. It shall be
unlawful for any person, without written
consent of ARCHITECT or author of said
documents to duplicate or to make copies
of said documents for use in the repetition of
and for other projects or buildings, whether
executed partly or in whole.

REG NO. : (INPUT STUDENT NO.) REPUBLIC ACT 9266, SECTION 33 CLIENT PROJECT DESCRIPTION: SHEET CONTENTS: SHEET NO:
Ownership of Plans

CREATE YOUR OWN


(affix signature)
PTR NO. : (INPUT SECTION)

ISSUED BY : LPU-C
Drawings and specifications duly signed,
stamped or sealed as instruments of service
are intellectual properties and documents of
the ARCHITECT, whether the object for which
A PROPOSED TWO (2) STOREY A/S
FIRM NAME AND LOGO
they are made is executed or not. It shall be
RESIDENTIAL BUILDING
N/O
ISSUED ON : GEN. TRIAS, CAVITE unlawful for any person, without written

FIRST NAME MI. LAST NAME IAPOA NO : (CONTACT NO.)


consent of the ARCHITECT or author of said
documents to duplicate or to make copies of
said documents for use in the repetition of ADDRESS
Student, Building Technology 2, Department of Architecture and for other projects or buildings, whether ARCH. ALDRIN RON C. MAMARIL, UAP
Lyceum of the Philippines University - Cavite Campus TIN : (EMAIL ADDRESS) executed partly or in whole. BUILDING TECHNOLOGY 2 PMARK

You might also like