You are on page 1of 6

RATINGS FOR NATURAL, ENVIRONMENTAL AND PHYSICAL FACTORS

1. ROAD ACCESSIBILITY CRITERIA

Accessibility is essential upon considering the site since it would affect the outbound and
inbound delivery of raw materials and processed goods.

PERCENTAG RANK CRITERIA EVALUATION


E

100 5 The site is accessible to public and private vehicles and is near to
terminals, ports or airports.

80 4 The site is accessible to public and private vehicles and is distant


to terminals, ports or airports.

60 3 The site is accessible to selected public vehicles, and private


vehicles and is distant to terminals, ports or airports.

40 2 The site is accessible to private vehicles and has no access to


terminals, ports or airports.

20 1 The site is accessible only to small private vehicles such as


motorcycles

2. SOIL CRITERIA

PERCENTAGE RANK CRITERIA EVALUATION

100 5 Stable rock composition

75 4 Mostly stable with non-cohesive soil

50 3 Some unstable areas with cohesive soils

25 2 Unstable soil with organic soil

20 1 Very unstable

3. EXISTING VEGETATION IN THE AREA

PERCENTAG RANK CRITERIA EVALUATION


E
100 5 EXCELLENT, the area has high vegetation density and appears to
be undisturbed

80 4 GOOD, the area as an acceptable vegetation density given that


there is a little signs of disturbance

60 3 MANAGEABLE, the area shows signs of disturbance yet it is still


manageable

40 2 POOR, the area is covered with little vegetation and has shown a
sign of disturbance from natural or man-made activities

20 1 VERY POOR, the area has no vegetation present in the area


4. FUTURE EXPANSION CRITERIA

PERCENTAG RANK CRITERIA EVALUATION


E

100 5 The site meets the estimated building area and has more
extensive area for future expansion for additional services and
development

80 4 The site meets the estimated building area and has enough area to
allow future expansion for the additional services and development

60 3 The site meets the estimated building area but limited expansions
due to are size constraint

40 2 The site meets the estimated building area but has no potential for
future expansion

20 1 The site does not meet the estimated building area

5. DRAINAGE SYSTEM AVAILABILITY

PERCENTAG RANK CRITERIA EVALUATION


E

100 5 There is a functional drainage system in the site and would not
accumulate waters from adjacent areas

80 4 There is a functional drainage system in the site but accumulates a


little water from adjacent areas but can be mitigated

60 3 There is a poor drainage system in the site and accumulates water


in a portion from the adjacent areas and cannot be mitigated
40 2 There is a poor drainage system in the site and accumulate the
from the neighborhood

20 1 The site is mostly low and serves as a catchment of the drains in


the neighborhood.
Hygienic Design of Food Factories (J. Holah, H. L. M. Lelieveld) page 90-100

6. CLIMATE CRITERIA

PERCENTAG RANK CRITERIA EVALUATION


E

100 4 The rainfall is almost evenly


distributed during the whole year

80 3 There is a short dry season, usually from February to April

50 2 There is no dry period at all throughout the year, with a pronounced


wet season from November to February

25 1 There is a distinct dry and a wet season; wet from June to


November and dry, the rest of the year

7. ENVIRONMENTAL CONTAMINANT
This criteria measures the suitability of the adjacent environment of the site ensuring that it does
not create a detrimental effect on the future establishment.

PERCENTAG RANK CRITERIA EVALUATION


E

100 5 The site is located farthest from an area that has environmental
contaminants.

80 4 The site is located far from an area that has environmental


contaminants but it has no direct impact to the establishment

60 3 The site is located near but not directly adjacent from an area that
has environmental contaminants and can be mitigated that has
minimal impact to the establishment

40 2 The site is located directly adjacent from an area that has


environmental contaminants and has direct effect to the
establishment

20 1 The site is located on an area that has environmental contaminants


RATINGS FOR LEGAL AND ADMINISTRATIVE FACTORS
8. EASE OF OWNERSHIP

PERCENTAG RANK CRITERIA EVALUATION


E

100 5 The site is undivided presenting minimal challenges in ownership


structure

75 4 The site is owned by few individuals, contributing to the moderate


ease of ownership

50 3 The site is owned by a moderate number of individuals, requiring


careful coordination

25 2 The site is owned by extensive number of individuals, posing a


significant challenge to ownership

9. PROPER LAND USE AND ZONING CRITERIA

PERCENTAG RANK CRITERIA EVALUATION


E

100 5 The site is classified as appropriate for a Division J-1 building


occupancy in the National Building Code

80 4 The site is classified as appropriate for a Division J-1 building


occupancy but has potential for future amendments

60 3 The site is classified as appropriate for large building constructions

40 2 The site is classified as appropriate for large building construction


with constraints on the building use and type

20 1 The site is not appropriate for large building construction.


10. RELATIONSHIP WITH ADJACENT ENVIRONMENT

PERCENTAG RANK CRITERIA EVALUATION


E

100 5 The site conforms accurately to the adjacent and surrounding


areas given that they are of the same building type

80 4 The site conforms relatively to the adjacent and surrounding areas

60 3 The site somewhat conforms to the adjacent and surrounding


areas with minor mitigation to be done
40 2 The site has the potential to conform to the adjacent buildings and
area with major mitigation to be done

20 1 The site does not conform to the adjacent and surrounding areas
SOCIO- ECONOMIC FACTORS
11. ACCESSIBILITY TO NATIONAL ROADS

PERCENTAGE RANK CRITERIA EVALUATION

100 5 The site is in directly accessible or walkable to the national road

80 4 The site is within 2 kilometers from the national road

60 3 The site is within 4 kilometers from the national road

40 2 The site is within 6 kilometers from the national road

20 1 The site is more than 6 kilometers from the national road

12. AVAILABILITY OF CONSTRUCTION MATERIALS

PERCENTAG RANK CRITERIA EVALUATION


E

100 5 Excellent. The site is near a hardware store and material


transportation is easy with no road obstruction

80 4 Good. The site is within a travel distance from a hardware store


and the material transportation is easy with no road obstruction

60 3 Fair. The site is within a far distance from a hardware store and the
material transportation can be mildly challenging

40 2 Poor. The site is very distant from a hardware store and the
transportation can be very difficult.

20 1 Very Poor. The site is very distant from a hardware store and is
inaccessible
13. WATER SUPPLY CRITERIA

PERCENTAG RANK CRITERIA EVALUATION


E

100 5 Water supply and system is available and sufficient in the area
and has no issues of disruption and the like
80 4 Water supply and system is available and sufficient in the area,
however there are occurrences of rare water supply and system
disruption

60 3 Water supply and system is available in the area, however there


are common occurrences water supply and system disruption

40 2 Water supply and system are not yet available in the area,
however a there is a potential water source nearby

20 1 Water supply and system is not available in the area including the
areas nearby

a. ELECTRICITY AND CONNECTIVITY CRITERIA

PERCENTAG RANK CRITERIA EVALUATION


E

100 5 - Electricity supply and system is available and sufficient in the


area and has no issues of electrical outage
-Mobile and Internet connection is available and sufficient in the
area with no issues regarding signal disruption.

80 4 -Electricity supply is available and sufficient in the area, however


there are occurrences of rare electrical outage
-Mobile and internet connection is available in the area, however
there are rare of signal interruption

60 3 -Electricity supply is available in the area, however there are


common occurrences of electrical outage
-Mobile and internet connection is available in the area, however
there are is a weak reception

40 2 -Electricity supply is not available in the area however there is a


potential source nearby
-Mobile and internet connection has no reception however there is
a potential source nearby

20 1 -Electricity supply is not available in the area and no potential


source nearby
-Mobile and internet connection is not available in the area and no
potential source nearby