UNIT 1-Lecture 2 Armature Voltage Control, Starting and Bracking Operation of DC Drives
UNIT 1-Lecture 2 Armature Voltage Control, Starting and Bracking Operation of DC Drives
UNIT 1
Armature Control , Starting and braking operation of
DC motor
Dr.P.Karpagavalli
Professor(CAS)/EEE
Government college of Engineering, Salem-11
Speed Control of DC motor
Armature voltage
Braking
1. Regenerative Braking
2. Dynamic Braking or Rheostat braking
3. Plugging or Reverse voltage braking
Starting
𝐸𝑏 = V − 𝐼𝑎 𝑅𝑎 -----------------------------(1)
𝐼𝑎 𝑅𝑎 = V − 𝐸𝑏
V − 𝐸𝑏
𝐼𝑎 =
𝑅𝑎
Braking
1. Regenerative Braking
2. Dynamic Braking or Rheostat braking
3. Plugging or Reverse voltage braking
Regenerative Braking
𝐸 > 𝑉 𝑎𝑛𝑑 𝑁𝑒𝑔𝑎𝑡𝑖𝑣𝑒 𝐼𝑎
Generated energy is supplied to the source.
Flux cannot be increased substantially
Regenerative braking is possible only for Speed higher than
rated value
With variable voltage it is also possible below rated speed.
In DC series motor , regenerative braking is not
possible.
Solution
Calculate internal voltage of variable voltage source when motor is operating in regenerative braking at