Calculation Sheet Title : RC Girder Design Rev.

: 1

Project : Trestle Roadway Structure Prepared by : IGA Checked by :

Static moment to bottom fiber :

hsb
19018.8 yb = 10,750.00 x ( 180.00 + 21.50 ) + ( 8,268.75 x 89.10 )
19018.8 yb #######
=
yb = 152.63 cm
Cek :
ya + yb = hs + hc
70.37 + 152.63 = 180.00 + 43.00
223.0 = 223.0 O.K.

d. Moment of Inersia Composite Section


a. Equivalnet deck section
Equivalent deck area Ac = 10750.0 cm2
Moment of inertia Ioc = 1/12 x 250.00 x 43.00^3 = 1656396 cm4

Distance from center of equivalent deck section to neutral axis of composite :


d1 = ya - (hc/2) = 70.37 - 21.50 = 48.87 cm
Moment of inersia equivalent deck section from neutral axis of composite
Ic = Ioc + Ac.d12 = 1,656,395.8 + 10,750.0 x 48.87^2 = 27330372 cm4

b. Girder Section
Girder area As = 8268.8 cm2
4
Moment Inersia girder Ios #######
= cm

Distance from center of girder section to neutral axis of composite :


d2 = yb - (hsb) = 152.632 - 89.100 = 63.53 cm
Moment of inersia girder section from neutral axis of composite
Is = Ios + As.d22 = 31,040,357.2 + 8,268.8 x 63.532^2 = 64415839 cm4

Moment of Inersia composite section :


I = Ic + Is = 27,330,372.5 + 64,415,838.9 = 91746211 cm4

Moment of inertia ratio between composite section to girder section


I / Ios = 91,746,211 / 31,040,357 = 2.96