You are on page 1of 21

Contents

Preface ......................................................................................................................................................1
Basic Introduction ..................................................................................................................................2
Treatment Theory .............................................................................................................................2
Application .......................................................................................................................................3
Advantages .......................................................................................................................................3
Technical Specification ...................................................................................................................4
Contraindications .............................................................................................................................4
Security Considerations.........................................................................................................................5
Fire Prevention .................................................................................................................................5
Electric Protection ...........................................................................................................................6
Eye Protection ..................................................................................................................................6
Installation Instruction ..........................................................................................................................7
Accessories .......................................................................................................................................7
Details on Host Machine .................................................................................................................8
Installation Steps..............................................................................................................................9
Installed Machine...........................................................................................................................10
Operation Instruction ..........................................................................................................................11
Details on Screen ...........................................................................................................................11
Operation Steps..............................................................................................................................12
Notice for Operation ......................................................................................................................14
Before Operation ...................................................................................................................14
During Operation ..................................................................................................................14
After Operation .....................................................................................................................15
Recommended Parameters ............................................................................................................14
Other Information................................................................................................................................18
Storage ............................................................................................................................................18
Transport ........................................................................................................................................18
Maintenance ...................................................................................................................................19
Warranty .........................................................................................................................................19
Preface

Important Info

This user manual contains important information about the use and operation of
this machine. Read all information carefully for optimum performance and to
avoid any damage or misuse of the machine. Any changes or modifications not
expressly approved in this user manual shall void the warranty of this
equipment.

Female would like to match their perfect figure with white skin especially in
summer, so most of them may try to remove their exposed thick hair through
some ways like using creams, waxing and pulling which are convenient and
economical, but only experience rapid rebound after one or more than one course
of treatment.

With its safety and fast result, three-wavelength diode laser hair removal machine
is popular among people who pursue beauty. Under such condition, numbers of
beauty salons are willing to help their patients solve hair problems by putting this
equipment into use.

1
Basic Introduction

Treatment Theory

755nm 1064nm
808nm: Suitable for
almost all hair
types, the 808nm
755nm: The 755nm can penetrate into 1064nm: Because
is characterized by the subcutaneous the 1064nm
more powerful fat tissues as well possesses the
melanin absorption, as deep dermis so features of lower
making it suitable as to act on various melanin absorption
for the light-colored body parts, making yet deeper
and thin hair. In this hair removal at any penetration in
way, this depth realized in an follicles, it mainly
wavelength aims to express and provides solutions
remove the hair on thorough way. for dark hair color.
such areas as In other words, this
eyebrows, upper lip, longest wavelength
etc. focuses on the
treatment areas like
scalp, armpits,
bikini line, etc.

808nm

This machine adopts selective thermodynamic theory, enabling energy to be


absorbed by the melanin in follicles whose temperature rises instantly. As a
result, the follicles, hair shaft and the supporting organization of stem cells
around them are damaged, which fundamentally prevents the development of
inelegant “fur” so as to achieve the goal of permanent hair removal.

2
Application
Remove the
hair on

Legs Back Ches


t

Abdomen Armpits Bikini line

Advantages

❖ The 15*15mm large square spot not only is capable of eliminating treatment
dead zone of traditional round one but also has high efficiency, fast speed and
larger treatment area.

❖ Since laser can penetrate deep into hair follicles, energy loss can be prevented.

❖ It is so safe and comfortable that patients can have a relaxing experience.

❖ The treatment time is shortened on account that its velocity is about four or five
times faster than normal machine.

❖ This machine covers more comprehensive functions due to its three


wavelengths, 755nm for light thin hair, 808 for both light and dark and 1064 for
dark.

3
Technical Specification

Power 2500W
Laser type Diode laser
Wavelength 755nm+808nm+1064nm
Screen size 10.4 inches
Spot size 15*15mm
Electricity 220/110V, 50/60HZ
Cooling System Air+Water +Semiconductor
Water volume 4L
Fluence 0~120J/cm2
Laser Power 5%~100%
Frequency 1~10HZ
Pulse width 5~400ms
Packed size 65*46*54cm
Gross weight 30kg

Contraindications

※ People who have diseases such ※ People who are planted


as heart diseases, mental with pacemaker, steel
diseases, epilepsy, diabetes, nails or other metals.
etc.
※ People who have taken
※ Children who are under seven medicine like antibiotics
years old. (Notes: Children who and anticoagulant in a
are above the age should ask for long time.
medical advice.)
※ People who have physical
※ Women in pregnant, lactation scar.
or menstrual period.
※ People who have received
※ People with malignant lesions plastic surgery should
on the treatment area. follow medical orders.

4
Security Considerations

Warning

This machine is a precise equipment merely used for medical


application. Passing strict security detection before delivery, this
system won’t have any accident under normative operation. Therefore,
please read this chapter and others concerned carefully so as to protect
the personal safety of operators and patients.

Fire Prevention

❖ Instead of any other people, the


Medical medical staff responsible for this
staff operation should control the output of
laser.

❖ Prevent laser beam from getting close


to combustible, anesthetic or other
inflammable solvent.
Inflammable

❖ Paper and plastic are forbidden to put


near to the work area of this machine, Paper
because considerable absorption of Plastic
energy may lead to the burning of
these materials.

❖ Switch the state of this machine to


“STANDBY” when it’s not in use.
STANDBY

5
Electric Protection

❖ Keep the workshop where this machine is put clean and dry, and make sure there is
no dripping or vapour at startup.
❖ This beauty equipment can only be maintained and repaired by the technical
engineers of our company. Any consequence caused by unauthorized disassembly is
beyond our responsibility.
❖ Please make sure the machine is well earthed at using.
❖ To avoid dangerous output in abnormal condition, current-limiting setting is done
before delivery.

If any abnormal state appears, the system will show malfunction failure immediately
and close all power supplies after sounding an alarm, under which circumstance, you
can turn on power to restart it. If the malfunction still exists, please contact the
manufacturer or the appointed agent instantly.

Eye Protection

❖ It’s forbidden to directly observe the


laser beam that reflected or scattered
after radiation. Otherwise, the damage
to retina may be caused.
❖ NOHD refers to that the irradiance dose
is less than the distance of relevant MPE
(maximum permissible exposure). If it’s
not for intentional observation, the
NOHD value of this machine is about
5m.
❖ The place where safety goggles are
placed should have highlighting marks,
which can ensure all staff including the
patient takes protective measures to
prevent their eyes from being harmed.

6
Installation Instruction

Accessories

Picture Item Quantity

Hand piece 1

Support rod 1

Goggles for operator 1

Eye shade for patient 1

Water funnel, tube and


1
connector

Power line 1

Fuses 2

Screws 3

7
Details on Host Machine

1 LCD screen 1 Slot for power line

2 Slot for start key 2 Ventilator

3 Urgent stop button 3 Water inlet

4 Slot for hand piece 4 Spilt water

5 Holes for support rod 5 Water outlet

8
Installation Steps

Step 1: Add water

1) Connect water funnel, 3) Twist off the cap of “water inlet”,


connector and tube together. and insert what’s connected in
2) Twist off the cap of “spilt “1)” onto it.
water” and put a container 4) Inject the funnel with purified or
under it. distilled water.
(Don’t stop injecting until there is
water flowing out from “spilt water”. )

Step 3: Install support rod

1) Align the three holes as shown above.


2) Choose three screws from the accessories and screw them tightly
by a screw driver.

9
Step 4: Install Step5: Install power
hand piece line

1) Put the treatment head


onto the support rod. Insert one end of the power
line into socket and the other
2) Insert the other end into into the slot at the back of host
the slot at the front of host machine.
machine.

Installed Machine

10
Operation Instruction

Details on Screen

Main interface

Treatment
interface

Different signs correspond to different meanings


1 Machine ID 9 Laser power
2 Water flow of hand piece 10 Pulse width
3 Temperature 11 Frequency
4 Dotting number 12 Click to get ready
5 Cooling sign 13 End the treatment
6 Gender of patient 14 Turn down parameter
7 Energy density 15 Turn up parameter
8 Treatment area 16 Back to main interface

Turn up or down, 5/step for laser power and pulse width, 1/step for frequency.

11
Operation Steps

♪ Find the black master switch


below power line at the back of
host machine and press it down.

♪ Screw the urgent stop button


(EMERGENCY) according to
the indicated direction of arrow,
without which step normal
starting up cannot be realized.

♪ Screw the start key to open the


machine.

♪ Click “755nm Hair


Removal”, “808nm Hair
Removal” or “1084nm Hair
Removal” to choose the
wavelength you need and
enter corresponding
treatment interface.

♪ Click to choose
patients’ gender.

♪ Click “A”, “B”, “C”, “D” or “E” to


choose treatment area in
accordance with patients’ reality.
A refers to neck, B to waist, C to hip, D
to legs and E to arms.

♪ Adjust parameters referring to


those recommended in the next part
or according to the personal feeling
of patient. (It’s best when the
patient has a slight tingling
sensation.)
The way to adjust parameters is as
follows: Click the triangle beside the
parameter needed adjusting to turn it up
or down.

12
♪ Apply cooling gel for about
3mm thick on targeted area.

♪ Put on the black eye shade


for the person who are ready
to receive operation.

♪ Wear the protective goggles for


the operator himself/herself.

♪ Click “READY” on the screen


to make the machine get into
operating state.
Only when the background of
“READY” turns to red can the
operator begin the treatment.

♪ Place the probe on treatment area,


after which press the button on
hand piece and move back and
forth to begin the treatment.

♪ After the treatment is completed,


release the button on hand piece,
click “STANDBY” on screen and
screw the start key.
When the operation comes to an end,
clean the treatment head and put it back
onto its original place.

13
Notice for Operation

Before Operation

❖ Please read through this manual ❖ Avoid taking photosensitive


carefully and know exactly every medicine and Chinese medicine
step of the operation procedures. before operation.
❖ It is suggested that this machine ❖ Take sun protection measures
should be operated in a separated within three or four weeks
room. before operation.
❖ Drinks and medicine are ❖ Make sure the protective
forbidden within three days goggles for operator and patient
before operation and two weeks are prepared.
after operation so as to avoid
hemorrhage. ❖ Please clean the treatment area
and shave the hair on it before
❖ Only the professionals are operation.
qualified to operate this machine.
❖ People who have received local
❖ Remove all the jewelry before operation within a month should
operation. ask for medical advice at first.

During Operation

❖ Make sure the power switch is ❖ The laser mustn’t


pressed down and the urgent continuously radiate to the
stop button is lifted. same treatment area, or the
❖ Cooling gel must be applied skin tissues will be damaged
on the treatment area. because of heat accumulation.

14
❖ The continuous working time ❖ The treatment head should be
of this machine shouldn’t placed close to skin
exceed two hours, eight hours perpendicularly and the
a day at most. treatment button should
always be pressed by hand.
❖ Any abnormal phenomenon
during operation, please stop ❖ The foot pedal plays the same
the treatment and press the role as the treatment button on
urgent stop button down. hand piece.

❖ It is normal that redness and ❖ The laser is prohibited to be


swelling appear on the exposed to non-treatment area.
treatment area.

After Operation

❖ It is normal and temporary that ❖ Avoid chemical or mechanical


there appear slight stimulation for 7 days before and
post-operative redness or after treatment.
swelling for which cold
compress is helpful. ❖ Avoid direct sunlight after
treatment, better to use the
❖ Since individual differences and sunscreen cream whose SPF is
climate change exist, please no less than 15.
keep targeted area dry so as to
prevent inflammation. ❖ Hot baths, massage and aerobic
exercises are prohibited.
❖ Not only spicy food but also ❖ After treatment, there may
alcohols and cigarettes are
appear slight bleeding and
forbidden after operation.
scabbing which will fall off
naturally in several days and
❖ Use natural moisturizing shouldn’t be torn up by hand.
products instead of cosmetics.

15
Recommended Parameters

White skin

Treatment area Pulse width Frequency Course

Chest 10~30ms 7~9HZ


Underarms & bikini 20~40ms 5~7HZ
Women’s legs & black hair 5~20ms 6~8HZ
Lips 10~30ms 7~9HZ
Arms & light hair 10~30ms 7~9HZ 3~5 times

Men’s back 5~20ms 8~10HZ

Men’s abdomen 1~10ms 8~10HZ


Men’s beard 10~30ms 7~9HZ
Back 10~30ms 7~9HZ

Yellow skin

Treatment area Pulse width Frequency Course

Chest 30~50ms 3~5HZ


Underarms & bikini 40~60ms 1~3HZ
Women’s legs & black hair 20~40ms 4~6HZ

Lips 30~50ms 3~5HZ


3~5 times
Arms & light hair 30~50ms 3~5HZ

Men’s back 20~40ms 4~6HZ

Men’s abdomen 10~30ms 7~9HZ


Men’s beard 30~50ms 3~5HZ
Back 30~50ms 3~5HZ

16
Brown skin

Treatment area Pulse width Frequency Course

Chest 50~70ms 1~2HZ


Underarms & bikini 60~80ms 1~2HZ
Women’s legs & black hair 40~60ms 2~4HZ
Lips 50~70ms 1~2HZ
Arms & light hair 50~70ms 1~2HZ

Men’s back 40~60ms 1~2HZ


Men’s abdomen 30~50ms 3~5HZ 3~5 times

Men’s beard 50~70ms 1~2HZ


Back 50~70ms 1~2HZ

Note: For all skin colors and body parts, please adjust the “Laser Power” on treatment
interface to 90%-100%.

Black skin

Treatment area Pulse width Frequency Course

Chest 60~80ms 1~2HZ


Underarms & bikini 70~90ms 1~2HZ
Women’s legs & black hair 50~70ms 1~2HZ
Lips 60~80ms 1~2HZ
Arms & light hair 60~80ms 1~2HZ

Men’s back 50~70ms 1~2HZ

Men’s abdomen 40~60ms 1~3HZ 3~5 times

Men’s beard 60~80ms 1~2HZ


Back 60~80ms 1~2HZ

17
Other Information

Storage

❖ Put the machine in an ❖ If the humidity is too high,


operation or treatment room there will appear moisture
with the temperature of condensation inside the
1-40℃. equipment, which probably
affects the efficiency of optical
❖ Dust may lead to the system or damages the
irreversible damage of internal machine devices in severe
optical components, so please case. Therefore, please make
pay essential attention to the sure it’s no more than 75%
sanitary environment of during operation or in storage.
storage room. ❖ Put the machine in the place
❖ The machine mustn’t be stored where children cannot reach.
near thermal source or in the ❖ If the machine won’t be used
place with direct sunlight. for a long time:

❖ Belonging to precise electronic ➢ Cover it with a bag or a piece of


instrument, this machine cloth to prevent moisture and dust.
➢ It’s better to power the machine on
mustn’t be stored in moist
for 1 hour every 15 days for fear of
place. the aging of internal electronics.
➢ Cut off the power supply and dry
❖ Prevent collision, squeeze or the machine thoroughly.
vibration in storage. ➢ Remove the accessories and keep
them individually.

Transport

❖ Make sure the machine is ❖ Do not move or transport it


absolutely dry before without dust proof packaging.
transport.
❖ Protect it from shake and
❖ During the whole process of severe collision during
transportation, the transport to ensure the machine
temperature should be in the and electronic devices function
range of 1-40℃ and the as well as they should do.
humidity no more than 75%.

18
Maintenance

❖ It’s forbidden to use alcohol ❖ Make sure not to let water or


or other inflammable to clean other liquid infiltrate inside the
or disinfect the treatment machine or hand piece during
head. maintenance.
❖ Generally, this machine ❖ After each operation, clean the
should be cleaned and treatment head and put it back to
maintained at fixed period. the original place.
❖ Please turn off the machine ❖ It’s forbidden to wipe this
and disconnect power supply medical beauty equipment with
before maintenance. chemicals.
❖ Use cleanser essence and ❖ Take the handle instead of any
clean cloth instead of the other places. Bringing the output
substance with strong acidity line up at random may cause the
or alkalinity to clean the looseness of internal connector
surface of this beauty and lead to short circuit.
apparatus.

Warranty

All products are strictly tested Malfunctions caused by the following


before sale. A 2-year guarantee of factors are out of the warranty:
free repair is provided starting
from the purchasing day, during
❖ Malfunctions caused by artificial
which time the maintenance for
factors like improper movement,
any breakdown due to
collision, etc.
non-artificial factors will be
performed free of charge. ❖ Malfunctions caused by
Accessories are not included in uncontrollable natural force.
the warranty, so please contact us ❖ Abuse operation that is against
if they are needed. the manual, like connecting
wrong VAC input or using the
The standard of the operation machine for other purposes.
process and the environment ❖ Energy diminishing caused by
should be in accordance with all wet environment or dust.
the instructions above.

19 ◆

You might also like