PLATE NO. 5
GRAVITY ANALYSIS OF
FRAME
DE JESUS, CYRHILLE, V.
201510921
TAN, JAMAICA
201812666
DESIGN CRITERIA
ARCHITECTURAL
ARCHITECTURAL
ARCHITECTURAL
ARCHITECTURAL
ARCHITECTURAL
ANALYSIS ALONG GRID 2
ROOFDECK:
I. Span No.1
P=6.732 kN/m
II.Span No. 2
A. DUE TO SLAB:
DL= 19.53 x 3.334 = 65.113 kN/m
LL= 7.6 x 3.334 = 25.338 kN/m
W1= DL+ LL= 90.451 kN/m
B. DUE TO WALL:
W2=2.2497+2.695+0.437= 5.382 kN/m
Wt= W1 + W2= 95.833 kN/m
III.Span No.3
A. DUE TO SLAB:
DL= 19.53 x 3.334 = 65.113 kN/m
LL=7.6 x 3.334 + 1.9 x 3.334= 31.673 kN/m
W1= DL+ LL= 96.786 kN/m
B. DUE TO WALL:
W2=2.2497+2.695+0.437= 5.382 kN/m
Wt=W1+W2=102.168kN/m
ANALYSIS ALONG GRID 2 & GRID 3
ANALYSIS ALONG GRID D
ROOFDECK:
I. Span No.1
P=6.732 kN
II.Span No. 2
A. DUE TO SLAB:
DL= 15.915 x 2.5 = 39.788 kN/m
LL=7.6 x 2.5= 19 kN/m
W1=DL+LL= 31.525 kN/m
B. DUE TO WALL:
W2=5.604 x 2.5 = 14.01 kN/m
Wt=W1+W2 =45.535 kN/m
ROOFDECK:
I. Span No.1
P=6.732 kN
II.Span No. 2
A. DUE TO SLAB:
DL= 15.915 x 2.5 = 39.788 kN/m
LL=9.5 x 2.5= 23.75 kN/m
W1=DL+LL= 63.538kN/m
B. DUE TO WALL:
W2=5.604 x 2.5 = 14.01 kN/m
Wt=W1+W2 =45.535 kN/m
A. DUE TO SLAB:
DL=15.915x2.5=39.788kN/m
LL=7.6 x 1.25+1.9x1.25=11.875kN/m
W1=DL+LL= 51.663 kN/m
B. DUE TO WALL:
W2=5.60 x2.5= 14.01kN/m
Wt=W1+W2 =65.673kN/m
ANALYSIS ALONG GRID C