You are on page 1of 48

TYPICAL DETAILS

SIPSTypical Details-Version 1
DETAIL LIST AND DESCRIPTION

DETAIL LIST
DRAWING NUMBER DETAIL NUMBER DETAIL DESCRIPTION REVISION

D01 DETAIL LIST D


D100 Introduction Introduction D
D101 Detail 101 SIPS Corner Set Out Plan D
D102 Detail 102 Sole Plate Set Out Guide D
D103 Detail 103 Sole Plate - Concrete Fixing D
D104 Detail 104 Sole Plate - Concrete Fixing D
D105 Detail 105 Concrete Slab Edge Detailing D
D106 Detail 106 Concrete Set Down Detailing D
D107 Detail 107 Sole Plate - Joist Floor Fixing D
D108 Detail 108 Sole Plate - Joist Floor Fixing D
D109 Detail 109 Sole Plate - SIPS Floor Fixing D
D110 Detail 110 Sole Plate - SIPS Floor Fixing D
D111 Detail 111 SIPS FLOOR Set Down D
D112 Detail 112 SIPS FLOOR - Joist Set Down D
D200 Detail 200 Timber Joining Spline - Plan D
D201 Detail 201 SIPS Joining Spline - Plan D
D202 Detail 202 Steel Column in SIPS - Plan D
D203 Detail 203 Steel Column in SIPS - Corner Plan D
D204 Detail 204 SIPS to Existing Brick - Plan D
D205 Detail 205 Intermediate Joisted Floor - Continuous SIPS Wall D
D206 Detail 206 Intermediate Joisted Floor - Typical D
D207 Detail 207 LVL Beam Detail D
D208 Detail 208 Window Detail - POLAR -Horizontal Weatherboard D
D209 Detail 209 Window Detail - POLAR -Horizontal Weatherboard D
D210 Detail 210 SIPS Wall and Box Beam Assembly D
D211 Detail 211 SIPS Wall and Box Beam Assembled D
D212 Detail 212 SIPS Box Beam Detailing D
D213 Detail 213 Point Load Stud Hold Down D
D214 Detail 214 BOUNDARY WALL DETAIL D
D215 Detail 215 BOUNDARY WALL GUTTER D
D216 Detail 216 PARTY WALL 60/60/60 D
D217 Detail 217 PARTY WALL 90/90/90 D
D218 Detail 218 Window Tape and Flashing D
D219 Detail 219 Batten Space Ventilation D
D301 Detail 301 ROOF EAVES - TYPICAL D
D302 Detail 302 ROOF EAVES - SQUARE CUT D
D303 Detail 303 ROOF SCILLION DETAIL D
D304 Detail 304 ROOF EAVES - CONCEALED GUTTER D
D305 Detail 305 ROOF EAVES - SIPS CEILING D
D306 Detail 306 ROOF EAVES - SIPS CEILING - FLUSH GUTTER D
D307 Detail 307 ROOF EAVES - SIPS CEILING - CONCEALED GUTTER D
D308 Detail 308 SKILLION - EXTENDED ROOF SPLINE D
D309 Detail 309 EACES DETAIL - TRAD FRAMED ROOF D
D310 Detail 310 RIDGE DETAILS- TYPICAL AND HIDDEN D
D311 Detail 311 VELUS - FLAT ROOF -(FCM) D
D312 Detail312 ROOF BARGE - TYPICAL D

DISCLAIMER

THE DETAILS PORTRAYED IN THIS MANUAL ARE FOR DESIGNERS REFERENCE AND GUIDANCE ONLY. THESE ARE SIPS INDUSTRIES PRODUCT TYPICAL
DETAILS. THE DETAILS INCLUDED ARE NOT DEFINITIVE AND WILL LACK THE WATERPROOFING, FINISHING AND OFTEN THE SPECIFIC ENGINEERING OF A
PARTICULAR PROJECT. CARE MUST BE TAKEN WHEN REPLICATING THESE DETAILS TO ENSURE THE SPECIFIC PROJECT DETAILS ARE ENTIRELY
CORRECT. DETAILS ARE FOR REFERENCE, CLARITY OF INFORMATION AND ARE NOT CONCLUSIVE, SHOULD YOU NEED MORE CLARITY OF DETAILING OR
WISH TO SEE ADDITIONAL DETAILING, PLEASE CONTACT SIPS INDUSTRIES TECHNICAL TEAM. SIPS INDUSTRIES DO NOT ACCEPT ANY LIABILITY FOR
PROJECT DETAILING.

Detail Title DETAIL LIST D01


D
DTL No: REV
REFER TO SIPS INDUSTRIES FLOOR, WALL AND ROOF SPECIFICATIONS FOR STRUCTURAL AND
FIXING INFORMATION, TO BE REVIEWED IN CONJUNCTION WITH THESE DETAILS.

SIPS INDUSTRIES HAVE WORKED ON MANY VARIOUS PROJECTS AND THE DETAILS HEREWITH ARE
MERELY TYPICAL CONSTRUCTION DETAILS, FOR ADDITIONAL DETAILS OR MORE COMPLEX
DETAILS, THERE IS A GOOD POSSIBILITY THAT SIPS INDUSTRIES HAVE DETAILS THAT MAY ASSIST,
PLEASE CONTACT SIPS INDUSTRIES TECHNICAL DEPARTMENT FOR SUCH INFORMATION

SIPS INDUSTRIES WILL UPDATE SPECIFICATIONS AND DETAILS ON A REGULAR BASIS AS REQUIRED
BY INDUSTRY STANDARDS OR PRODUCT AMENDMENTS REQUIRE, IT IS ADVISED YOU CHECK OUR
WESITE DOWNLOAD SECTION [WWW.SIPSINDUSTRIES.COM.AU] TO ENURE YOU HAVE THE
CURRENT FILES.

Detail Title Introduction D100


D
DTL No: REV
Corner Set Out

-plate + 12mm- X

Pull dimensions from inside Face of Set Out Plate

90
°

12 Ensure the Gap is maintained


for panel to slot in
13

120 Sole Plate


12

Edge of Slab/ Floor

BREATHER MEMBRANE

BATTENED CAVITY

CLADDING FINISH
FOAM GLUE LINE - CONTINUOUS

SIPS BUGEL HEAD SCREW

Detail Title Detail 101 D101


D
DTL No: REV
Sole Plate Set Out

115 115

SIPS SIPS

102 X

Pull dimensions from inside Face of Set Out Plate

ENSURE SLAB EDGE IS CHECK ENGINEERING


FOR FIXING SPEC
NEAT AND STRAIGHT.
TO AT LEAST 150mm BFL

145 115

SIPS SIPS

132 X

Pull dimensions from inside Face of Set Out Plate

CHECK ENGINEERING
FOR FIXING SPEC

165 115

SIPS SIPS

152 X

Pull dimensions from inside Face of Set Out Plate

ENSURE SLAB EDGE IS CHECK ENGINEERING


FOR FIXING SPEC
NEAT AND STRAIGHT.
TO AT LEAST 150mm BFL

Detail Title Detail 102 D102


D
DTL No: REV
Sole Plate Section - Concrete Floor Part 1

SIPS INDUSTRIES EXTENAL WALL PANEL

Set Sole Plates 12mm


in from floor edge

Snap Chalk Line


12
Damp Proof Course
/ Termite Barrier

BOTTOM BATTEN
VERTICAL HOLES DRILLED
AT 600 C/C, WRAPPED WITH
INSECT CONTROL MESH
100 AND TAPED

Dynabolts min 100mm


from slab edge.
Chemical Anchors
to be centered on Sole Plate

BOLTS TO BE 900mm C/C


UNLESS OTHERWISE SPECIFIED
BY THE PROJECT ENGINEER

Detail Title Detail 103 D103


D
DTL No: REV
Sole Plate Section - Concrete Floor Part 2

PROCTOR WALL WRAP


BREATHABLE MEMBRANE
SIPS INDUSTRIES VAPOUR BARRIER
EXTENAL WALL PANEL

BATTEN/CAVITY
PLASTERBOARD

SELECTED CLADDING

CLOSING BATTEN

100

Detail Title Detail 104 D104


D
DTL No: REV
Concrete Slab Detailing

PROCTOR WALL WRAP


BREATHABLE MEMBRANE
VAPOUR BARRIER SIPS INDUSTRIES EXTERNAL WALL
PANEL

BATTEN/CAVITY
PLASTERBOARD

SELECTED CLADDING

DAMP PROOF COURSE /


TERMITE BARRIER

CLOSING BATTEN - H3

ENSURE SLAB EDGE IS


NEAT AND STRAIGHT.
TO AT LEAST 150mm BFL

Detail Title Detail 105 D105


D
DTL No: REV
Concrete Set-Down Detail

PROCTOR WALL WRAP


BREATHABLE MEMBRANE
VAPOUR BARRIER

BATTEN/CAVITY

SELECTED CLADDING

WET AREA SET DOWN

CLOSING BATTEN - H3

WHERE WET AREA STOPS.


THE SLAB UPSTAND MUST BE
NEAT AND STRAIGHT

ENSURE CONCRETE UPSTAND IS


FORMED AND IS NEAT AND LEVEL
WITH GENERAL SLAB SURFACE.
140-145mm THICK

Detail Title Detail 106 D106


D
DTL No: REV
Sole Plate Section - Joist Floor Part 1

SIPS INDUSTRIES
EXTENAL WALL PANEL
Set Sole Plates 12mm
in from floor edge
132

Snap Chalk Line 12

Perimeter Beam
Dashed indicates
Alternative Joist
Direction / Span

Detail Title Detail 107 D107


D
DTL No: REV
Sole Plate Section - Joist Floor Part 2

PROCTOR WALL WRAP


BREATHABLE MEMBRANE
SIPS INDUSTRIES VAPOUR BARRIER
EXTENAL WALL PANEL

BATTEN/CAVITY
PLASTERBOARD

SOLE PLATE FIXING TO EACH


SELECTED CLADDING
JOIST STRICTLY TO THE ENGINEERS
SPECIFICATIONS

Dashed indicates
Alternative Joist
Direction / Span

JOISTS FIXED TO TOP PALTE


IN STRICT ACCORDANCE TO
JOIST MANUFACTURERS
OR TIMBER CODE GUIDELINES

Detail Title Detail 108 D108


D
DTL No: REV
Sole Plate Section - SIPS Floor Part 1

SIPS INDUSTRIES EXTENAL WALL PANEL

SET SOLE PLATES 12mm Sole Plate +12mm


IN FLOOR FROM EDGE

SNAP CHALK LINE 12 See SIPs Fixing Schedule


FOR SET OUT

End Timber

SIPS INDUSTRIES FLOOR PANEL

DPC

SIPS FLOOR PANELS ARE TO BE


FIXED TO BEARERS WITH 225mm
SIPS SCREWS FIXED AT 300mm C/C
UNLESS OTHERWISE SPECIFIED
BY ENGINEER

Detail Title Detail 109 D109


D
DTL No: REV
Sole Plate Section - SIPS Floor Part 2

PROCTOR WALL WRAP


SIPS INDUSTRIES BREATHABLE MEMBRANE
EXTENAL WALL VAPOUR BARRIER
PANEL

BATTEN/CAVITY
PLASTERBOARD

SELECTED CLADDING

FLOORING

CLOSING BATTEN
SIPS INDUSTRIES FLOOR PANEL

SEE SIPS FIXING


SCHEDULE FOR
SOLE PLATE FIXINGS

BEARER BEAM TO ENGINEERS


SPECIFICATION

Detail Title Detail 110 D110


D
DTL No: REV
SIPS Floor -Set Down Detail SIPS

SIPS INDUSTRIES
INTERNAL WALL PANEL WATER RESISTANT
WALL LINING

PLASTERBOARD
WATER PROOFING AND
TILING BY OTHERS

FLOORING
WATER RESISTANT
SECURA FLOORING
OR SIMILAR

175 SIPS INDUSTRIES FLOOR PANEL


115 SIPS INDUSTRIES FLOOR PANEL

ADDITIONAL COUNTER BEARER SERVICE AREA

BEARER BEAM TO ENGINEERS


SPECIFICATION

Detail Title Detail 111 D111


D
DTL No: REV
SIPS Floor -Set Down Detail

SIPS INDUSTRIES
INTERNAL WALL PANEL WATER RESISTANT
WALL LINING

PLASTERBOARD
WATER PROOFING AND
TILING BY OTHERS

FLOORING
WATER RESISTANT
SECURA FLOORING
OR SIMILAR

SIPS INDUSTRIES FLOOR PANEL

ADDITIONAL COUNTER BEARER

INSULATION AND SERVICE AREA


BEARER BEAM TO ENGINEERS
SPECIFICATION

Detail Title Detail 112 D112


D
DTL No: REV
Joining Spline - Double Stud

Double Stud
2/ 35mm MGP10 Electrical Conduit

Panels Slide over


Panels Slide over
Joining Spline
Joining Spline

PRE-ASSEMBLED WALL Continuous Glue Line


Nails are Scew Fixed
70mm Ringshank Nails @150mm centers

ASSEMBLED SIPS WALL

Internal Plasterboard/Lining

FINISHED WALL Breathable Membrane


Ventilated Air CAvity - Min 19mm
Vertical Battens
Cladding Material

Detail Title Detail 200 D200


D
DTL No: REV
Joining Spline - SIPS Spline

Typical SIPS Spline Electrical Conduit

Panels Slide over


Joining Spline Panels Slide over
Joining Spline

70
PRE-ASSEMBLED WALL
Continuous Glue Line
Nails are Scew Fixed
50mm Ringshank Nails @150mm centers

ASSEMBLED SIPS WALL


Internal Plasterboard/Lining

FINISHED WALL Breathable Membrane


Ventilated Air CAvity - Min 19mm
Vertical Battens
Cladding Material

Detail Title Detail 201 D201


D
DTL No: REV
Steel Column in SIPS Wall

Steel Column to
Engineers Spec Timber to Suit

Panels Slide over Panels Slide over


Joining Spline Joining Spline
Electrical Conduit

PRE-ASSEMBLED WALL Continuous Glue Line


35mm MGP10 Fix timber to column
Nails are Scew Fixed
50mm Ringshank Nails @150mm centers

ASSEMBLED SIPS WALL


Internal Plasterboard/Lining

FINISHED WALL Breathable Membrane


Ventilated Air Cavity - Min 19mm
Vertical Battens
Cladding Material

Detail Title Detail 202 D202


D
DTL No: REV
Steel Corner Column

Steel Column to
Engineers Spec

35mm MGP10

Continuous Glue Line

Nails are Scew Fixed


@150mm centers

Breathable Membrane
Cladding Material

Vertical Battens

Ventilated Air Cavity - Min 19mm

Detail Title Detail 203 D203


D
DTL No: REV
SIPS to EXISTING BRICK - PLAN

SIPS PANEL OVER TIMBER


EXISTING BRICKWORK
PLATE FIXED PER SIPS
FIXING SCHEDULE RAMSET ANKASCREW OR AS
SPECIFIED BY ENGINEER

35mm MGP10 DPC

PLAN

Detail Title Detail 204 D204


D
DTL No: REV
Intermediate Floor Section - Continuous Wall Panel

PROCTOR WALL WRAP

IF EXTERNAL WALL
BREATHABLE MEMBRANE
SIPS INDUSTRIES VAPOUR BARRIER
EXTENAL WALL PANEL

BATTEN/CAVITY
PLASTERBOARD

SELECTED CLADDING
Dashed indicates (if applicable)
Alternative Joist
Direction / Span

FIX LVL OR TIMBER PERIMETER JOISTS


TO SIPS PANEL WITH STRUCTURAL
ADHESIVE AND TEMPORARY SCREWS
TO THE JOIST SIDE OF THE PANEL, THEN
USING SIPS SCREWS FIX FROM THE
OPPOSING SIDE OF THE PANEL,
STAGGARED AT 300mm C/C

JOISTS HANGER AND JOIST


SPACING STRICTLY TO JOIST
MANUFACTURERS OR TIMBER
CODE GUIDELINES

Detail Title Detail 205 D205


D
DTL No: REV
Intermediate Floor Section - Typical

IF EXTERNAL WALL
PROCTOR WALL WRAP
BREATHABLE MEMBRANE
SIPS INDUSTRIES VAPOUR BARRIER
EXTENAL WALL PANEL
BATTEN/CAVITY

PLASTERBOARD SELECTED CLADDING


(if applicable)
Dashed indicates
Alternative Joist FIRST FLOOR SIPS SOLE PLATE IS TO
Direction / Span BE NAIL FIXED AT 300mm C/C AND
COACH SCREWED ATJOIST CENTERS,
OR 900mm C/C ALONG PARALLEL
RUNNING JOISTS, ALTERNATIVELY
APPLY 3.5x45mm PGI STRAPPING WITH
4no 12g SCREW FIXINGS TO UPPER
AND LOWER PANEL AT EACH PANEL
JOINT.

FIX LVL OR TIMBER PERIMETER JOISTS


TO SIPS PANEL WITH 65mm NAILS AT
JOIST SPACING STRICTLY TO 150mm C/C. SMART JOISTS ARE TOE
ENGINEERS SPECIFICATION NAILED WITH 2/65mm RING SHANKS,
APPLY 1 NAIL AT 150mm C/C ALONG
JOISTS RUNNING PARALLEL TO SIPS
WALL.

Detail Title Detail 206 D206


D
DTL No: REV
LVL Beam Detail

OSB Facing
SIPS Panel supplied by
SIPS

LAMINATED
LVL BEAMS

300
265
33

115 145 Timber Packing

GLUE JOINT BETWEEN JOISTS

NAIL at 200mm C/C HORIZONTALLY


BOTH SIDES ALTERNATIVELY

NAIL 70mm FROM TOP AND BOTTOM


OF LVL BEAMS

NAIL LAMINATION
m
0m
20 SECTION SIZE 'B' NAIL DIA NAIL LENGTH
35mm 3.06mm 75mm
B 45mm 3.3mm 90mm
63mm 3.3mm 100mm

Detail Title Detail 207 D207


D
DTL No: REV
WINDOW DETAIL - Polar Window with CS Sheeting

10mm PLASTERBOARD
BREATHER MEMBRANE
145mm SIPS INDUSTRIES PANEL EXTERNAL CLADDING MATERIAL
AIR-TIGHT TAPE
120x35 MGP10 35mm EXERNAL BATTENS

POLAR DOUBLE GLAZING PROFILE

INTERNAL SIPS AIR-TIGHT SEALANT TAPE


SILL

* SIPS INDUSTRIES PANELS WILL ACCEPT ALMOST ANY WINDOW AND MAY NEED
PROJECT SPECIFIC DETAILING BY THE DESIGNER - WIINDOWS SHOWN ARE INDICITIVE ONLY

Detail Title Detail 208 D208


D
DTL No: REV
WINDOW DETAIL- Polar Window with Weatherboard

MIN 30mm OVERLAP

30
10mm PLASTERBOARD
BREATHER MEMBRANE
145mm SIPS INDUSTRIES PANEL EXTERNAL CLADDING MATERIAL
AIR-TIGHT TAPE
120x35 MGP10 35mm EXERNAL BATTENS

66x30 H3 LOSP Pre-Primed


AND SECRET FIXED
POLAR DOUBLE
GLAZING PROFILE

INTERNAL SILL

66x30 H3 LOSP Pre-Primed


AND SECRET FIXED

HORIZONTAL BATTEN

SIPS AIR-TIGHT SEALANT TAPE

145
SIPS PANEL

* SIPS INDUSTRIES PANELS WILL ACCEPT ALMOST ANY WINDOW AND MAY NEED
PROJECT SPECIFIC DETAILING BY THE DESIGNER - WIINDOWS SHOWN ARE INDICITIVE ONLY

Detail Title Detail 209 D209


D
DTL No: REV
BOX BEAM & WALL ASSEMBLY

SIPS BOX BEAM


.

DOUBLE OR TRIPLE
TIMBER ENDS

.
.

TOP PLATE
BOX BEAM BASE PLATE SIPS SPLINE

SIPS 'BOX BEAM' LINTELS .


[NAIL AT 60mm C/C AND FOR
600mm ALONG TOP PLATE]

TOP PLATE

.
CRIPPLE STUDS
. SINGLE OR DOUBLE
AS SPEC BY ENGINEER

.
WINDOW INFILL PANELS

BASE PLATE
SIPS SPLINE
.

SIPS SCREWS TO CORNER JUNCTION

BASE PLATE

Detail Title Detail 210 D210


D
DTL No: REV
BOX BEAM & WALL ASSEMBLED

TOP PLATE

BASE PLATE

WINDOW INFILL PANELS


.

SIPS SCREWS TO CORNER JUNCTION

BASE PLATE

Detail Title Detail 211 D211


D
DTL No: REV
Box Beam Assembly - Exploded View

Continuous Top Plate

35
105

Varies
35
Continuous Bottom Plate

70 70

Box Beam Assembly - Assembled

60mm c/c for 600mm


Varies

BB

Nailing at 60mm c/c

Verticle Stud
Nailing at 150 c/c
70

Detail Title Detail 212 D212


D
DTL No: REV
STUD TIE DOWN DETAIL TYPE #1
TIMBER STUD

SIPS INDUSTRIES WALL PANEL

TIMBER STUD
TIE DOWN STUD ENCLOSED WITHIN
PANEL

TIMBER BOTTOM PLATE ANCHORED TO


CONCRETE WITH M12 ANCHOR BOLTS
TO ENGINEERS SPEC, CHEMSET OR TRUBOLT.

SOLE PLATE

150 150
30x1.0 GALVANISED TIE DOWN STRAP
FIXED VIA 6/2.8Ømm GALV NAILS TO
BOTH SIDES, ONE STRAP PER STUD

STUD TIE DOWN DETAIL TYPE #2


TIMBER STUD

TIMBER STUD

O
SB
SIPS INDUSTRIES WALL PANEL
NAILING @ 60mm C/C

NAILING @ 60mm C/C


TIE DOWN STUD ENCLOSED WITHIN
PANEL
600

600

TIMBER BOTTOM PLATE ANCHORED TO


CONCRETE WITH M12 ANCHOR BOLTS
TO ENGINEERS SPEC, CHEMSET OR TRUBOLT.

SOLE PLATE

NAIL OSB LOCALLY @ 60mm C/C 75 75


UP TO 600mm HIGH AND 300mm
EACH SIDE TO SOLE PLATE 300 300

NAILING @ 60mm C/C

Detail Title Detail 213 D213


D
DTL No: REV
SIPS 60/60/60 BOUNDARY WALL

HB FULLER FIRESOUND
SEALANT TOP OF WALL

25mm PLASTERBOARD SCREWS


Fixings are to be spaced at nominal 300mm centers SIPS INDUSTRIES PANEL WALL
into the perimeter studs and 200mm into the vertical
butt joints, maintaining nominal 12-15mm spacing BUILD TO MANUFACTURERS SPECIFICATIONS
from the board edge. The spacing in the field of the
sheets is to be 300mm.
SELECTED CEMENT SHEET
41mm PLASTERBOARD SCREWS CLADDING AS PER DRAWINGS
Fixings are to be spaced at nominal 300mm centers
into the perimeter studs and 200mm into the vertical AND/OR WORKS SPECIFICATION
butt joints, maintaining nominal 12-15mm spacing
from the board edge. The spacing in the field of the
sheets is to be 300mm. 16mm CSR FYRCHECK PLASTERBOARD

19mm NON-COMBUSTABLE BATTENING


145 78

JOINTING COMPOUND
CSR Gyprock Basecoat 45 or equivalent approved.
Nominal 50mm wide perforated tape along joints
on the outer layer of plasterboard

SEALANT PROCTOR WALL WRAP (RW)


HB FULLER FireSound Acryllic Sealant to be applied BREATHER MEMBRANE
to the perimeter plasterboard interface as detailed on VAPOUR BARRIER - WRAPED
ALL layers of Fyrcheck boards including any permitted AROUND BOTTOM ROOF BATTEN
services

16mm CSR FYRCHECK PLASTERBOARD


DAMP PROOF COURSE
PHYSICAL TERMITE BARRIER 13mm CSR FRYCHECK PLASTERBOARD

HB FULLER FIRESOUND
BOUNDARY

SEALANT

20

Detail Title Detail 214 D214


D
DTL No: REV
SIPS 60/60/60 BOUNDARY WALL GUTTER

NON-COMBUSTABLE ROOF FINISH

ROOF BATTEN / VENTED CAVITY

PROCTOR ROOFSHEILD
BREATHER MEMBRANE
VAPOUR BARRIER
DRESSED INTO GUTTER

SIPS SCREW FIXINGS AT 300mm C/C

STRATCO C-SQUARE GUTTER


OR SIMILAR APPROVED

DPC BEHIND GUTTER AND


DRESSED OVER FYRCHECK

SELECTED CEMENT SHEET


10mm PLASTERBOARD
CLADDING AS PER DRAWINGS
AND/OR WORKS SPECIFICATION

175 SIPS INDUSTRIES 66 79 NON-COMBUSTABLE BATTENING


ROOF PANEL SYSTEM - R4.4
PROCTOR WALL WRAP (RW)
BREATHER MEMBRANE
16mm CSR FYRCHECK
VAPOUR BARRIER - WRAPED
PLASTERBOARD
AROUND BOTTOM ROOF BATTEN

145mm SIPS 16mm CSR FYRCHECK PLASTERBOARD


13mm CSR FRYCHECK PLASTERBOARD
145 76
BOUNDARY

20

Detail Title Detail 215 D215


D
DTL No: REV
SIPS 60/60/60 PARTY WALL

338

BOUNDARY
HB FULLER FIRESOUND
SEALANT
25mm PLASTERBOARD SCREWS TOP OF WALL
Fixings are to be spaced at nominal 300mm centers
into the perimeter studs and 200mm into the vertical
butt joints, maintaining nominal 12-15mm spacing SIPS INDUSTRIES PANEL WALL
from the board edge. The spacing in the field of the BUILD TO MANUFACTURERS
sheets is to be 300mm. SPECIFICATIONS
41mm PLASTERBOARD SCREWS
Fixings are to be spaced at nominal 300mm centers
into the perimeter studs and 200mm into the vertical
butt joints, maintaining nominal 12-15mm spacing
from the board edge. The spacing in the field of the
sheets is to be 300mm.
40 or 50mm BUILDING GAP
50mm FIBREWOOL
ROXUL STONEWOOL or equivalent approved FIBRE WOOL INSULATION
insulation between SIPS wall with a density of MIN DENSITY 14kg/m³
14kg/m³ or greater for acoustic purposes

JOINTING COMPOUND
CSR Gyprock BAsecoat 45 or equivalent approved.
Nominal 50mm wide perforated tag along joints
on the outer layer of plasterboard

SEALANT
HB FULLER FireSound Acryllic Sealant to be applied
to the perimeter plasterboard interface as detailed on
ALL layers of Fyrcheck boards.

16mm CSR FYRCHECK


PLASTERBOARD

13mm CSR FRYCHECK


PLASTERBOARD

HB FULLER FIRESOUND
SEALANT

ACOUSTIC
THIS WALL SYSTEMS HAS BEEN TESTED IN ACCORDANCE WITH AS1191 -
REPORT REF ALA-12-089-2, RESULTING IN AN ACOUSTING RATING OF: Rw64(-2-7)

Detail Title Detail 216 D216


D
DTL No: REV
SIPS 90/90/90 PARTY WALL

414

BOUNDARY
HB FULLER FIRESOUND
SEALANT
25mm PLASTERBOARD SCREWS TOP OF WALL
Fixings are to be spaced at nominal 300mm centers
into the perimeter studs and 200mm into the vertical
butt joints, maintaining nominal 12-15mm spacing SIPS INDUSTRIES PANEL WALL
from the board edge. The spacing in the field of the BUILD TO MANUFACTURERS
sheets is to be 300mm. SPECIFICATIONS
41mm PLASTERBOARD SCREWS
Fixings are to be spaced at nominal 300mm centers
into the perimeter studs and 200mm into the vertical
butt joints, maintaining nominal 12-15mm spacing
from the board edge. The spacing in the field of the
sheets is to be 300mm.

TOP HATS
40 or 50mm BUILDING GAP
Installed between the plasterboard layers as detailed. FIBRE WOOL INSULATION
Fixed at 600mm centers vertically. MIN DENSITY 14kg/m³

50mm FIBREWOOL
ROXUL STONEWOOL or equivalent approved
insulation between SIPS wall with a density of
14kg/m³ or greater for acoustic purposes

25mm FIBREWOOL
ROXUL STONEWOOL or equivalent approved
insulation between top hats with a density of
14kg/m³ or greater for its fire retartant properties

JOINTING COMPOUND
CSR Gyprock BAsecoat 45 or equivalent approved.
Nominal 50mm wide perforated tag along joints
on the outer layer of plasterboard
16mm CSR FYRCHECK
SEALANT PLASTERBOARD
HB FULLER FireSound Acryllic Sealant to be applied
to the perimeter plasterboard interface as detailed on
ALL layers of Fyrcheck boards.
13mm CSR FRYCHECK
PLASTERBOARD

HB FULLER FIRESOUND
SEALANT

Detail Title Detail 217 D217


D
DTL No: REV
WINDOW MEMBRANE & TAPE INSTALL
THIS DETAIL IS FOR A WINDOW WITH A FIN TO PANEL CONNECTION (NOT A RECESSED WINDOW) ADN IS A WATER-
PROOFING DETAIL ONLY, THIS MAY NOT PROVIDE A FULLY AIR-TIGHT DETAIL. SUCH DETAILS ARE OFTEN PROJECT
SPECIFIC - THESE ARE TYPICAL DETAILS ONLAY AND ARE FOR REFERENCE PURPOSES FOR THE DESIGNER.

Cut Membrane Fold 'wings'


up 150mm into Reveal
Window Opening

UT
C

Primary Tape
OR Profiled Sill

. .
Cut Horizontally Secondary Sill Tape
to fit secondary tape

1.CUT MEMBRANE AS SHOWN 2.DRESS MEMBRANE INTO REVEAL 4.INSTALL WINDOW WITH SILL
3.APPLY SECONDARY SILL TAPE 5.IF NO SILL, APPLY PRIMARY TAPE

Dress Membrane
Over Flashing

TOP TAPE
Vertical Tape
Over SIll Tape DPC Lapped Under
Membrane by 150mm

6.APPLY VERTICAL SEALANT TAPES 7.APPLY TOP SEALANT TAPE 9.FOLD MEMBRANE DOWN
8.DRESS DPC BEHIND MAMBRANE

Tape Membrane Cut Air Movement

10.TAPE MEMBRANE OVER DPC 11.INSTALL BATTENS 12.INSTALL CLADDING

FIND THE OPENING CAREFULLY AND FIT SECONDARY WINDOW SILL APPLY PRIMARY TAPES, BEGINNING
CUT AN INVERTED 'Y' INTO THE MEMBRANE TAPE OR SIMILAR TRAY AT THE SILL OF THE WINDOW, THEN
VERTICALLY, AND FINALLY APPLYING
THE HEAD DETAIL AS ABOVE.

Detail Title Detail 218 D218


D
DTL No: REV
VENTILATED CAVITY

A VENTILATED CAVITY IS IMPORTANT TO CREATE AN AIRFLOW BETWEEN THE BREATHER MEMBRANE


SURROUNDING THE STRUCTURE AND THE CLADDING. ANY MOISTURE WITHIN THE STRUCTURE WILL BE
PULLED INTO THE VENTILATED SPACE THROUGH THE VAPOUR PERMEABLE MEMBRANE. THE AIR MOVEMENT
ALLWS THE VAPOUR TO EXPELL TO THE OUTDOORS ENSURING A DRY BUILDING WITH NO CHANCE OF MOISTURE
BUILD UP BEHIND CLADDINGS AND IN FRAMEING CASUNG MOULD, ROT, ALSO OTHERWISE KNOWN AS
'LEAKY' OR 'SICK BUILDING SYNDROME'.

REFER TO PREVIOUS DETAIL


FOR WINDOW SEALING OPTION

THE BOTTOM BATTEN IS DRILLED THROUGH


AND WRAPPED IN INSECT PROOF MESH THUS
CREATING AIR FLOW FROM THE BASE.

ALLOWING GAPS BETWEEN THE WALL BATTENS WILL


PERMIT THE AIR TO MOVE FREELY ACROSS THE ENTIRE
WALL AND NOT JCUST RESTRICTED TO A 'COMPARTMENT'.

ALLOWING FOR A VENT AT THE TOP OF THE CLADDING,


BEIT INTO THE ROOF SPACE, BEHIND THE FASCIA AND
OR SOFFIT OR AS DESIGNED IN BY THE DESIGNER, IS
ALSO IMPORTANT AS WARM MOIST AIR RISES.

THE IMAGE ON THE RIGHT DISPLAYS HOW THE BATTEN


HAS BEEN DRILLED AND SURROUNDED WITH INSECT
PROOF MESH, AND TAPED TO STOP INSECTS ACCESSING
FROM THE SIDES

Detail Title Detail 219 D219


D
DTL No: REV
SIPS EAVES DETAIL -PLUMB CUT ROOF

SIPS SCREW FIXINGS AT 300mm C/C


UNLESS OTHERWISE SPECIFIED BY
PROJECT ENGINEER
SELECTED ROOF CLADDING
ON SELECTED BATTENS
PROVIDE 10mm SHIMS BENEATH
HORIZONTAL BATTENS TO ALLOW
FOR MOISTURE FLOW

SIPS INDUSTRIES PROVIDED


BREATHABLE MEMBRANE.
LAPS OF AT LEAST 150mm.
TAPED LAPS FOR LOW PITCH
ROOFS, LAP MEMBRANE INTO GUTTER

SELECTED GUTTER
AND FASCIA BOARD/PROFILE

SIPS INDUSTRIES ROOF PANEL


GENERALLY 175mm THICK R4.4
SEE TECHNICAL SPECIFICATIONS
FOR SPANS AND OTHER INFORMATION
SELECTED SOFFIT LINING DORECT
TO PANEL OR TRADITIONAL ALTERNATIVE
SHOWN DASHED

SIPS INDUSTRIES EXTERNAL WALL PANEL


WITH BREATHER MEMBRANE, VERTICAL
BATTENS AND SELECTED CLADDING.
PROVIDE CAVITY VENTILATION PER
SIPS INDUSTRIES SPECIFICATIONS

Detail Title Detail 301 D301


D
DTL No: REV
SIPS EAVES DETAIL -SQUARE CUT ROOF

SIPS SCREW FIXINGS AT 300mm C/C


UNLESS OTHERWISE SPECIFIED BY
PROJECT ENGINEER
SELECTED ROOF CLADDING
ON SELECTED BATTENS
PROVIDE 10mm SHIMS BENEATH
HORIZONTAL BATTENS TO ALLOW
FOR MOISTURE FLOW

SIPS INDUSTRIES PROVIDED


BREATHABLE MEMBRANE.
LAPS OF AT LEAST 150mm.
TAPED LAPS FOR LOW PITCH
ROOFS, LAP MEMBRANE INTO GUTTER

SELECTED GUTTER
AND FASCIA BOARD/PROFILE
SIPS INDUSTRIES ROOF PANEL
GENERALLY 175mm THICK R4.4
SEE TECHNICAL SPECIFICATIONS
FOR SPANS AND OTHER INFORMATION
SELECTED SOFFIT LINING DORECT
TO PANEL OR TRADITIONAL ALTERNATIVE
SHOWN DASHED

SIPS INDUSTRIES EXTERNAL WALL PANEL


WITH BREATHER MEMBRANE, VERTICAL
BATTENS AND SELECTED CLADDING.
PROVIDE CAVITY VENTILATION PER
SIPS INDUSTRIES SPECIFICATIONS

Detail Title Detail 302 D302


D
DTL No: REV
SIPS SKILLION DETAIL - PLUMB CUT

COLORBOND PROFILE CAPPING


SIPS SCREW FIXINGS AT 300mm C/C
UNLESS OTHERWISE SPECIFIED BY
PROJECT ENGINEER
SELECTED ROOF CLADDING
ON SELECTED BATTENS
PROVIDE 10mm SHIMS BENEATH
HORIZONTAL BATTENS TO ALLOW
FOR MOISTURE FLOW

SIPS INDUSTRIES PROVIDED


BREATHABLE MEMBRANE.
LAPS OF AT LEAST 150mm.
TAPED LAPS FOR LOW PITCH
ROOFS, LAP MEMBRANE INTO GUTTER

SELECTED
SOFFIT
LINING SIPS INDUSTRIES ROOF PANEL
GENERALLY 175mm THICK R4.4
SEE TECHNICAL SPECIFICATIONS
FOR SPANS AND OTHER INFORMATION

SIPS INDUSTRIES EXTERNAL WALL PANEL


WITH BREATHER MEMBRANE, VERTICAL
BATTENS AND SELECTED CLADDING.
PROVIDE CAVITY VENTILATION PER
SIPS INDUSTRIES SPECIFICATIONS

Detail Title Detail 303 D303


D
DTL No: REV
SIPS EAVES DETAIL -CONCEALED GUTTER

SELECTED ROOF CLADDING


ON SELECTED BATTENS
PROVIDE 10mm SHIMS BENEATH
HORIZONTAL BATTENS TO ALLOW
FOR MOISTURE FLOW

SIPS INDUSTRIES PROVIDED


BREATHABLE MEMBRANE.
LAPS OF AT LEAST 150mm.
TAPED LAPS FOR LOW PITCH
ROOFS, LAP MEMBRANE INTO GUTTER

SELECTED GUTTER

TOP OF WALL FLASHED INTO


CAVITY OVER BREATHER MEMBRANE

SIPS SCREW FIXINGS AT 300mm C/C


UNLESS OTHERWISE SPECIFIED BY
PROJECT ENGINEER

SIPS INDUSTRIES ROOF PANEL


GENERALLY 175mm THICK R4.4
SEE TECHNICAL SPECIFICATIONS
FOR SPANS AND OTHER INFORMATION

SIPS INDUSTRIES EXTERNAL WALL PANEL


WITH BREATHER MEMBRANE, VERTICAL
BATTENS AND SELECTED CLADDING.
PROVIDE CAVITY VENTILATION PER
SIPS INDUSTRIES SPECIFICATIONS

Detail Title Detail 304 D304


D
DTL No: REV
SIPS EAVES DETAIL -SIPS CEILING

SIPS INDUSTRIES ROOF PANEL


GENERALLY 175mm THICK R4.4
SEE TECHNICAL SPECIFICATIONS
FOR SPANS AND OTHER INFORMATION

SELECTED ROOF CLADDING


ON SELECTED BATTENS

SARKING OVER RAFTERS


USE TILTING FILLET TO SUPPORT SARKING

SELECTED GUTTER
AND FASCIA BOARD/PROFILE
TIMBER RAFTER WITH BIRDSMOUTH OVER
WALL PLATE, OR OVER PANEL END
SELECTED SOFFIT LINING DORECT
TO PANEL OR TRADITIONAL ALTERNATIVE
SHOWN DASHED

SIPS SCREW FIXINGS AT 300mm C/C


UNLESS OTHERWISE SPECIFIED BY
PROJECT ENGINEER

SIPS INDUSTRIES EXTERNAL WALL PANEL


WITH BREATHER MEMBRANE, VERTICAL
BATTENS AND SELECTED CLADDING.
PROVIDE CAVITY VENTILATION PER
SIPS INDUSTRIES SPECIFICATIONS

Detail Title Detail 305 D305


D
DTL No: REV
SIPS EAVES DETAIL -SIPS CEILING -FLUSH
GUTTER

SIPS INDUSTRIES ROOF PANEL


GENERALLY 175mm THICK R4.4
SEE TECHNICAL SPECIFICATIONS
FOR SPANS AND OTHER INFORMATION

SELECTED ROOF CLADDING


ON SELECTED BATTENS

SARKING OVER RAFTERS


USE TILTING FILLET TO SUPPORT SARKING

SELECTED GUTTER
PROVIDE PROFILED FLASHING BEHIND
GUTTER OVER EXTERNAL WALL AND
BREATEHR MEMBRANE

TIMBER RAFTER SKEW NAILED OR PRYDA


TRIPLE GRIP TO WALL PLATE WHICH IS
BUGLE FIXED TO SIPS PANEL AND
TOP PLATE OF WALL PANELS

SIPS SCREW FIXINGS AT 300mm C/C


UNLESS OTHERWISE SPECIFIED BY
PROJECT ENGINEER
SIPS INDUSTRIES EXTERNAL WALL PANEL
WITH BREATHER MEMBRANE, VERTICAL
BATTENS AND SELECTED CLADDING.
PROVIDE CAVITY VENTILATION PER
SIPS INDUSTRIES SPECIFICATIONS

Detail Title Detail 306 D306


D
DTL No: REV
SIPS EAVES DETAIL - EXTENDED SPLINE

SIPS SCREW FIXINGS AT 300mm C/C


UNLESS OTHERWISE SPECIFIED BY
PROJECT ENGINEER
SELECTED ROOF CLADDING
ON SELECTED BATTENS
PROVIDE 10mm SHIMS BENEATH
HORIZONTAL BATTENS TO ALLOW
FOR MOISTURE FLOW

SIPS INDUSTRIES PROVIDED


BREATHABLE MEMBRANE.
LAPS OF AT LEAST 150mm.
TAPED LAPS FOR LOW PITCH
ROOFS, LAP MEMBRANE INTO GUTTER

EXTENDED LVL SPLINE @MAX 1200 c/c


FOR FURTHER DETAILING BY BUILDER
SIPS INDUSTRIES ROOF PANEL
GENERALLY 175mm THICK R4.4
SEE TECHNICAL SPECIFICATIONS
FOR SPANS AND OTHER INFORMATION
SELECTED SOFFIT LINING DORECT
TO PANEL OR TRADITIONAL ALTERNATIVE
SHOWN DASHED

SIPS INDUSTRIES EXTERNAL WALL PANEL


WITH BREATHER MEMBRANE, VERTICAL
BATTENS AND SELECTED CLADDING.
PROVIDE CAVITY VENTILATION PER
SIPS INDUSTRIES SPECIFICATIONS

Detail Title Detail 307 D307


D
DTL No: REV
SIPS SKILLION DETAIL - EXTENDED SPLINE

EXTENDED LVL SPLINES AT MAX 1200c/c


FOR FURTHER DETAILING BY BUILDER

COLORBOND PROFILE CAPPING


SIPS SCREW FIXINGS AT 300mm C/C
UNLESS OTHERWISE SPECIFIED BY
PROJECT ENGINEER

SELECTED ROOF CLADDING


ON SELECTED BATTENS
PROVIDE 10mm SHIMS BENEATH
HORIZONTAL BATTENS TO ALLOW
FOR MOISTURE FLOW

SIPS INDUSTRIES PROVIDED


BREATHABLE MEMBRANE.
LAPS OF AT LEAST 150mm.
TAPED LAPS FOR LOW PITCH
ROOFS, LAP MEMBRANE INTO GUTTER

SELECTED
SOFFIT
LINING SIPS INDUSTRIES ROOF PANEL
GENERALLY 175mm THICK R4.4
SEE TECHNICAL SPECIFICATIONS
FOR SPANS AND OTHER INFORMATION

SIPS INDUSTRIES EXTERNAL WALL PANEL


WITH BREATHER MEMBRANE, VERTICAL
BATTENS AND SELECTED CLADDING.
PROVIDE CAVITY VENTILATION PER
SIPS INDUSTRIES SPECIFICATIONS

Detail Title Detail 308 D308


D
DTL No: REV
EAVES DETAIL - Framed Roof

SELECTED ROOF CLADDING


ON SELECTED BATTENS

SARKING OVER RAFTERS


USE TILTING FILLET TO
SUPPORT SARKING

SELECTED GUTTER
AND FASCIA BOARD/PROFILE

TIMBER RAFTER WITH BIRDSMOUTH OVER


WALL PLATE, OR OVER PANEL END

SELECTED SOFFIT LINING DORECT


TO PANEL OR TRADITIONAL ALTERNATIVE
SHOWN DASHED

SIPS INDUSTRIES EXTERNAL WALL PANEL


WITH BREATHER MEMBRANE, VERTICAL
BATTENS AND SELECTED CLADDING.
PROVIDE CAVITY VENTILATION PER
SIPS INDUSTRIES SPECIFICATIONS

Detail Title Detail 309 D309


D
DTL No: REV
RIDGE DETAIL - TYPICAL
Representative
Roof finish

SIPS Screws Staggared


@ 150 c/c

Breather Membrane

175/165 SIPS Roof Panels

Ridge Beam, LVL or Steel


to engineers detail
10mm Packers, or counter battens
allow moisture to pass.

RIDGE DETAIL - HIDDEN RIDGE


Representative
Roof finish

SIPS Screws Staggered


@ 150 c/c

Breather Membrane

175/165 SIPS Roof Panels

Ridge Beam, LVL or Steel


to engineers detail
FOR EASE OF CONSTRUCTION -
10mm Packers, or counter battens TEMPORARILY FIX A TIMBER
LENGTH TO THE UNDERSIDE
allow moisture to pass. OF THE RIDGE BEAM TO REST
THE SIPS ROOF PANEL ON DURING
INSTALL.

Detail Title Detail 310 D310


D
DTL No: REV
VELUX DETAIL - FLAT ROOF (FCM)

VELUX FCM FLAT ROOF WINDOW


FCM 2234 ( 572x877mm) 140x35 UPSTANDING TIMBER

MINIMUM FLASHING DIMENSIONS PURPOSE-MADE FLASHING


MIN 100mm HIGH AND 200mm
UP THE ROOF
SELECTED ROOFING

SIPS INDUSTRIES 175mm 35mm ROOF BATTENS


ROOF PANELS - R4.4
200
100

VELUX FCM SKYLIGHT - FCM 2234


SKYLIGHTIT TO BE FLASHED WITH
PURPOSE-MADE FLASHING IN STRICT
ACCORDANCE WITH THE MANUFACTURERS
DETAILS AND GUIDELINES.

Detail Title Detail 311 D311


D
DTL No: REV
SIPS BARGE DETAIL - TYPICAL

ROOF FINISH PER WORKS


SPECIFICATINO AND ADDENDA
INSTALLED TO MANUFACTURERS
REQUIREMENTS OVER TIMBER BATTENS
INSTALLED TO ENGINEERS SPEC, OVER
10mm WATER EGRESS SHIMS AND
SIPS INDUSTRIES BREATHABLE MEMBRANE

PROFILED COLORBOND
METAL FLASHING

SIPS INDUSTRIES 175 R4.4


ROOF PANEL LINED WITH
PLASTERBOARD INTERNALLY

WALL CLADDING PER FINISHES


SELECTION AND INSTALLED TO
MANUFACTURERS REQUIREMENTS
OVER SIPS INDUSTRIES WALL SYSTEM

Detail Title Detail312 D312


D
DTL No: REV

You might also like