RE 29105
Type 4WREE Edition: 2018-12
▶ Size 6
▶ Component series 3X
▶ Maximum operating pressure 350 bar
▶ Maximum flow 80 l/min
▶ Rated flow 4 … 32 l/min (Δp = 10 bar)
4WREE6_3X
Features Contents
Ordering code
01 02 03 04 05 06 07 08 09 10 11 12 13
4 WRE E 6 – 3X / / 24 *
01 4 main ports 4
02 Proportional directional valve direct operated, with electrical position feedback WRE
04 Size 6 6
Seal material (observe compatibility of seals with hydraulic fluid used, see page 15)
09 FKM seals V
NBR seals M
Supply voltage
10 Direct voltage 24 V 24
Special versions
12 Without pressure compensation element in the OBE no code
With pressure compensation element in the OBE -967
Symbols
A B A B A B A B
a 0 b a 0 b a 0 a 0
P T P T P T P T
E
EA
E1-
W
WA
W1-
V
V1-
Function, section
The type 4WREE valve is a direct operated proportional Valve with 2 spool positions (version "4WREE…A…")
directional valve with electrical position feedback and The function of this valve version basically corresponds
integrated electronics (OBE). to the valve with three spool positions. The 2 spool posi-
tion valves are, however, only equipped with solenoid
Set-up "a" (7). Instead of the 2nd proportional solenoid, there
The valve basically consists of: is a plug screw (10).
▶▶ Housing (1) with connection surface
▶▶ Control spool (2) with compression springs (3 and 4) Pressure compensation element in the OBE "-967"
and spring plate (5 and 6) To prevent condensate formation in the housing of the
▶▶ Solenoids (7 and 8) with central thread integrated electronics (OBE), an electronics protection
▶▶ Position transducer (9) membrane (11) can be used.
▶▶ Integrated electronics (13) Recommended for use outside industry-standard
▶▶ Electric zero point adjustment (12) accessible via the conditions with high ambient air humidity and significant
rubber plug cyclic temperature changes (e. g. outdoors).
Function:
Notes:
▶▶ With de-energized solenoids (7 and 8), central position
▶▶ Due to the design principle, internal leakage
of the control spool (2) by compression springs
is inherent to the valves, which may increase
(3 and 4) between spring plates (5 and 6)
over the life cycle.
▶▶ Direct operation of the control spool (2) by controlling
▶▶ The tank line must not be allowed to run empty.
a proportional solenoid, e.g. solenoid "b" (8)
With corresponding installation conditions, a preload
–– Displacement of the control spool (2) to the left
valve (preload pressure approx. 2 bar) must be
proportional to the electric input signal
installed.
–– This opens the connection from P to A and B to T
▶▶ The PG fitting (14) must not be opened.
via orifice-type cross-sections with progressive
flow characteristic
12 11
13
A T B
14 9 7 3 5 2 (P) 1 6 4 8
Bosch Rexroth AG, RE 29105, edition: 2018-12
Proportional directional valve | 4WREE 5/18
Technical data
(for applications outside these values, please consult us!)
general
Weight ▶▶ Valve with two solenoids kg 2.6
▶▶ Valve with one solenoid kg 2.1
Installation position any, preferably horizontal
Ambient temperature range °C –20 … +60
Storage temperature range with UV protection °C +5 … +40
Transport temperature °C –30 … +80
Maximum storage time Years 1 (if the storage conditions are observed; refer to the operating
instructions 07600-B)
Sine test according to DIN EN 60068-2-6 10 ... 2000 Hz / maximum of 10 g / 10 cycles / 3 axes
Noise test according to DIN EN 60068-2-64 20 ... 2000 Hz / 10 gRMS / 30 g peak / 30 min. / 3 axes
Transport shock according to DIN EN 60068-2-27 15 g / 11 ms / 3 shocks / 3 axes
Shock according to DIN EN 60068-2-27 15 g / 11 ms / 1000 shocks / 3 axes
Maximum relative humidity (no condensation) % 95
Maximum solenoid surface temperature °C 150 (individual operation)
MTTFd value according to EN ISO 13849 Years 150 (for further details see data sheet 08012)
Conformity ▶▶ CE according to EMC directive 2014/30/EU, tested according
to EN 61000-6-2 and EN 61000-6-3
▶▶ RoHS directive 2015/65/EU
▶▶ REACH ordinance (EC) no. 1907/2006
Environmental compatibility ▶▶ Climate Environmental audit according to EN 60068-2
hydraulic
Maximum operating pressure ▶▶ Port A, B, P bar 350
▶▶ Port T bar 210
Maximum flow (recommended) l/min 80
Rated flow (∆p = 10 bar) l/min 4; 8; 16; 32
Hydraulic fluid see table page 15
Hydraulic fluid temperature ▶▶ admissible °C –20 … +70
range ▶▶ recommended –40 … +50
Viscosity range ▶▶ admissible mm2/s 20 … 380
▶▶ recommended mm2/s 30 … 46
Maximum admissible degree of contamination of the class 20/18/15 1)
Technical data
(for applications outside these values, please consult us!)
static /dynamic
Hysteresis % < 0.1
Range of inversion % < 0.05
Response sensitivity % < 0.05
Zero shift upon change of hydraulic fluid temperature %/10 K ≤ 0.15
and operating pressure %/100 bar ≤ 0.1
U
Differential
I
D
Command value amplifier
U/I
E U
Reference potential
Controller
F
Actual value Actual value
U/I U
C U I
Reference potential
Undervoltage
detection
Interlocking
Power supply
unit Oscillator
Supply voltage 24 V A
U +U
B 0V
GND U −U Demodulator
PE
Protective grounding
conductor 1)
Position
Zero point 2) transducer
Notice:
Mating connectors, separate order, see page 16
and data sheet 08006.
Characteristic curves
(measured with HLP46, ϑoil = 40 ±5 °C)
100
80
60
← Pressure differential in % →
40
20
-5 -3 -1 1 3 5
-20
-40
-60
-80
-100
← Command value in % →
Version "V32"
2
Leakage flow in l/min →
Characteristic curves
(measured with HLP46, ϑoil = 40 ±5 °C)
Symbol V
15
5
10 4
3
5 2
1
Flow in l/min →
0
0 10 20 30 40 50 60 70 80 90 100
Symbol E; W
15
5
10 4 1 Δp 10 bar constant
2 Δp 20 bar constant
3
5 2 3 Δp 30 bar constant
1 4 Δp 50 bar constant
5 Δp 100 bar constant
0
10 15 20 30 40 50 60 70 80 90 100
Command value in % →
Symbol V
30
5
20 4
3
2
10
1
Flow in l/min →
0
0 10 20 30 40 50 60 70 80 90 100
Symbol E; W
30
5
20 1 Δp 10 bar constant
4
3 2 Δp 20 bar constant
10 2 3 Δp 30 bar constant
1 4 Δp 50 bar constant
5 Δp 100 bar constant
0
10 15 20 30 40 50 60 70 80 90 100
Command value in % →
Characteristic curves
(measured with HLP46, ϑoil = 40 ±5 °C)
Symbol V
60 5
50
4
40
3
30
2
20 1
10
Flow in l/min →
0
0 10 20 30 40 50 60 70 80 90 100
Symbol E; W
60
50 5
40
4
30
3
2
20 1 Δp 10 bar constant
1 2 Δp 20 bar constant
10 3 Δp 30 bar constant
4 Δp 50 bar constant
5 Δp 100 bar constant
0
0 10 15 20 30 40 50 60 70 80 90 100
Command value in % →
Characteristic curves
(measured with HLP46, ϑoil = 40 ±5 °C)
Symbol V
120
5
100
80 6
4
60 3
2
40
1
20
Flow in l/min →
0
0 10 20 30 40 50 60 70 80 90 100
Symbol E; W
120
100 5
80 6
4
60
3
1 Δp 10 bar constant
40 2
2 Δp 20 bar constant
1 3 Δp 30 bar constant
20 4 Δp 50 bar constant
5 Δp 100 bar constant
0 6 Maximum flow (recommended)
0 10 15 20 30 40 50 60 70 80 90 100
Command value in % →
Notes:
▶▶ Flow values in the maximum command value range
(see tolerance field of the flow/signal function)
▶▶ ∆p = pP – pL – pT
∆p valve pressure differential
pP inlet pressure
pL load pressure
pT return flow pressure
Characteristic curves
(measured with HLP46, ϑoil = 40 ±5 °C)
Transition function with stepped electric input signals (4/3 directional design)
Symbol V; E
Signal change in %
100 0 – 100 – 0
90
80
0 – 75 – 0
70
Stroke in % →
60
50 0 – 50 – 0
40
30
0 – 25 – 0
20
10
0 10 20 30 40 0 10 20 30
Time in ms →
Symbol V
-5 -315
-0 -270
-3
-5 -225
Amplitude ratio in dB →
Phase angle in ° →
-10 -180
-15 -135
-20 -90
-25 -45
-30 0
1 2 3 4 5 6 7 8 910 20 30 40 50 60 80 100 200
Frequency in Hz →
Signal ±10 %
Signal ±25 %
Signal ±100%
Characteristic curves
(measured with HLP46, ϑoil = 40 ±5 °C)
Symbol V
200
100
80 5
Flow in l/min →
4 2
3
1
10 Rated flow
1 4 l/min
2 8 l/min
3 16 l/min
4 32 l/min
5 Maximum admissible flow
1
10 20 50 100 200 300
Pressure differential in bar →
Notice:
If the valve is operated outside the specified power limits for
more than 10 seconds, the solenoid current is reduced by a ramp
in order to avoid overload.
Dimensions
(dimensions in mm)
1 9
10
11
110
8
47.5
42
“a“ “b“
23.5
13.6 8.4
69.2 45
131 Ø45.4 max
195
15 59 255
10 2 5 3 6
15
F1 F2
8
T
0,01/100
A B
Rzmax 4 47
F4
P F3
Required surface quality
of the valve contact surface
72
1 Valve housing
Notes:
2 Proportional solenoid "a" with inductive position transducer
▶▶ The dimensions are nominal dimensions which are subject
3 Proportional solenoid "b" to tolerances.
4 Plug screw for valve with one solenoid (2 spool positions, ▶▶ Mating connectors, separate order, see page 16 and
version "EA" or "WA") data sheet 08006.
5 Identical seal rings for ports A, B, P, and T
6 Machined valve contact surface; porting pattern according
to ISO 4401-03-02-0-05 Notice:
Deviating from the standard: Ports P, A, B, T Ø8 mm The dimensions are nominal dimensions which are subject
to tolerances.
7 Integrated electronics (OBE)
8 Mating connector, separate order, see page 16
data sheet 08006
9 Name plate Valve mounting screws see page 16.
10 Space required for removing the mating connector
11 Pressure compensation element in the OBE "-967"
Dimensions
Notice:
The tightening torque of the hexagon socket head cap screws
refers to the maximum operating pressure.
Control electronics
Type Data sheet
Command value module Analog VT- SWMA-1-1X/... 29902
VT-SWMAK-1-1X/... 29903
Command value card Analog VT-SWKA-1-1X/... 30255
Digital VT-HACD -1-1X/... 30143
Further information
Notes
Bosch Rexroth AG © All rights reserved to Bosch Rexroth AG, also regarding any disposal,
Industrial Hydraulics exploitation, reproduction, editing, distribution, as well as in the event
Zum Eisengießer 1 of applications for industrial property rights.
97816 Lohr am Main, Germany The data specified above only serve to describe the product. No statements
Phone +49 (0) 93 52 / 40 30 20 concerning a certain condition or suitability for a certain application can be
my.support@boschrexroth.de derived from our information. The information given does not release the user
www.boschrexroth.de from the obligation of own judgment and verification.
Please note that our products are subject to a natural process of wear
and aging.
Notes
Bosch Rexroth AG © All rights reserved to Bosch Rexroth AG, also regarding any disposal,
Industrial Hydraulics exploitation, reproduction, editing, distribution, as well as in the event
Zum Eisengießer 1 of applications for industrial property rights.
97816 Lohr am Main, Germany The data specified above only serve to describe the product. No statements
Phone +49 (0) 93 52 / 40 30 20 concerning a certain condition or suitability for a certain application can be
my.support@boschrexroth.de derived from our information. The information given does not release the user
www.boschrexroth.de from the obligation of own judgment and verification.
Please note that our products are subject to a natural process of wear
and aging.
Notes
Bosch Rexroth AG © All rights reserved to Bosch Rexroth AG, also regarding any disposal,
Industrial Hydraulics exploitation, reproduction, editing, distribution, as well as in the event
Zum Eisengießer 1 of applications for industrial property rights.
97816 Lohr am Main, Germany The data specified above only serve to describe the product. No statements