DESIGN CALCULATION REPORT FOR MMS STRUCTURE

DESIGN CALCULATION REPORT FOR MMS STRUCTURE


DOUBLE CARPORT

CLIENT: SIRAJ POWER

PROJECT NAME: RUW

LOCATION: RIFFA, KINGDOM OF BAHRAIN

DESIGNED BY: NEW GATEWAY OF DUBAI

DATE: 15/02/2024

APPROVED BY
REV DATE REASON FOR ISSUE ORIG CHKD
DEVELOPER CONSULTANT
0 15/02/2024 ISSUED FOR REVIEW NGD SP
DESIGN CALCULATION REPORT FOR MMS STRUCTURE

1 SUMMARY
1.1 Project Description

* Introduction: This design report document forms the part of detailed engineering scope of 3.7MW RUW ground mounted carpark structure.
The ground mount fixed tilt carport structure will be used to support the solar modules. The design of purlin, rafter, bracing
& column member is used to support the solar modules. Hot form metal sheets are used to fabricate column & taper
cantilever beam members and cold form channel section is used for purlin members.

* Scope: The scope of this calculation report is to present the STAAD models, geometrical modeling, wind load calculation, load
combinations, design parameters, assumptions, strength and stability checks performed for solar module supporting for
ground mounted fixed tilt carport solar structure.

* Project Name: RUW


* Solar Module Dimension: 575W G= 274.68 N( 28 KG )
2278 mm * 1134 mm * 35 mm ; Potrait
* Installtion Degree: 3⁰
* Installation Place: Bahrain
* Wind Speed: 40 m/s
* Risk Category III
Risk Category of Building and Other Structures for the Flood, Wind,Snow, Earthquake and Ice Loads.

1.2 Solar Carport Structure Summary


※ Solar Carport Structure is single/double pole cantilever steel structure, with assembly of purlin, beams and other connection parts which are connected by
DIN Standard fasteners.

※ Design Standards
* ASCE/SEI 7–10, ASCE/SEI 7–16 “Minimum Design Loads for Buildings and Other Structures”
* BS 5950 - Part 1 "Structural use of Steel Work in Building-Code of Practice for Rolled and welded sections.
* ASTM A 283/A 283M-2018 “Standard Specif i cation forLow and Intermediate Tensile Strength Carbon Steel Plates1”
* ASTM-B221M-2013
“Standard Specification forAluminum and Aluminum-Alloy Extruded Bars, Rods, Wire,Profiles, and Tubes (Metric) ”
* ASTM A153/A153M-16a “Standard Specification for Zinc Coating (Hot-Dip) on Iron and Steel Hardware”
ASTM B580-79(2014) “Standard Specification for Anodic Oxide Coatings on Aluminum”
* GB 50429-2007 “Code for design of aluminium structures”
* GB 50429-2007 “Code for design of aluminium structures”

※ Materials for Main Parts


Purlin: S275 Structural Steel
Column and Rafter: S355 Structural Steel
Fastener: GI Bolts
※ Aided Design Software
STAAD.Pro V8i
DESIGN CALCULATION REPORT FOR MMS STRUCTURE

* Snow Load: 0 N/cm/m2


2 Characteristics of Solar Mount

2.1 Inputs from client

* RUW-PHYSICAL LAYOUT R8

2.2 Three Dimensional Calculation of Solar Mount

X Direction Length = 11.5 m


X Direction Projected Length = 11.4 m
Z Direction Width = 38.3 m
Y Direction Height (the Peak of solar module) = 3.3 m

5 Rows 33 Column = 165 PCS

2.3 Material properties:

Description Material Properties

Column S275 I Section-500*150*10mm

Cantilever Taper Beam-


Rafter S275 Beam start-500*150*10mm
Beam end-200*150*10mm
C Purlin
Purlin S355
200*65*2mm
DESIGN CALCULATION REPORT FOR MMS STRUCTURE

3 Load Calculation

3.1 Dead Load "DL"

3.1.1 Self Weight of structural parts


A. C Purlin200*65*2mm
B. Cantilever Taper Beam- Beam start-500*150*10mm-Beam end-200*150*10mm
C. Column -450*150*8mm
Steel framing self-weight computed in STAADPro

3.1.2 Solar Panel Weight 29.0 kg


Panel Dimension 2278 * 1134 * 35 mm
Line Load on C Purlin 29.0 * g / 1000 / 2 / 1.134 = 0.125 kN/m

3.2 Live Load "LL"

Minimum live load 25.0 kg/m2 (0.25 kN/m2 )


Minimum live load 0.25 * Area of Table / 10 / Length of Purlin
Line Load on C Purlin 0.25 * 440.3 / 10 / 38.3 = 0.28 kN/m

3.3 Wind Load "W"

Basic Wind Velocity Vb = 40 m/s


Wind Directionality Factor Kd = 0.85 Table 26.6-1
Topographic Factor Kzt = 1.00 Fig 26.8-2
Exposure Categories = C Fig 26.7-2
Surface Roughness Categories = C Fig 26.7-3
Velocity Pressure Coefficient Kz = 0.85 Table 26.10-1
Solar Mount Height H = 3.26 m
Wind Pressure qh = 0.613 * kz * kzt * kd * V²
qh = 0.70863 kN/m²
= 0.77 kN/m² (Design Wind pressure)
DESIGN CALCULATION REPORT FOR MMS STRUCTURE

3.3.1 Design Wind Load


Gust effect Factor G = 0.85 Fig 27.3.5
Body Shape Coefficient CN = Ref. Fig 27.4.5
For values of θ between 7.5° and 45°, linear interpolation is permitted. For values of θ less than 7.5°, the code recommends to use load coefficients for
0°.However, for double shade structure, consider interpolating the values for the tilt 3 degree angle.

3.3.1.1 Windloads in X Direction


Solar panel tilt angle 3 degrees
ϒ = 0⁰ CNW = 1.2 CNL = 0.3
ϒ = 180 ⁰ CNW = 1.2 CNL = 0.3

At ϒ = 0
Design Wind Pressure (CNW) P1 = qh * G * CNW
P1 = 0.77 * 0.85 * 1.2 = 0.7854 kN/m²
Design Wind Pressure (CNL) P2 = qh * G * CNL
P2 = 0.77 * 0.85 * 0.3 = 0.19635 kN/m²

At ϒ = 180 ⁰
Design Wind Pressure (CNW) P3 = qh * G * CNW
P3 = 0.77 * 0.85 * 1.2 = 0.7854 kN/m²
Design Wind Pressure (CNL) P4 = qh * G * CNL
P4 = 0.77 * 0.85 * 0.3 = 0.196 kN/m²

UDL of Wind Loads:

At ϒ = 0⁰ (Wind ward face)


Wind Load CNW = P1 * Area of Table / 10 / Length of Purlin
UPWARD CNW = 0.785 * 440.3 / 10 / 38.3
CNW = 0.90 kN/m

Wind Load CNL = P2 * Area of Table / 10 / Length of Purlin


UPWARD CNL = 0.196 * 440.3 / 10 / 38.3
CNL = 0.23 kN/m

Line distribution of Wind Loads:


At ϒ = 180 ⁰ (Leeward face)
Wind Load C NW = P3 * Area of Table / 10 / Length of Purlin
DOWNWARD CNW = 0.7854 * 440.3 / 10 / 38.3
CNW = 0.90 kN/m

Wind Load CNL = P4 * Area of Table / 10 / Length of Purlin


DOWNWARD CNL = 0.196 * 440.3 / 10 / 38.3
CNL = 0.23 kN/m
DESIGN CALCULATION REPORT FOR MMS STRUCTURE

3.3.1.1 Windloads in Z Direction

Wind loads are computed in STAADPro Software

4 Basic Load Cases & Combinations

4.1 Basic Load Cases

Following table present the basic load cases applied in STAAD model of ground mounted fixed tilt Solar carport structure for wind speed 40 m/s and tilt
angle 30 :

Load Case Description Factor

1 Dead Load : DL 1

2 Live Load : LL 1

3 Wind Load : Up 1

4 Wind Load : Down 1

5 Wind Load : +Z 1

6 Wind Load : -Z 1

4.2 Load Combinations

Following table present theload cobinations applied in STAAD model of ground mounted fixed tilt Solar carport structure for wind speed 40 m/s and tilt
angle 30 for member deflection, serviceabilty check:

Combination Combination L/C Name Primary Primary L/C Name Factor

7 1.2DL+LL+WIND DN 1 Dead Load : DL 1.2

2 Live Load : LL 1

4 Wind Load : Down 1

8 0.9DL+WIND UP 1 Dead Load : DL 0.9

3 Wind Load : Up 1

9 0.9DL+WIND DN 1 Dead Load : DL 0.9

4 Wind Load : Down 1

10 DL+LL+WIND UP 1 Dead Load : DL 1

2 Live Load : LL 1

3 Wind Load : Up 1

11 DL+LL+WIND DN 1 Dead Load : DL 1

2 Live Load : LL 1

4 Wind Load : Down 1

14 1.4DL 1 Dead Load : DL 1.2

15 1.4DL+1.6LL 1 Dead Load : DL 1.2

2 Live Load : LL 1.6

16 1.2DL+LL+0.5WIND UP 1 Dead Load : DL 1.2

2 Live Load : LL 1

3 Wind Load : Up 0.5

17 1.2DL+LL+0.5WIND DN 1 Dead Load : DL 1.2

2 Live Load : LL 1

4 Wind Load : Down 0.5

18 1.2DL+LL+WIND UP 1 Dead Load : DL 1.2

2 Live Load : LL 1

3 Wind Load : Up 1
DESIGN CALCULATION REPORT FOR MMS STRUCTURE

5 Deflection limits

Deflection Structural member Permissible deflection limit

Lateral Column L/240

Vertical (Simply supported) Rafter & Purlin L/180

Vertical (Cantilever) Rafter & Purlin L/90

6 STAAD Model

Three Dimensional Views


STAAD Model– Wind Speed 40m/s, Tilt Angle 3 degree

For Member number, node number, section properties STAAD plot please refer Annexure 1.0.
DESIGN CALCULATION REPORT FOR MMS STRUCTURE

7 Summary of Results

7.1 Member Unity Check

S.N. Member Section Size Governing L/C Maximum UC

1 Column I Section-500*150*10mm 7 0.694

Cantilever Taper Beam-


2 Rafter Beam start-500*150*10mm 7 0.605
Beam end-200*150*10mm

3 Purlin C Purlin200*65*2mm 7 N/A

All members are safe and member UC are within the acceptable limits. Detail member UC check and STAAD plots refer Annexure 1.0.
Purlin design to be checked by deflection criteria.

7.2 Deflection Check

Summary of member deflection:

Actual deflection Allowable deflection


S.N. Member Governing L/C Remark
(mm) (mm)
1 Column 1.4 11.55 11 Safe

2 Rafter 41.9 58.11 11 Safe

3 Purlin 23.75 41.67 15 Safe

Deflection check for Column, Rafter and Purlin are performed manually for criteria as specified within document and are within
acceptable limits. Refer maximum deflection plot attached within Annexure 1.0.

7 Conclusion

Member stresses for column, rafter and purlin are as per found acceptable for operating design condition. Maximum deflection of the
column, rafter and purlin members are within the permissible limits.

HENCE, THE SOLAR CARPORT STRUCTURE DESIGN IS SAFE.


DESIGN CALCULATION REPORT FOR MMS STRUCTURE

ANNEXURE 1.0
Job No Sheet No Rev
1 1 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Job Information
Engineer Checked Approved

Name: New Gateway of Dubai SD SD


Date: 2/9/2024 2/9/2024 2/9/2024

Project ID
Project Name

Structure Type SPACE FRAME

Number of Nodes 75 Highest Node 105


Number of Elements 110 Highest Beam 334

Number of Basic Load Cases 6


Number of Combination Load Cases 10

Included in this printout are data for:


All The Whole Structure

Included in this printout are results for load cases:


Type L/C Name

Primary 1 DL
Primary 2 LL
Primary 3 WIND UP
Primary 4 WIND DN
Primary 5 WIND +Z
Primary 6 WIND -Z
Combination 7 1.2DL+LL+WLDN
Combination 8 0.9DL+WLUP
Combination 9 0.9DL+WLDN
Combination 10 DL+LL+WL UP
Combination 11 DL+LL+WL DN
Combination 14 1.4D
Combination 15 1.2D+1.6L
Combination 16 1.2D+1.6L+0.5WLUP
Combination 17 1.2D+1.6L+0.5WDN
Combination 18 1.2DL+LL+WLUP

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 1 of 159
Job No Sheet No Rev
1 2 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

3D Rendered View

7500.000mm

7500.000mm

7500.000mm

7500.000mm

3D2

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 2 of 159
Job No Sheet No Rev
1 3 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Nodes
Node X Y Z
(mm) (mm) (mm)
1 0 0 -8.4E+3
2 0 1.9E+3 -8.4E+3
3 0 2.77E+3 -8.4E+3
16 -576.209 2.74E+3 -8.4E+3
17 -1.71E+3 2.68E+3 -8.4E+3
18 -2.87E+3 2.62E+3 -8.4E+3
19 -4E+3 2.56E+3 -8.4E+3
20 -5.24E+3 2.5E+3 -8.4E+3
21 576.209 2.8E+3 -8.4E+3
22 1.71E+3 2.86E+3 -8.4E+3
23 2.87E+3 2.92E+3 -8.4E+3
24 4E+3 2.98E+3 -8.4E+3
25 5.2E+3 3.04E+3 -8.4E+3
26 0 0 -900.000
27 0 1.9E+3 -900.000
28 0 2.77E+3 -900.000
31 -576.209 2.74E+3 -900.000
32 -1.71E+3 2.68E+3 -900.000
33 -2.87E+3 2.62E+3 -900.000
34 -4E+3 2.56E+3 -900.000
35 -5.24E+3 2.5E+3 -900.000
36 576.209 2.8E+3 -900.000
37 1.71E+3 2.86E+3 -900.000
38 2.87E+3 2.92E+3 -900.000
39 4E+3 2.98E+3 -900.000
40 5.2E+3 3.04E+3 -900.000
41 0 0 6.6E+3
42 0 1.9E+3 6.6E+3
43 0 2.77E+3 6.6E+3
46 -576.209 2.74E+3 6.6E+3
47 -1.71E+3 2.68E+3 6.6E+3
48 -2.87E+3 2.62E+3 6.6E+3
49 -4E+3 2.56E+3 6.6E+3
50 -5.24E+3 2.5E+3 6.6E+3
51 576.209 2.8E+3 6.6E+3
52 1.71E+3 2.86E+3 6.6E+3
53 2.87E+3 2.92E+3 6.6E+3
54 4E+3 2.98E+3 6.6E+3
55 5.2E+3 3.04E+3 6.6E+3
56 0 0 14.1E+3
57 0 1.9E+3 14.1E+3
58 0 2.77E+3 14.1E+3
61 -576.209 2.74E+3 14.1E+3
62 -1.71E+3 2.68E+3 14.1E+3
63 -2.87E+3 2.62E+3 14.1E+3
64 -4E+3 2.56E+3 14.1E+3
65 -5.24E+3 2.5E+3 14.1E+3
66 576.209 2.8E+3 14.1E+3
67 1.71E+3 2.86E+3 14.1E+3

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 3 of 159
Job No Sheet No Rev
1 4 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Nodes Cont...
Node X Y Z
(mm) (mm) (mm)
68 2.87E+3 2.92E+3 14.1E+3
69 4E+3 2.98E+3 14.1E+3
70 5.2E+3 3.04E+3 14.1E+3
71 0 0 21.6E+3
72 0 1.9E+3 21.6E+3
73 0 2.77E+3 21.6E+3
76 -576.209 2.74E+3 21.6E+3
77 -1.71E+3 2.68E+3 21.6E+3
78 -2.87E+3 2.62E+3 21.6E+3
79 -4E+3 2.56E+3 21.6E+3
80 -5.24E+3 2.5E+3 21.6E+3
81 576.209 2.8E+3 21.6E+3
82 1.71E+3 2.86E+3 21.6E+3
83 2.87E+3 2.92E+3 21.6E+3
84 4E+3 2.98E+3 21.6E+3
85 5.2E+3 3.04E+3 21.6E+3
96 4.58E+3 3.01E+3 -8.4E+3
97 -4.58E+3 2.53E+3 -8.4E+3
98 4.58E+3 3.01E+3 -900.000
99 -4.58E+3 2.53E+3 -900.000
100 4.58E+3 3.01E+3 6.6E+3
101 -4.58E+3 2.53E+3 6.6E+3
102 4.58E+3 3.01E+3 14.1E+3
103 -4.58E+3 2.53E+3 14.1E+3
104 4.58E+3 3.01E+3 21.6E+3
105 -4.58E+3 2.53E+3 21.6E+3

Beams
Beam Node A Node B Length Property 
(mm) (degrees)
1 1 2 1.9E+3 1 0
2 2 3 875.160 2 0
15 26 27 1.9E+3 1 0
16 27 28 875.160 2 0
29 41 42 1.9E+3 1 0
30 42 43 875.160 2 0
43 56 57 1.9E+3 1 0
44 57 58 875.160 2 0
57 71 72 1.9E+3 1 0
58 72 73 875.160 2 0
72 25 40 7.5E+3 15 0
73 24 39 7.5E+3 15 0
74 23 38 7.5E+3 15 0
75 22 37 7.5E+3 15 0
76 21 36 7.5E+3 15 0
77 16 31 7.5E+3 15 0
78 17 32 7.5E+3 15 0

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 4 of 159
Job No Sheet No Rev
1 5 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Beams Cont...
Beam Node A Node B Length Property 
(mm) (degrees)
79 18 33 7.5E+3 15 0
80 19 34 7.5E+3 15 0
81 20 35 7.5E+3 15 0
84 40 55 7.5E+3 15 0
85 39 54 7.5E+3 15 0
86 38 53 7.5E+3 15 0
87 37 52 7.5E+3 15 0
88 36 51 7.5E+3 15 0
89 31 46 7.5E+3 15 0
90 32 47 7.5E+3 15 0
91 33 48 7.5E+3 15 0
92 34 49 7.5E+3 15 0
93 35 50 7.5E+3 15 0
96 55 70 7.5E+3 15 0
97 54 69 7.5E+3 15 0
98 53 68 7.5E+3 15 0
99 52 67 7.5E+3 15 0
100 51 66 7.5E+3 15 0
101 46 61 7.5E+3 15 0
102 47 62 7.5E+3 15 0
103 48 63 7.5E+3 15 0
104 49 64 7.5E+3 15 0
105 50 65 7.5E+3 15 0
108 70 85 7.5E+3 15 0
109 69 84 7.5E+3 15 0
110 68 83 7.5E+3 15 0
111 67 82 7.5E+3 15 0
112 66 81 7.5E+3 15 0
113 61 76 7.5E+3 15 0
114 62 77 7.5E+3 15 0
115 63 78 7.5E+3 15 0
116 64 79 7.5E+3 15 0
117 65 80 7.5E+3 15 0
275 3 21 577.000 5 0
276 3 16 576.999 3 0
277 21 22 1.14E+3 4 0
278 22 23 1.16E+3 6 0
279 23 24 1.14E+3 7 0
280 24 96 578.493 8 0
281 96 25 623.445 9 0
282 16 17 1.14E+3 10 0
283 17 18 1.16E+3 11 0
284 18 19 1.14E+3 12 0
285 19 97 578.493 13 0
286 97 20 663.401 14 0
287 28 36 577.000 5 0
288 28 31 576.999 3 0
289 36 37 1.14E+3 4 0
290 37 38 1.16E+3 6 0

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 5 of 159
Job No Sheet No Rev
1 6 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Beams Cont...
Beam Node A Node B Length Property 
(mm) (degrees)
291 38 39 1.14E+3 7 0
292 39 98 578.493 8 0
293 98 40 623.445 9 0
294 31 32 1.14E+3 10 0
295 32 33 1.16E+3 11 0
296 33 34 1.14E+3 12 0
297 34 99 578.493 13 0
298 99 35 663.401 14 0
299 43 51 577.000 5 0
300 43 46 576.999 3 0
301 51 52 1.14E+3 4 0
302 52 53 1.16E+3 6 0
303 53 54 1.14E+3 7 0
304 54 100 578.493 8 0
305 100 55 623.445 9 0
306 46 47 1.14E+3 10 0
307 47 48 1.16E+3 11 0
308 48 49 1.14E+3 12 0
309 49 101 578.493 13 0
310 101 50 663.401 14 0
311 58 66 577.000 5 0
312 58 61 576.999 3 0
313 66 67 1.14E+3 4 0
314 67 68 1.16E+3 6 0
315 68 69 1.14E+3 7 0
316 69 102 578.493 8 0
317 102 70 623.445 9 0
318 61 62 1.14E+3 10 0
319 62 63 1.16E+3 11 0
320 63 64 1.14E+3 12 0
321 64 103 578.493 13 0
322 103 65 663.401 14 0
323 73 81 577.000 5 0
324 73 76 576.999 3 0
325 81 82 1.14E+3 4 0
326 82 83 1.16E+3 6 0
327 83 84 1.14E+3 7 0
328 84 104 578.493 8 0
329 104 85 623.445 9 0
330 76 77 1.14E+3 10 0
331 77 78 1.16E+3 11 0
332 78 79 1.14E+3 12 0
333 79 105 578.493 13 0
334 105 80 663.401 14 0

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 6 of 159
Job No Sheet No Rev
1 7 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Section Properties
Prop Section Area Iyy Izz J Material
(cm2) (cm4) (cm4) (cm4)
1 Taper 68.400 564.548 25.4E+3 18.192 STEEL_275_NMM2
2 Taper 120.400 567.321 321E+3 29.285 STEEL_275_NMM2
3 Taper 66.970 564.472 23.4E+3 17.887 STEEL_275_NMM2
4 Taper 62.722 564.245 17.9E+3 16.981 STEEL_275_NMM2
5 Taper 66.970 564.472 23.4E+3 17.887 STEEL_275_NMM2
6 Taper 57.037 563.942 11.8E+3 15.768 STEEL_275_NMM2
7 Taper 51.352 563.639 7.18E+3 14.555 STEEL_275_NMM2
8 Taper 47.101 563.412 4.45E+3 13.648 STEEL_275_NMM2
9 Taper 44.234 563.259 3.06E+3 13.037 STEEL_275_NMM2
10 Taper 62.722 564.245 17.9E+3 16.981 STEEL_275_NMM2
11 Taper 57.037 563.942 11.8E+3 15.768 STEEL_275_NMM2
12 Taper 51.352 563.639 7.18E+3 14.555 STEEL_275_NMM2
13 Taper 47.101 563.412 4.45E+3 13.648 STEEL_275_NMM2
14 Taper 44.234 563.259 3.06E+3 13.037 STEEL_275_NMM2
15 200CLAW65X20 6.861 33.866 408.259 0 STEEL_355_NMM2

Materials
Mat Name E  Density 
(kN/mm2) (kg/m3) (/°C)
1 CONCRETE 21.718 0.170 2.4E+3 10E -6
2 ALUMINUM 68.948 0.330 2.71E+3 23E -6
3 STEEL_50_KSI 199.948 0.300 7.83E+3 11.7E -6
4 STAINLESSSTEEL 197.930 0.300 7.83E+3 18E -6
5 STEEL_36_KSI 199.948 0.300 7.83E+3 11.7E -6
6 STEEL_275_NMM2 205.000 0.300 7.85E+3 12E -6
7 STEEL 205.000 0.300 7.83E+3 12E -6
8 STEEL_355_NMM2 205.000 0.300 7.85E+3 12E -6

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 7 of 159
Job No Sheet No Rev
1 8 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

R9
R7R8 R15
R6 R15
R5 R4 R15
R3 R15 R9
R10
R11 R2 R15 R7R8 R15
R12 R15 R6 R15
R13
R14 R15 R5R4 R15
R15 R3 R15 R9
R15
R1
R15
R10
R11 R2 R15 R7R8 R15
R12 R15 R6 R15
R13
R14 R15 R5R4 R15
R15 R3 R15 R9
R15
R1
R15
R10
R11 R2 R15 R7R8 R15
7500.000mm R12 R15 R6 R15
R13
R14 R15 R5R4 R15
R15 R3 R15 R9
R15
R1
R15
R10
R11 R2 R15 R7R8
7500.000mm R12 R15 R6
R13
R14 R15
R15 R3R5R4
R15 R10
R1
R15 R11 R2
7500.000mm R12
R13
R14
R1
7500.000mm

Y
X
Z
Load 1

PROPERTIES

STEEL_275_NMM2
STEEL_275_NMM2
STEEL_275_NMM2
STEEL_275_NMM2 STEEL_355_NMM2
STEEL_275_NMM2
STEEL_275_NMM2 STEEL_355_NMM2
STEEL_355_NMM2
STEEL_275_NMM2
STEEL_275_NMM2 STEEL_355_NMM2 STEEL_275_NMM2
STEEL_275_NMM2
STEEL_275_NMM2
STEEL_275_NMM2 STEEL_355_NMM2 STEEL_275_NMM2
STEEL_275_NMM2 STEEL_355_NMM2
STEEL_275_NMM2
STEEL_275_NMM2 STEEL_355_NMM2
STEEL_355_NMM2 STEEL_275_NMM2 STEEL_355_NMM2
STEEL_275_NMM2
STEEL_355_NMM2 STEEL_275_NMM2
STEEL_275_NMM2 STEEL_355_NMM2
STEEL_355_NMM2 STEEL_275_NMM2
STEEL_275_NMM2
STEEL_355_NMM2
STEEL_275_NMM2 STEEL_275_NMM2
STEEL_275_NMM2
STEEL_275_NMM2 STEEL_355_NMM2 STEEL_275_NMM2
STEEL_355_NMM2STEEL_275_NMM2 STEEL_355_NMM2 STEEL_275_NMM2 STEEL_355_NMM2
STEEL_275_NMM2
STEEL_275_NMM2 STEEL_355_NMM2 STEEL_275_NMM2
STEEL_275_NMM2 STEEL_355_NMM2
STEEL_355_NMM2
STEEL_355_NMM2
STEEL_355_NMM2 STEEL_275_NMM2
STEEL_275_NMM2 STEEL_355_NMM2 STEEL_275_NMM2
STEEL_275_NMM2
STEEL_275_NMM2
STEEL_355_NMM2 STEEL_275_NMM2
STEEL_275_NMM2 STEEL_355_NMM2 STEEL_275_NMM2
STEEL_275_NMM2 STEEL_355_NMM2
7500.000mm STEEL_275_NMM2
STEEL_275_NMM2 STEEL_355_NMM2
STEEL_355_NMM2 STEEL_275_NMM2 STEEL_355_NMM2
STEEL_275_NMM2 STEEL_355_NMM2 STEEL_275_NMM2
STEEL_275_NMM2 STEEL_355_NMM2
STEEL_355_NMM2 STEEL_275_NMM2
STEEL_355_NMM2
STEEL_275_NMM2 STEEL_275_NMM2
STEEL_275_NMM2
STEEL_355_NMM2 STEEL_275_NMM2
STEEL_275_NMM2
STEEL_355_NMM2
7500.000mm STEEL_275_NMM2
STEEL_275_NMM2 STEEL_355_NMM2 STEEL_275_NMM2
STEEL_275_NMM2
STEEL_275_NMM2 STEEL_355_NMM2 STEEL_275_NMM2
STEEL_275_NMM2
STEEL_355_NMM2
STEEL_355_NMM2 STEEL_275_NMM2
STEEL_275_NMM2
STEEL_275_NMM2
STEEL_355_NMM2 STEEL_275_NMM2
STEEL_275_NMM2
7500.000mm STEEL_275_NMM2
STEEL_275_NMM2
STEEL_275_NMM2
STEEL_275_NMM2
7500.000mm

Y
X
Z
Load 1

MATERIALS

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 8 of 159
Job No Sheet No Rev
1 9 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Primary Load Cases


Number Name Type

1 DL Dead
2 LL Live
3 WIND UP Wind
4 WIND DN Wind
5 WIND +Z Wind
6 WIND -Z Wind

Combination Load Cases


Comb. Combination L/C Name Primary Primary L/C Name Factor

7 1.2DL+LL+WLDN 1 DL 1.20
2 LL 1.00
4 WIND DN 1.00
8 0.9DL+WLUP 1 DL 0.90
3 WIND UP 1.00
9 0.9DL+WLDN 1 DL 0.90
4 WIND DN 1.00
10 DL+LL+WL UP 1 DL 1.00
2 LL 1.00
3 WIND UP 1.00
11 DL+LL+WL DN 1 DL 1.00
2 LL 1.00
4 WIND DN 1.00
14 1.4D 1 DL 1.40
15 1.2D+1.6L 1 DL 1.20
2 LL 1.60
16 1.2D+1.6L+0.5WLUP 1 DL 1.20
2 LL 1.60
3 WIND UP 0.50
17 1.2D+1.6L+0.5WDN 1 DL 1.20
2 LL 1.00
4 WIND DN 0.50
18 1.2DL+LL+WLUP 1 DL 1.20
2 LL 1.00
3 WIND UP 1.00

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 9 of 159
Job No Sheet No Rev
1 10 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

-0.125 kN/m
-0.125
-0.125 kN/m
kN/m
-0.125
-0.125 kN/m
kN/m
-0.125 kN/m -0.125 kN/m
-0.125 kN/m -0.125
-0.125 kN/m
kN/m
-0.125
-0.125 kN/m
kN/m -0.125 kN/m
-0.125 kN/m -0.125
-0.125 kN/m
kN/m -0.125 kN/m
-0.125 kN/m -0.125
-0.125 kN/m
kN/m
-0.125
-0.125 kN/m
kN/m -0.125 kN/m
-0.125 kN/m -0.125
-0.125 kN/m
kN/m -0.125 kN/m
-0.125 kN/m -0.125
-0.125 kN/m
kN/m
-0.125 kN/m
-0.125 kN/m -0.125 kN/m
-0.125 kN/m -0.125
-0.125 kN/m
kN/m
-0.125
-0.125 kN/m
kN/m
-0.125 kN/m
-0.125 kN/m
7500.000mm

7500.000mm

7500.000mm

7500.000mm

Y
X
Z
Load 1

DL

-0.280 kN/m
-0.280
-0.280 kN/m
kN/m
-0.280
-0.280 kN/m
kN/m
-0.280 kN/m -0.280 kN/m
-0.280 kN/m -0.280
-0.280 kN/m
kN/m
-0.280 kN/m
-0.280 kN/m -0.280 kN/m
-0.280 kN/m -0.280
-0.280 kN/m
kN/m -0.280 kN/m
-0.280 kN/m -0.280
-0.280 kN/m
kN/m
-0.280 kN/m
-0.280 kN/m -0.280 kN/m
-0.280 kN/m -0.280
-0.280 kN/m
kN/m -0.280 kN/m
-0.280 kN/m -0.280
-0.280 kN/m
kN/m
-0.280
-0.280 kN/m
kN/m -0.280 kN/m
-0.280 kN/m -0.280
-0.280 kN/m
kN/m
-0.280
-0.280 kN/m
kN/m
-0.280 kN/m
-0.280 kN/m
7500.000mm

7500.000mm

7500.000mm

7500.000mm

Y
X
Z
Load 2

LL

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 10 of 159
Job No Sheet No Rev
1 11 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

0.200kN/m
0.200 kN/m
0.200
0.200 kN/m
kN/m 0.230 kN/m
0.200 kN/m 0.230
0.230 kN/mkN/m
0.200
0.200 kN/m
kN/m
0.230 kN/m 0.200kN/m
kN/m
0.200 kN/m
0.230 kN/m 0.200
0.200 kN/m
0.200 kN/m
0.300 kN/m 0.200 kN/m 0.230 kN/m
0.200
0.200 kN/m
kN/m 0.200 kN/m 0.230
0.230 kN/mkN/m
0.200kN/m
0.200 kN/m
0.230 kN/m 0.200kN/m
kN/m
0.200 kN/m
0.230 kN/m 0.200
0.200 kN/m
0.200 kN/m
0.300 kN/m 0.200 kN/m 0.230 kN/m
0.200kN/m
0.200 kN/m 0.200 kN/m 0.230
0.230 kN/m
kN/m
0.900
0.300 kN/m
kN/m 0.200kN/m
0.200 kN/m
0.230 kN/m 0.200kN/m
kN/m
0.900 kN/m 0.200 kN/m
0.230 kN/m 0.200
0.200 kN/m
0.900 kN/m
0.900 kN/m 0.200 kN/m
0.300 kN/m 0.200 kN/m0.230 kN/m
0.900 kN/m 0.200 kN/m
0.200 kN/m 0.200 kN/m 0.230
0.230 kN/m
kN/m
0.900
0.300 kN/m
kN/m 0.200
0.200 kN/m
kN/m
0.230 kN/m 0.200kN/m
kN/m
0.900 kN/m 0.200 kN/m
0.230 kN/m 0.200
0.200 kN/m
0.900
0.900 kN/mkN/m 0.200 kN/m
0.300 kN/m 0.200 kN/m
0.900 kN/m 0.200
0.200 kN/m
kN/m 0.200 kN/m
0.900
0.300 kN/m
kN/m 0.200kN/m
0.200 kN/m
0.900
0.900 kN/m
kN/m 0.200 kN/m
0.900 kN/m 0.200
0.200 kN/m
kN/m0.300 kN/m
0.900 kN/m 0.900
0.300 kN/m
kN/m 0.200 kN/m
0.900
0.900 kN/m
kN/m
0.900 kN/m
0.900 kN/m 0.300 kN/m

Y
X
Z
Load 3

WIND UP

-0.900 kN/m
-0.900
-0.900 kN/m
kN/m
-0.900 kN/m
-0.900 kN/m -0.900 kN/m
-0.900
-0.900 kN/m
kN/m
0.200 kN/m -0.900
-0.900 kN/m
kN/m
0.200 kN/m -0.900 kN/m
0.200
0.200 kN/m
kN/m -0.900
-0.900 kN/mkN/m
-0.230
0.200
-0.230 kN/m
kN/mkN/m -0.900 kN/m
-0.230 0.200
0.200
kN/m kN/m
kN/m 0.200kN/m
kN/m -0.900 kN/m -0.900 kN/m
0.200
-0.230 kN/mkN/m 0.200
0.200 kN/m
0.200
-0.230 kN/m kN/m
0.300 kN/m 0.200 kN/m -0.900
-0.900 kN/m
kN/m
0.200
0.200 kN/m
kN/m -0.230
0.200
-0.230 kN/m
kN/mkN/m -0.900 kN/m
-0.230 0.200
0.200
kN/m kN/m
kN/m 0.200 kN/m -0.900 kN/m
0.200
-0.230 kN/mkN/m 0.200
0.200 kN/mkN/m
0.200
-0.230
0.200 kN/m
kN/mkN/m
0.300 kN/m 0.200
-0.230 kN/m kN/m
0.300 kN/m0.200 kN/m 0.200
-0.230
0.200
-0.230 kN/m
0.200
kN/m
kN/m
kN/m
kN/m 0.200kN/m
0.200 kN/m
0.200
-0.230 kN/mkN/m 0.200 kN/m
0.200
-0.230
0.200 kN/m
kN/mkN/m
0.300 kN/m 0.200
-0.230 kN/m kN/m
0.300 kN/m 0.200 kN/m 0.200
-0.230
0.200kN/mkN/m
kN/m
0.200
-0.230
0.200 kN/m
kN/mkN/m 0.200kN/m
0.200 kN/m
-0.230
0.200 kN/m
kN/m 0.200 kN/m
-0.230
0.200 kN/m0.300 kN/m
kN/m 0.200 kN/m
0.300 kN/m0.200 kN/m 0.200
0.200
0.200 kN/m
kN/m
kN/m
0.200
0.200 kN/mkN/m
0.200 kN/m0.300 kN/m
0.300 kN/m0.200 kN/m

0.300 kN/m

Y
X
Z
Load 4

WIND DOWN

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 11 of 159
Job No Sheet No Rev
1 12 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Node Displacement Summary


Node L/C X Y Z Resultant rX rY rZ
(mm) (mm) (mm) (mm) (rad) (rad) (rad)
Max X 40 7:1.2DL+LL+WLDN 7.437 -48.229 -4.557 49.012 0.008 0.003 -0.013
Min X 28 15:1.2D+1.6L -0.020 -0.097 0 0.099 0 0 0.000
Max Y 35 3:WIND UP 3.139 36.367 66.748 76.077 0.008 0.011 -0.009
Min Y 40 7:1.2DL+LL+WLDN 7.437 -48.229 -4.557 49.012 0.008 0.003 -0.013
Max Z 20 3:WIND UP 1.570 18.184 66.748 69.198 0.008 0.011 -0.005
Min Z 20 6:WIND -Z 0 0 -50.828 50.828 -0.009 -0.008 0
Max rX 24 5:WIND +Z 0 0 10.487 10.487 0.009 0.001 0
Min rX 24 6:WIND -Z 0 0 -10.487 10.487 -0.009 -0.001 0
Max rY 20 3:WIND UP 1.570 18.184 66.748 69.198 0.008 0.011 -0.005
Min rY 20 6:WIND -Z 0 0 -50.828 50.828 -0.009 -0.008 0
Max rZ 35 15:1.2D+1.6L 0.828 -16.775 0 16.795 0 0 0.005
Min rZ 40 7:1.2DL+LL+WLDN 7.437 -48.229 -4.557 49.012 0.008 0.003 -0.013
Max Rst 35 3:WIND UP 3.139 36.367 66.748 76.077 0.008 0.011 -0.009

Y
X
Z
Load 3 : Displacement
Whole Structure Displacements 0.7mm:1mm 3

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 12 of 159
Job No Sheet No Rev
1 13 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Reactions
Horizontal Vertical Horizontal Moment
Node L/C FX FY FZ MX MY MZ
(kN) (kN) (kN) (kN-m) (kN-m) (kN-m)
1 1:DL -0.000 12.885 0 0 0 -0.097
2:LL 0.000 10.500 0 0 0 -0.042
3:WIND UP -0.000 -21.188 -2.924 -6.950 -0.042 36.215
4:WIND DN 0.000 21.188 -2.924 -6.950 -0.042 36.046
5:WIND +Z 0 0 -3.376 -8.023 -0.025 0
6:WIND -Z 0 0 3.376 8.023 0.025 0
7:1.2DL+LL+WLDN -0.000 47.149 -2.924 -6.950 -0.042 35.887
8:0.9DL+WLUP -0.000 -9.591 -2.924 -6.950 -0.042 36.128
9:0.9DL+WLDN -0.000 32.784 -2.924 -6.950 -0.042 35.958
10:DL+LL+WL UP -0.000 2.197 -2.924 -6.950 -0.042 36.076
11:DL+LL+WL DN -0.000 44.572 -2.924 -6.950 -0.042 35.906
14:1.4D -0.000 18.039 0 0 0 -0.136
15:1.2D+1.6L -0.000 32.262 0 0 0 -0.184
16:1.2D+1.6L+0.5WLUP
-0.000 21.668 -1.462 -3.475 -0.021 17.924
17:1.2D+1.6L+0.5WDN
-0.000 36.556 -1.462 -3.475 -0.021 17.864
18:1.2DL+LL+WLUP-0.000 4.774 -2.924 -6.950 -0.042 36.056
26 1:DL -0.000 19.493 0 0 0 -0.124
2:LL 0.000 21.000 0 0 0 -0.084
3:WIND UP -0.000 -42.375 -2.924 -6.950 -0.042 72.431
4:WIND DN -0.000 42.375 -2.924 -6.950 -0.042 72.092
5:WIND +Z 0 0 -3.376 -8.023 -0.025 0
6:WIND -Z 0 0 3.376 8.023 0.025 0
7:1.2DL+LL+WLDN -0.000 86.766 -2.924 -6.950 -0.042 71.859
8:0.9DL+WLUP -0.000 -24.832 -2.924 -6.950 -0.042 72.319
9:0.9DL+WLDN -0.000 59.918 -2.924 -6.950 -0.042 71.980
10:DL+LL+WL UP -0.000 -1.882 -2.924 -6.950 -0.042 72.223
11:DL+LL+WL DN -0.000 82.868 -2.924 -6.950 -0.042 71.884
14:1.4D -0.000 27.290 0 0 0 -0.173
15:1.2D+1.6L -0.000 56.991 0 0 0 -0.283
16:1.2D+1.6L+0.5WLUP
-0.000 35.804 -1.462 -3.475 -0.021 35.932
17:1.2D+1.6L+0.5WDN
-0.000 65.579 -1.462 -3.475 -0.021 35.813
18:1.2DL+LL+WLUP-0.000 2.016 -2.924 -6.950 -0.042 72.198
41 1:DL -0.000 19.493 0 0 0 -0.124
2:LL -0.000 21.000 0 0 0 -0.084
3:WIND UP -0.000 -42.375 -2.924 -6.950 -0.042 72.431
4:WIND DN -0.000 42.375 -2.924 -6.950 -0.042 72.092
5:WIND +Z 0 0 -3.376 -8.023 -0.025 0
6:WIND -Z 0 0 3.376 8.023 0.025 0
7:1.2DL+LL+WLDN -0.000 86.766 -2.924 -6.950 -0.042 71.859
8:0.9DL+WLUP -0.000 -24.832 -2.924 -6.950 -0.042 72.319
9:0.9DL+WLDN -0.000 59.918 -2.924 -6.950 -0.042 71.980
10:DL+LL+WL UP -0.000 -1.882 -2.924 -6.950 -0.042 72.223
11:DL+LL+WL DN -0.000 82.868 -2.924 -6.950 -0.042 71.884
14:1.4D -0.000 27.290 0 0 0 -0.173
15:1.2D+1.6L -0.000 56.991 0 0 0 -0.283
16:1.2D+1.6L+0.5WLUP
-0.000 35.804 -1.462 -3.475 -0.021 35.932
17:1.2D+1.6L+0.5WDN
-0.000 65.579 -1.462 -3.475 -0.021 35.813
18:1.2DL+LL+WLUP-0.000 2.016 -2.924 -6.950 -0.042 72.198

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 13 of 159
Job No Sheet No Rev
1 14 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Reactions Cont...
Horizontal Vertical Horizontal Moment
Node L/C FX FY FZ MX MY MZ
(kN) (kN) (kN) (kN-m) (kN-m) (kN-m)
56 1:DL -0.000 19.493 0 0 0 -0.124
2:LL -0.000 21.000 0 0 0 -0.084
3:WIND UP -0.000 -42.375 -2.924 -6.950 -0.042 72.431
4:WIND DN -0.000 42.375 -2.924 -6.950 -0.042 72.092
5:WIND +Z 0 0 -3.376 -8.023 -0.025 0
6:WIND -Z 0 0 3.376 8.023 0.025 0
7:1.2DL+LL+WLDN -0.000 86.766 -2.924 -6.950 -0.042 71.859
8:0.9DL+WLUP -0.000 -24.832 -2.924 -6.950 -0.042 72.319
9:0.9DL+WLDN -0.000 59.918 -2.924 -6.950 -0.042 71.980
10:DL+LL+WL UP -0.000 -1.882 -2.924 -6.950 -0.042 72.223
11:DL+LL+WL DN -0.000 82.868 -2.924 -6.950 -0.042 71.884
14:1.4D -0.000 27.290 0 0 0 -0.173
15:1.2D+1.6L -0.000 56.991 0 0 0 -0.283
16:1.2D+1.6L+0.5WLUP
-0.000 35.804 -1.462 -3.475 -0.021 35.932
17:1.2D+1.6L+0.5WDN
-0.000 65.579 -1.462 -3.475 -0.021 35.813
18:1.2DL+LL+WLUP-0.000 2.016 -2.924 -6.950 -0.042 72.198
71 1:DL -0.000 12.885 0 0 0 -0.097
2:LL -0.000 10.500 0 0 0 -0.042
3:WIND UP -0.000 -21.187 -2.924 -6.950 -0.042 36.215
4:WIND DN -0.000 21.187 -2.924 -6.950 -0.042 36.046
5:WIND +Z 0 0 -3.376 -8.023 -0.025 0
6:WIND -Z 0 0 3.376 8.023 0.025 0
7:1.2DL+LL+WLDN -0.000 47.149 -2.924 -6.950 -0.042 35.887
8:0.9DL+WLUP -0.000 -9.591 -2.924 -6.950 -0.042 36.128
9:0.9DL+WLDN -0.000 32.784 -2.924 -6.950 -0.042 35.958
10:DL+LL+WL UP -0.000 2.197 -2.924 -6.950 -0.042 36.076
11:DL+LL+WL DN -0.000 44.572 -2.924 -6.950 -0.042 35.906
14:1.4D -0.000 18.039 0 0 0 -0.136
15:1.2D+1.6L -0.000 32.262 0 0 0 -0.184
16:1.2D+1.6L+0.5WLUP
-0.000 21.668 -1.462 -3.475 -0.021 17.924
17:1.2D+1.6L+0.5WDN
-0.000 36.556 -1.462 -3.475 -0.021 17.864
18:1.2DL+LL+WLUP-0.000 4.774 -2.924 -6.950 -0.042 36.056

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 14 of 159
Job No Sheet No Rev
1 15 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Reaction Summary
Horizontal Vertical Horizontal Moment
Node L/C FX FY FZ MX MY MZ
(kN) (kN) (kN) (kN-m) (kN-m) (kN-m)
Max FX 26 2:LL 0.000 21.000 0 0 0 -0.084
Min FX 56 14:1.4D -0.000 27.290 0 0 0 -0.173
Max FY 26 7:1.2DL+LL+WLDN -0.000 86.766 -2.924 -6.950 -0.042 71.859
Min FY 26 3:WIND UP -0.000 -42.375 -2.924 -6.950 -0.042 72.431
Max FZ 1 6:WIND -Z 0 0 3.376 8.023 0.025 0
Min FZ 1 5:WIND +Z 0 0 -3.376 -8.023 -0.025 0
Max MX 1 6:WIND -Z 0 0 3.376 8.023 0.025 0
Min MX 1 5:WIND +Z 0 0 -3.376 -8.023 -0.025 0
Max MY 1 6:WIND -Z 0 0 3.376 8.023 0.025 0
Min MY 1 3:WIND UP -0.000 -21.188 -2.924 -6.950 -0.042 36.215
Max MZ 26 3:WIND UP -0.000 -42.375 -2.924 -6.950 -0.042 72.431
Min MZ 26 15:1.2D+1.6L -0.000 56.991 0 0 0 -0.283

Y
X
Z
Load 3 : Torsion : Bending Z : Bending Y

Whole Structure My 0.085kN-m:1mm Mz 0.085kN-m:1mm Mx 0.007kN-m:1mm 3 WIND UP

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 15 of 159
Job No Sheet No Rev
1 16 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Y
X
Z
Load 3 : Beam Stress

Whole Structure Beam Stress 999999mm:mm 3 WIND UP

Utilization Ratio
Beam Analysis Design Actual Allowable Ratio Clause L/C Ax Iz Iy Ix
Property Property Ratio Ratio (Act./Allow.) (cm2) (cm4) (cm4) (cm4)
1 Taper Taper 0.459 1.000 0.459 LRFD-H1-1B-C 7 68.400 25.4E+3 564.548 18.192
2 Taper Taper 0.349 1.000 0.349 DEFLECTION 7 120.400 321E+3 567.321 29.285
15 Taper Taper 0.636 1.000 0.636 LRFD-H1-1B-C 7 68.400 25.4E+3 564.548 18.192
16 Taper Taper 0.382 1.000 0.382 LRFD-H1-1B-C 7 120.400 321E+3 567.321 29.285
29 Taper Taper 0.636 1.000 0.636 LRFD-H1-1B-C 7 68.400 25.4E+3 564.548 18.192
30 Taper Taper 0.382 1.000 0.382 LRFD-H1-1B-C 7 120.400 321E+3 567.321 29.285
43 Taper Taper 0.636 1.000 0.636 LRFD-H1-1B-C 7 68.400 25.4E+3 564.548 18.192
44 Taper Taper 0.382 1.000 0.382 LRFD-H1-1B-C 7 120.400 321E+3 567.321 29.285
57 Taper Taper 0.459 1.000 0.459 LRFD-H1-1B-C 7 68.400 25.4E+3 564.548 18.192
58 Taper Taper 0.349 1.000 0.349 DEFLECTION 7 120.400 321E+3 567.321 29.285
72 200CLAW65X20
N/A 6.650 392.900 32.270 0.091
73 200CLAW65X20
N/A 6.650 392.900 32.270 0.091
74 200CLAW65X20
N/A 6.650 392.900 32.270 0.091
75 200CLAW65X20
N/A 6.650 392.900 32.270 0.091
76 200CLAW65X20
N/A 6.650 392.900 32.270 0.091
77 200CLAW65X20
N/A 6.650 392.900 32.270 0.091
78 200CLAW65X20
N/A 6.650 392.900 32.270 0.091
79 200CLAW65X20
N/A 6.650 392.900 32.270 0.091
80 200CLAW65X20
N/A 6.650 392.900 32.270 0.091
81 200CLAW65X20
N/A 6.650 392.900 32.270 0.091
84 200CLAW65X20
N/A 6.650 392.900 32.270 0.091
85 200CLAW65X20
N/A 6.650 392.900 32.270 0.091
86 200CLAW65X20
N/A 6.650 392.900 32.270 0.091
87 200CLAW65X20
N/A 6.650 392.900 32.270 0.091
88 200CLAW65X20
N/A 6.650 392.900 32.270 0.091
89 200CLAW65X20
N/A 6.650 392.900 32.270 0.091
90 200CLAW65X20
N/A 6.650 392.900 32.270 0.091
91 200CLAW65X20
N/A 6.650 392.900 32.270 0.091
92 200CLAW65X20
N/A 6.650 392.900 32.270 0.091

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 16 of 159
Job No Sheet No Rev
1 17 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Utilization Ratio Cont...


Beam Analysis Design Actual Allowable Ratio Clause L/C Ax Iz Iy Ix
Property Property Ratio Ratio (Act./Allow.) (cm2) (cm4) (cm4) (cm4)
93 200CLAW65X20
N/A 6.650 392.900 32.270 0.091
96 200CLAW65X20
N/A 6.650 392.900 32.270 0.091
97 200CLAW65X20
N/A 6.650 392.900 32.270 0.091
98 200CLAW65X20
N/A 6.650 392.900 32.270 0.091
99 200CLAW65X20
N/A 6.650 392.900 32.270 0.091
100 200CLAW65X20
N/A 6.650 392.900 32.270 0.091
101 200CLAW65X20
N/A 6.650 392.900 32.270 0.091
102 200CLAW65X20
N/A 6.650 392.900 32.270 0.091
103 200CLAW65X20
N/A 6.650 392.900 32.270 0.091
104 200CLAW65X20
N/A 6.650 392.900 32.270 0.091
105 200CLAW65X20
N/A 6.650 392.900 32.270 0.091
108 200CLAW65X20
N/A 6.650 392.900 32.270 0.091
109 200CLAW65X20
N/A 6.650 392.900 32.270 0.091
110 200CLAW65X20
N/A 6.650 392.900 32.270 0.091
111 200CLAW65X20
N/A 6.650 392.900 32.270 0.091
112 200CLAW65X20
N/A 6.650 392.900 32.270 0.091
113 200CLAW65X20
N/A 6.650 392.900 32.270 0.091
114 200CLAW65X20
N/A 6.650 392.900 32.270 0.091
115 200CLAW65X20
N/A 6.650 392.900 32.270 0.091
116 200CLAW65X20
N/A 6.650 392.900 32.270 0.091
117 200CLAW65X20
N/A 6.650 392.900 32.270 0.091
275 Taper Taper 0.413 1.000 0.413 LRFD-H1-1B-C 7 66.970 23.4E+3 564.472 17.887
276 Taper Taper 0.349 1.000 0.349 DEFLECTION 7 66.970 23.4E+3 564.472 17.887
277 Taper Taper 0.355 1.000 0.355 LRFD-H1-1B-C 7 62.722 17.9E+3 564.245 16.981
278 Taper Taper 0.349 1.000 0.349 DEFLECTION 7 57.037 11.8E+3 563.942 15.768
279 Taper Taper 0.349 1.000 0.349 DEFLECTION 7 51.352 7.18E+3 563.639 14.555
280 Taper Taper 0.349 1.000 0.349 DEFLECTION 7 47.101 4.45E+3 563.412 13.648
281 Taper Taper 0.349 1.000 0.349 DEFLECTION 7 44.234 3.06E+3 563.259 13.037
282 Taper Taper 0.349 1.000 0.349 DEFLECTION 7 62.722 17.9E+3 564.245 16.981
283 Taper Taper 0.349 1.000 0.349 DEFLECTION 7 57.037 11.8E+3 563.942 15.768
284 Taper Taper 0.349 1.000 0.349 DEFLECTION 7 51.352 7.18E+3 563.639 14.555
285 Taper Taper 0.349 1.000 0.349 DEFLECTION 7 47.101 4.45E+3 563.412 13.648
286 Taper Taper 0.349 1.000 0.349 DEFLECTION 7 44.234 3.06E+3 563.259 13.037
287 Taper Taper 0.694 1.000 0.694 LRFD-H1-1B-C 7 66.970 23.4E+3 564.472 17.887
288 Taper Taper 0.474 1.000 0.474 LRFD-H1-1B-C 3 66.970 23.4E+3 564.472 17.887
289 Taper Taper 0.605 1.000 0.605 LRFD-H1-1B-C 7 62.722 17.9E+3 564.245 16.981
290 Taper Taper 0.442 1.000 0.442 LRFD-H1-1B-C 7 57.037 11.8E+3 563.942 15.768
291 Taper Taper 0.349 1.000 0.349 DEFLECTION 7 51.352 7.18E+3 563.639 14.555
292 Taper Taper 0.349 1.000 0.349 DEFLECTION 7 47.101 4.45E+3 563.412 13.648
293 Taper Taper 0.349 1.000 0.349 DEFLECTION 7 44.234 3.06E+3 563.259 13.037
294 Taper Taper 0.411 1.000 0.411 LRFD-H1-1B-C 3 62.722 17.9E+3 564.245 16.981
295 Taper Taper 0.349 1.000 0.349 DEFLECTION 7 57.037 11.8E+3 563.942 15.768
296 Taper Taper 0.349 1.000 0.349 DEFLECTION 7 51.352 7.18E+3 563.639 14.555
297 Taper Taper 0.349 1.000 0.349 DEFLECTION 7 47.101 4.45E+3 563.412 13.648
298 Taper Taper 0.349 1.000 0.349 DEFLECTION 7 44.234 3.06E+3 563.259 13.037
299 Taper Taper 0.694 1.000 0.694 LRFD-H1-1B-C 7 66.970 23.4E+3 564.472 17.887
300 Taper Taper 0.474 1.000 0.474 LRFD-H1-1B-C 3 66.970 23.4E+3 564.472 17.887
301 Taper Taper 0.605 1.000 0.605 LRFD-H1-1B-C 7 62.722 17.9E+3 564.245 16.981
302 Taper Taper 0.442 1.000 0.442 LRFD-H1-1B-C 7 57.037 11.8E+3 563.942 15.768

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 17 of 159
Job No Sheet No Rev
1 18 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Utilization Ratio Cont...


Beam Analysis Design Actual Allowable Ratio Clause L/C Ax Iz Iy Ix
Property Property Ratio Ratio (Act./Allow.) (cm2) (cm4) (cm4) (cm4)
303 Taper Taper 0.349 1.000 0.349 DEFLECTION 7 51.352 7.18E+3 563.639 14.555
304 Taper Taper 0.349 1.000 0.349 DEFLECTION 7 47.101 4.45E+3 563.412 13.648
305 Taper Taper 0.349 1.000 0.349 DEFLECTION 7 44.234 3.06E+3 563.259 13.037
306 Taper Taper 0.411 1.000 0.411 LRFD-H1-1B-C 3 62.722 17.9E+3 564.245 16.981
307 Taper Taper 0.349 1.000 0.349 DEFLECTION 7 57.037 11.8E+3 563.942 15.768
308 Taper Taper 0.349 1.000 0.349 DEFLECTION 7 51.352 7.18E+3 563.639 14.555
309 Taper Taper 0.349 1.000 0.349 DEFLECTION 7 47.101 4.45E+3 563.412 13.648
310 Taper Taper 0.349 1.000 0.349 DEFLECTION 7 44.234 3.06E+3 563.259 13.037
311 Taper Taper 0.694 1.000 0.694 LRFD-H1-1B-C 7 66.970 23.4E+3 564.472 17.887
312 Taper Taper 0.474 1.000 0.474 LRFD-H1-1B-C 3 66.970 23.4E+3 564.472 17.887
313 Taper Taper 0.605 1.000 0.605 LRFD-H1-1B-C 7 62.722 17.9E+3 564.245 16.981
314 Taper Taper 0.442 1.000 0.442 LRFD-H1-1B-C 7 57.037 11.8E+3 563.942 15.768
315 Taper Taper 0.349 1.000 0.349 DEFLECTION 7 51.352 7.18E+3 563.639 14.555
316 Taper Taper 0.349 1.000 0.349 DEFLECTION 7 47.101 4.45E+3 563.412 13.648
317 Taper Taper 0.349 1.000 0.349 DEFLECTION 7 44.234 3.06E+3 563.259 13.037
318 Taper Taper 0.411 1.000 0.411 LRFD-H1-1B-C 3 62.722 17.9E+3 564.245 16.981
319 Taper Taper 0.349 1.000 0.349 DEFLECTION 7 57.037 11.8E+3 563.942 15.768
320 Taper Taper 0.349 1.000 0.349 DEFLECTION 7 51.352 7.18E+3 563.639 14.555
321 Taper Taper 0.349 1.000 0.349 DEFLECTION 7 47.101 4.45E+3 563.412 13.648
322 Taper Taper 0.349 1.000 0.349 DEFLECTION 7 44.234 3.06E+3 563.259 13.037
323 Taper Taper 0.413 1.000 0.413 LRFD-H1-1B-C 7 66.970 23.4E+3 564.472 17.887
324 Taper Taper 0.349 1.000 0.349 DEFLECTION 7 66.970 23.4E+3 564.472 17.887
325 Taper Taper 0.355 1.000 0.355 LRFD-H1-1B-C 7 62.722 17.9E+3 564.245 16.981
326 Taper Taper 0.349 1.000 0.349 DEFLECTION 7 57.037 11.8E+3 563.942 15.768
327 Taper Taper 0.349 1.000 0.349 DEFLECTION 7 51.352 7.18E+3 563.639 14.555
328 Taper Taper 0.349 1.000 0.349 DEFLECTION 7 47.101 4.45E+3 563.412 13.648
329 Taper Taper 0.349 1.000 0.349 DEFLECTION 7 44.234 3.06E+3 563.259 13.037
330 Taper Taper 0.349 1.000 0.349 DEFLECTION 7 62.722 17.9E+3 564.245 16.981
331 Taper Taper 0.349 1.000 0.349 DEFLECTION 7 57.037 11.8E+3 563.942 15.768
332 Taper Taper 0.349 1.000 0.349 DEFLECTION 7 51.352 7.18E+3 563.639 14.555
333 Taper Taper 0.349 1.000 0.349 DEFLECTION 7 47.101 4.45E+3 563.412 13.648
334 Taper Taper 0.349 1.000 0.349 DEFLECTION 7 44.234 3.06E+3 563.259 13.037

Failed Members
There is no data of this type.

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 18 of 159
Job No Sheet No Rev
1 19 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

0.349
0.349
0.349
0.349
0.355
0.413
0.349 0.349
0.349
0.349 0.349
0.349
0.349 0.442
0.349 0.605
0.349 0.459 0.694 0.349
0.349 0.474 0.349
0.382
0.411 0.349
0.349 0.442
0.349 0.605
0.349 0.636 0.694 0.349
0.349 0.474 0.349
0.382
0.411 0.349
0.349 0.442
0.349 0.605
0.349 0.636 0.694 0.349
0.349 0.474 0.349
0.382
0.411 0.349
0.349 0.349
0.349 0.355
0.349 0.636 0.413
0.349 0.349
0.349
0.349
0.349
0.349
0.349 0.459
0.349

Y
X
Z
Load 3
UTILIZATION RATIO

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 19 of 159
Job No Sheet No Rev
1 20 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Steel Design (Track 2) Beam 1 Check 1


|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CMS UNIT |
| * |=============================| ==| |== ------------ |
|MEMBER 1 * | AISC SECTIONS | | | AX=0.6840E+2 |
| * | TAP ERED | | | --Z AY=0.4000E+2 |
|DESIGN CODE * | | | | AZ=0.2000E+2 |
| LRFD 2001 * =============================== ==| |== PY=0.1202E+3 |
| * PZ=0.1196E+4 |
| * |<---LENGTH (M)= 1.90 --->| RY=0.2873E+1 |
|************* RZ=0.1926E+2 |
| |
| 36.2 (KNS-METRE) |
|PARAMETER | L3 L3 L3 CAPACITIES |
|IN KNS CMS | L3 L3 L3 IN KNS METRE |
|--------------- + L3 L3 L3 -------------|
| KL/R-Y= 132.06 | L3 L3 L3 PNC=0.5894E+3|
| KL/R-Z= 9.85 + L3 L3 L3 pnc=0.4715E+2|
| UNL = 189.70 |L3 L3 L3 L3 L3 L3 L3 L3 PNT=0.1528E+4|
| CB = 1.00 +L3 L3 L3 L3 L3 L3 L3 L3 pnt=0.0000E+0|
| PHIC = 0.85 |L3 L3 L3 L3 L3 L3 L3 L3 MNZ=0.2509E+3|
| PHIB = 0.90 +L3 L3 L3 L3 L3 L3 L3 L3 mnz=0.3589E+2|
| FYLD = 24.82 |L3 L3 L3 L3 L3 L3 L3 L3 MNY=0.2522E+2|
| NSF = 1.00 +---+---+---+---+---+---+---+---+---+---| mny=0.6950E+1|
| DFF = 58.11 36.2 VN =0.5361E+3|
| dff = 166.27 ABSOLUTE MZ ENVELOPE vn =0.0000E+0|
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY (KNS-METRE) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 47.1 0.0 3.4 8.0 36.2 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 7 0 5 5 3 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY (KNS-METRE) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS LRFD-H1-1B-C 0.459 7 |
| 47.15 C 6.95 35.89 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 20 of 159
Job No Sheet No Rev
1 21 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

1 TAP ERED (AISC SECTIONS

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 21 of 159
Job No Sheet No Rev
1 22 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Steel Design (Track 2) Beam 2 Check 1


|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CMS UNIT |
| * |=============================| ==| |== ------------ |
|MEMBER 2 * | AISC SECTIONS | | | AX=0.6840E+2 |
| * | TAP ERED | | | --Z AY=0.4000E+2 |
|DESIGN CODE * | | | | AZ=0.2000E+2 |
| LRFD 2001 * =============================== ==| |== PY=0.1410E+3 |
| * PZ=0.9022E+4 |
| * |<---LENGTH (M)= 0.88 --->| RY=0.2873E+1 |
|************* RZ=0.1926E+2 |
| |
| 36.2 (KNS-METRE) |
|PARAMETER | L3 L3 L3 CAPACITIES |
|IN KNS CMS | L3 L3 L3 IN KNS METRE |
|--------------- + L3 L3 L3 -------------|
| KL/R-Y= 60.92 | L3 L3 L3 PNC=0.1193E+4|
| KL/R-Z= 4.54 + L3 L3 L3 pnc=0.4595E+2|
| UNL = 87.52 |L3 L3 L3 L3 L3 L3 L3 L3 PNT=0.1528E+4|
| CB = 1.00 +L3 L3 L3 L3 L3 L3 L3 L3 pnt=0.0000E+0|
| PHIC = 0.85 |L3 L3 L3 L3 L3 L3 L3 L3 MNZ=0.2671E+3|
| PHIB = 0.90 +L3 L3 L3 L3 L3 L3 L3 L3 mnz=0.3589E+2|
| FYLD = 24.82 |L3 L3 L3 L3 L3 L3 L3 L3 MNY=0.2522E+2|
| NSF = 1.00 +---+---+---+---+---+---+---+---+---+---| mny=0.1944E+1|
| DFF = 58.11 36.2 VN =0.5361E+3|
| dff = 166.27 ABSOLUTE MZ ENVELOPE vn =0.0000E+0|
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY (KNS-METRE) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 46.0 0.0 2.8 2.2 36.2 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 7 0 5 5 3 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY (KNS-METRE) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS DEFLECTION 0.349 7 |
| 45.95 C 1.94 35.89 0.88 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 22 of 159
Job No Sheet No Rev
1 23 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

2 TAP ERED (AISC SECTIONS

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 23 of 159
Job No Sheet No Rev
1 24 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Steel Design (Track 2) Beam 15 Check 1


|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CMS UNIT |
| * |=============================| ==| |== ------------ |
|MEMBER 15 * | AISC SECTIONS | | | AX=0.6840E+2 |
| * | TAP ERED | | | --Z AY=0.4000E+2 |
|DESIGN CODE * | | | | AZ=0.2000E+2 |
| LRFD 2001 * =============================== ==| |== PY=0.1202E+3 |
| * PZ=0.1196E+4 |
| * |<---LENGTH (M)= 1.90 --->| RY=0.2873E+1 |
|************* RZ=0.1926E+2 |
| |
| 72.4 (KNS-METRE) |
|PARAMETER | L3 L3 L3 CAPACITIES |
|IN KNS CMS | L3 L3 L3 IN KNS METRE |
|--------------- + L3 L3 L3 -------------|
| KL/R-Y= 132.06 | L3 L3 L3 PNC=0.5894E+3|
| KL/R-Z= 9.85 + L3 L3 L3 pnc=0.8677E+2|
| UNL = 189.70 |L3 L3 L3 L3 L3 L3 L3 L3 PNT=0.1528E+4|
| CB = 1.00 +L3 L3 L3 L3 L3 L3 L3 L3 pnt=0.0000E+0|
| PHIC = 0.85 |L3 L3 L3 L3 L3 L3 L3 L3 MNZ=0.2509E+3|
| PHIB = 0.90 +L3 L3 L3 L3 L3 L3 L3 L3 mnz=0.7186E+2|
| FYLD = 24.82 |L3 L3 L3 L3 L3 L3 L3 L3 MNY=0.2522E+2|
| NSF = 1.00 +---+---+---+---+---+---+---+---+---+---| mny=0.6950E+1|
| DFF = 58.11 72.4 VN =0.5361E+3|
| dff = 166.27 ABSOLUTE MZ ENVELOPE vn =0.0000E+0|
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY (KNS-METRE) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 86.8 0.0 3.4 8.0 72.4 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 7 0 5 5 3 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY (KNS-METRE) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS LRFD-H1-1B-C 0.636 7 |
| 86.77 C 6.95 71.86 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 24 of 159
Job No Sheet No Rev
1 25 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

15 TAP ERED (AISC SECTIONS

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 25 of 159
Job No Sheet No Rev
1 26 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Steel Design (Track 2) Beam 16 Check 1


|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CMS UNIT |
| * |=============================| ==| |== ------------ |
|MEMBER 16 * | AISC SECTIONS | | | AX=0.6840E+2 |
| * | TAP ERED | | | --Z AY=0.4000E+2 |
|DESIGN CODE * | | | | AZ=0.2000E+2 |
| LRFD 2001 * =============================== ==| |== PY=0.1410E+3 |
| * PZ=0.9022E+4 |
| * |<---LENGTH (M)= 0.88 --->| RY=0.2873E+1 |
|************* RZ=0.1926E+2 |
| |
| 72.4 (KNS-METRE) |
|PARAMETER | L3 L3 L3 CAPACITIES |
|IN KNS CMS | L3 L3 L3 IN KNS METRE |
|--------------- + L3 L3 L3 -------------|
| KL/R-Y= 60.92 | L3 L3 L3 PNC=0.1193E+4|
| KL/R-Z= 4.54 + L3 L3 L3 pnc=0.8557E+2|
| UNL = 87.52 |L3 L3 L3 L3 L3 L3 L3 L3 PNT=0.1528E+4|
| CB = 1.00 +L3 L3 L3 L3 L3 L3 L3 L3 pnt=0.0000E+0|
| PHIC = 0.85 |L3 L3 L3 L3 L3 L3 L3 L3 MNZ=0.2671E+3|
| PHIB = 0.90 +L3 L3 L3 L3 L3 L3 L3 L3 mnz=0.7186E+2|
| FYLD = 24.82 |L3 L3 L3 L3 L3 L3 L3 L3 MNY=0.2522E+2|
| NSF = 1.00 +---+---+---+---+---+---+---+---+---+---| mny=0.1944E+1|
| DFF = 58.11 72.4 VN =0.5361E+3|
| dff = 166.27 ABSOLUTE MZ ENVELOPE vn =0.0000E+0|
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY (KNS-METRE) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 85.6 0.0 2.8 2.2 72.4 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 7 0 5 5 3 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY (KNS-METRE) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS LRFD-H1-1B-C 0.382 7 |
| 85.57 C 1.94 71.86 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 26 of 159
Job No Sheet No Rev
1 27 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

16 TAP ERED (AISC SECTIONS

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 27 of 159
Job No Sheet No Rev
1 28 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Steel Design (Track 2) Beam 29 Check 1


|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CMS UNIT |
| * |=============================| ==| |== ------------ |
|MEMBER 29 * | AISC SECTIONS | | | AX=0.6840E+2 |
| * | TAP ERED | | | --Z AY=0.4000E+2 |
|DESIGN CODE * | | | | AZ=0.2000E+2 |
| LRFD 2001 * =============================== ==| |== PY=0.1202E+3 |
| * PZ=0.1196E+4 |
| * |<---LENGTH (M)= 1.90 --->| RY=0.2873E+1 |
|************* RZ=0.1926E+2 |
| |
| 72.4 (KNS-METRE) |
|PARAMETER | L3 L3 L3 CAPACITIES |
|IN KNS CMS | L3 L3 L3 IN KNS METRE |
|--------------- + L3 L3 L3 -------------|
| KL/R-Y= 132.06 | L3 L3 L3 PNC=0.5894E+3|
| KL/R-Z= 9.85 + L3 L3 L3 pnc=0.8677E+2|
| UNL = 189.70 |L3 L3 L3 L3 L3 L3 L3 L3 PNT=0.1528E+4|
| CB = 1.00 +L3 L3 L3 L3 L3 L3 L3 L3 pnt=0.0000E+0|
| PHIC = 0.85 |L3 L3 L3 L3 L3 L3 L3 L3 MNZ=0.2509E+3|
| PHIB = 0.90 +L3 L3 L3 L3 L3 L3 L3 L3 mnz=0.7186E+2|
| FYLD = 24.82 |L3 L3 L3 L3 L3 L3 L3 L3 MNY=0.2522E+2|
| NSF = 1.00 +---+---+---+---+---+---+---+---+---+---| mny=0.6950E+1|
| DFF = 58.11 72.4 VN =0.5361E+3|
| dff = 166.27 ABSOLUTE MZ ENVELOPE vn =0.0000E+0|
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY (KNS-METRE) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 86.8 0.0 3.4 8.0 72.4 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 7 0 5 5 3 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY (KNS-METRE) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS LRFD-H1-1B-C 0.636 7 |
| 86.77 C 6.95 71.86 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 28 of 159
Job No Sheet No Rev
1 29 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

29 TAP ERED (AISC SECTIONS

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 29 of 159
Job No Sheet No Rev
1 30 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Steel Design (Track 2) Beam 30 Check 1


|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CMS UNIT |
| * |=============================| ==| |== ------------ |
|MEMBER 30 * | AISC SECTIONS | | | AX=0.6840E+2 |
| * | TAP ERED | | | --Z AY=0.4000E+2 |
|DESIGN CODE * | | | | AZ=0.2000E+2 |
| LRFD 2001 * =============================== ==| |== PY=0.1410E+3 |
| * PZ=0.9022E+4 |
| * |<---LENGTH (M)= 0.88 --->| RY=0.2873E+1 |
|************* RZ=0.1926E+2 |
| |
| 72.4 (KNS-METRE) |
|PARAMETER | L3 L3 L3 CAPACITIES |
|IN KNS CMS | L3 L3 L3 IN KNS METRE |
|--------------- + L3 L3 L3 -------------|
| KL/R-Y= 60.92 | L3 L3 L3 PNC=0.1193E+4|
| KL/R-Z= 4.54 + L3 L3 L3 pnc=0.8557E+2|
| UNL = 87.52 |L3 L3 L3 L3 L3 L3 L3 L3 PNT=0.1528E+4|
| CB = 1.00 +L3 L3 L3 L3 L3 L3 L3 L3 pnt=0.0000E+0|
| PHIC = 0.85 |L3 L3 L3 L3 L3 L3 L3 L3 MNZ=0.2671E+3|
| PHIB = 0.90 +L3 L3 L3 L3 L3 L3 L3 L3 mnz=0.7186E+2|
| FYLD = 24.82 |L3 L3 L3 L3 L3 L3 L3 L3 MNY=0.2522E+2|
| NSF = 1.00 +---+---+---+---+---+---+---+---+---+---| mny=0.1944E+1|
| DFF = 58.11 72.4 VN =0.5361E+3|
| dff = 166.27 ABSOLUTE MZ ENVELOPE vn =0.0000E+0|
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY (KNS-METRE) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 85.6 0.0 2.8 2.2 72.4 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 7 0 5 5 3 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY (KNS-METRE) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS LRFD-H1-1B-C 0.382 7 |
| 85.57 C 1.94 71.86 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 30 of 159
Job No Sheet No Rev
1 31 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

30 TAP ERED (AISC SECTIONS

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 31 of 159
Job No Sheet No Rev
1 32 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Steel Design (Track 2) Beam 43 Check 1


|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CMS UNIT |
| * |=============================| ==| |== ------------ |
|MEMBER 43 * | AISC SECTIONS | | | AX=0.6840E+2 |
| * | TAP ERED | | | --Z AY=0.4000E+2 |
|DESIGN CODE * | | | | AZ=0.2000E+2 |
| LRFD 2001 * =============================== ==| |== PY=0.1202E+3 |
| * PZ=0.1196E+4 |
| * |<---LENGTH (M)= 1.90 --->| RY=0.2873E+1 |
|************* RZ=0.1926E+2 |
| |
| 72.4 (KNS-METRE) |
|PARAMETER | L3 L3 L3 CAPACITIES |
|IN KNS CMS | L3 L3 L3 IN KNS METRE |
|--------------- + L3 L3 L3 -------------|
| KL/R-Y= 132.06 | L3 L3 L3 PNC=0.5894E+3|
| KL/R-Z= 9.85 + L3 L3 L3 pnc=0.8677E+2|
| UNL = 189.70 |L3 L3 L3 L3 L3 L3 L3 L3 PNT=0.1528E+4|
| CB = 1.00 +L3 L3 L3 L3 L3 L3 L3 L3 pnt=0.0000E+0|
| PHIC = 0.85 |L3 L3 L3 L3 L3 L3 L3 L3 MNZ=0.2509E+3|
| PHIB = 0.90 +L3 L3 L3 L3 L3 L3 L3 L3 mnz=0.7186E+2|
| FYLD = 24.82 |L3 L3 L3 L3 L3 L3 L3 L3 MNY=0.2522E+2|
| NSF = 1.00 +---+---+---+---+---+---+---+---+---+---| mny=0.6950E+1|
| DFF = 58.11 72.4 VN =0.5361E+3|
| dff = 166.27 ABSOLUTE MZ ENVELOPE vn =0.0000E+0|
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY (KNS-METRE) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 86.8 0.0 3.4 8.0 72.4 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 7 0 5 5 3 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY (KNS-METRE) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS LRFD-H1-1B-C 0.636 7 |
| 86.77 C 6.95 71.86 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 32 of 159
Job No Sheet No Rev
1 33 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

43 TAP ERED (AISC SECTIONS

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 33 of 159
Job No Sheet No Rev
1 34 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Steel Design (Track 2) Beam 44 Check 1


|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CMS UNIT |
| * |=============================| ==| |== ------------ |
|MEMBER 44 * | AISC SECTIONS | | | AX=0.6840E+2 |
| * | TAP ERED | | | --Z AY=0.4000E+2 |
|DESIGN CODE * | | | | AZ=0.2000E+2 |
| LRFD 2001 * =============================== ==| |== PY=0.1410E+3 |
| * PZ=0.9022E+4 |
| * |<---LENGTH (M)= 0.88 --->| RY=0.2873E+1 |
|************* RZ=0.1926E+2 |
| |
| 72.4 (KNS-METRE) |
|PARAMETER | L3 L3 L3 CAPACITIES |
|IN KNS CMS | L3 L3 L3 IN KNS METRE |
|--------------- + L3 L3 L3 -------------|
| KL/R-Y= 60.92 | L3 L3 L3 PNC=0.1193E+4|
| KL/R-Z= 4.54 + L3 L3 L3 pnc=0.8557E+2|
| UNL = 87.52 |L3 L3 L3 L3 L3 L3 L3 L3 PNT=0.1528E+4|
| CB = 1.00 +L3 L3 L3 L3 L3 L3 L3 L3 pnt=0.0000E+0|
| PHIC = 0.85 |L3 L3 L3 L3 L3 L3 L3 L3 MNZ=0.2671E+3|
| PHIB = 0.90 +L3 L3 L3 L3 L3 L3 L3 L3 mnz=0.7186E+2|
| FYLD = 24.82 |L3 L3 L3 L3 L3 L3 L3 L3 MNY=0.2522E+2|
| NSF = 1.00 +---+---+---+---+---+---+---+---+---+---| mny=0.1944E+1|
| DFF = 58.11 72.4 VN =0.5361E+3|
| dff = 166.27 ABSOLUTE MZ ENVELOPE vn =0.0000E+0|
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY (KNS-METRE) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 85.6 0.0 2.8 2.2 72.4 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 7 0 5 5 3 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY (KNS-METRE) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS LRFD-H1-1B-C 0.382 7 |
| 85.57 C 1.94 71.86 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 34 of 159
Job No Sheet No Rev
1 35 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

44 TAP ERED (AISC SECTIONS

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 35 of 159
Job No Sheet No Rev
1 36 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Steel Design (Track 2) Beam 57 Check 1


|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CMS UNIT |
| * |=============================| ==| |== ------------ |
|MEMBER 57 * | AISC SECTIONS | | | AX=0.6840E+2 |
| * | TAP ERED | | | --Z AY=0.4000E+2 |
|DESIGN CODE * | | | | AZ=0.2000E+2 |
| LRFD 2001 * =============================== ==| |== PY=0.1202E+3 |
| * PZ=0.1196E+4 |
| * |<---LENGTH (M)= 1.90 --->| RY=0.2873E+1 |
|************* RZ=0.1926E+2 |
| |
| 36.2 (KNS-METRE) |
|PARAMETER | L3 L3 L3 CAPACITIES |
|IN KNS CMS | L3 L3 L3 IN KNS METRE |
|--------------- + L3 L3 L3 -------------|
| KL/R-Y= 132.06 | L3 L3 L3 PNC=0.5894E+3|
| KL/R-Z= 9.85 + L3 L3 L3 pnc=0.4715E+2|
| UNL = 189.70 |L3 L3 L3 L3 L3 L3 L3 L3 PNT=0.1528E+4|
| CB = 1.00 +L3 L3 L3 L3 L3 L3 L3 L3 pnt=0.0000E+0|
| PHIC = 0.85 |L3 L3 L3 L3 L3 L3 L3 L3 MNZ=0.2509E+3|
| PHIB = 0.90 +L3 L3 L3 L3 L3 L3 L3 L3 mnz=0.3589E+2|
| FYLD = 24.82 |L3 L3 L3 L3 L3 L3 L3 L3 MNY=0.2522E+2|
| NSF = 1.00 +---+---+---+---+---+---+---+---+---+---| mny=0.6950E+1|
| DFF = 58.11 36.2 VN =0.5361E+3|
| dff = 166.27 ABSOLUTE MZ ENVELOPE vn =0.0000E+0|
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY (KNS-METRE) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 47.1 0.0 3.4 8.0 36.2 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 7 0 5 5 3 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY (KNS-METRE) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS LRFD-H1-1B-C 0.459 7 |
| 47.15 C 6.95 35.89 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 36 of 159
Job No Sheet No Rev
1 37 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

57 TAP ERED (AISC SECTIONS

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 37 of 159
Job No Sheet No Rev
1 38 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Steel Design (Track 2) Beam 58 Check 1


|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CMS UNIT |
| * |=============================| ==| |== ------------ |
|MEMBER 58 * | AISC SECTIONS | | | AX=0.6840E+2 |
| * | TAP ERED | | | --Z AY=0.4000E+2 |
|DESIGN CODE * | | | | AZ=0.2000E+2 |
| LRFD 2001 * =============================== ==| |== PY=0.1410E+3 |
| * PZ=0.9022E+4 |
| * |<---LENGTH (M)= 0.88 --->| RY=0.2873E+1 |
|************* RZ=0.1926E+2 |
| |
| 36.2 (KNS-METRE) |
|PARAMETER | L3 L3 L3 CAPACITIES |
|IN KNS CMS | L3 L3 L3 IN KNS METRE |
|--------------- + L3 L3 L3 -------------|
| KL/R-Y= 60.92 | L3 L3 L3 PNC=0.1193E+4|
| KL/R-Z= 4.54 + L3 L3 L3 pnc=0.4595E+2|
| UNL = 87.52 |L3 L3 L3 L3 L3 L3 L3 L3 PNT=0.1528E+4|
| CB = 1.00 +L3 L3 L3 L3 L3 L3 L3 L3 pnt=0.0000E+0|
| PHIC = 0.85 |L3 L3 L3 L3 L3 L3 L3 L3 MNZ=0.2671E+3|
| PHIB = 0.90 +L3 L3 L3 L3 L3 L3 L3 L3 mnz=0.3589E+2|
| FYLD = 24.82 |L3 L3 L3 L3 L3 L3 L3 L3 MNY=0.2522E+2|
| NSF = 1.00 +---+---+---+---+---+---+---+---+---+---| mny=0.1944E+1|
| DFF = 58.11 36.2 VN =0.5361E+3|
| dff = 166.27 ABSOLUTE MZ ENVELOPE vn =0.0000E+0|
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY (KNS-METRE) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 46.0 0.0 2.8 2.2 36.2 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 7 0 5 5 3 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY (KNS-METRE) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS DEFLECTION 0.349 7 |
| 45.95 C 1.94 35.89 0.88 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 38 of 159
Job No Sheet No Rev
1 39 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

58 TAP ERED (AISC SECTIONS

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 39 of 159
Job No Sheet No Rev
1 40 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Steel Design (Track 2) Beam 275 Check 1


|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CMS UNIT |
| * |=============================| ==| |== ------------ |
|MEMBER 275 * | BS COLDFORMED SECTIONS | | | AX=0.6840E+2 |
| * | TAP ERED | | | --Z AY=0.4000E+2 |
|DESIGN CODE * | | | | AZ=0.2000E+2 |
| LRFD 2001 * =============================== ==| |== PY=0.1196E+3 |
| * PZ=0.1076E+4 |
| * |<---LENGTH (M)= 0.58 --->| RY=0.2873E+1 |
|************* RZ=0.1926E+2 |
| |
| 81.3 (KNS-METRE) |
|PARAMETER |L7 CAPACITIES |
|IN KNS CMS | L7 IN KNS METRE |
|--------------- + L7 L7 -------------|
| KL/R-Y= 20.08 | L7 PNC=0.1414E+4|
| KL/R-Z= 3.00 + pnc=0.1505E+1|
| UNL = 57.70 | L7 L7 PNT=0.1528E+4|
| CB = 1.00 + pnt=0.0000E+0|
| PHIC = 0.85 | L7 MNZ=0.2671E+3|
| PHIB = 0.90 + L7 L7 mnz=0.8134E+2|
| FYLD = 24.82 | L7 MNY=0.2522E+2|
| NSF = 1.00 +---+---+---+---+---+---+---+---+---+---| mny=0.2714E+1|
| DFF = 58.11 64.0 VN =0.5361E+3|
| dff = 166.27 ABSOLUTE MZ ENVELOPE vn =0.2872E+2|
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY (KNS-METRE) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 1.5 28.7 1.1 2.7 81.3 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 7 7 5 3 7 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY (KNS-METRE) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS LRFD-H1-1B-C 0.413 7 |
| 1.51 C 2.71 81.34 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 40 of 159
Job No Sheet No Rev
1 41 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

275 TAP ERED (BS COLDFORMED SECTIONS

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 41 of 159
Job No Sheet No Rev
1 42 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Steel Design (Track 2) Beam 276 Check 1


|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CMS UNIT |
| * |=============================| ==| |== ------------ |
|MEMBER 276 * | BS COLDFORMED SECTIONS | | | AX=0.6840E+2 |
| * | TAP ERED | | | --Z AY=0.4000E+2 |
|DESIGN CODE * | | | | AZ=0.2000E+2 |
| LRFD 2001 * =============================== ==| |== PY=0.1196E+3 |
| * PZ=0.1076E+4 |
| * |<---LENGTH (M)= 0.58 --->| RY=0.2873E+1 |
|************* RZ=0.1926E+2 |
| |
| 48.6 (KNS-METRE) |
|PARAMETER |L3 CAPACITIES |
|IN KNS CMS | L3 IN KNS METRE |
|--------------- + L3 L3 -------------|
| KL/R-Y= 20.08 | L3 PNC=0.1414E+4|
| KL/R-Z= 3.00 + pnc=0.0000E+0|
| UNL = 57.70 | L3 L3 PNT=0.1528E+4|
| CB = 1.00 + pnt=0.8484E+0|
| PHIC = 0.85 | L3 L3 MNZ=0.2671E+3|
| PHIB = 0.90 + L3 mnz=0.4546E+2|
| FYLD = 24.82 | L3 MNY=0.2522E+2|
| NSF = 1.00 +---+---+---+---+---+---+---+---+---+---| mny=0.2756E+1|
| DFF = 58.11 38.3 VN =0.5361E+3|
| dff = 166.27 ABSOLUTE MZ ENVELOPE vn =0.1619E+2|
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY (KNS-METRE) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 0.9 16.9 1.1 2.8 48.6 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 3 3 5 3 3 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY (KNS-METRE) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS DEFLECTION 0.349 7 |
| 0.85 T -2.76 45.46 0.58 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 42 of 159
Job No Sheet No Rev
1 43 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

276 TAP ERED (BS COLDFORMED SECTIONS

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 43 of 159
Job No Sheet No Rev
1 44 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Steel Design (Track 2) Beam 277 Check 1


|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CMS UNIT |
| * |=============================| ==| |== ------------ |
|MEMBER 277 * | BS COLDFORMED SECTIONS | | | AX=0.6554E+2 |
| * | TAP ERED | | | --Z AY=0.3714E+2 |
|DESIGN CODE * | | | | AZ=0.2000E+2 |
| LRFD 2001 * =============================== ==| |== PY=0.1185E+3 |
| * PZ=0.8552E+3 |
| * |<---LENGTH (M)= 1.14 --->| RY=0.2935E+1 |
|************* RZ=0.1804E+2 |
| |
| 64.9 (KNS-METRE) |
|PARAMETER |L7 CAPACITIES |
|IN KNS CMS | L7 IN KNS METRE |
|--------------- + L7 L7 -------------|
| KL/R-Y= 38.75 | L7 PNC=0.1280E+4|
| KL/R-Z= 6.30 + pnc=0.1213E+1|
| UNL = 113.70 | L7 L7 PNT=0.1464E+4|
| CB = 1.00 + pnt=0.0000E+0|
| PHIC = 0.85 | L7 MNZ=0.2404E+3|
| PHIB = 0.90 + L7 L7 mnz=0.6488E+2|
| FYLD = 24.82 | L7 MNY=0.2522E+2|
| NSF = 1.00 +---+---+---+---+---+---+---+---+---+---| mny=0.2146E+1|
| DFF = 58.11 37.5 VN =0.4978E+3|
| dff = 166.27 ABSOLUTE MZ ENVELOPE vn =0.2315E+2|
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY (KNS-METRE) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 1.2 23.2 0.9 2.1 64.9 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 7 7 3 3 7 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY (KNS-METRE) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS LRFD-H1-1B-C 0.355 7 |
| 1.21 C 2.15 64.88 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 44 of 159
Job No Sheet No Rev
1 45 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

277 TAP ERED (BS COLDFORMED SECTIONS

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 45 of 159
Job No Sheet No Rev
1 46 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Steel Design (Track 2) Beam 278 Check 1


|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CMS UNIT |
| * |=============================| ==| |== ------------ |
|MEMBER 278 * | BS COLDFORMED SECTIONS | | | AX=0.5990E+2 |
| * | TAP ERED | | | --Z AY=0.3150E+2 |
|DESIGN CODE * | | | | AZ=0.2000E+2 |
| LRFD 2001 * =============================== ==| |== PY=0.1173E+3 |
| * PZ=0.6507E+3 |
| * |<---LENGTH (M)= 1.16 --->| RY=0.3069E+1 |
|************* RZ=0.1558E+2 |
| |
| 38.9 (KNS-METRE) |
|PARAMETER |L7 CAPACITIES |
|IN KNS CMS | L7 IN KNS METRE |
|--------------- + L7 L7 -------------|
| KL/R-Y= 37.70 | L7 PNC=0.1175E+4|
| KL/R-Z= 7.43 + pnc=0.9059E+0|
| UNL = 115.70 | L7 L7 PNT=0.1338E+4|
| CB = 1.00 + pnt=0.0000E+0|
| PHIC = 0.85 | L7 MNZ=0.1910E+3|
| PHIB = 0.90 + L7 L7 mnz=0.3893E+2|
| FYLD = 24.82 | L7 MNY=0.2520E+2|
| NSF = 1.00 +---+---+---+---+---+---+---+---+---+---| mny=0.1222E+1|
| DFF = 58.11 18.2 VN =0.4223E+3|
| dff = 166.27 ABSOLUTE MZ ENVELOPE vn =0.1729E+2|
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY (KNS-METRE) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 0.9 17.3 0.7 1.2 38.9 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 7 7 3 3 7 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY (KNS-METRE) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS DEFLECTION 0.349 7 |
| 0.91 C 1.22 38.93 1.16 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 46 of 159
Job No Sheet No Rev
1 47 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

278 TAP ERED (BS COLDFORMED SECTIONS

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 47 of 159
Job No Sheet No Rev
1 48 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Steel Design (Track 2) Beam 279 Check 1


|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CMS UNIT |
| * |=============================| ==| |== ------------ |
|MEMBER 279 * | BS COLDFORMED SECTIONS | | | AX=0.5417E+2 |
| * | TAP ERED | | | --Z AY=0.2577E+2 |
|DESIGN CODE * | | | | AZ=0.2000E+2 |
| LRFD 2001 * =============================== ==| |== PY=0.1162E+3 |
| * PZ=0.4699E+3 |
| * |<---LENGTH (M)= 1.14 --->| RY=0.3226E+1 |
|************* RZ=0.1300E+2 |
| |
| 19.3 (KNS-METRE) |
|PARAMETER |L7 CAPACITIES |
|IN KNS CMS | L7 IN KNS METRE |
|--------------- + L7 L7 -------------|
| KL/R-Y= 35.24 | L7 PNC=0.1072E+4|
| KL/R-Z= 8.75 + pnc=0.6009E+0|
| UNL = 113.70 | L7 L7 PNT=0.1210E+4|
| CB = 1.00 + pnt=0.0000E+0|
| PHIC = 0.85 | L7 MNZ=0.1454E+3|
| PHIB = 0.90 + L7 L7 mnz=0.1929E+2|
| FYLD = 24.82 | L7 MNY=0.2519E+2|
| NSF = 1.00 +---+---+---+---+---+---+---+---+---+---| mny=0.5471E+0|
| DFF = 58.11 5.9 VN =0.3454E+3|
| dff = 166.27 ABSOLUTE MZ ENVELOPE vn =0.1147E+2|
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY (KNS-METRE) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 0.6 11.5 0.5 0.5 19.3 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 7 7 3 3 7 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY (KNS-METRE) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS DEFLECTION 0.349 7 |
| 0.60 C 0.55 19.29 1.14 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 48 of 159
Job No Sheet No Rev
1 49 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

279 TAP ERED (BS COLDFORMED SECTIONS

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 49 of 159
Job No Sheet No Rev
1 50 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Steel Design (Track 2) Beam 280 Check 1


|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CMS UNIT |
| * |=============================| ==| |== ------------ |
|MEMBER 280 * | BS COLDFORMED SECTIONS | | | AX=0.4853E+2 |
| * | TAP ERED | | | --Z AY=0.2013E+2 |
|DESIGN CODE * | | | | AZ=0.2000E+2 |
| LRFD 2001 * =============================== ==| |== PY=0.1156E+3 |
| * PZ=0.3855E+3 |
| * |<---LENGTH (M)= 0.58 --->| RY=0.3407E+1 |
|************* RZ=0.1036E+2 |
| |
| 6.6 (KNS-METRE) |
|PARAMETER |L7 CAPACITIES |
|IN KNS CMS | L7 IN KNS METRE |
|--------------- + L7 L7 -------------|
| KL/R-Y= 16.98 | L7 PNC=0.1009E+4|
| KL/R-Z= 5.58 + pnc=0.2996E+0|
| UNL = 57.85 | L7 L7 PNT=0.1084E+4|
| CB = 1.00 + pnt=0.0000E+0|
| PHIC = 0.85 | L7 MNZ=0.1050E+3|
| PHIB = 0.90 + L7 L7 mnz=0.6561E+1|
| FYLD = 24.82 | L7 MNY=0.2518E+2|
| NSF = 1.00 +---+---+---+---+---+---+---+---+---+---| mny=0.1445E+0|
| DFF = 58.11 3.1 VN =0.2699E+3|
| dff = 166.27 ABSOLUTE MZ ENVELOPE vn =0.5717E+1|
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY (KNS-METRE) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 0.3 5.7 0.2 0.1 6.6 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 7 7 3 3 7 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY (KNS-METRE) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS DEFLECTION 0.349 7 |
| 0.30 C 0.14 6.56 0.58 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 50 of 159
Job No Sheet No Rev
1 51 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

280 TAP ERED (BS COLDFORMED SECTIONS

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 51 of 159
Job No Sheet No Rev
1 52 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Steel Design (Track 2) Beam 281 Check 1


|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CMS UNIT |
| * |=============================| ==| |== ------------ |
|MEMBER 281 * | BS COLDFORMED SECTIONS | | | AX=0.4567E+2 |
| * | TAP ERED | | | --Z AY=0.1727E+2 |
|DESIGN CODE * | | | | AZ=0.2000E+2 |
| LRFD 2001 * =============================== ==| |== PY=0.1151E+3 |
| * PZ=0.3062E+3 |
| * |<---LENGTH (M)= 0.62 --->| RY=0.3512E+1 |
|************* RZ=0.8978E+1 |
| |
| 3.3 (KNS-METRE) |
|PARAMETER |L7 CAPACITIES |
|IN KNS CMS | L7 IN KNS METRE |
|--------------- + L7 L7 -------------|
| KL/R-Y= 17.75 | L7 PNC=0.9480E+3|
| KL/R-Z= 6.94 + pnc=0.2657E+0|
| UNL = 62.34 | L7 L7 PNT=0.1020E+4|
| CB = 1.00 + pnt=0.0000E+0|
| PHIC = 0.85 | L7 MNZ=0.8611E+2|
| PHIB = 0.90 + L7 L7 mnz=0.3328E+1|
| FYLD = 24.82 | L0 MNY=0.2517E+2|
| NSF = 1.00 +---+---+---+---+---+---+---+---+---+---| mny=0.3887E-1|
| DFF = 58.11 -0.2 VN =0.2314E+3|
| dff = 166.27 ABSOLUTE MZ ENVELOPE vn =0.5466E+1|
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY (KNS-METRE) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 0.3 5.5 0.1 0.0 3.3 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 7 7 3 3 7 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY (KNS-METRE) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS DEFLECTION 0.349 7 |
| 0.27 C 0.04 3.33 0.62 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 52 of 159
Job No Sheet No Rev
1 53 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

281 TAP ERED (BS COLDFORMED SECTIONS

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 53 of 159
Job No Sheet No Rev
1 54 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Steel Design (Track 2) Beam 282 Check 1


|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CMS UNIT |
| * |=============================| ==| |== ------------ |
|MEMBER 282 * | BS COLDFORMED SECTIONS | | | AX=0.6554E+2 |
| * | TAP ERED | | | --Z AY=0.3714E+2 |
|DESIGN CODE * | | | | AZ=0.2000E+2 |
| LRFD 2001 * =============================== ==| |== PY=0.1185E+3 |
| * PZ=0.8552E+3 |
| * |<---LENGTH (M)= 1.14 --->| RY=0.2935E+1 |
|************* RZ=0.1804E+2 |
| |
| 38.9 (KNS-METRE) |
|PARAMETER |L3 CAPACITIES |
|IN KNS CMS | L3 IN KNS METRE |
|--------------- + L3 -------------|
| KL/R-Y= 38.75 | L3 PNC=0.1280E+4|
| KL/R-Z= 6.30 + pnc=0.0000E+0|
| UNL = 113.70 | L3 PNT=0.1464E+4|
| CB = 1.00 + pnt=0.6883E+0|
| PHIC = 0.85 | L3 MNZ=0.2404E+3|
| PHIB = 0.90 + L3 mnz=0.3622E+2|
| FYLD = 24.82 | L3 MNY=0.2522E+2|
| NSF = 1.00 +---+---+---+---+---+---+---+---+---+---| mny=0.2184E+1|
| DFF = 58.11 22.7 VN =0.4978E+3|
| dff = 166.27 ABSOLUTE MZ ENVELOPE vn =0.1313E+2|
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY (KNS-METRE) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 0.7 13.5 0.9 2.2 38.9 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 3 3 3 3 3 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY (KNS-METRE) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS DEFLECTION 0.349 7 |
| 0.69 T -2.18 36.22 1.14 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 54 of 159
Job No Sheet No Rev
1 55 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

282 TAP ERED (BS COLDFORMED SECTIONS

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 55 of 159
Job No Sheet No Rev
1 56 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Steel Design (Track 2) Beam 283 Check 1


|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CMS UNIT |
| * |=============================| ==| |== ------------ |
|MEMBER 283 * | BS COLDFORMED SECTIONS | | | AX=0.5990E+2 |
| * | TAP ERED | | | --Z AY=0.3150E+2 |
|DESIGN CODE * | | | | AZ=0.2000E+2 |
| LRFD 2001 * =============================== ==| |== PY=0.1173E+3 |
| * PZ=0.6507E+3 |
| * |<---LENGTH (M)= 1.16 --->| RY=0.3069E+1 |
|************* RZ=0.1558E+2 |
| |
| 23.5 (KNS-METRE) |
|PARAMETER |L3 CAPACITIES |
|IN KNS CMS | L3 IN KNS METRE |
|--------------- + L3 L3 -------------|
| KL/R-Y= 37.70 | L3 PNC=0.1175E+4|
| KL/R-Z= 7.43 + L3 pnc=0.0000E+0|
| UNL = 115.70 | L3 L3 PNT=0.1338E+4|
| CB = 1.00 + pnt=0.5123E+0|
| PHIC = 0.85 | L3 L3 MNZ=0.1910E+3|
| PHIB = 0.90 + L3 mnz=0.2166E+2|
| FYLD = 24.82 | L3 MNY=0.2520E+2|
| NSF = 1.00 +---+---+---+---+---+---+---+---+---+---| mny=0.1250E+1|
| DFF = 58.11 11.2 VN =0.4223E+3|
| dff = 166.27 ABSOLUTE MZ ENVELOPE vn =0.9775E+1|
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY (KNS-METRE) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 0.5 10.1 0.7 1.3 23.5 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 3 3 3 3 3 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY (KNS-METRE) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS DEFLECTION 0.349 7 |
| 0.51 T -1.25 21.66 1.16 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 56 of 159
Job No Sheet No Rev
1 57 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

283 TAP ERED (BS COLDFORMED SECTIONS

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 57 of 159
Job No Sheet No Rev
1 58 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Steel Design (Track 2) Beam 284 Check 1


|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CMS UNIT |
| * |=============================| ==| |== ------------ |
|MEMBER 284 * | BS COLDFORMED SECTIONS | | | AX=0.5417E+2 |
| * | TAP ERED | | | --Z AY=0.2577E+2 |
|DESIGN CODE * | | | | AZ=0.2000E+2 |
| LRFD 2001 * =============================== ==| |== PY=0.1162E+3 |
| * PZ=0.4699E+3 |
| * |<---LENGTH (M)= 1.14 --->| RY=0.3226E+1 |
|************* RZ=0.1300E+2 |
| |
| 11.9 (KNS-METRE) |
|PARAMETER |L3 CAPACITIES |
|IN KNS CMS | L3 IN KNS METRE |
|--------------- + L3 L3 -------------|
| KL/R-Y= 35.24 | L3 PNC=0.1072E+4|
| KL/R-Z= 8.75 + L3 pnc=0.0000E+0|
| UNL = 113.70 | L3 PNT=0.1210E+4|
| CB = 1.00 + pnt=0.3388E+0|
| PHIC = 0.85 | L3 MNZ=0.1454E+3|
| PHIB = 0.90 + L3 L3 mnz=0.1071E+2|
| FYLD = 24.82 | L3 MNY=0.2519E+2|
| NSF = 1.00 +---+---+---+---+---+---+---+---+---+---| mny=0.5659E+0|
| DFF = 58.11 3.8 VN =0.3454E+3|
| dff = 166.27 ABSOLUTE MZ ENVELOPE vn =0.6464E+1|
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY (KNS-METRE) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 0.4 6.7 0.5 0.6 11.9 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 3 3 3 3 3 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY (KNS-METRE) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS DEFLECTION 0.349 7 |
| 0.34 T -0.57 10.71 1.14 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 58 of 159
Job No Sheet No Rev
1 59 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

284 TAP ERED (BS COLDFORMED SECTIONS

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 59 of 159
Job No Sheet No Rev
1 60 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Steel Design (Track 2) Beam 285 Check 1


|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CMS UNIT |
| * |=============================| ==| |== ------------ |
|MEMBER 285 * | BS COLDFORMED SECTIONS | | | AX=0.4853E+2 |
| * | TAP ERED | | | --Z AY=0.2013E+2 |
|DESIGN CODE * | | | | AZ=0.2000E+2 |
| LRFD 2001 * =============================== ==| |== PY=0.1156E+3 |
| * PZ=0.3855E+3 |
| * |<---LENGTH (M)= 0.58 --->| RY=0.3407E+1 |
|************* RZ=0.1036E+2 |
| |
| 4.2 (KNS-METRE) |
|PARAMETER |L3 CAPACITIES |
|IN KNS CMS | L3 IN KNS METRE |
|--------------- + L3 L3 -------------|
| KL/R-Y= 16.98 | L3 PNC=0.1009E+4|
| KL/R-Z= 5.58 + L3 pnc=0.0000E+0|
| UNL = 57.85 | L3 PNT=0.1084E+4|
| CB = 1.00 + pnt=0.1689E+0|
| PHIC = 0.85 | L3 L3 MNZ=0.1050E+3|
| PHIB = 0.90 + L3 mnz=0.3673E+1|
| FYLD = 24.82 | L3 MNY=0.2518E+2|
| NSF = 1.00 +---+---+---+---+---+---+---+---+---+---| mny=0.1542E+0|
| DFF = 58.11 2.1 VN =0.2699E+3|
| dff = 166.27 ABSOLUTE MZ ENVELOPE vn =0.3224E+1|
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY (KNS-METRE) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 0.2 3.4 0.2 0.2 4.2 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 3 3 3 3 3 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY (KNS-METRE) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS DEFLECTION 0.349 7 |
| 0.17 T -0.15 3.67 0.58 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 60 of 159
Job No Sheet No Rev
1 61 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

285 TAP ERED (BS COLDFORMED SECTIONS

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 61 of 159
Job No Sheet No Rev
1 62 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Steel Design (Track 2) Beam 286 Check 1


|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CMS UNIT |
| * |=============================| ==| |== ------------ |
|MEMBER 286 * | BS COLDFORMED SECTIONS | | | AX=0.4567E+2 |
| * | TAP ERED | | | --Z AY=0.1727E+2 |
|DESIGN CODE * | | | | AZ=0.2000E+2 |
| LRFD 2001 * =============================== ==| |== PY=0.1151E+3 |
| * PZ=0.3062E+3 |
| * |<---LENGTH (M)= 0.66 --->| RY=0.3512E+1 |
|************* RZ=0.8978E+1 |
| |
| 2.2 (KNS-METRE) |
|PARAMETER |L3 CAPACITIES |
|IN KNS CMS | L3 IN KNS METRE |
|--------------- + L3 L3 -------------|
| KL/R-Y= 18.89 | L3 PNC=0.9460E+3|
| KL/R-Z= 7.39 + L3 pnc=0.0000E+0|
| UNL = 66.34 | L3 PNT=0.1020E+4|
| CB = 1.00 + pnt=0.1358E+0|
| PHIC = 0.85 | L3 L3 MNZ=0.8611E+2|
| PHIB = 0.90 + L3 mnz=0.1882E+1|
| FYLD = 24.82 | L0 MNY=0.2517E+2|
| NSF = 1.00 +---+---+---+---+---+---+---+---+---+---| mny=0.4401E-1|
| DFF = 58.11 -0.1 VN =0.2314E+3|
| dff = 166.27 ABSOLUTE MZ ENVELOPE vn =0.2973E+1|
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY (KNS-METRE) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 0.2 3.4 0.1 0.0 2.2 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 3 3 3 3 3 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY (KNS-METRE) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS DEFLECTION 0.349 7 |
| 0.14 T -0.04 1.88 0.66 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 62 of 159
Job No Sheet No Rev
1 63 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

286 TAP ERED (BS COLDFORMED SECTIONS

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 63 of 159
Job No Sheet No Rev
1 64 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Steel Design (Track 2) Beam 287 Check 1


|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CMS UNIT |
| * |=============================| ==| |== ------------ |
|MEMBER 287 * | BS COLDFORMED SECTIONS | | | AX=0.6840E+2 |
| * | TAP ERED | | | --Z AY=0.4000E+2 |
|DESIGN CODE * | | | | AZ=0.2000E+2 |
| LRFD 2001 * =============================== ==| |== PY=0.1196E+3 |
| * PZ=0.1076E+4 |
| * |<---LENGTH (M)= 0.58 --->| RY=0.2873E+1 |
|************* RZ=0.1926E+2 |
| |
| 156.3 (KNS-METRE) |
|PARAMETER |L7 CAPACITIES |
|IN KNS CMS | L7 IN KNS METRE |
|--------------- + L7 L7 -------------|
| KL/R-Y= 20.08 | L7 PNC=0.1414E+4|
| KL/R-Z= 3.00 + pnc=0.2871E+1|
| UNL = 57.70 | L7 L7 PNT=0.1528E+4|
| CB = 1.00 + pnt=0.0000E+0|
| PHIC = 0.85 | L7 MNZ=0.2671E+3|
| PHIB = 0.90 + L7 L7 mnz=0.1563E+3|
| FYLD = 24.82 | L7 MNY=0.2522E+2|
| NSF = 1.00 +---+---+---+---+---+---+---+---+---+---| mny=0.2714E+1|
| DFF = 58.11 123.0 VN =0.5361E+3|
| dff = 166.27 ABSOLUTE MZ ENVELOPE vn =0.5478E+2|
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY (KNS-METRE) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 2.9 54.8 1.1 2.7 156.3 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 7 7 5 3 7 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY (KNS-METRE) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS LRFD-H1-1B-C 0.694 7 |
| 2.87 C 2.71 156.28 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 64 of 159
Job No Sheet No Rev
1 65 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

287 TAP ERED (BS COLDFORMED SECTIONS

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 65 of 159
Job No Sheet No Rev
1 66 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Steel Design (Track 2) Beam 288 Check 1


|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CMS UNIT |
| * |=============================| ==| |== ------------ |
|MEMBER 288 * | BS COLDFORMED SECTIONS | | | AX=0.6840E+2 |
| * | TAP ERED | | | --Z AY=0.4000E+2 |
|DESIGN CODE * | | | | AZ=0.2000E+2 |
| LRFD 2001 * =============================== ==| |== PY=0.1196E+3 |
| * PZ=0.1076E+4 |
| * |<---LENGTH (M)= 0.58 --->| RY=0.2873E+1 |
|************* RZ=0.1926E+2 |
| |
| 97.2 (KNS-METRE) |
|PARAMETER |L3 CAPACITIES |
|IN KNS CMS | L3 IN KNS METRE |
|--------------- + L3 L3 -------------|
| KL/R-Y= 20.08 | L3 PNC=0.1414E+4|
| KL/R-Z= 3.00 + pnc=0.1766E+1|
| UNL = 57.70 | L3 L3 PNT=0.1528E+4|
| CB = 1.00 + pnt=0.0000E+0|
| PHIC = 0.85 | L3 L3 MNZ=0.2671E+3|
| PHIB = 0.90 + L3 mnz=0.9720E+2|
| FYLD = 24.82 | L3 MNY=0.2522E+2|
| NSF = 1.00 +---+---+---+---+---+---+---+---+---+---| mny=0.2756E+1|
| DFF = 58.11 76.7 VN =0.5361E+3|
| dff = 166.27 ABSOLUTE MZ ENVELOPE vn =0.3370E+2|
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY (KNS-METRE) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 1.8 33.7 1.1 2.8 97.2 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 3 3 5 3 3 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY (KNS-METRE) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS LRFD-H1-1B-C 0.474 3 |
| 1.77 C -2.76 -97.20 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 66 of 159
Job No Sheet No Rev
1 67 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

288 TAP ERED (BS COLDFORMED SECTIONS

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 67 of 159
Job No Sheet No Rev
1 68 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Steel Design (Track 2) Beam 289 Check 1


|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CMS UNIT |
| * |=============================| ==| |== ------------ |
|MEMBER 289 * | BS COLDFORMED SECTIONS | | | AX=0.6554E+2 |
| * | TAP ERED | | | --Z AY=0.3714E+2 |
|DESIGN CODE * | | | | AZ=0.2000E+2 |
| LRFD 2001 * =============================== ==| |== PY=0.1185E+3 |
| * PZ=0.8552E+3 |
| * |<---LENGTH (M)= 1.14 --->| RY=0.2935E+1 |
|************* RZ=0.1804E+2 |
| |
| 124.8 (KNS-METRE) |
|PARAMETER |L7 CAPACITIES |
|IN KNS CMS | L7 IN KNS METRE |
|--------------- + L7 L7 -------------|
| KL/R-Y= 38.75 | L7 PNC=0.1280E+4|
| KL/R-Z= 6.30 + pnc=0.2306E+1|
| UNL = 113.70 | L7 L7 PNT=0.1464E+4|
| CB = 1.00 + pnt=0.0000E+0|
| PHIC = 0.85 | L7 MNZ=0.2404E+3|
| PHIB = 0.90 + L7 L7 mnz=0.1248E+3|
| FYLD = 24.82 | L7 MNY=0.2522E+2|
| NSF = 1.00 +---+---+---+---+---+---+---+---+---+---| mny=0.2146E+1|
| DFF = 58.11 72.4 VN =0.4978E+3|
| dff = 166.27 ABSOLUTE MZ ENVELOPE vn =0.4400E+2|
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY (KNS-METRE) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 2.3 44.0 0.9 2.1 124.8 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 7 7 3 3 7 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY (KNS-METRE) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS LRFD-H1-1B-C 0.605 7 |
| 2.31 C 2.15 124.77 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 68 of 159
Job No Sheet No Rev
1 69 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

289 TAP ERED (BS COLDFORMED SECTIONS

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 69 of 159
Job No Sheet No Rev
1 70 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Steel Design (Track 2) Beam 290 Check 1


|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CMS UNIT |
| * |=============================| ==| |== ------------ |
|MEMBER 290 * | BS COLDFORMED SECTIONS | | | AX=0.5990E+2 |
| * | TAP ERED | | | --Z AY=0.3150E+2 |
|DESIGN CODE * | | | | AZ=0.2000E+2 |
| LRFD 2001 * =============================== ==| |== PY=0.1173E+3 |
| * PZ=0.6507E+3 |
| * |<---LENGTH (M)= 1.16 --->| RY=0.3069E+1 |
|************* RZ=0.1558E+2 |
| |
| 75.1 (KNS-METRE) |
|PARAMETER |L7 CAPACITIES |
|IN KNS CMS | L7 IN KNS METRE |
|--------------- + L7 L7 -------------|
| KL/R-Y= 37.70 | L7 PNC=0.1175E+4|
| KL/R-Z= 7.43 + pnc=0.1725E+1|
| UNL = 115.70 | L7 L7 PNT=0.1338E+4|
| CB = 1.00 + pnt=0.0000E+0|
| PHIC = 0.85 | L7 MNZ=0.1910E+3|
| PHIB = 0.90 + L7 L7 mnz=0.7513E+2|
| FYLD = 24.82 | L7 MNY=0.2520E+2|
| NSF = 1.00 +---+---+---+---+---+---+---+---+---+---| mny=0.1222E+1|
| DFF = 58.11 35.3 VN =0.4223E+3|
| dff = 166.27 ABSOLUTE MZ ENVELOPE vn =0.3292E+2|
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY (KNS-METRE) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 1.7 32.9 0.7 1.2 75.1 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 7 7 3 3 7 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY (KNS-METRE) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS LRFD-H1-1B-C 0.442 7 |
| 1.73 C 1.22 75.13 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 70 of 159
Job No Sheet No Rev
1 71 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

290 TAP ERED (BS COLDFORMED SECTIONS

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 71 of 159
Job No Sheet No Rev
1 72 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Steel Design (Track 2) Beam 291 Check 1


|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CMS UNIT |
| * |=============================| ==| |== ------------ |
|MEMBER 291 * | BS COLDFORMED SECTIONS | | | AX=0.5417E+2 |
| * | TAP ERED | | | --Z AY=0.2577E+2 |
|DESIGN CODE * | | | | AZ=0.2000E+2 |
| LRFD 2001 * =============================== ==| |== PY=0.1162E+3 |
| * PZ=0.4699E+3 |
| * |<---LENGTH (M)= 1.14 --->| RY=0.3226E+1 |
|************* RZ=0.1300E+2 |
| |
| 37.4 (KNS-METRE) |
|PARAMETER |L7 CAPACITIES |
|IN KNS CMS | L7 IN KNS METRE |
|--------------- + L7 L7 -------------|
| KL/R-Y= 35.24 | L7 PNC=0.1072E+4|
| KL/R-Z= 8.75 + pnc=0.1147E+1|
| UNL = 113.70 | L7 L7 PNT=0.1210E+4|
| CB = 1.00 + pnt=0.0000E+0|
| PHIC = 0.85 | L7 MNZ=0.1454E+3|
| PHIB = 0.90 + L7 L7 mnz=0.3740E+2|
| FYLD = 24.82 | L7 MNY=0.2519E+2|
| NSF = 1.00 +---+---+---+---+---+---+---+---+---+---| mny=0.5471E+0|
| DFF = 58.11 11.5 VN =0.3454E+3|
| dff = 166.27 ABSOLUTE MZ ENVELOPE vn =0.2189E+2|
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY (KNS-METRE) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 1.1 21.9 0.5 0.5 37.4 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 7 7 3 3 7 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY (KNS-METRE) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS DEFLECTION 0.349 7 |
| 1.15 C 0.55 37.40 1.14 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 72 of 159
Job No Sheet No Rev
1 73 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

291 TAP ERED (BS COLDFORMED SECTIONS

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 73 of 159
Job No Sheet No Rev
1 74 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Steel Design (Track 2) Beam 292 Check 1


|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CMS UNIT |
| * |=============================| ==| |== ------------ |
|MEMBER 292 * | BS COLDFORMED SECTIONS | | | AX=0.4853E+2 |
| * | TAP ERED | | | --Z AY=0.2013E+2 |
|DESIGN CODE * | | | | AZ=0.2000E+2 |
| LRFD 2001 * =============================== ==| |== PY=0.1156E+3 |
| * PZ=0.3855E+3 |
| * |<---LENGTH (M)= 0.58 --->| RY=0.3407E+1 |
|************* RZ=0.1036E+2 |
| |
| 12.8 (KNS-METRE) |
|PARAMETER |L7 CAPACITIES |
|IN KNS CMS | L7 IN KNS METRE |
|--------------- + L7 L7 -------------|
| KL/R-Y= 16.98 | L7 PNC=0.1009E+4|
| KL/R-Z= 5.58 + pnc=0.5728E+0|
| UNL = 57.85 | L7 L7 PNT=0.1084E+4|
| CB = 1.00 + pnt=0.0000E+0|
| PHIC = 0.85 | L7 MNZ=0.1050E+3|
| PHIB = 0.90 + L7 L7 mnz=0.1282E+2|
| FYLD = 24.82 | L7 MNY=0.2518E+2|
| NSF = 1.00 +---+---+---+---+---+---+---+---+---+---| mny=0.1445E+0|
| DFF = 58.11 6.2 VN =0.2699E+3|
| dff = 166.27 ABSOLUTE MZ ENVELOPE vn =0.1093E+2|
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY (KNS-METRE) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 0.6 10.9 0.2 0.1 12.8 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 7 7 3 3 7 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY (KNS-METRE) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS DEFLECTION 0.349 7 |
| 0.57 C 0.14 12.82 0.58 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 74 of 159
Job No Sheet No Rev
1 75 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

292 TAP ERED (BS COLDFORMED SECTIONS

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 75 of 159
Job No Sheet No Rev
1 76 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Steel Design (Track 2) Beam 293 Check 1


|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CMS UNIT |
| * |=============================| ==| |== ------------ |
|MEMBER 293 * | BS COLDFORMED SECTIONS | | | AX=0.4567E+2 |
| * | TAP ERED | | | --Z AY=0.1727E+2 |
|DESIGN CODE * | | | | AZ=0.2000E+2 |
| LRFD 2001 * =============================== ==| |== PY=0.1151E+3 |
| * PZ=0.3062E+3 |
| * |<---LENGTH (M)= 0.62 --->| RY=0.3512E+1 |
|************* RZ=0.8978E+1 |
| |
| 6.6 (KNS-METRE) |
|PARAMETER |L7 CAPACITIES |
|IN KNS CMS | L7 IN KNS METRE |
|--------------- + L7 L7 -------------|
| KL/R-Y= 17.75 | L7 PNC=0.9480E+3|
| KL/R-Z= 6.94 + pnc=0.5191E+0|
| UNL = 62.34 | L7 L7 PNT=0.1020E+4|
| CB = 1.00 + pnt=0.0000E+0|
| PHIC = 0.85 | L7 MNZ=0.8611E+2|
| PHIB = 0.90 + L7 L7 mnz=0.6577E+1|
| FYLD = 24.82 | L0 MNY=0.2517E+2|
| NSF = 1.00 +---+---+---+---+---+---+---+---+---+---| mny=0.3887E-1|
| DFF = 58.11 -0.4 VN =0.2314E+3|
| dff = 166.27 ABSOLUTE MZ ENVELOPE vn =0.1068E+2|
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY (KNS-METRE) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 0.5 10.7 0.1 0.0 6.6 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 7 7 3 3 7 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY (KNS-METRE) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS DEFLECTION 0.349 7 |
| 0.52 C 0.04 6.58 0.62 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 76 of 159
Job No Sheet No Rev
1 77 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

293 TAP ERED (BS COLDFORMED SECTIONS

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 77 of 159
Job No Sheet No Rev
1 78 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Steel Design (Track 2) Beam 294 Check 1


|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CMS UNIT |
| * |=============================| ==| |== ------------ |
|MEMBER 294 * | BS COLDFORMED SECTIONS | | | AX=0.6554E+2 |
| * | TAP ERED | | | --Z AY=0.3714E+2 |
|DESIGN CODE * | | | | AZ=0.2000E+2 |
| LRFD 2001 * =============================== ==| |== PY=0.1185E+3 |
| * PZ=0.8552E+3 |
| * |<---LENGTH (M)= 1.14 --->| RY=0.2935E+1 |
|************* RZ=0.1804E+2 |
| |
| 77.8 (KNS-METRE) |
|PARAMETER |L3 CAPACITIES |
|IN KNS CMS | L3 IN KNS METRE |
|--------------- + L3 -------------|
| KL/R-Y= 38.75 | L3 PNC=0.1280E+4|
| KL/R-Z= 6.30 + pnc=0.1413E+1|
| UNL = 113.70 | L3 PNT=0.1464E+4|
| CB = 1.00 + pnt=0.0000E+0|
| PHIC = 0.85 | L3 MNZ=0.2404E+3|
| PHIB = 0.90 + L3 mnz=0.7776E+2|
| FYLD = 24.82 | L3 MNY=0.2522E+2|
| NSF = 1.00 +---+---+---+---+---+---+---+---+---+---| mny=0.2184E+1|
| DFF = 58.11 45.4 VN =0.4978E+3|
| dff = 166.27 ABSOLUTE MZ ENVELOPE vn =0.2696E+2|
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY (KNS-METRE) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 1.4 27.0 0.9 2.2 77.8 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 3 3 3 3 3 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY (KNS-METRE) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS LRFD-H1-1B-C 0.411 3 |
| 1.41 C -2.18 -77.76 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 78 of 159
Job No Sheet No Rev
1 79 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

294 TAP ERED (BS COLDFORMED SECTIONS

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 79 of 159
Job No Sheet No Rev
1 80 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Steel Design (Track 2) Beam 295 Check 1


|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CMS UNIT |
| * |=============================| ==| |== ------------ |
|MEMBER 295 * | BS COLDFORMED SECTIONS | | | AX=0.5990E+2 |
| * | TAP ERED | | | --Z AY=0.3150E+2 |
|DESIGN CODE * | | | | AZ=0.2000E+2 |
| LRFD 2001 * =============================== ==| |== PY=0.1173E+3 |
| * PZ=0.6507E+3 |
| * |<---LENGTH (M)= 1.16 --->| RY=0.3069E+1 |
|************* RZ=0.1558E+2 |
| |
| 47.1 (KNS-METRE) |
|PARAMETER |L3 CAPACITIES |
|IN KNS CMS | L3 IN KNS METRE |
|--------------- + L3 L3 -------------|
| KL/R-Y= 37.70 | L3 PNC=0.1175E+4|
| KL/R-Z= 7.43 + L3 pnc=0.0000E+0|
| UNL = 115.70 | L3 L3 PNT=0.1338E+4|
| CB = 1.00 + pnt=0.9370E+0|
| PHIC = 0.85 | L3 L3 MNZ=0.1910E+3|
| PHIB = 0.90 + L3 mnz=0.4054E+2|
| FYLD = 24.82 | L3 MNY=0.2520E+2|
| NSF = 1.00 +---+---+---+---+---+---+---+---+---+---| mny=0.1250E+1|
| DFF = 58.11 22.4 VN =0.4223E+3|
| dff = 166.27 ABSOLUTE MZ ENVELOPE vn =0.1788E+2|
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY (KNS-METRE) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 1.1 20.2 0.7 1.3 47.1 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 3 3 3 3 3 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY (KNS-METRE) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS DEFLECTION 0.349 7 |
| 0.94 T -1.25 40.54 1.16 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 80 of 159
Job No Sheet No Rev
1 81 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

295 TAP ERED (BS COLDFORMED SECTIONS

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 81 of 159
Job No Sheet No Rev
1 82 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Steel Design (Track 2) Beam 296 Check 1


|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CMS UNIT |
| * |=============================| ==| |== ------------ |
|MEMBER 296 * | BS COLDFORMED SECTIONS | | | AX=0.5417E+2 |
| * | TAP ERED | | | --Z AY=0.2577E+2 |
|DESIGN CODE * | | | | AZ=0.2000E+2 |
| LRFD 2001 * =============================== ==| |== PY=0.1162E+3 |
| * PZ=0.4699E+3 |
| * |<---LENGTH (M)= 1.14 --->| RY=0.3226E+1 |
|************* RZ=0.1300E+2 |
| |
| 23.7 (KNS-METRE) |
|PARAMETER |L3 CAPACITIES |
|IN KNS CMS | L3 IN KNS METRE |
|--------------- + L3 L3 -------------|
| KL/R-Y= 35.24 | L3 PNC=0.1072E+4|
| KL/R-Z= 8.75 + L3 pnc=0.0000E+0|
| UNL = 113.70 | L3 PNT=0.1210E+4|
| CB = 1.00 + pnt=0.6219E+0|
| PHIC = 0.85 | L3 MNZ=0.1454E+3|
| PHIB = 0.90 + L3 L3 mnz=0.2021E+2|
| FYLD = 24.82 | L3 MNY=0.2519E+2|
| NSF = 1.00 +---+---+---+---+---+---+---+---+---+---| mny=0.5659E+0|
| DFF = 58.11 7.5 VN =0.3454E+3|
| dff = 166.27 ABSOLUTE MZ ENVELOPE vn =0.1187E+2|
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY (KNS-METRE) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 0.7 13.5 0.5 0.6 23.7 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 3 3 3 3 3 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY (KNS-METRE) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS DEFLECTION 0.349 7 |
| 0.62 T -0.57 20.21 1.14 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 82 of 159
Job No Sheet No Rev
1 83 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

296 TAP ERED (BS COLDFORMED SECTIONS

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 83 of 159
Job No Sheet No Rev
1 84 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Steel Design (Track 2) Beam 297 Check 1


|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CMS UNIT |
| * |=============================| ==| |== ------------ |
|MEMBER 297 * | BS COLDFORMED SECTIONS | | | AX=0.4853E+2 |
| * | TAP ERED | | | --Z AY=0.2013E+2 |
|DESIGN CODE * | | | | AZ=0.2000E+2 |
| LRFD 2001 * =============================== ==| |== PY=0.1156E+3 |
| * PZ=0.3855E+3 |
| * |<---LENGTH (M)= 0.58 --->| RY=0.3407E+1 |
|************* RZ=0.1036E+2 |
| |
| 8.4 (KNS-METRE) |
|PARAMETER |L3 CAPACITIES |
|IN KNS CMS | L3 IN KNS METRE |
|--------------- + L3 L3 -------------|
| KL/R-Y= 16.98 | L3 PNC=0.1009E+4|
| KL/R-Z= 5.58 + L3 pnc=0.0000E+0|
| UNL = 57.85 | L3 PNT=0.1084E+4|
| CB = 1.00 + pnt=0.3105E+0|
| PHIC = 0.85 | L3 L3 MNZ=0.1050E+3|
| PHIB = 0.90 + L3 mnz=0.7029E+1|
| FYLD = 24.82 | L3 MNY=0.2518E+2|
| NSF = 1.00 +---+---+---+---+---+---+---+---+---+---| mny=0.1542E+0|
| DFF = 58.11 4.3 VN =0.2699E+3|
| dff = 166.27 ABSOLUTE MZ ENVELOPE vn =0.5926E+1|
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY (KNS-METRE) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 0.4 6.7 0.2 0.2 8.4 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 3 3 3 3 3 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY (KNS-METRE) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS DEFLECTION 0.349 7 |
| 0.31 T -0.15 7.03 0.58 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 84 of 159
Job No Sheet No Rev
1 85 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

297 TAP ERED (BS COLDFORMED SECTIONS

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 85 of 159
Job No Sheet No Rev
1 86 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Steel Design (Track 2) Beam 298 Check 1


|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CMS UNIT |
| * |=============================| ==| |== ------------ |
|MEMBER 298 * | BS COLDFORMED SECTIONS | | | AX=0.4567E+2 |
| * | TAP ERED | | | --Z AY=0.1727E+2 |
|DESIGN CODE * | | | | AZ=0.2000E+2 |
| LRFD 2001 * =============================== ==| |== PY=0.1151E+3 |
| * PZ=0.3062E+3 |
| * |<---LENGTH (M)= 0.66 --->| RY=0.3512E+1 |
|************* RZ=0.8978E+1 |
| |
| 4.5 (KNS-METRE) |
|PARAMETER |L3 CAPACITIES |
|IN KNS CMS | L3 IN KNS METRE |
|--------------- + L3 L3 -------------|
| KL/R-Y= 18.89 | L3 PNC=0.9460E+3|
| KL/R-Z= 7.39 + L3 pnc=0.0000E+0|
| UNL = 66.34 | L3 PNT=0.1020E+4|
| CB = 1.00 + pnt=0.2593E+0|
| PHIC = 0.85 | L3 L3 MNZ=0.8611E+2|
| PHIB = 0.90 + L3 mnz=0.3675E+1|
| FYLD = 24.82 | L0 MNY=0.2517E+2|
| NSF = 1.00 +---+---+---+---+---+---+---+---+---+---| mny=0.4401E-1|
| DFF = 58.11 -0.2 VN =0.2314E+3|
| dff = 166.27 ABSOLUTE MZ ENVELOPE vn =0.5676E+1|
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY (KNS-METRE) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 0.3 6.7 0.1 0.0 4.5 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 3 3 3 3 3 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY (KNS-METRE) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS DEFLECTION 0.349 7 |
| 0.26 T -0.04 3.67 0.66 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 86 of 159
Job No Sheet No Rev
1 87 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

298 TAP ERED (BS COLDFORMED SECTIONS

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 87 of 159
Job No Sheet No Rev
1 88 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Steel Design (Track 2) Beam 299 Check 1


|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CMS UNIT |
| * |=============================| ==| |== ------------ |
|MEMBER 299 * | BS COLDFORMED SECTIONS | | | AX=0.6840E+2 |
| * | TAP ERED | | | --Z AY=0.4000E+2 |
|DESIGN CODE * | | | | AZ=0.2000E+2 |
| LRFD 2001 * =============================== ==| |== PY=0.1196E+3 |
| * PZ=0.1076E+4 |
| * |<---LENGTH (M)= 0.58 --->| RY=0.2873E+1 |
|************* RZ=0.1926E+2 |
| |
| 156.3 (KNS-METRE) |
|PARAMETER |L7 CAPACITIES |
|IN KNS CMS | L7 IN KNS METRE |
|--------------- + L7 L7 -------------|
| KL/R-Y= 20.08 | L7 PNC=0.1414E+4|
| KL/R-Z= 3.00 + pnc=0.2871E+1|
| UNL = 57.70 | L7 L7 PNT=0.1528E+4|
| CB = 1.00 + pnt=0.0000E+0|
| PHIC = 0.85 | L7 MNZ=0.2671E+3|
| PHIB = 0.90 + L7 L7 mnz=0.1563E+3|
| FYLD = 24.82 | L7 MNY=0.2522E+2|
| NSF = 1.00 +---+---+---+---+---+---+---+---+---+---| mny=0.2714E+1|
| DFF = 58.11 123.0 VN =0.5361E+3|
| dff = 166.27 ABSOLUTE MZ ENVELOPE vn =0.5478E+2|
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY (KNS-METRE) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 2.9 54.8 1.1 2.7 156.3 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 7 7 5 3 7 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY (KNS-METRE) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS LRFD-H1-1B-C 0.694 7 |
| 2.87 C 2.71 156.28 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 88 of 159
Job No Sheet No Rev
1 89 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

299 TAP ERED (BS COLDFORMED SECTIONS

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 89 of 159
Job No Sheet No Rev
1 90 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Steel Design (Track 2) Beam 300 Check 1


|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CMS UNIT |
| * |=============================| ==| |== ------------ |
|MEMBER 300 * | BS COLDFORMED SECTIONS | | | AX=0.6840E+2 |
| * | TAP ERED | | | --Z AY=0.4000E+2 |
|DESIGN CODE * | | | | AZ=0.2000E+2 |
| LRFD 2001 * =============================== ==| |== PY=0.1196E+3 |
| * PZ=0.1076E+4 |
| * |<---LENGTH (M)= 0.58 --->| RY=0.2873E+1 |
|************* RZ=0.1926E+2 |
| |
| 97.2 (KNS-METRE) |
|PARAMETER |L3 CAPACITIES |
|IN KNS CMS | L3 L3 IN KNS METRE |
|--------------- + L3 -------------|
| KL/R-Y= 20.08 | L3 PNC=0.1414E+4|
| KL/R-Z= 3.00 + pnc=0.1766E+1|
| UNL = 57.70 | L3 L3 PNT=0.1528E+4|
| CB = 1.00 + pnt=0.0000E+0|
| PHIC = 0.85 | L3 L3 MNZ=0.2671E+3|
| PHIB = 0.90 + L3 mnz=0.9720E+2|
| FYLD = 24.82 | L3 MNY=0.2522E+2|
| NSF = 1.00 +---+---+---+---+---+---+---+---+---+---| mny=0.2756E+1|
| DFF = 58.11 76.7 VN =0.5361E+3|
| dff = 166.27 ABSOLUTE MZ ENVELOPE vn =0.3370E+2|
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY (KNS-METRE) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 1.8 33.7 1.1 2.8 97.2 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 3 3 5 3 3 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY (KNS-METRE) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS LRFD-H1-1B-C 0.474 3 |
| 1.77 C -2.76 -97.20 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 90 of 159
Job No Sheet No Rev
1 91 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

300 TAP ERED (BS COLDFORMED SECTIONS

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 91 of 159
Job No Sheet No Rev
1 92 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Steel Design (Track 2) Beam 301 Check 1


|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CMS UNIT |
| * |=============================| ==| |== ------------ |
|MEMBER 301 * | BS COLDFORMED SECTIONS | | | AX=0.6554E+2 |
| * | TAP ERED | | | --Z AY=0.3714E+2 |
|DESIGN CODE * | | | | AZ=0.2000E+2 |
| LRFD 2001 * =============================== ==| |== PY=0.1185E+3 |
| * PZ=0.8552E+3 |
| * |<---LENGTH (M)= 1.14 --->| RY=0.2935E+1 |
|************* RZ=0.1804E+2 |
| |
| 124.8 (KNS-METRE) |
|PARAMETER |L7 CAPACITIES |
|IN KNS CMS | L7 IN KNS METRE |
|--------------- + L7 L7 -------------|
| KL/R-Y= 38.75 | L7 PNC=0.1280E+4|
| KL/R-Z= 6.30 + pnc=0.2306E+1|
| UNL = 113.70 | L7 L7 PNT=0.1464E+4|
| CB = 1.00 + pnt=0.0000E+0|
| PHIC = 0.85 | L7 MNZ=0.2404E+3|
| PHIB = 0.90 + L7 L7 mnz=0.1248E+3|
| FYLD = 24.82 | L7 MNY=0.2522E+2|
| NSF = 1.00 +---+---+---+---+---+---+---+---+---+---| mny=0.2146E+1|
| DFF = 58.11 72.4 VN =0.4978E+3|
| dff = 166.27 ABSOLUTE MZ ENVELOPE vn =0.4400E+2|
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY (KNS-METRE) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 2.3 44.0 0.9 2.1 124.8 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 7 7 3 3 7 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY (KNS-METRE) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS LRFD-H1-1B-C 0.605 7 |
| 2.31 C 2.15 124.77 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 92 of 159
Job No Sheet No Rev
1 93 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

301 TAP ERED (BS COLDFORMED SECTIONS

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 93 of 159
Job No Sheet No Rev
1 94 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Steel Design (Track 2) Beam 302 Check 1


|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CMS UNIT |
| * |=============================| ==| |== ------------ |
|MEMBER 302 * | BS COLDFORMED SECTIONS | | | AX=0.5990E+2 |
| * | TAP ERED | | | --Z AY=0.3150E+2 |
|DESIGN CODE * | | | | AZ=0.2000E+2 |
| LRFD 2001 * =============================== ==| |== PY=0.1173E+3 |
| * PZ=0.6507E+3 |
| * |<---LENGTH (M)= 1.16 --->| RY=0.3069E+1 |
|************* RZ=0.1558E+2 |
| |
| 75.1 (KNS-METRE) |
|PARAMETER |L7 CAPACITIES |
|IN KNS CMS | L7 IN KNS METRE |
|--------------- + L7 L7 -------------|
| KL/R-Y= 37.70 | L7 PNC=0.1175E+4|
| KL/R-Z= 7.43 + pnc=0.1725E+1|
| UNL = 115.70 | L7 L7 PNT=0.1338E+4|
| CB = 1.00 + pnt=0.0000E+0|
| PHIC = 0.85 | L7 MNZ=0.1910E+3|
| PHIB = 0.90 + L7 L7 mnz=0.7513E+2|
| FYLD = 24.82 | L7 MNY=0.2520E+2|
| NSF = 1.00 +---+---+---+---+---+---+---+---+---+---| mny=0.1222E+1|
| DFF = 58.11 35.3 VN =0.4223E+3|
| dff = 166.27 ABSOLUTE MZ ENVELOPE vn =0.3292E+2|
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY (KNS-METRE) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 1.7 32.9 0.7 1.2 75.1 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 7 7 3 3 7 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY (KNS-METRE) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS LRFD-H1-1B-C 0.442 7 |
| 1.73 C 1.22 75.13 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 94 of 159
Job No Sheet No Rev
1 95 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

302 TAP ERED (BS COLDFORMED SECTIONS

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 95 of 159
Job No Sheet No Rev
1 96 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Steel Design (Track 2) Beam 303 Check 1


|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CMS UNIT |
| * |=============================| ==| |== ------------ |
|MEMBER 303 * | BS COLDFORMED SECTIONS | | | AX=0.5417E+2 |
| * | TAP ERED | | | --Z AY=0.2577E+2 |
|DESIGN CODE * | | | | AZ=0.2000E+2 |
| LRFD 2001 * =============================== ==| |== PY=0.1162E+3 |
| * PZ=0.4699E+3 |
| * |<---LENGTH (M)= 1.14 --->| RY=0.3226E+1 |
|************* RZ=0.1300E+2 |
| |
| 37.4 (KNS-METRE) |
|PARAMETER |L7 CAPACITIES |
|IN KNS CMS | L7 IN KNS METRE |
|--------------- + L7 L7 -------------|
| KL/R-Y= 35.24 | L7 PNC=0.1072E+4|
| KL/R-Z= 8.75 + pnc=0.1147E+1|
| UNL = 113.70 | L7 L7 PNT=0.1210E+4|
| CB = 1.00 + pnt=0.0000E+0|
| PHIC = 0.85 | L7 MNZ=0.1454E+3|
| PHIB = 0.90 + L7 L7 mnz=0.3740E+2|
| FYLD = 24.82 | L7 MNY=0.2519E+2|
| NSF = 1.00 +---+---+---+---+---+---+---+---+---+---| mny=0.5471E+0|
| DFF = 58.11 11.5 VN =0.3454E+3|
| dff = 166.27 ABSOLUTE MZ ENVELOPE vn =0.2189E+2|
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY (KNS-METRE) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 1.1 21.9 0.5 0.5 37.4 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 7 7 3 3 7 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY (KNS-METRE) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS DEFLECTION 0.349 7 |
| 1.15 C 0.55 37.40 1.14 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 96 of 159
Job No Sheet No Rev
1 97 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

303 TAP ERED (BS COLDFORMED SECTIONS

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 97 of 159
Job No Sheet No Rev
1 98 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Steel Design (Track 2) Beam 304 Check 1


|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CMS UNIT |
| * |=============================| ==| |== ------------ |
|MEMBER 304 * | BS COLDFORMED SECTIONS | | | AX=0.4853E+2 |
| * | TAP ERED | | | --Z AY=0.2013E+2 |
|DESIGN CODE * | | | | AZ=0.2000E+2 |
| LRFD 2001 * =============================== ==| |== PY=0.1156E+3 |
| * PZ=0.3855E+3 |
| * |<---LENGTH (M)= 0.58 --->| RY=0.3407E+1 |
|************* RZ=0.1036E+2 |
| |
| 12.8 (KNS-METRE) |
|PARAMETER |L7 CAPACITIES |
|IN KNS CMS | L7 IN KNS METRE |
|--------------- + L7 L7 -------------|
| KL/R-Y= 16.98 | L7 PNC=0.1009E+4|
| KL/R-Z= 5.58 + pnc=0.5728E+0|
| UNL = 57.85 | L7 L7 PNT=0.1084E+4|
| CB = 1.00 + pnt=0.0000E+0|
| PHIC = 0.85 | L7 MNZ=0.1050E+3|
| PHIB = 0.90 + L7 L7 mnz=0.1282E+2|
| FYLD = 24.82 | L7 MNY=0.2518E+2|
| NSF = 1.00 +---+---+---+---+---+---+---+---+---+---| mny=0.1445E+0|
| DFF = 58.11 6.2 VN =0.2699E+3|
| dff = 166.27 ABSOLUTE MZ ENVELOPE vn =0.1093E+2|
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY (KNS-METRE) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 0.6 10.9 0.2 0.1 12.8 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 7 7 3 3 7 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY (KNS-METRE) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS DEFLECTION 0.349 7 |
| 0.57 C 0.14 12.82 0.58 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 98 of 159
Job No Sheet No Rev
1 99 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

304 TAP ERED (BS COLDFORMED SECTIONS

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 99 of 159
Job No Sheet No Rev
1 100 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Steel Design (Track 2) Beam 305 Check 1


|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CMS UNIT |
| * |=============================| ==| |== ------------ |
|MEMBER 305 * | BS COLDFORMED SECTIONS | | | AX=0.4567E+2 |
| * | TAP ERED | | | --Z AY=0.1727E+2 |
|DESIGN CODE * | | | | AZ=0.2000E+2 |
| LRFD 2001 * =============================== ==| |== PY=0.1151E+3 |
| * PZ=0.3062E+3 |
| * |<---LENGTH (M)= 0.62 --->| RY=0.3512E+1 |
|************* RZ=0.8978E+1 |
| |
| 6.6 (KNS-METRE) |
|PARAMETER |L7 CAPACITIES |
|IN KNS CMS | L7 IN KNS METRE |
|--------------- + L7 L7 -------------|
| KL/R-Y= 17.75 | L7 PNC=0.9480E+3|
| KL/R-Z= 6.94 + pnc=0.5191E+0|
| UNL = 62.34 | L7 L7 PNT=0.1020E+4|
| CB = 1.00 + pnt=0.0000E+0|
| PHIC = 0.85 | L7 MNZ=0.8611E+2|
| PHIB = 0.90 + L7 L7 mnz=0.6577E+1|
| FYLD = 24.82 | L0 MNY=0.2517E+2|
| NSF = 1.00 +---+---+---+---+---+---+---+---+---+---| mny=0.3887E-1|
| DFF = 58.11 -0.4 VN =0.2314E+3|
| dff = 166.27 ABSOLUTE MZ ENVELOPE vn =0.1068E+2|
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY (KNS-METRE) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 0.5 10.7 0.1 0.0 6.6 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 7 7 3 3 7 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY (KNS-METRE) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS DEFLECTION 0.349 7 |
| 0.52 C 0.04 6.58 0.62 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 100 of 159
Job No Sheet No Rev
1 101 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

305 TAP ERED (BS COLDFORMED SECTIONS

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 101 of 159
Job No Sheet No Rev
1 102 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Steel Design (Track 2) Beam 306 Check 1


|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CMS UNIT |
| * |=============================| ==| |== ------------ |
|MEMBER 306 * | BS COLDFORMED SECTIONS | | | AX=0.6554E+2 |
| * | TAP ERED | | | --Z AY=0.3714E+2 |
|DESIGN CODE * | | | | AZ=0.2000E+2 |
| LRFD 2001 * =============================== ==| |== PY=0.1185E+3 |
| * PZ=0.8552E+3 |
| * |<---LENGTH (M)= 1.14 --->| RY=0.2935E+1 |
|************* RZ=0.1804E+2 |
| |
| 77.8 (KNS-METRE) |
|PARAMETER |L3 CAPACITIES |
|IN KNS CMS | L3 L3 IN KNS METRE |
|--------------- + L3 -------------|
| KL/R-Y= 38.75 | L3 PNC=0.1280E+4|
| KL/R-Z= 6.30 + pnc=0.1413E+1|
| UNL = 113.70 | L3 L3 PNT=0.1464E+4|
| CB = 1.00 + pnt=0.0000E+0|
| PHIC = 0.85 | L3 MNZ=0.2404E+3|
| PHIB = 0.90 + L3 mnz=0.7776E+2|
| FYLD = 24.82 | L3 MNY=0.2522E+2|
| NSF = 1.00 +---+---+---+---+---+---+---+---+---+---| mny=0.2184E+1|
| DFF = 58.11 45.4 VN =0.4978E+3|
| dff = 166.27 ABSOLUTE MZ ENVELOPE vn =0.2696E+2|
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY (KNS-METRE) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 1.4 27.0 0.9 2.2 77.8 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 3 3 3 3 3 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY (KNS-METRE) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS LRFD-H1-1B-C 0.411 3 |
| 1.41 C -2.18 -77.76 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 102 of 159
Job No Sheet No Rev
1 103 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

306 TAP ERED (BS COLDFORMED SECTIONS

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 103 of 159
Job No Sheet No Rev
1 104 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Steel Design (Track 2) Beam 307 Check 1


|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CMS UNIT |
| * |=============================| ==| |== ------------ |
|MEMBER 307 * | BS COLDFORMED SECTIONS | | | AX=0.5990E+2 |
| * | TAP ERED | | | --Z AY=0.3150E+2 |
|DESIGN CODE * | | | | AZ=0.2000E+2 |
| LRFD 2001 * =============================== ==| |== PY=0.1173E+3 |
| * PZ=0.6507E+3 |
| * |<---LENGTH (M)= 1.16 --->| RY=0.3069E+1 |
|************* RZ=0.1558E+2 |
| |
| 47.1 (KNS-METRE) |
|PARAMETER |L3 CAPACITIES |
|IN KNS CMS | L3 IN KNS METRE |
|--------------- + L3 -------------|
| KL/R-Y= 37.70 | L3 PNC=0.1175E+4|
| KL/R-Z= 7.43 + L3 pnc=0.0000E+0|
| UNL = 115.70 | L3 PNT=0.1338E+4|
| CB = 1.00 + pnt=0.9370E+0|
| PHIC = 0.85 | L3 L3 MNZ=0.1910E+3|
| PHIB = 0.90 + L3 mnz=0.4054E+2|
| FYLD = 24.82 | L3 MNY=0.2520E+2|
| NSF = 1.00 +---+---+---+---+---+---+---+---+---+---| mny=0.1250E+1|
| DFF = 58.11 22.4 VN =0.4223E+3|
| dff = 166.27 ABSOLUTE MZ ENVELOPE vn =0.1788E+2|
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY (KNS-METRE) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 1.1 20.2 0.7 1.3 47.1 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 3 3 3 3 3 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY (KNS-METRE) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS DEFLECTION 0.349 7 |
| 0.94 T -1.25 40.54 1.16 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 104 of 159
Job No Sheet No Rev
1 105 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

307 TAP ERED (BS COLDFORMED SECTIONS

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 105 of 159
Job No Sheet No Rev
1 106 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Steel Design (Track 2) Beam 308 Check 1


|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CMS UNIT |
| * |=============================| ==| |== ------------ |
|MEMBER 308 * | BS COLDFORMED SECTIONS | | | AX=0.5417E+2 |
| * | TAP ERED | | | --Z AY=0.2577E+2 |
|DESIGN CODE * | | | | AZ=0.2000E+2 |
| LRFD 2001 * =============================== ==| |== PY=0.1162E+3 |
| * PZ=0.4699E+3 |
| * |<---LENGTH (M)= 1.14 --->| RY=0.3226E+1 |
|************* RZ=0.1300E+2 |
| |
| 23.7 (KNS-METRE) |
|PARAMETER |L3 CAPACITIES |
|IN KNS CMS | L3 IN KNS METRE |
|--------------- + L3 L3 -------------|
| KL/R-Y= 35.24 | L3 PNC=0.1072E+4|
| KL/R-Z= 8.75 + pnc=0.0000E+0|
| UNL = 113.70 | L3 L3 PNT=0.1210E+4|
| CB = 1.00 + pnt=0.6219E+0|
| PHIC = 0.85 | L3 MNZ=0.1454E+3|
| PHIB = 0.90 + L3 L3 mnz=0.2021E+2|
| FYLD = 24.82 | L3 MNY=0.2519E+2|
| NSF = 1.00 +---+---+---+---+---+---+---+---+---+---| mny=0.5659E+0|
| DFF = 58.11 7.5 VN =0.3454E+3|
| dff = 166.27 ABSOLUTE MZ ENVELOPE vn =0.1187E+2|
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY (KNS-METRE) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 0.7 13.5 0.5 0.6 23.7 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 3 3 3 3 3 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY (KNS-METRE) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS DEFLECTION 0.349 7 |
| 0.62 T -0.57 20.21 1.14 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 106 of 159
Job No Sheet No Rev
1 107 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

308 TAP ERED (BS COLDFORMED SECTIONS

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 107 of 159
Job No Sheet No Rev
1 108 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Steel Design (Track 2) Beam 309 Check 1


|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CMS UNIT |
| * |=============================| ==| |== ------------ |
|MEMBER 309 * | BS COLDFORMED SECTIONS | | | AX=0.4853E+2 |
| * | TAP ERED | | | --Z AY=0.2013E+2 |
|DESIGN CODE * | | | | AZ=0.2000E+2 |
| LRFD 2001 * =============================== ==| |== PY=0.1156E+3 |
| * PZ=0.3855E+3 |
| * |<---LENGTH (M)= 0.58 --->| RY=0.3407E+1 |
|************* RZ=0.1036E+2 |
| |
| 8.4 (KNS-METRE) |
|PARAMETER |L3 CAPACITIES |
|IN KNS CMS | L3 IN KNS METRE |
|--------------- + L3 L3 -------------|
| KL/R-Y= 16.98 | L3 PNC=0.1009E+4|
| KL/R-Z= 5.58 + pnc=0.0000E+0|
| UNL = 57.85 | L3 L3 PNT=0.1084E+4|
| CB = 1.00 + pnt=0.3105E+0|
| PHIC = 0.85 | L3 MNZ=0.1050E+3|
| PHIB = 0.90 + L3 mnz=0.7029E+1|
| FYLD = 24.82 | L3 MNY=0.2518E+2|
| NSF = 1.00 +---+---+---+---+---+---+---+---+---+---| mny=0.1542E+0|
| DFF = 58.11 4.3 VN =0.2699E+3|
| dff = 166.27 ABSOLUTE MZ ENVELOPE vn =0.5926E+1|
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY (KNS-METRE) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 0.4 6.7 0.2 0.2 8.4 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 3 3 3 3 3 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY (KNS-METRE) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS DEFLECTION 0.349 7 |
| 0.31 T -0.15 7.03 0.58 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 108 of 159
Job No Sheet No Rev
1 109 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

309 TAP ERED (BS COLDFORMED SECTIONS

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 109 of 159
Job No Sheet No Rev
1 110 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Steel Design (Track 2) Beam 310 Check 1


|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CMS UNIT |
| * |=============================| ==| |== ------------ |
|MEMBER 310 * | BS COLDFORMED SECTIONS | | | AX=0.4567E+2 |
| * | TAP ERED | | | --Z AY=0.1727E+2 |
|DESIGN CODE * | | | | AZ=0.2000E+2 |
| LRFD 2001 * =============================== ==| |== PY=0.1151E+3 |
| * PZ=0.3062E+3 |
| * |<---LENGTH (M)= 0.66 --->| RY=0.3512E+1 |
|************* RZ=0.8978E+1 |
| |
| 4.5 (KNS-METRE) |
|PARAMETER |L3 CAPACITIES |
|IN KNS CMS | L3 IN KNS METRE |
|--------------- + L3 L3 -------------|
| KL/R-Y= 18.89 | L3 PNC=0.9460E+3|
| KL/R-Z= 7.39 + L3 pnc=0.0000E+0|
| UNL = 66.34 | L3 PNT=0.1020E+4|
| CB = 1.00 + pnt=0.2593E+0|
| PHIC = 0.85 | L3 L3 MNZ=0.8611E+2|
| PHIB = 0.90 + L3 mnz=0.3675E+1|
| FYLD = 24.82 | L0 MNY=0.2517E+2|
| NSF = 1.00 +---+---+---+---+---+---+---+---+---+---| mny=0.4401E-1|
| DFF = 58.11 -0.2 VN =0.2314E+3|
| dff = 166.27 ABSOLUTE MZ ENVELOPE vn =0.5676E+1|
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY (KNS-METRE) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 0.3 6.7 0.1 0.0 4.5 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 3 3 3 3 3 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY (KNS-METRE) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS DEFLECTION 0.349 7 |
| 0.26 T -0.04 3.67 0.66 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 110 of 159
Job No Sheet No Rev
1 111 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

310 TAP ERED (BS COLDFORMED SECTIONS

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 111 of 159
Job No Sheet No Rev
1 112 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Steel Design (Track 2) Beam 311 Check 1


|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CMS UNIT |
| * |=============================| ==| |== ------------ |
|MEMBER 311 * | BS COLDFORMED SECTIONS | | | AX=0.6840E+2 |
| * | TAP ERED | | | --Z AY=0.4000E+2 |
|DESIGN CODE * | | | | AZ=0.2000E+2 |
| LRFD 2001 * =============================== ==| |== PY=0.1196E+3 |
| * PZ=0.1076E+4 |
| * |<---LENGTH (M)= 0.58 --->| RY=0.2873E+1 |
|************* RZ=0.1926E+2 |
| |
| 156.3 (KNS-METRE) |
|PARAMETER |L7 CAPACITIES |
|IN KNS CMS | L7 IN KNS METRE |
|--------------- + L7 L7 -------------|
| KL/R-Y= 20.08 | L7 PNC=0.1414E+4|
| KL/R-Z= 3.00 + pnc=0.2871E+1|
| UNL = 57.70 | L7 L7 PNT=0.1528E+4|
| CB = 1.00 + pnt=0.0000E+0|
| PHIC = 0.85 | L7 MNZ=0.2671E+3|
| PHIB = 0.90 + L7 L7 mnz=0.1563E+3|
| FYLD = 24.82 | L7 MNY=0.2522E+2|
| NSF = 1.00 +---+---+---+---+---+---+---+---+---+---| mny=0.2714E+1|
| DFF = 58.11 123.0 VN =0.5361E+3|
| dff = 166.27 ABSOLUTE MZ ENVELOPE vn =0.5478E+2|
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY (KNS-METRE) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 2.9 54.8 1.1 2.7 156.3 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 7 7 5 3 7 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY (KNS-METRE) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS LRFD-H1-1B-C 0.694 7 |
| 2.87 C 2.71 156.28 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 112 of 159
Job No Sheet No Rev
1 113 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

311 TAP ERED (BS COLDFORMED SECTIONS

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 113 of 159
Job No Sheet No Rev
1 114 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Steel Design (Track 2) Beam 312 Check 1


|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CMS UNIT |
| * |=============================| ==| |== ------------ |
|MEMBER 312 * | BS COLDFORMED SECTIONS | | | AX=0.6840E+2 |
| * | TAP ERED | | | --Z AY=0.4000E+2 |
|DESIGN CODE * | | | | AZ=0.2000E+2 |
| LRFD 2001 * =============================== ==| |== PY=0.1196E+3 |
| * PZ=0.1076E+4 |
| * |<---LENGTH (M)= 0.58 --->| RY=0.2873E+1 |
|************* RZ=0.1926E+2 |
| |
| 97.2 (KNS-METRE) |
|PARAMETER |L3 CAPACITIES |
|IN KNS CMS | L3 IN KNS METRE |
|--------------- + L3 L3 -------------|
| KL/R-Y= 20.08 | L3 PNC=0.1414E+4|
| KL/R-Z= 3.00 + pnc=0.1766E+1|
| UNL = 57.70 | L3 L3 PNT=0.1528E+4|
| CB = 1.00 + pnt=0.0000E+0|
| PHIC = 0.85 | L3 MNZ=0.2671E+3|
| PHIB = 0.90 + L3 mnz=0.9720E+2|
| FYLD = 24.82 | L3 MNY=0.2522E+2|
| NSF = 1.00 +---+---+---+---+---+---+---+---+---+---| mny=0.2756E+1|
| DFF = 58.11 76.7 VN =0.5361E+3|
| dff = 166.27 ABSOLUTE MZ ENVELOPE vn =0.3370E+2|
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY (KNS-METRE) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 1.8 33.7 1.1 2.8 97.2 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 3 3 5 3 3 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY (KNS-METRE) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS LRFD-H1-1B-C 0.474 3 |
| 1.77 C -2.76 -97.20 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 114 of 159
Job No Sheet No Rev
1 115 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

312 TAP ERED (BS COLDFORMED SECTIONS

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 115 of 159
Job No Sheet No Rev
1 116 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Steel Design (Track 2) Beam 313 Check 1


|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CMS UNIT |
| * |=============================| ==| |== ------------ |
|MEMBER 313 * | BS COLDFORMED SECTIONS | | | AX=0.6554E+2 |
| * | TAP ERED | | | --Z AY=0.3714E+2 |
|DESIGN CODE * | | | | AZ=0.2000E+2 |
| LRFD 2001 * =============================== ==| |== PY=0.1185E+3 |
| * PZ=0.8552E+3 |
| * |<---LENGTH (M)= 1.14 --->| RY=0.2935E+1 |
|************* RZ=0.1804E+2 |
| |
| 124.8 (KNS-METRE) |
|PARAMETER |L7 CAPACITIES |
|IN KNS CMS | L7 IN KNS METRE |
|--------------- + L7 L7 -------------|
| KL/R-Y= 38.75 | L7 PNC=0.1280E+4|
| KL/R-Z= 6.30 + pnc=0.2306E+1|
| UNL = 113.70 | L7 L7 PNT=0.1464E+4|
| CB = 1.00 + pnt=0.0000E+0|
| PHIC = 0.85 | L7 MNZ=0.2404E+3|
| PHIB = 0.90 + L7 L7 mnz=0.1248E+3|
| FYLD = 24.82 | L7 MNY=0.2522E+2|
| NSF = 1.00 +---+---+---+---+---+---+---+---+---+---| mny=0.2146E+1|
| DFF = 58.11 72.4 VN =0.4978E+3|
| dff = 166.27 ABSOLUTE MZ ENVELOPE vn =0.4400E+2|
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY (KNS-METRE) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 2.3 44.0 0.9 2.1 124.8 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 7 7 3 3 7 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY (KNS-METRE) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS LRFD-H1-1B-C 0.605 7 |
| 2.31 C 2.15 124.77 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 116 of 159
Job No Sheet No Rev
1 117 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

313 TAP ERED (BS COLDFORMED SECTIONS

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 117 of 159
Job No Sheet No Rev
1 118 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Steel Design (Track 2) Beam 314 Check 1


|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CMS UNIT |
| * |=============================| ==| |== ------------ |
|MEMBER 314 * | BS COLDFORMED SECTIONS | | | AX=0.5990E+2 |
| * | TAP ERED | | | --Z AY=0.3150E+2 |
|DESIGN CODE * | | | | AZ=0.2000E+2 |
| LRFD 2001 * =============================== ==| |== PY=0.1173E+3 |
| * PZ=0.6507E+3 |
| * |<---LENGTH (M)= 1.16 --->| RY=0.3069E+1 |
|************* RZ=0.1558E+2 |
| |
| 75.1 (KNS-METRE) |
|PARAMETER |L7 CAPACITIES |
|IN KNS CMS | L7 IN KNS METRE |
|--------------- + L7 L7 -------------|
| KL/R-Y= 37.70 | L7 PNC=0.1175E+4|
| KL/R-Z= 7.43 + pnc=0.1725E+1|
| UNL = 115.70 | L7 L7 PNT=0.1338E+4|
| CB = 1.00 + pnt=0.0000E+0|
| PHIC = 0.85 | L7 MNZ=0.1910E+3|
| PHIB = 0.90 + L7 L7 mnz=0.7513E+2|
| FYLD = 24.82 | L7 MNY=0.2520E+2|
| NSF = 1.00 +---+---+---+---+---+---+---+---+---+---| mny=0.1222E+1|
| DFF = 58.11 35.3 VN =0.4223E+3|
| dff = 166.27 ABSOLUTE MZ ENVELOPE vn =0.3292E+2|
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY (KNS-METRE) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 1.7 32.9 0.7 1.2 75.1 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 7 7 3 3 7 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY (KNS-METRE) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS LRFD-H1-1B-C 0.442 7 |
| 1.73 C 1.22 75.13 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 118 of 159
Job No Sheet No Rev
1 119 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

314 TAP ERED (BS COLDFORMED SECTIONS

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 119 of 159
Job No Sheet No Rev
1 120 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Steel Design (Track 2) Beam 315 Check 1


|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CMS UNIT |
| * |=============================| ==| |== ------------ |
|MEMBER 315 * | BS COLDFORMED SECTIONS | | | AX=0.5417E+2 |
| * | TAP ERED | | | --Z AY=0.2577E+2 |
|DESIGN CODE * | | | | AZ=0.2000E+2 |
| LRFD 2001 * =============================== ==| |== PY=0.1162E+3 |
| * PZ=0.4699E+3 |
| * |<---LENGTH (M)= 1.14 --->| RY=0.3226E+1 |
|************* RZ=0.1300E+2 |
| |
| 37.4 (KNS-METRE) |
|PARAMETER |L7 CAPACITIES |
|IN KNS CMS | L7 IN KNS METRE |
|--------------- + L7 L7 -------------|
| KL/R-Y= 35.24 | L7 PNC=0.1072E+4|
| KL/R-Z= 8.75 + pnc=0.1147E+1|
| UNL = 113.70 | L7 L7 PNT=0.1210E+4|
| CB = 1.00 + pnt=0.0000E+0|
| PHIC = 0.85 | L7 MNZ=0.1454E+3|
| PHIB = 0.90 + L7 L7 mnz=0.3740E+2|
| FYLD = 24.82 | L7 MNY=0.2519E+2|
| NSF = 1.00 +---+---+---+---+---+---+---+---+---+---| mny=0.5471E+0|
| DFF = 58.11 11.5 VN =0.3454E+3|
| dff = 166.27 ABSOLUTE MZ ENVELOPE vn =0.2189E+2|
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY (KNS-METRE) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 1.1 21.9 0.5 0.5 37.4 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 7 7 3 3 7 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY (KNS-METRE) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS DEFLECTION 0.349 7 |
| 1.15 C 0.55 37.40 1.14 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 120 of 159
Job No Sheet No Rev
1 121 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

315 TAP ERED (BS COLDFORMED SECTIONS

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 121 of 159
Job No Sheet No Rev
1 122 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Steel Design (Track 2) Beam 316 Check 1


|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CMS UNIT |
| * |=============================| ==| |== ------------ |
|MEMBER 316 * | BS COLDFORMED SECTIONS | | | AX=0.4853E+2 |
| * | TAP ERED | | | --Z AY=0.2013E+2 |
|DESIGN CODE * | | | | AZ=0.2000E+2 |
| LRFD 2001 * =============================== ==| |== PY=0.1156E+3 |
| * PZ=0.3855E+3 |
| * |<---LENGTH (M)= 0.58 --->| RY=0.3407E+1 |
|************* RZ=0.1036E+2 |
| |
| 12.8 (KNS-METRE) |
|PARAMETER |L7 CAPACITIES |
|IN KNS CMS | L7 IN KNS METRE |
|--------------- + L7 L7 -------------|
| KL/R-Y= 16.98 | L7 PNC=0.1009E+4|
| KL/R-Z= 5.58 + pnc=0.5728E+0|
| UNL = 57.85 | L7 L7 PNT=0.1084E+4|
| CB = 1.00 + pnt=0.0000E+0|
| PHIC = 0.85 | L7 MNZ=0.1050E+3|
| PHIB = 0.90 + L7 L7 mnz=0.1282E+2|
| FYLD = 24.82 | L7 MNY=0.2518E+2|
| NSF = 1.00 +---+---+---+---+---+---+---+---+---+---| mny=0.1445E+0|
| DFF = 58.11 6.2 VN =0.2699E+3|
| dff = 166.27 ABSOLUTE MZ ENVELOPE vn =0.1093E+2|
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY (KNS-METRE) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 0.6 10.9 0.2 0.1 12.8 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 7 7 3 3 7 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY (KNS-METRE) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS DEFLECTION 0.349 7 |
| 0.57 C 0.14 12.82 0.58 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 122 of 159
Job No Sheet No Rev
1 123 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

316 TAP ERED (BS COLDFORMED SECTIONS

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 123 of 159
Job No Sheet No Rev
1 124 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Steel Design (Track 2) Beam 317 Check 1


|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CMS UNIT |
| * |=============================| ==| |== ------------ |
|MEMBER 317 * | BS COLDFORMED SECTIONS | | | AX=0.4567E+2 |
| * | TAP ERED | | | --Z AY=0.1727E+2 |
|DESIGN CODE * | | | | AZ=0.2000E+2 |
| LRFD 2001 * =============================== ==| |== PY=0.1151E+3 |
| * PZ=0.3062E+3 |
| * |<---LENGTH (M)= 0.62 --->| RY=0.3512E+1 |
|************* RZ=0.8978E+1 |
| |
| 6.6 (KNS-METRE) |
|PARAMETER |L7 CAPACITIES |
|IN KNS CMS | L7 IN KNS METRE |
|--------------- + L7 L7 -------------|
| KL/R-Y= 17.75 | L7 PNC=0.9480E+3|
| KL/R-Z= 6.94 + pnc=0.5191E+0|
| UNL = 62.34 | L7 L7 PNT=0.1020E+4|
| CB = 1.00 + pnt=0.0000E+0|
| PHIC = 0.85 | L7 MNZ=0.8611E+2|
| PHIB = 0.90 + L7 L7 mnz=0.6577E+1|
| FYLD = 24.82 | L0 MNY=0.2517E+2|
| NSF = 1.00 +---+---+---+---+---+---+---+---+---+---| mny=0.3887E-1|
| DFF = 58.11 -0.4 VN =0.2314E+3|
| dff = 166.27 ABSOLUTE MZ ENVELOPE vn =0.1068E+2|
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY (KNS-METRE) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 0.5 10.7 0.1 0.0 6.6 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 7 7 3 3 7 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY (KNS-METRE) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS DEFLECTION 0.349 7 |
| 0.52 C 0.04 6.58 0.62 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 124 of 159
Job No Sheet No Rev
1 125 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

317 TAP ERED (BS COLDFORMED SECTIONS

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 125 of 159
Job No Sheet No Rev
1 126 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Steel Design (Track 2) Beam 318 Check 1


|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CMS UNIT |
| * |=============================| ==| |== ------------ |
|MEMBER 318 * | BS COLDFORMED SECTIONS | | | AX=0.6554E+2 |
| * | TAP ERED | | | --Z AY=0.3714E+2 |
|DESIGN CODE * | | | | AZ=0.2000E+2 |
| LRFD 2001 * =============================== ==| |== PY=0.1185E+3 |
| * PZ=0.8552E+3 |
| * |<---LENGTH (M)= 1.14 --->| RY=0.2935E+1 |
|************* RZ=0.1804E+2 |
| |
| 77.8 (KNS-METRE) |
|PARAMETER |L3 CAPACITIES |
|IN KNS CMS | L3 IN KNS METRE |
|--------------- + L3 -------------|
| KL/R-Y= 38.75 | L3 PNC=0.1280E+4|
| KL/R-Z= 6.30 + pnc=0.1413E+1|
| UNL = 113.70 | L3 PNT=0.1464E+4|
| CB = 1.00 + pnt=0.0000E+0|
| PHIC = 0.85 | L3 MNZ=0.2404E+3|
| PHIB = 0.90 + L3 L3 mnz=0.7776E+2|
| FYLD = 24.82 | L3 MNY=0.2522E+2|
| NSF = 1.00 +---+---+---+---+---+---+---+---+---+---| mny=0.2184E+1|
| DFF = 58.11 45.4 VN =0.4978E+3|
| dff = 166.27 ABSOLUTE MZ ENVELOPE vn =0.2696E+2|
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY (KNS-METRE) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 1.4 27.0 0.9 2.2 77.8 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 3 3 3 3 3 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY (KNS-METRE) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS LRFD-H1-1B-C 0.411 3 |
| 1.41 C -2.18 -77.76 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 126 of 159
Job No Sheet No Rev
1 127 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

318 TAP ERED (BS COLDFORMED SECTIONS

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 127 of 159
Job No Sheet No Rev
1 128 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Steel Design (Track 2) Beam 319 Check 1


|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CMS UNIT |
| * |=============================| ==| |== ------------ |
|MEMBER 319 * | BS COLDFORMED SECTIONS | | | AX=0.5990E+2 |
| * | TAP ERED | | | --Z AY=0.3150E+2 |
|DESIGN CODE * | | | | AZ=0.2000E+2 |
| LRFD 2001 * =============================== ==| |== PY=0.1173E+3 |
| * PZ=0.6507E+3 |
| * |<---LENGTH (M)= 1.16 --->| RY=0.3069E+1 |
|************* RZ=0.1558E+2 |
| |
| 47.1 (KNS-METRE) |
|PARAMETER |L3 CAPACITIES |
|IN KNS CMS | L3 L3 IN KNS METRE |
|--------------- + L3 -------------|
| KL/R-Y= 37.70 | L3 PNC=0.1175E+4|
| KL/R-Z= 7.43 + pnc=0.0000E+0|
| UNL = 115.70 | L3 L3 PNT=0.1338E+4|
| CB = 1.00 + pnt=0.9370E+0|
| PHIC = 0.85 | L3 L3 MNZ=0.1910E+3|
| PHIB = 0.90 + L3 L3 mnz=0.4054E+2|
| FYLD = 24.82 | L3 MNY=0.2520E+2|
| NSF = 1.00 +---+---+---+---+---+---+---+---+---+---| mny=0.1250E+1|
| DFF = 58.11 22.4 VN =0.4223E+3|
| dff = 166.27 ABSOLUTE MZ ENVELOPE vn =0.1788E+2|
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY (KNS-METRE) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 1.1 20.2 0.7 1.3 47.1 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 3 3 3 3 3 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY (KNS-METRE) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS DEFLECTION 0.349 7 |
| 0.94 T -1.25 40.54 1.16 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 128 of 159
Job No Sheet No Rev
1 129 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

319 TAP ERED (BS COLDFORMED SECTIONS

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 129 of 159
Job No Sheet No Rev
1 130 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Steel Design (Track 2) Beam 320 Check 1


|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CMS UNIT |
| * |=============================| ==| |== ------------ |
|MEMBER 320 * | BS COLDFORMED SECTIONS | | | AX=0.5417E+2 |
| * | TAP ERED | | | --Z AY=0.2577E+2 |
|DESIGN CODE * | | | | AZ=0.2000E+2 |
| LRFD 2001 * =============================== ==| |== PY=0.1162E+3 |
| * PZ=0.4699E+3 |
| * |<---LENGTH (M)= 1.14 --->| RY=0.3226E+1 |
|************* RZ=0.1300E+2 |
| |
| 23.7 (KNS-METRE) |
|PARAMETER |L3 CAPACITIES |
|IN KNS CMS | L3 IN KNS METRE |
|--------------- + L3 L3 -------------|
| KL/R-Y= 35.24 | L3 PNC=0.1072E+4|
| KL/R-Z= 8.75 + pnc=0.0000E+0|
| UNL = 113.70 | L3 L3 PNT=0.1210E+4|
| CB = 1.00 + pnt=0.6219E+0|
| PHIC = 0.85 | L3 L3 MNZ=0.1454E+3|
| PHIB = 0.90 + L3 L3 mnz=0.2021E+2|
| FYLD = 24.82 | L3 MNY=0.2519E+2|
| NSF = 1.00 +---+---+---+---+---+---+---+---+---+---| mny=0.5659E+0|
| DFF = 58.11 7.5 VN =0.3454E+3|
| dff = 166.27 ABSOLUTE MZ ENVELOPE vn =0.1187E+2|
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY (KNS-METRE) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 0.7 13.5 0.5 0.6 23.7 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 3 3 3 3 3 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY (KNS-METRE) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS DEFLECTION 0.349 7 |
| 0.62 T -0.57 20.21 1.14 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 130 of 159
Job No Sheet No Rev
1 131 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

320 TAP ERED (BS COLDFORMED SECTIONS

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 131 of 159
Job No Sheet No Rev
1 132 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Steel Design (Track 2) Beam 321 Check 1


|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CMS UNIT |
| * |=============================| ==| |== ------------ |
|MEMBER 321 * | BS COLDFORMED SECTIONS | | | AX=0.4853E+2 |
| * | TAP ERED | | | --Z AY=0.2013E+2 |
|DESIGN CODE * | | | | AZ=0.2000E+2 |
| LRFD 2001 * =============================== ==| |== PY=0.1156E+3 |
| * PZ=0.3855E+3 |
| * |<---LENGTH (M)= 0.58 --->| RY=0.3407E+1 |
|************* RZ=0.1036E+2 |
| |
| 8.4 (KNS-METRE) |
|PARAMETER |L3 CAPACITIES |
|IN KNS CMS | L3 IN KNS METRE |
|--------------- + L3 L3 -------------|
| KL/R-Y= 16.98 | L3 PNC=0.1009E+4|
| KL/R-Z= 5.58 + pnc=0.0000E+0|
| UNL = 57.85 | L3 L3 PNT=0.1084E+4|
| CB = 1.00 + pnt=0.3105E+0|
| PHIC = 0.85 | L3 L3 MNZ=0.1050E+3|
| PHIB = 0.90 + L3 mnz=0.7029E+1|
| FYLD = 24.82 | L3 MNY=0.2518E+2|
| NSF = 1.00 +---+---+---+---+---+---+---+---+---+---| mny=0.1542E+0|
| DFF = 58.11 4.3 VN =0.2699E+3|
| dff = 166.27 ABSOLUTE MZ ENVELOPE vn =0.5926E+1|
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY (KNS-METRE) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 0.4 6.7 0.2 0.2 8.4 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 3 3 3 3 3 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY (KNS-METRE) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS DEFLECTION 0.349 7 |
| 0.31 T -0.15 7.03 0.58 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 132 of 159
Job No Sheet No Rev
1 133 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

321 TAP ERED (BS COLDFORMED SECTIONS

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 133 of 159
Job No Sheet No Rev
1 134 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Steel Design (Track 2) Beam 322 Check 1


|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CMS UNIT |
| * |=============================| ==| |== ------------ |
|MEMBER 322 * | BS COLDFORMED SECTIONS | | | AX=0.4567E+2 |
| * | TAP ERED | | | --Z AY=0.1727E+2 |
|DESIGN CODE * | | | | AZ=0.2000E+2 |
| LRFD 2001 * =============================== ==| |== PY=0.1151E+3 |
| * PZ=0.3062E+3 |
| * |<---LENGTH (M)= 0.66 --->| RY=0.3512E+1 |
|************* RZ=0.8978E+1 |
| |
| 4.5 (KNS-METRE) |
|PARAMETER |L3 CAPACITIES |
|IN KNS CMS | L3 IN KNS METRE |
|--------------- + L3 -------------|
| KL/R-Y= 18.89 | L3 PNC=0.9460E+3|
| KL/R-Z= 7.39 + L3 pnc=0.0000E+0|
| UNL = 66.34 | L3 PNT=0.1020E+4|
| CB = 1.00 + pnt=0.2593E+0|
| PHIC = 0.85 | L3 L3 MNZ=0.8611E+2|
| PHIB = 0.90 + L3 mnz=0.3675E+1|
| FYLD = 24.82 | L0 MNY=0.2517E+2|
| NSF = 1.00 +---+---+---+---+---+---+---+---+---+---| mny=0.4401E-1|
| DFF = 58.11 -0.2 VN =0.2314E+3|
| dff = 166.27 ABSOLUTE MZ ENVELOPE vn =0.5676E+1|
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY (KNS-METRE) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 0.3 6.7 0.1 0.0 4.5 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 3 3 3 3 3 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY (KNS-METRE) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS DEFLECTION 0.349 7 |
| 0.26 T -0.04 3.67 0.66 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 134 of 159
Job No Sheet No Rev
1 135 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

322 TAP ERED (BS COLDFORMED SECTIONS

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 135 of 159
Job No Sheet No Rev
1 136 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Steel Design (Track 2) Beam 323 Check 1


|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CMS UNIT |
| * |=============================| ==| |== ------------ |
|MEMBER 323 * | BS COLDFORMED SECTIONS | | | AX=0.6840E+2 |
| * | TAP ERED | | | --Z AY=0.4000E+2 |
|DESIGN CODE * | | | | AZ=0.2000E+2 |
| LRFD 2001 * =============================== ==| |== PY=0.1196E+3 |
| * PZ=0.1076E+4 |
| * |<---LENGTH (M)= 0.58 --->| RY=0.2873E+1 |
|************* RZ=0.1926E+2 |
| |
| 81.3 (KNS-METRE) |
|PARAMETER |L7 CAPACITIES |
|IN KNS CMS | L7 IN KNS METRE |
|--------------- + L7 L7 -------------|
| KL/R-Y= 20.08 | L7 PNC=0.1414E+4|
| KL/R-Z= 3.00 + pnc=0.1505E+1|
| UNL = 57.70 | L7 L7 PNT=0.1528E+4|
| CB = 1.00 + pnt=0.0000E+0|
| PHIC = 0.85 | L7 MNZ=0.2671E+3|
| PHIB = 0.90 + L7 L7 mnz=0.8134E+2|
| FYLD = 24.82 | L7 MNY=0.2522E+2|
| NSF = 1.00 +---+---+---+---+---+---+---+---+---+---| mny=0.2714E+1|
| DFF = 58.11 64.0 VN =0.5361E+3|
| dff = 166.27 ABSOLUTE MZ ENVELOPE vn =0.2872E+2|
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY (KNS-METRE) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 1.5 28.7 1.1 2.7 81.3 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 7 7 5 3 7 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY (KNS-METRE) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS LRFD-H1-1B-C 0.413 7 |
| 1.51 C 2.71 81.34 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 136 of 159
Job No Sheet No Rev
1 137 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

323 TAP ERED (BS COLDFORMED SECTIONS

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 137 of 159
Job No Sheet No Rev
1 138 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Steel Design (Track 2) Beam 324 Check 1


|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CMS UNIT |
| * |=============================| ==| |== ------------ |
|MEMBER 324 * | BS COLDFORMED SECTIONS | | | AX=0.6840E+2 |
| * | TAP ERED | | | --Z AY=0.4000E+2 |
|DESIGN CODE * | | | | AZ=0.2000E+2 |
| LRFD 2001 * =============================== ==| |== PY=0.1196E+3 |
| * PZ=0.1076E+4 |
| * |<---LENGTH (M)= 0.58 --->| RY=0.2873E+1 |
|************* RZ=0.1926E+2 |
| |
| 48.6 (KNS-METRE) |
|PARAMETER |L3 CAPACITIES |
|IN KNS CMS | L3 IN KNS METRE |
|--------------- + L3 L3 -------------|
| KL/R-Y= 20.08 | L3 PNC=0.1414E+4|
| KL/R-Z= 3.00 + pnc=0.0000E+0|
| UNL = 57.70 | L3 L3 PNT=0.1528E+4|
| CB = 1.00 + pnt=0.8484E+0|
| PHIC = 0.85 | L3 MNZ=0.2671E+3|
| PHIB = 0.90 + L3 mnz=0.4546E+2|
| FYLD = 24.82 | L3 MNY=0.2522E+2|
| NSF = 1.00 +---+---+---+---+---+---+---+---+---+---| mny=0.2756E+1|
| DFF = 58.11 38.3 VN =0.5361E+3|
| dff = 166.27 ABSOLUTE MZ ENVELOPE vn =0.1619E+2|
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY (KNS-METRE) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 0.9 16.9 1.1 2.8 48.6 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 3 3 5 3 3 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY (KNS-METRE) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS DEFLECTION 0.349 7 |
| 0.85 T -2.76 45.46 0.58 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 138 of 159
Job No Sheet No Rev
1 139 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

324 TAP ERED (BS COLDFORMED SECTIONS

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 139 of 159
Job No Sheet No Rev
1 140 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Steel Design (Track 2) Beam 325 Check 1


|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CMS UNIT |
| * |=============================| ==| |== ------------ |
|MEMBER 325 * | BS COLDFORMED SECTIONS | | | AX=0.6554E+2 |
| * | TAP ERED | | | --Z AY=0.3714E+2 |
|DESIGN CODE * | | | | AZ=0.2000E+2 |
| LRFD 2001 * =============================== ==| |== PY=0.1185E+3 |
| * PZ=0.8552E+3 |
| * |<---LENGTH (M)= 1.14 --->| RY=0.2935E+1 |
|************* RZ=0.1804E+2 |
| |
| 64.9 (KNS-METRE) |
|PARAMETER |L7 CAPACITIES |
|IN KNS CMS | L7 IN KNS METRE |
|--------------- + L7 L7 -------------|
| KL/R-Y= 38.75 | L7 PNC=0.1280E+4|
| KL/R-Z= 6.30 + pnc=0.1213E+1|
| UNL = 113.70 | L7 L7 PNT=0.1464E+4|
| CB = 1.00 + pnt=0.0000E+0|
| PHIC = 0.85 | L7 MNZ=0.2404E+3|
| PHIB = 0.90 + L7 L7 mnz=0.6488E+2|
| FYLD = 24.82 | L7 MNY=0.2522E+2|
| NSF = 1.00 +---+---+---+---+---+---+---+---+---+---| mny=0.2146E+1|
| DFF = 58.11 37.5 VN =0.4978E+3|
| dff = 166.27 ABSOLUTE MZ ENVELOPE vn =0.2315E+2|
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY (KNS-METRE) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 1.2 23.2 0.9 2.1 64.9 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 7 7 3 3 7 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY (KNS-METRE) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS LRFD-H1-1B-C 0.355 7 |
| 1.21 C 2.15 64.88 0.00 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 140 of 159
Job No Sheet No Rev
1 141 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

325 TAP ERED (BS COLDFORMED SECTIONS

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 141 of 159
Job No Sheet No Rev
1 142 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Steel Design (Track 2) Beam 326 Check 1


|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CMS UNIT |
| * |=============================| ==| |== ------------ |
|MEMBER 326 * | BS COLDFORMED SECTIONS | | | AX=0.5990E+2 |
| * | TAP ERED | | | --Z AY=0.3150E+2 |
|DESIGN CODE * | | | | AZ=0.2000E+2 |
| LRFD 2001 * =============================== ==| |== PY=0.1173E+3 |
| * PZ=0.6507E+3 |
| * |<---LENGTH (M)= 1.16 --->| RY=0.3069E+1 |
|************* RZ=0.1558E+2 |
| |
| 38.9 (KNS-METRE) |
|PARAMETER |L7 CAPACITIES |
|IN KNS CMS | L7 IN KNS METRE |
|--------------- + L7 L7 -------------|
| KL/R-Y= 37.70 | L7 PNC=0.1175E+4|
| KL/R-Z= 7.43 + pnc=0.9059E+0|
| UNL = 115.70 | L7 L7 PNT=0.1338E+4|
| CB = 1.00 + pnt=0.0000E+0|
| PHIC = 0.85 | L7 MNZ=0.1910E+3|
| PHIB = 0.90 + L7 L7 mnz=0.3893E+2|
| FYLD = 24.82 | L7 MNY=0.2520E+2|
| NSF = 1.00 +---+---+---+---+---+---+---+---+---+---| mny=0.1222E+1|
| DFF = 58.11 18.2 VN =0.4223E+3|
| dff = 166.27 ABSOLUTE MZ ENVELOPE vn =0.1729E+2|
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY (KNS-METRE) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 0.9 17.3 0.7 1.2 38.9 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 7 7 3 3 7 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY (KNS-METRE) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS DEFLECTION 0.349 7 |
| 0.91 C 1.22 38.93 1.16 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 142 of 159
Job No Sheet No Rev
1 143 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

326 TAP ERED (BS COLDFORMED SECTIONS

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 143 of 159
Job No Sheet No Rev
1 144 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Steel Design (Track 2) Beam 327 Check 1


|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CMS UNIT |
| * |=============================| ==| |== ------------ |
|MEMBER 327 * | BS COLDFORMED SECTIONS | | | AX=0.5417E+2 |
| * | TAP ERED | | | --Z AY=0.2577E+2 |
|DESIGN CODE * | | | | AZ=0.2000E+2 |
| LRFD 2001 * =============================== ==| |== PY=0.1162E+3 |
| * PZ=0.4699E+3 |
| * |<---LENGTH (M)= 1.14 --->| RY=0.3226E+1 |
|************* RZ=0.1300E+2 |
| |
| 19.3 (KNS-METRE) |
|PARAMETER |L7 CAPACITIES |
|IN KNS CMS | L7 IN KNS METRE |
|--------------- + L7 L7 -------------|
| KL/R-Y= 35.24 | L7 PNC=0.1072E+4|
| KL/R-Z= 8.75 + pnc=0.6009E+0|
| UNL = 113.70 | L7 L7 PNT=0.1210E+4|
| CB = 1.00 + pnt=0.0000E+0|
| PHIC = 0.85 | L7 MNZ=0.1454E+3|
| PHIB = 0.90 + L7 L7 mnz=0.1929E+2|
| FYLD = 24.82 | L7 MNY=0.2519E+2|
| NSF = 1.00 +---+---+---+---+---+---+---+---+---+---| mny=0.5471E+0|
| DFF = 58.11 5.9 VN =0.3454E+3|
| dff = 166.27 ABSOLUTE MZ ENVELOPE vn =0.1147E+2|
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY (KNS-METRE) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 0.6 11.5 0.5 0.5 19.3 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 7 7 3 3 7 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY (KNS-METRE) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS DEFLECTION 0.349 7 |
| 0.60 C 0.55 19.29 1.14 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 144 of 159
Job No Sheet No Rev
1 145 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

327 TAP ERED (BS COLDFORMED SECTIONS

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 145 of 159
Job No Sheet No Rev
1 146 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Steel Design (Track 2) Beam 328 Check 1


|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CMS UNIT |
| * |=============================| ==| |== ------------ |
|MEMBER 328 * | BS COLDFORMED SECTIONS | | | AX=0.4853E+2 |
| * | TAP ERED | | | --Z AY=0.2013E+2 |
|DESIGN CODE * | | | | AZ=0.2000E+2 |
| LRFD 2001 * =============================== ==| |== PY=0.1156E+3 |
| * PZ=0.3855E+3 |
| * |<---LENGTH (M)= 0.58 --->| RY=0.3407E+1 |
|************* RZ=0.1036E+2 |
| |
| 6.6 (KNS-METRE) |
|PARAMETER |L7 CAPACITIES |
|IN KNS CMS | L7 IN KNS METRE |
|--------------- + L7 L7 -------------|
| KL/R-Y= 16.98 | L7 PNC=0.1009E+4|
| KL/R-Z= 5.58 + pnc=0.2996E+0|
| UNL = 57.85 | L7 L7 PNT=0.1084E+4|
| CB = 1.00 + pnt=0.0000E+0|
| PHIC = 0.85 | L7 MNZ=0.1050E+3|
| PHIB = 0.90 + L7 L7 mnz=0.6561E+1|
| FYLD = 24.82 | L7 MNY=0.2518E+2|
| NSF = 1.00 +---+---+---+---+---+---+---+---+---+---| mny=0.1445E+0|
| DFF = 58.11 3.1 VN =0.2699E+3|
| dff = 166.27 ABSOLUTE MZ ENVELOPE vn =0.5717E+1|
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY (KNS-METRE) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 0.3 5.7 0.2 0.1 6.6 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 7 7 3 3 7 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY (KNS-METRE) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS DEFLECTION 0.349 7 |
| 0.30 C 0.14 6.56 0.58 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 146 of 159
Job No Sheet No Rev
1 147 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

328 TAP ERED (BS COLDFORMED SECTIONS

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 147 of 159
Job No Sheet No Rev
1 148 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Steel Design (Track 2) Beam 329 Check 1


|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CMS UNIT |
| * |=============================| ==| |== ------------ |
|MEMBER 329 * | BS COLDFORMED SECTIONS | | | AX=0.4567E+2 |
| * | TAP ERED | | | --Z AY=0.1727E+2 |
|DESIGN CODE * | | | | AZ=0.2000E+2 |
| LRFD 2001 * =============================== ==| |== PY=0.1151E+3 |
| * PZ=0.3062E+3 |
| * |<---LENGTH (M)= 0.62 --->| RY=0.3512E+1 |
|************* RZ=0.8978E+1 |
| |
| 3.3 (KNS-METRE) |
|PARAMETER |L7 CAPACITIES |
|IN KNS CMS | L7 IN KNS METRE |
|--------------- + L7 L7 -------------|
| KL/R-Y= 17.75 | L7 PNC=0.9480E+3|
| KL/R-Z= 6.94 + pnc=0.2657E+0|
| UNL = 62.34 | L7 L7 PNT=0.1020E+4|
| CB = 1.00 + pnt=0.0000E+0|
| PHIC = 0.85 | L7 MNZ=0.8611E+2|
| PHIB = 0.90 + L7 L7 mnz=0.3328E+1|
| FYLD = 24.82 | L0 MNY=0.2517E+2|
| NSF = 1.00 +---+---+---+---+---+---+---+---+---+---| mny=0.3887E-1|
| DFF = 58.11 -0.2 VN =0.2314E+3|
| dff = 166.27 ABSOLUTE MZ ENVELOPE vn =0.5466E+1|
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY (KNS-METRE) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 0.3 5.5 0.1 0.0 3.3 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 7 7 3 3 7 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY (KNS-METRE) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS DEFLECTION 0.349 7 |
| 0.27 C 0.04 3.33 0.62 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 148 of 159
Job No Sheet No Rev
1 149 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

329 TAP ERED (BS COLDFORMED SECTIONS

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 149 of 159
Job No Sheet No Rev
1 150 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Steel Design (Track 2) Beam 330 Check 1


|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CMS UNIT |
| * |=============================| ==| |== ------------ |
|MEMBER 330 * | BS COLDFORMED SECTIONS | | | AX=0.6554E+2 |
| * | TAP ERED | | | --Z AY=0.3714E+2 |
|DESIGN CODE * | | | | AZ=0.2000E+2 |
| LRFD 2001 * =============================== ==| |== PY=0.1185E+3 |
| * PZ=0.8552E+3 |
| * |<---LENGTH (M)= 1.14 --->| RY=0.2935E+1 |
|************* RZ=0.1804E+2 |
| |
| 38.9 (KNS-METRE) |
|PARAMETER |L3 CAPACITIES |
|IN KNS CMS | L3 IN KNS METRE |
|--------------- + L3 -------------|
| KL/R-Y= 38.75 | L3 PNC=0.1280E+4|
| KL/R-Z= 6.30 + pnc=0.0000E+0|
| UNL = 113.70 | L3 PNT=0.1464E+4|
| CB = 1.00 + pnt=0.6883E+0|
| PHIC = 0.85 | L3 MNZ=0.2404E+3|
| PHIB = 0.90 + L3 L3 mnz=0.3622E+2|
| FYLD = 24.82 | L3 MNY=0.2522E+2|
| NSF = 1.00 +---+---+---+---+---+---+---+---+---+---| mny=0.2184E+1|
| DFF = 58.11 22.7 VN =0.4978E+3|
| dff = 166.27 ABSOLUTE MZ ENVELOPE vn =0.1313E+2|
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY (KNS-METRE) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 0.7 13.5 0.9 2.2 38.9 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 3 3 3 3 3 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY (KNS-METRE) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS DEFLECTION 0.349 7 |
| 0.69 T -2.18 36.22 1.14 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 150 of 159
Job No Sheet No Rev
1 151 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

330 TAP ERED (BS COLDFORMED SECTIONS

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 151 of 159
Job No Sheet No Rev
1 152 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Steel Design (Track 2) Beam 331 Check 1


|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CMS UNIT |
| * |=============================| ==| |== ------------ |
|MEMBER 331 * | BS COLDFORMED SECTIONS | | | AX=0.5990E+2 |
| * | TAP ERED | | | --Z AY=0.3150E+2 |
|DESIGN CODE * | | | | AZ=0.2000E+2 |
| LRFD 2001 * =============================== ==| |== PY=0.1173E+3 |
| * PZ=0.6507E+3 |
| * |<---LENGTH (M)= 1.16 --->| RY=0.3069E+1 |
|************* RZ=0.1558E+2 |
| |
| 23.5 (KNS-METRE) |
|PARAMETER |L3 CAPACITIES |
|IN KNS CMS | L3 L3 IN KNS METRE |
|--------------- + L3 -------------|
| KL/R-Y= 37.70 | L3 PNC=0.1175E+4|
| KL/R-Z= 7.43 + pnc=0.0000E+0|
| UNL = 115.70 | L3 L3 PNT=0.1338E+4|
| CB = 1.00 + pnt=0.5123E+0|
| PHIC = 0.85 | L3 L3 MNZ=0.1910E+3|
| PHIB = 0.90 + L3 L3 mnz=0.2166E+2|
| FYLD = 24.82 | L3 MNY=0.2520E+2|
| NSF = 1.00 +---+---+---+---+---+---+---+---+---+---| mny=0.1250E+1|
| DFF = 58.11 11.2 VN =0.4223E+3|
| dff = 166.27 ABSOLUTE MZ ENVELOPE vn =0.9775E+1|
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY (KNS-METRE) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 0.5 10.1 0.7 1.3 23.5 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 3 3 3 3 3 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY (KNS-METRE) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS DEFLECTION 0.349 7 |
| 0.51 T -1.25 21.66 1.16 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 152 of 159
Job No Sheet No Rev
1 153 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

331 TAP ERED (BS COLDFORMED SECTIONS

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 153 of 159
Job No Sheet No Rev
1 154 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Steel Design (Track 2) Beam 332 Check 1


|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CMS UNIT |
| * |=============================| ==| |== ------------ |
|MEMBER 332 * | BS COLDFORMED SECTIONS | | | AX=0.5417E+2 |
| * | TAP ERED | | | --Z AY=0.2577E+2 |
|DESIGN CODE * | | | | AZ=0.2000E+2 |
| LRFD 2001 * =============================== ==| |== PY=0.1162E+3 |
| * PZ=0.4699E+3 |
| * |<---LENGTH (M)= 1.14 --->| RY=0.3226E+1 |
|************* RZ=0.1300E+2 |
| |
| 11.9 (KNS-METRE) |
|PARAMETER |L3 CAPACITIES |
|IN KNS CMS | L3 IN KNS METRE |
|--------------- + L3 L3 -------------|
| KL/R-Y= 35.24 | L3 PNC=0.1072E+4|
| KL/R-Z= 8.75 + pnc=0.0000E+0|
| UNL = 113.70 | L3 L3 PNT=0.1210E+4|
| CB = 1.00 + pnt=0.3388E+0|
| PHIC = 0.85 | L3 L3 MNZ=0.1454E+3|
| PHIB = 0.90 + L3 L3 mnz=0.1071E+2|
| FYLD = 24.82 | L3 MNY=0.2519E+2|
| NSF = 1.00 +---+---+---+---+---+---+---+---+---+---| mny=0.5659E+0|
| DFF = 58.11 3.8 VN =0.3454E+3|
| dff = 166.27 ABSOLUTE MZ ENVELOPE vn =0.6464E+1|
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY (KNS-METRE) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 0.4 6.7 0.5 0.6 11.9 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 3 3 3 3 3 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY (KNS-METRE) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS DEFLECTION 0.349 7 |
| 0.34 T -0.57 10.71 1.14 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 154 of 159
Job No Sheet No Rev
1 155 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

332 TAP ERED (BS COLDFORMED SECTIONS

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 155 of 159
Job No Sheet No Rev
1 156 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Steel Design (Track 2) Beam 333 Check 1


|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CMS UNIT |
| * |=============================| ==| |== ------------ |
|MEMBER 333 * | BS COLDFORMED SECTIONS | | | AX=0.4853E+2 |
| * | TAP ERED | | | --Z AY=0.2013E+2 |
|DESIGN CODE * | | | | AZ=0.2000E+2 |
| LRFD 2001 * =============================== ==| |== PY=0.1156E+3 |
| * PZ=0.3855E+3 |
| * |<---LENGTH (M)= 0.58 --->| RY=0.3407E+1 |
|************* RZ=0.1036E+2 |
| |
| 4.2 (KNS-METRE) |
|PARAMETER |L3 CAPACITIES |
|IN KNS CMS | L3 IN KNS METRE |
|--------------- + L3 L3 -------------|
| KL/R-Y= 16.98 | L3 PNC=0.1009E+4|
| KL/R-Z= 5.58 + pnc=0.0000E+0|
| UNL = 57.85 | L3 L3 PNT=0.1084E+4|
| CB = 1.00 + pnt=0.1689E+0|
| PHIC = 0.85 | L3 L3 MNZ=0.1050E+3|
| PHIB = 0.90 + L3 mnz=0.3673E+1|
| FYLD = 24.82 | L3 MNY=0.2518E+2|
| NSF = 1.00 +---+---+---+---+---+---+---+---+---+---| mny=0.1542E+0|
| DFF = 58.11 2.1 VN =0.2699E+3|
| dff = 166.27 ABSOLUTE MZ ENVELOPE vn =0.3224E+1|
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY (KNS-METRE) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 0.2 3.4 0.2 0.2 4.2 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 3 3 3 3 3 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY (KNS-METRE) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS DEFLECTION 0.349 7 |
| 0.17 T -0.15 3.67 0.58 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 156 of 159
Job No Sheet No Rev
1 157 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

333 TAP ERED (BS COLDFORMED SECTIONS

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 157 of 159
Job No Sheet No Rev
1 158 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

Steel Design (Track 2) Beam 334 Check 1


|--------------------------------------------------------------------------|
| Y PROPERTIES |
|************* | IN CMS UNIT |
| * |=============================| ==| |== ------------ |
|MEMBER 334 * | BS COLDFORMED SECTIONS | | | AX=0.4567E+2 |
| * | TAP ERED | | | --Z AY=0.1727E+2 |
|DESIGN CODE * | | | | AZ=0.2000E+2 |
| LRFD 2001 * =============================== ==| |== PY=0.1151E+3 |
| * PZ=0.3062E+3 |
| * |<---LENGTH (M)= 0.66 --->| RY=0.3512E+1 |
|************* RZ=0.8978E+1 |
| |
| 2.2 (KNS-METRE) |
|PARAMETER |L3 CAPACITIES |
|IN KNS CMS | L3 IN KNS METRE |
|--------------- + L3 -------------|
| KL/R-Y= 18.89 | L3 PNC=0.9460E+3|
| KL/R-Z= 7.39 + L3 pnc=0.0000E+0|
| UNL = 66.34 | L3 PNT=0.1020E+4|
| CB = 1.00 + pnt=0.1358E+0|
| PHIC = 0.85 | L3 L3 MNZ=0.8611E+2|
| PHIB = 0.90 + L3 mnz=0.1882E+1|
| FYLD = 24.82 | L0 MNY=0.2517E+2|
| NSF = 1.00 +---+---+---+---+---+---+---+---+---+---| mny=0.4401E-1|
| DFF = 58.11 -0.1 VN =0.2314E+3|
| dff = 166.27 ABSOLUTE MZ ENVELOPE vn =0.2973E+1|
| (WITH LOAD NO.) |
| |
| MAX FORCE/ MOMENT SUMMARY (KNS-METRE) |
| ------------------------- |
| |
| AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z |
| |
| VALUE 0.2 3.4 0.1 0.0 2.2 |
| LOCATION 0.0 0.0 0.0 0.0 0.0 |
| LOADING 3 3 3 3 3 |
| |
|**************************************************************************|
|* *|
|* DESIGN SUMMARY (KNS-METRE) *|
|* -------------- *|
|* *|
|* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *|
| FX MY MZ LOCATION |
| ====================================================== |
| PASS DEFLECTION 0.349 7 |
| 0.14 T -0.04 1.88 0.66 |
|* *|
|**************************************************************************|
| |
|--------------------------------------------------------------------------

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 158 of 159
Job No Sheet No Rev
1 159 00

Software licensed to STAAD.Pro Advanced Part 1/1


CONNECTED User: Not signed in
Job Title Solar Carport Structure Double 40m/s Ref

By New Gateway of Date


Dubai
2/9/2024 Chd SD
Client RUW File 5 Panels portrait Date/Time
structure-RUW 40m-s
09-Mar-2024
- 3 Carpark
18:37
2.STD

334 TAP ERED (BS COLDFORMED SECTIONS

Print Time/Date: 09/03/2024 18:45 STAAD.Pro CONNECT Edition 22.00.00.15 Print Run 159 of 159