You are on page 1of 1

Format No.

FM/QAC/04
Rev No. 0
PHYSICAL TEST / LAB TEST REPORT
Date 01.05.2014

Cable Name HAND THROTTLE PUSH PULL CABLE Part No. 300488179A Test Date 14.02.24 Test Name Pull-off Load Testing

OBSERVATION (in Kgf)


Sl.No. Parameter Operation Specs Equipment / Instrument Tol STATUS
1 2 3 4 5

1 OUTER Pull-off Load test 20 kgf TENSILE TESTING MACHINE Min. 170 165 OK

2 INNER Pull-off Load test 250 kgf TENSILE TESTING MACHINE Min. 284 280 OK

TESING METHOD : FIX ONE END AND PULL ANOTHER END UNTIL SEPARATION.
TEST PHOTOS:

FIX END

MOVING
END

TENSILE TESTING MACHINE

REMARKS IF ANY

TESTED BY NPD HEAD