You are on page 1of 2

PILANI ENVIROTECH PVT LTD

121, HAMMERSMITH INDL ESTATE, OFF S. T. ROAD, MAHIM(W), MUMBAI-16,


TELE :022-24448321, E-mail: bharatbagi@pilanienviro.com
To,
HVAX Technologies Pvt Ltd
Mumbai.

Ref : CF-01
DT : 27-06-2022
TO WHOMSOEVER IT MAY CONCERN.

CARTRIDGE FILTER TEST CERTIFICATE FOR 300CFM.


Your PO.NO: 1944/05/2022-23 Dated: 07-05-2022

This is to certify that the filters supplied by us alongwith our dust collector is meeting the following
specifications.
Type : Standard air filter cartridge. Quantity: 03nos (one for each) Total: 3units

Size / CFM : Ø325mm x 300mm long / 300cfm each. Area : 05m2 each.

Filter media : Spun bond Polyester. Mounting : Sideways

Air permeability: 980m3/m2/hr at 200pa.

Weight / colour : 180 gms/m2 / white.

Chemical resistance:

Oil and water : Good.


Acid resistance : Good.
Alkaline resistance : Fair.

Initial Pressure Drop : less than 20mmwc Normal : 80mmwc Chocked: 100mmwc

Filtration Efficiency : 99% down to 3micron.

We hereby declare that the above mentioned information is true and correct.
Thanking you,

For Pilani Envirotech Pvt Ltd

Authorised Signatory.
PILANI ENVIROTECH PVT LTD
121, HAMMERSMITH INDL ESTATE, OFF S. T. ROAD, MAHIM(W), MUMBAI-16,
TELE :022-24448321, E-mail: bharatbagi@pilanienviro.com
To,
HVAX Technologies Pvt Ltd
Mumbai.

Ref : BL-01
DT : 27-06-2022
TO WHOMSOEVER IT MAY CONCERN.

BLOWER TEST REPORT FOR 300CFM


Your PO.NO: 1944/05/2022-23 Dated: 07-05-2022

This is to certify that the blowers supplied by us is meeting the following specifications:
Type / Qty : Backward Curved Centrifugal

Application : For Dust Collector.

Capacity : 300cfm.

Qty : 03nos.

Static pressure : 350mmwc.

Drive : Direct.

Motor HP : 1.5HP-415v-50Hz-3ph (Non-FLP)

RPM : 2850.

MOC : Casing & Impeller in MS Epoxy Painted.


NOTE:

1) The blowers are tested as per IS-4894.

We hereby declare that the above mentioned information is true and correct.
Thanking you,

For Pilani Envirotech Pvt Ltd

Authorised Signatory.

You might also like