Handi

4 7 2 6
A B C

Mu = 3AB Mu = 372 kNm


Fc = 3B Fc = 32 Mpa
Fy = 4BC Fy = 426 Mpa
b = 3CA b = 367 mm
h = 6AC h = 676 mm
d = 626 mm
d' = 62.5 mm
cover = 50 mm
c = 90 mm

#1 Calculate c < 0.75 cb

c < 0.75 cb = 0.75 x 600 x d


600 + Fy

= 0.75 x 600 x 626


600 + 426

= 275 mm

#2 Calculate As1 with c determined from above c = 90 mm

Bi = 0.85 - Fc - 30 x 0.05 > 0.65


( 7 )
= 0.85 - 32 - 30 x 0.05 > 0.65
( 7
)
= 0.836

a = Bi x c

= 0.836 x 90

= 75.21 mm

As = 0.85 x Bi x F'c x c x b
F'y

= 0.85 x 0.836 x 32 x 90 x 367


426

= 1762 mm2

#3 Calculate Mn1

Mn1 = As x F'y d - a
( 2 )
= 1762 x 426 626 - 75.21
( 2 )
= 441.78 kNm

#4 Calculate Mn-Mn1

Mu - Mn1 = 372 - 441.777


Φ 0.8

= 23.22 kNm > 0


Perlu Tulangan Tekan

#5 Tulangan Tekan diperlukan, Hitung T2

Cs' = T2 = Mn - Mn1
(d - d') d' = cover + (½D Tul. Tekan)

6
= 23.223 x 10
626 - 62.5

= 41213 N
#6 Kontrol tegangan leleh tulangan tekan

fs = 1 - d' 600
( c )
= 1 - 62.5 600
( 90 )
= 183 Mpa < F'y = 426 Mpa
Tulangan Tekan Belum Leleh

#7 Hitung kebutuhan tulangan tekan

As' = Cs'
( fs' - 0.85 x F'c )

As' = 41213
( 183 - 0.85 x 32 )

As' = 264 mm2

#8 Hitung tulangan tarik tambahan

Ass = T2 = 41213
F'y 426
= 97 mm2

#9 Calculate Required Reinforcement

As = 1762 + 97 mm2

= 1859 mm2 Dipakai 4 D 25 = 1963

As' = 264 mm2 Dipakai 1 D 25 = 491

Check S > 4 cm
As S = b - D
n + 1
S = 367 - 25
4 + 1
S = 4.84 cm > 4 cm
OK

Check S > 4 cm
As' S = b - D
n + 1
S = 367 - 25
1 + 1
S = 15.85 cm > 4 cm
OK

#10 Check The Moment Required

a = As x F'y - As' x fs
0.85 x F'c x b

= 1963 x 426 - 491 x 183


0.85 x 90 x 367

= 74.75 mm

ΦMn = 0.8 x As x F'y - As' x fs x d - a + As' x fs x d - d'


2

= 0.8 x 1963 x 426 - 491 x 183 x 626 - 74.75 + 491 x 183 x 626 - 62.5
2

= 391.97 kNm > Mu = 372 kNm OK