You are on page 1of 1

FORMATE NO: RIS/SIR/010-REV.

01
RIKSONS CUSTOMER / SUPPLIER DATE : 10-Mar-24
INSPECTION
SERVICES INSPECTION REPORT INSPECTOR NAME: ANSAR MULLA
REPORT NO: AM-132
CUSTOMER: AR Wilfely India Pvt Ltd
SUPPLIER : The Sky Industries, Tilawani-Kolhapur
HEAT No.: PART NO- TSI/WILFELY/24/BF/50 & 51-MAR
PART DETAILS : A7-SS BASE FRAME 398 FOR 315ML MOTAR DRG. NO: ZBPA7398-315ML-SS REV.00
PO NO / LINE : 2224/SKY/1 LN 3 GRADE : SS 316
OFFER INSPECTED ACCEPTED REWORK REJECT
PO QTY. REASON FOR REWORK / REJECTION
QTY QTY. QTY. QTY. QTY.
Dimensional; fillet weld leg size rework;
2 2 2 - 2 -
Visual Inspection pending

Inspection Summery / details as below,


# Rework Points / General Comments / Visual Rework Point :- REMARK
1. Depth 53 [-1.0] is observed as 1) 51.16/52.36; 2) 51.24/ 51.95 mm Rework
2. 4X M20 Tapping gauge not entered Rework
3. 6x M24 Tapping gauge not entered Rework
4. Fillet Weld- leg size 10 mm required actual observed 6-7 mm at found pump & motar base pad Rework
5. Documents Review - MTC Balance
6. Visually not checked due to asthetic work not done Balance
7. GD & T not offered during Inspection FYI
8. After welding leg rework , Re-check again rework related area of dimension Re-check

# DEVIATION POINTS / CONCESSION REQUEST:- REMARK

NIL

TICK AS ''√ '' > √


FINAL INSPECTION REMARKS :
UNDER REWORK UNDER DEVIATION CLEARED FOR DISPATCH

CUSTOMER / SUPPLIER QA FOR RIKSONS INSPECTION SERVICES