You are on page 1of 2

Birla Institute of Technology & Science, Pilani

Pilani | Dubai | Goa | Hyderabad

Work-Integrated Learning Programmes Division

(EC-1 Virtual Lab Assignment)


Course No. : ENGG ZC112 / PE ZC 112
Course Title : ELECTRICAL AND ELECTRONICS TECHNOLOGY

Instructions:
➢ The Unsolved assignment has a weightage of 10 (5+5) Marks and needs to be
attempted on the evaluation version of multisim on your local systems, no slot
booking is required.
➢ You must attempt both the problems.
➢ Its mandatory to mention your Name, BITS ID and result analysis in the Multisim
workspace.
➢ You need to take three Screenshots while attempting the unsolved assignment
and paste the same uncropped Screenshots to your report and then upload it on
the elearn portal for evaluation. Cropped Screenshots will lead to the loss of
marks. The Screenshots should be taken as follows:
• First Screenshot: After placing all components instruments on the
workspace
• Second screenshot: After making all component connections
• Third Screenshot: Should be Results (VALUES, GRAPHS etc.)
➢ The first page of the report should be hall ticket. The report format should be in
pdf/ ppt / word.
➢ Upload the report in elearn portal in folder created with name Lab Assignment-2
➢ Marks will be deducted in case anything is found missing from the above
mentioned required details.
➢ Fill the required details in the Google form and submit your response. Single
responses will be recorded.
Form link: https://forms.gle/uCjxUcR2wZeZxkb99

Q1
Using Multisim software implement the circuit to measure line currents in t h e
three phase AC system having a Star connected Alternator connected to a Star
connected load having impedances of
𝒁𝑹 = (𝟏𝟎. 𝟓 + 𝒋 𝟖. 𝟓𝟕𝟏) Ω
𝒁𝒀 = (𝟏𝟒. 𝟐 − 𝒋 𝟔. 𝟓𝟕𝟏) Ω
𝒁𝑩 = (𝑹)
R in the above impedance is the last three digits of your bits id (example for the student
with bits id : 202318bt416@wilp.bits-pilani.ac.in the value of R=416 Ω)
Birla Institute of Technology & Science, Pilani
Pilani | Dubai | Goa | Hyderabad

Use wattmeter functionality to measure the three phase Power. The phase voltage of
the Alternator is 230V(RMS) with frequency of 50Hz.
The report should include the following

Line
S NO
Current
1 𝑰𝑹 =
2 𝑰𝒀 =
3 𝑰𝑩 =
Total Power consumed in the Load = Kw

Q2
Connect an impedance 𝒁𝟏 = (𝟏𝟎. 𝟓𝟏𝟔 + 𝒋 𝟔. 𝟓𝟕𝟏) Ω in series with 𝑽𝟏 = (𝟐𝟏𝟔. 𝟑𝟔 +
𝒋𝟓𝟕. 𝟗𝟕) 𝑽 to form the first branch, the second branch is 𝒁𝟐 = (𝟏𝟏. 𝟎𝟑𝟏 − 𝒋 𝟏𝟏. 𝟎𝟑𝟏) Ω
in series to 𝑽𝟐 = 𝟐𝟒𝟖∠𝟑𝟓° 𝑽𝒐𝒍𝒕𝒔, the third branch has 𝒁𝟑 = (𝑹 + 𝒋 𝟕. 𝟓) Ω.
R in the above impedance is the last three digits of your bits id (example for the student
with bits id : 202318bt416@wilp.bits-pilani.ac.in the value of R=416 Ω)
These three branches are connected in parallel with each other. Using Multisim
application implement the circuit to measure current in each branch of the circuit.
The supply frequency is 50Hz.
The report should include the following

Branch Current
1 𝑰𝟏 =
2 𝑰𝟐 =
3 𝑰𝟑 =
--------

You might also like