You are on page 1of 3

BOSCH EP test values diesel fuel-injection equipment Page: 1

Test date 12/18/2023 Time: 10:01:09 AM Job. no.: ____________________


Customer ID No.
Serial no.: ____________________

ASSEMBLY UND CUSTOMER DATA

ASSEMBLY DATA
Edition 27.01.97
Combination no. 0 400 464 119
Fuel-injection pump
Pump designation PES4A75D410/3RS1255
EP type number 0 410 474 966
Governor
Controller designation RSV325...1400A8C495L
Controller type number 0 420 232 302

CUSTOMER DATA
Customer KHD
Engine F4L912

TEST PREREQUISITES
CAT Designation Unit Set value min. max. Actual values OT
Test oil ISO 4113
Inlet line 1.3
Calibrating oil inlet temp. °C 40 38.0 42.0
Overflow restrictor (type number) 1 419 992 198
Inlet press. bar 1.5 1.5 1.5
Test nozzle holder assembly 0 681 343 009
Opening pressure bar 173.5 172.0 175.0
Test pressure line 1 680 750 014
Outside diameter mm 6.0
x Inside diameter mm 2.0
x Length mm 600

INJECTION PUMP SETTINGS


START OF DELIVERY
CAT Designation Unit Set value min. max. Actual values OT
D Test pressure bar 26.0 25.0 27.0
D Rack travel mm 10.50 9.00 12.00
S Prestroke (as of BDC) mm 1.95 1.90 2.00
C Prestroke (as of BDC) mm 1.95 1.85 2.05
Cam sequence 1- 3- 4- 2
Port-closing difference °NW 0-90-180-270
S Tolerance °NW +- 0.50
Cylinder 1 °NW 0
Cylinder 3 °NW 90 89.5 90.5
Cylinder 4 °NW 180 179.5 180.5
Cylinder 2 °NW 270 269.5 270.5
C Check tolerance °NW +- 0.75

BASIC SETTING
CAT Designation Unit Set value min. max. Actual values OT
SETTING
D speed rpm 1400 1400
D Rack travel mm 10.20 10.15 10.25
S Delivery cm3/1000S. 44.0 42.5 45.5
S Spread cm3/1000S. 3.5
D speed rpm 325 325
D Rack travel mm 9.00 8.90 9.10
S Delivery cm3/1000S. 11.0 9.5 12.5
S Spread cm3/1000S. 4.0

SETTINGS FOR INJECTION PUMP WITH GOVERNOR


CAT = Category (D = Default, S = Setting value, C = Check value)
OT = Outside Tolerance (X is set)
BOSCH EP test values diesel fuel-injection equipment Page: 2

Customer ID No.
Combination ID No. 0400464119

SLIDING SLEEVE TRAVEL/POSITION


CAT Designation Unit Set value min. max. Actual values OT
GUIDE SLEEVE POSITION
D Control lever position ° -3 -3
D speed rpm 800 800
S Rack travel mm 0.50 0.30 0.70
D Governor spring pre-tension click setting x 5.50 5.50

FULL-LOAD DELIVERY
CAT Designation Unit Set value min. max. Actual values OT
D speed rpm 1400 1400
D Aneroid pressure hPa 0 0
S Delivery cm3/1000S. 44.0 42.5 45.5
C Delivery cm3/1000S. 44.0 41.0 47.0
S Spread cm3/1000S. 3.5
C Spread cm3/1000S. 7.0

FULL-LOAD SPEED REGULATION/ASSEMBLY GOVERNOR


CAT Designation Unit Set value min. max. Actual values OT
D Control lever position ° 119.0 115.0 123.0
FULL-LOAD SPEED REGULATION
D Rack travel mm 9.20 9.20
S speed rpm 1445 1440 1450
D Rack travel mm 4.00 4.00
S speed rpm 1485 1470 1500
D Rack travel mm 0.85 0.30 1.40
S speed rpm 1700
D Rack travel mm 4.00 4.00
S speed rpm 1495 1480 1510

IDLE
CAT Designation Unit Set value min. max. Actual values OT
D Control lever position ° 70.0 66.0 74.0
IDLE WITHOUT AUXILIARY SPRING
D speed rpm 325 325
S Rack travel mm 8.50 8.40 8.60
TESTING
D speed rpm 325 325
S Rack travel mm 9.00 8.90 9.10
D Rack travel mm 2.00 2.00
S speed rpm 700 670 730

TORQUE CONTROL
CAT Designation Unit Set value min. max. Actual values OT
D speed rpm 1400 1400
S Rack travel mm 10.20 10.15 10.25
C Rack travel mm 10.20 10.15 10.25
D speed rpm 500 500
S Rack travel mm 11.55 11.50 11.60
C Rack travel mm 11.55 11.50 11.60
D speed rpm 955 955
S Rack travel mm 10.90 10.80 11.00
C Rack travel mm 10.90 10.80 11.00

STARTING FUEL DELIVERY


CAT Designation Unit Set value min. max. Actual values OT
D speed rpm 100 100
D Rack travel mm 20.25 19.50 21.00
S Delivery cm3/1000S. 110.0 102.5 117.5
C Delivery cm3/1000S. 110.0 100.0 120.0

CAT = Category (D = Default, S = Setting value, C = Check value)


OT = Outside Tolerance (X is set)
BOSCH EP test values diesel fuel-injection equipment Page: 3

Customer ID No.
Combination ID No. 0400464119

IDLE DELIVERY
CAT Designation Unit Set value min. max. Actual values OT
D speed rpm 325 325
S Delivery cm3/1000S. 11.0 9.5 12.5
C Delivery cm3/1000S. 11.0 7.5 14.5
S Spread cm3/1000S. 4.0
C Spread cm3/1000S. 6.0
CAT = Category (D = Default, S = Setting value, C = Check value)