Calculation Sheet
Location : -
Project : - Prepared by : - Checked by : -
Cover cov = 50 mm
Tension Bar Diameter D = 25 mm
d'
Comp Bar Diameter D' = 25 mm As '
a
Mu j 0.85 fc '.ab d As '.fy (d d' )
2
= 0.90 x [ 0.85 x 28.50 x 208.0 x 1,800 x (1,924.0 - 208.0/2 ) ]
+ 0.90 x [ 0.0 x 420.0 x ( 1,924.0 - 75.5 ) ]
= 14856 + 0
Page 14