PROYEK : PRESERVASI JALAN LINGKAR TIMUR PRABUMULIH

KONTRAKTOR : PT. SENECA INDONESIA


KONSULTAN : PT. GLOBAL PROFEX SYNERGY, (KSO)

: PT. WINSOLUSI KONSULTAN , SEECONS

SUMMARY
COMPRESSIVE STRENGTH TEST
(SNI .1974 - 2011 )

PEKERJAAN : BETON MUTU = FC 10 Mpa


LOKASI : LEAN CONCRETE ( Untuk Rigid )
PERIODE : 26 April sd 25 Mei 2023

LOKASI COR TANGGAL TANGGAL AVERAGE (Mpa) Specification Persen


NO L/R REMARK
STA COR TEST 7 Hr 28 Hr (Mpa) Strength (%)

9 5+050 sd 5+250 R 15-May-23 22-May-23 12.2 - 10 122%


13-Jun-23 - 22.93 10 229.3

10 5+300 sd5+600 R 16-May-23 23-May-23 12.4 - 10 124.0


14-Jun-23 - 23.11 10 231.1

11 5+300 sd 5+600 R 17-May-23 24-May-23 12.4 - 10 124.0


15-Jun-23 - 10 0.0

12 5+300 sd 5+600 R 18-May-23 25-May-23 12.4 - 10 124.0


16-Jun-23 - 10 0.0

Disetujui Oleh Diperiksa Oleh : Dikerjakan Oleh :


PU. BINA MARGA KONSULTAN KONTRAKTOR

S U A N D I , ST A. MAULANA
Pengawas Lap Quality Engineer Quality Engineer
PROYEK : PRESERVASI JALAN LINGKAR TIMUR PRABUMULIH
KONTRAKTOR : PT. SENECA INDONESIA
KONSULTAN : PT. GLOBAL PROFEX SYNERGY (KSO)
: PT. WINSOLUSI KONSULTAN, SEECONS

UJI KUAT TEKAN BETON SILINDER


(SNI 1974 - 2011)

Luas Beban Konversi 28 hari Persen


Tanggal Umur Beton BERAT Tegangan Faktor
No Kode Sampel Slump Penampang Maks Cyl Spec Strength Cek
Mutu Koreksi
Dicor Dites (hari) (cm²) Gram (KN) (kg) (Mpa) (Mpa) (Mpa) (%)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
101.9367991845 10.197

1 BETON FC 10 Mpa - LC 18-May-2023 25-May-2023 7 FC 10 7 176.71 12320 225 22935.8 12.7 0.65 19.6 10 127.28
2 LC STA: 5+300 sd 5+600 R 7 Mpa 176.71 12321 200 20387.36 11.3 0.65 17.4 10 113.14
3 7 176.71 12287 230 23445.46 13.0 0.65 20.0 10 130.11
Rata-rata : 12309.33 12.4 19.0
1 BETON FC 10 Mpa - LC 18-May-2023 25-May-2023 7 FC 10 7.0 176.71 23228 230 23445.5 13.0 0.65 20.0 10 130.11
2 LC STA: 4+900 sd 5+050 R 7 Mpa 176.71 12231 225 22935.78 12.7 0.65 19.6 10 127.28
3 7 176.71 12335 235 23955.15 13.3 0.65 20.5 10 132.94
Rata-rata : 15931.33 13.0 20.0
1 kn = *1000/9,81

APPROVED By : CHECKED By : TESTED By :


PU.BINA MARGA KONSULTAN KONTRAKTOR

.......................................................... ........................................................... ................................................................


Pengawas Lap Lab .Tech Quality Control / Lab
PROYEK : PRESERVASI JALAN LINGKAR TIMUR PRABUMULIH
KONTRAKTOR : PT. SENECA INDONESIA
KONSULTAN : PT. GLOBAL PROFEX SYNERGY (KSO)
: PT. WINSOLUSI KONSULTAN, SEECONS

UJI KUAT TEKAN BETON SILINDER


(SNI 1974 - 2011)

Luas Beban Konversi 28 hari Persen


Tanggal Umur Beton BERAT Tegangan Faktor
No Kode Sampel Slump Penampang Maks Cyl Spec Strength Cek
Mutu Koreksi
Dicor Dites (hari) (cm²) Gram (KN) (kg) (Mpa) (Mpa) (Mpa) (%)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
101.9367991845 10.197

1 BETON FC 10 Mpa - LC 17-May-2023 24-May-2023 7 FC 10 7 176.71 12320 225 22935.8 12.7 0.65 19.6 10 127.28
2 LC STA: 5+300 sd 5+600 R 7 Mpa 176.71 12321 200 20387.36 11.3 0.65 17.4 10 113.14
3 7 176.71 12287 230 23445.46 13.0 0.65 20.0 10 130.11
Rata-rata : 12309.33 12.4 19.0
1 BETON FC 10 Mpa - LC 18-May-2023 25-May-2023 7 FC 10 7.0 176.71 23228 230 23445.5 13.0 0.65 20.0 10 130.11
2 LC STA: 4+900 sd 5+050 R 7 Mpa 176.71 12231 225 22935.78 12.7 0.65 19.6 10 127.28
3 7 176.71 12335 235 23955.15 13.3 0.65 20.5 10 132.94
Rata-rata : 15931.33 13.0 20.0
1 kn = *1000/9,81

APPROVED By : CHECKED By : TESTED By :


PU.BINA MARGA KONSULTAN KONTRAKTOR

.......................................................... ........................................................... ................................................................


Pengawas Lap Lab .Tech Quality Control / Lab
PROYEK : PRESERVASI JALAN LINGKAR TIMUR PRABUMULIH
KONTRAKTOR : PT. SENECA INDONESIA
KONSULTAN : PT. GLOBAL PROFEX SYNERGY, (KSO)

: PT. WINSOLUSI KONSULTAN , SEECONS

UJI KUAT TEKAN BETON SILINDER

(COMPRESSIVE STRENGTH TEST)


(SNI 1974 - 2011 )

MUTU BETON : FC 10 Mpa

LEAN CONCRETE ( LC )
( LOKASI RIGID )
PROYEK : PRESERVASI JALAN LINGKAR TIMUR PRABUMULIH
KONTRAKTOR : PT. SENECA INDONESIA
KONSULTAN : PT. GLOBAL PROFEX SYNERGY (KSO)
: PT. WINSOLUSI KONSULTAN, SEECONS

UJI KUAT TEKAN BETON SILINDER


(SNI 1974 - 2011)

Luas Beban Konversi 28 hari Persen


Tanggal Umur Beton BERAT Tegangan Faktor
No Kode Sampel Slump Penampang Maks Cyl Spec Strength Cek
Mutu Koreksi
Dicor Dites (hari) (cm²) Gram (KN) (kg) (Mpa) (Mpa) (Mpa) (%)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
101.9367991845 10.197

1 BETON FC 10 Mpa - LC 16-May-2023 23-May-2023 7 FC 10 7 176.71 12320 225 22935.8 12.7 0.65 19.6 10 127.28
2 LC STA: 5+300 sd 5+600 R 7 Mpa 176.71 12321 200 20387.36 11.3 0.65 17.4 10 113.14
3 7 176.71 12287 230 23445.46 13.0 0.65 20.0 10 130.11
Rata-rata : 12309.33 12.4 19.0
1 BETON FC 10 Mpa - LC 18-May-2023 25-May-2023 7 FC 10 7.0 176.71 23228 230 23445.5 13.0 0.65 20.0 10 130.11
2 LC STA: 4+900 sd 5+050 R 7 Mpa 176.71 12231 225 22935.78 12.7 0.65 19.6 10 127.28
3 7 176.71 12335 235 23955.15 13.3 0.65 20.5 10 132.94
Rata-rata : 15931.33 13.0 20.0
1 kn = *1000/9,81

APPROVED By : CHECKED By : TESTED By :


PU.BINA MARGA KONSULTAN KONTRAKTOR

.......................................................... ........................................................... ................................................................


Pengawas Lap Lab .Tech Quality Control / Lab
PROYEK : PRESERVASI JALAN LINGKAR TIMUR PRABUMULIH
KONTRAKTOR : PT. SENECA INDONESIA
KONSULTAN : PT. GLOBAL PROFEX SYNERGY (KSO)
: PT. WINSOLUSI KONSULTAN, SEECONS

UJI KUAT TEKAN BETON SILINDER


(SNI 1974 - 2011)

Luas Beban Konversi 28 hari Persen


Tanggal Umur Beton BERAT Tegangan Faktor
No Kode Sampel Slump Penampang Maks Cyl Spec Strength Cek
Mutu Koreksi
Dicor Dites (hari) (cm²) Gram (KN) (kg) (Mpa) (Mpa) (Mpa) (%)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
101.9367991845 10.197

1 BETON FC 10 Mpa - LC 15-May-2023 22-May-2023 7 FC 10 8 176.71 12338 200 20387.4 11.3 0.65 17.4 10 113.14
2 LC STA: 5+050 sd 5+250 7 Mpa 176.71 12321 225 22935.78 12.7 0.65 19.6 10 127.28
3 7 176.71 12334 220 22426.1 12.4 0.65 19.1 10 124.45
Rata-rata : 12331 12.2 18.7
1 BETON FC 10 Mpa - LC 18-May-2023 25-May-2023 7 FC 10 7.0 176.71 23228 230 23445.5 13.0 0.65 20.0 10 130.11
2 LC STA: 4+900 sd 5+050 R 7 Mpa 176.71 12231 225 22935.78 12.7 0.65 19.6 10 127.28
3 7 176.71 12335 235 23955.15 13.3 0.65 20.5 10 132.94
Rata-rata : 15931.33 13.0 20.0
1 kn = *1000/9,81

APPROVED By : CHECKED By : TESTED By :


PU.BINA MARGA KONSULTAN KONTRAKTOR

.......................................................... ........................................................... ................................................................


Pengawas Lap Lab .Tech Quality Control / Lab
PROYEK : PRESERVASI JALAN LINGKAR TIMUR PRABUMULIH
KONTRAKTOR : PT. SENECA INDONESIA
KONSULTAN : PT. GLOBAL PROFEX SYNERGY (KSO)
: PT. WINSOLUSI KONSULTAN, SEECONS

UJI KUAT TEKAN BETON SILINDER


(SNI 1974 - 2011)

Luas Beban Konversi 28 hari Persen


Tanggal Umur Beton BERAT Tegangan Faktor
No Kode Sampel Slump Penampang Maks Cyl Spec Strength Cek
Mutu Koreksi
Dicor Dites (hari) (cm²) Gram (KN) (kg) (Mpa) (Mpa) (Mpa) (%)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
101.9367991845 10.197

1 BETON FC 10 Mpa - LC 14-May-2023 21-May-2023 7 FC 10 8 176.71 12295 235 23955.1 13.3 0.65 20.5 10 132.94
2 LC STA: 5+050 sd 5+250 7 Mpa 176.71 12266 200 20387.36 11.3 0.65 17.4 10 113.14
3 7 176.71 12288 220 22426.1 12.4 0.65 19.1 10 124.45
Rata-rata : 12283 12.4 19.0
1 BETON FC 10 Mpa - LC 13-May-2023 20-May-2023 7 FC 10 7.0 176.71 23228 230 23445.5 13.0 0.65 20.0 10 130.11
2 LC STA: 4+100 sd 4+450 7 Mpa 176.71 12231 225 22935.78 12.7 0.65 19.6 10 127.28
3 7 176.71 12335 235 23955.15 13.3 0.65 20.5 10 132.94
Rata-rata : 15931.33 13.0 20.0
1 kn = *1000/9,81

APPROVED By : CHECKED By : TESTED By :


PU.BINA MARGA KONSULTAN KONTRAKTOR

.......................................................... ........................................................... ................................................................


Pengawas Lap Lab .Tech Quality Control / Lab
PROYEK : PRESERVASI JALAN LINGKAR TIMUR PRABUMULIH
KONTRAKTOR : PT. SENECA INDONESIA
KONSULTAN : PT. GLOBAL PROFEX SYNERGY (KSO)
: PT. WINSOLUSI KONSULTAN, SEECONS

UJI KUAT TEKAN BETON SILINDER


(SNI 1974 - 2011)

Luas Beban Konversi 28 hari Persen


Tanggal Umur Beton BERAT Tegangan Faktor
No Kode Sampel Slump Penampang Maks Cyl Spec Strength Cek
Mutu Koreksi
Dicor Dites (hari) (cm²) Gram (KN) (kg) (Mpa) (Mpa) (Mpa) (%)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
101.9367991845 10.197

1 BETON FC 10 Mpa - LC 13-May-2023 20-May-2023 7 FC 10 7.5 176.71 12344 200 20387.4 11.3 0.65 17.4 10 113.14
2 LC STA: 5+600 sd 5+825 R 7 Mpa 176.71 12452 225 22935.78 12.7 0.65 19.6 10 127.28
3 7 176.71 12279 220 22426.1 12.4 0.65 19.1 10 124.45
Rata-rata : 12358.33 12.2 18.7
1 BETON FC 10 Mpa - LC 13-May-2023 20-May-2023 7 FC 10 7.0 176.71 23228 230 23445.5 13.0 0.65 20.0 10 130.11
2 LC STA: 4+100 sd 4+450 7 Mpa 176.71 12231 225 22935.78 12.7 0.65 19.6 10 127.28
3 7 176.71 12335 235 23955.15 13.3 0.65 20.5 10 132.94
Rata-rata : 15931.33 13.0 20.0
1 kn = *1000/9,81

APPROVED By : CHECKED By : TESTED By :


PU.BINA MARGA KONSULTAN KONTRAKTOR

.......................................................... ........................................................... ................................................................


Pengawas Lap Lab .Tech Quality Control / Lab
PROYEK : PRESERVASI JALAN LINGKAR TIMUR PRABUMULIH
KONTRAKTOR : PT. SENECA INDONESIA
KONSULTAN : PT. GLOBAL PROFEX SYNERGY (KSO)
: PT. WINSOLUSI KONSULTAN, SEECONS

UJI KUAT TEKAN BETON SILINDER


(SNI 1974 - 2011)

Luas Beban Konversi 28 hari Persen


Tanggal Umur Beton BERAT Tegangan Faktor
No Kode Sampel Slump Penampang Maks Cyl Spec Strength Cek
Mutu Koreksi
Dicor Dites (hari) (cm²) Gram (KN) (kg) (Mpa) (Mpa) (Mpa) (%)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
101.9367991845 10.197

1 BETON FC 10 Mpa - LC 12-May-2023 19-May-2023 7 FC 10 7.5 176.71 12344 200 20387.4 11.3 0.65 17.4 10 113.14
2 LC STA: 5+600 sd 5+825 R 7 Mpa 176.71 12452 225 22935.78 12.7 0.65 19.6 10 127.28
3 7 176.71 12279 220 22426.1 12.4 0.65 19.1 10 124.45
Rata-rata : 12358.33 12.2 18.7
1 BETON FC 10 Mpa - LC 13-May-2023 20-May-2023 7 FC 10 7.0 176.71 23228 230 23445.5 13.0 0.65 20.0 10 130.11
2 LC STA: 4+100 sd 4+450 7 Mpa 176.71 12231 225 22935.78 12.7 0.65 19.6 10 127.28
3 7 176.71 12335 235 23955.15 13.3 0.65 20.5 10 132.94
Rata-rata : 15931.33 13.0 20.0
1 kn = *1000/9,81

APPROVED By : CHECKED By : TESTED By :


PU.BINA MARGA KONSULTAN KONTRAKTOR

.......................................................... ........................................................... ................................................................


Pengawas Lap Lab .Tech Quality Control / Lab
PROYEK : PRESERVASI JALAN LINGKAR TIMUR PRABUMULIH
KONTRAKTOR : PT. SENECA INDONESIA
KONSULTAN : PT. GLOBAL PROFEX SYNERGY (KSO)
: PT. WINSOLUSI KONSULTAN, SEECONS

UJI KUAT TEKAN BETON SILINDER


(SNI 1974 - 2011)

Luas Beban Konversi 28 hari Persen


Tanggal Umur Beton BERAT Tegangan Faktor
No Kode Sampel Slump Penampang Maks Cyl Spec Strength Cek
Mutu Koreksi
Dicor Dites (hari) (cm²) Gram (KN) (kg) (Mpa) (Mpa) (Mpa) (%)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
101.9367991845 10.197

1 BETON FC 10 Mpa - LC 11-May-2023 18-May-2023 7 FC 10 7.5 176.71 12338 235 23955.1 13.3 0.65 20.5 10 132.94
2 LC STA: 4+900 sd 5+050 R 7 Mpa 176.71 12452 225 22935.78 12.7 0.65 19.6 10 127.28
3 7 176.71 12331 235 23955.15 13.3 0.65 20.5 10 132.94
Rata-rata : 12373.67 13.1 20.2
1 BETON FC 10 Mpa - LC 18-May-2023 25-May-2023 7 FC 10 7.0 176.71 23228 230 23445.5 13.0 0.65 20.0 10 130.11
2 LC STA: 4+900 sd 5+050 R 7 Mpa 176.71 12231 225 22935.78 12.7 0.65 19.6 10 127.28
3 7 176.71 12335 235 23955.15 13.3 0.65 20.5 10 132.94
Rata-rata : 15931.33 13.0 20.0
1 kn = *1000/9,81

APPROVED By : CHECKED By : TESTED By :


PU.BINA MARGA KONSULTAN KONTRAKTOR

.......................................................... ........................................................... ................................................................


Pengawas Lap Lab .Tech Quality Control / Lab
PROYEK : PRESERVASI JALAN LINGKAR TIMUR PRABUMULIH
KONTRAKTOR : PT. SENECA INDONESIA
KONSULTAN : PT. GLOBAL PROFEX SYNERGY (KSO)
: PT. WINSOLUSI KONSULTAN, SEECONS

UJI KUAT TEKAN BETON SILINDER


(SNI 1974 - 2011)

Luas Beban Konversi 28 hari Persen


Tanggal Umur Beton BERAT Tegangan Faktor
No Kode Sampel Slump Penampang Maks Cyl Spec Strength Cek
Mutu Koreksi
Dicor Dites (hari) (cm²) Gram (KN) (kg) (Mpa) (Mpa) (Mpa) (%)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
101.9367991845 10.197

1 BETON FC 10 Mpa - LC 10-May-2023 17-May-2023 7 FC 10 8 176.71 12265 225 22935.8 12.7 0.65 19.6 10 127.28
2 LC STA: 4+900 sd 5+050 R 7 Mpa 176.71 12452 225 22935.78 12.7 0.65 19.6 10 127.28
3 7 176.71 12229 220 22426.1 12.4 0.65 19.1 10 124.45
Rata-rata : 12315.33 12.6 19.4
1 BETON FC 10 Mpa - LC 18-May-2023 25-May-2023 7 FC 10 7.0 176.71 12243 235 23955.1 13.3 0.65 20.5 10 132.94
2 LC STA: 4+900 sd 5+050 R 7 Mpa 176.71 12222 225 22935.78 12.7 0.65 19.6 10 127.28
3 7 176.71 12334 220 22426.1 12.4 0.65 19.1 10 124.45
Rata-rata : 12266.33 12.8 19.7
1 kn = *1000/9,81

APPROVED By : CHECKED By : TESTED By :


PU.BINA MARGA KONSULTAN KONTRAKTOR

.......................................................... ........................................................... ................................................................


Pengawas Lap Lab .Tech Quality Control / Lab
PROYEK : PRESERVASI JALAN LINGKAR TIMUR PRABUMULIH
KONTRAKTOR : PT. SENECA INDONESIA
KONSULTAN : PT. GLOBAL PROFEX SYNERGY (KSO)
: PT. WINSOLUSI KONSULTAN, SEECONS

UJI KUAT TEKAN BETON SILINDER


(SNI 1974 - 2011)

Luas Beban Konversi 28 hari Persen


Tanggal Umur Beton BERAT Tegangan Faktor
No Kode Sampel Slump Penampang Maks Cyl Spec Strength Cek
Mutu Koreksi
Dicor Dites (hari) (cm²) Gram (KN) (kg) (Mpa) (Mpa) (Mpa) (%)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
101.9367991845 10.197

1 BETON FC 10 Mpa - LC 9-May-2023 16-May-2023 7 FC 10 8 176.71 12339 230 23445.5 13.0 0.65 20.0 10 130.11
2 LC STA: 4+100 sd 4+450 7 Mpa 176.71 12312 210 21406.73 11.9 0.65 18.3 10 118.80
3 7 176.71 12288 220 22426.1 12.4 0.65 19.1 10 124.45
Rata-rata : 12313 12.4 19.1
1 BETON FC 10 Mpa - LC 13-May-2023 20-May-2023 7 FC 10 7.0 176.71 23228 230 23445.5 13.0 0.65 20.0 10 130.11
2 LC STA: 4+100 sd 4+450 7 Mpa 176.71 12231 225 22935.78 12.7 0.65 19.6 10 127.28
3 7 176.71 12335 235 23955.15 13.3 0.65 20.5 10 132.94
Rata-rata : 15931.33 13.0 20.0
1 kn = *1000/9,81

APPROVED By : CHECKED By : TESTED By :


PU.BINA MARGA KONSULTAN KONTRAKTOR

.......................................................... ........................................................... ................................................................


Pengawas Lap Lab .Tech Quality Control / Lab
PROYEK : PRESERVASI JALAN LINGKAR TIMUR PRABUMULIH
KONTRAKTOR : PT. SENECA INDONESIA
KONSULTAN : PT. GLOBAL PROFEX SYNERGY (KSO)
: PT. WINSOLUSI KONSULTAN, SEECONS

UJI KUAT TEKAN BETON SILINDER


(SNI 1974 - 2011)

Luas Beban Konversi 28 hari Persen


Tanggal Umur Beton BERAT Tegangan Faktor
No Kode Sampel Slump Penampang Maks Cyl Spec Strength Cek
Mutu Koreksi
Dicor Dites (hari) (cm²) Gram (KN) (kg) (Mpa) (Mpa) (Mpa) (%)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
101.9367991845 10.197

1 BETON FC 10 Mpa - LC 8-May-2023 15-May-2023 7 FC 10 7.5 176.71 12344 200 20387.4 11.3 0.65 17.4 10 113.14
2 LC STA: 4+100 sd 4+450 7 Mpa 176.71 12452 225 22935.78 12.7 0.65 19.6 10 127.28
3 7 176.71 12279 220 22426.1 12.4 0.65 19.1 10 124.45
Rata-rata : 12358.33 12.2 18.7
1 BETON FC 10 Mpa - LC 15-May-2023 22-May-2023 7 FC 10 7.0 176.71 12332 230 23445.5 13.0 0.65 20.0 10 130.11
2 LC STA: 4+100 sd 4+450 7 Mpa 176.71 12231 225 22935.78 12.7 0.65 19.6 10 127.28
3 7 176.71 12335 235 23955.15 13.3 0.65 20.5 10 132.94
Rata-rata : 12299.33 13.0 20.0
1 kn = *1000/9,81

APPROVED By : CHECKED By : TESTED By :


PU.BINA MARGA KONSULTAN KONTRAKTOR

.......................................................... ........................................................... ................................................................


Pengawas Lap Lab .Tech Quality Control / Lab
PROYEK : PRESERVASI JALAN LINGKAR TIMUR PRABUMULIH
KONTRAKTOR : PT. SENECA INDONESIA
KONSULTAN : PT. GLOBAL PROFEX SYNERGY (KSO)
: PT. WINSOLUSI KONSULTAN, SEECONS

UJI KUAT TEKAN BETON SILINDER


(SNI 1974 - 2011)

Luas Beban Konversi 28 hari Persen


Tanggal Umur Beton BERAT Tegangan Faktor
No Kode Sampel Slump Penampang Maks Cyl Spec Strength Cek
Mutu Koreksi
Dicor Dites (hari) (cm²) Gram (KN) (kg) (Mpa) (Mpa) (Mpa) (%)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
101.9367991845 10.197

1 BETON FC 10 Mpa - LC 7-May-2023 14-May-2023 7 FC 10 7.5 176.71 12344 200 20387.4 11.3 0.65 17.4 10 113.14
2 LC STA: 4+100 sd 4+450 7 Mpa 176.71 12452 225 22935.78 12.7 0.65 19.6 10 127.28
3 7 176.71 12279 220 22426.1 12.4 0.65 19.1 10 124.45
Rata-rata : 12358.33 12.2 18.7
1 BETON FC 10 Mpa - LC 13-May-2023 20-May-2023 7 FC 10 7.0 176.71 23228 230 23445.5 13.0 0.65 20.0 10 130.11
2 LC STA: 4+100 sd 4+450 7 Mpa 176.71 12231 225 22935.78 12.7 0.65 19.6 10 127.28
3 7 176.71 12335 235 23955.15 13.3 0.65 20.5 10 132.94
Rata-rata : 15931.33 13.0 20.0
1 kn = *1000/9,81

APPROVED By : CHECKED By : TESTED By :


PU.BINA MARGA KONSULTAN KONTRAKTOR

.......................................................... ........................................................... ................................................................


Pengawas Lap Lab .Tech Quality Control / Lab
PROYEK : PRESERVASI JALAN LINGKAR TIMUR PRABUMULIH
KONTRAKTOR : PT. SENECA INDONESIA
KONSULTAN : PT. GLOBAL PROFEX SYNERGY, (KSO)

: PT. WINSOLUSI KONSULTAN , SEECONS

SUMMARY
COMPRESSIVE STRENGTH TEST
(SNI .1974 - 2011 )

PEKERJAAN : BETON MUTU = FC 10 Mpa


LOKASI : LEAN CONCRETE ( Untuk Rigid )
PERIODE : 26 April sd 25 Mei 2023

LOKASI COR TANGGAL TANGGAL AVERAGE (Mpa) Specification Persen


NO L/R REMARK
STA COR TEST 7 Hr 28 Hr (Mpa) Strength (%)

1 4+100 sd 4+450 R 7-May-23 14-May-23 12.2 - 10 122%


5-Jun-23 - 22.93 10 229.3

2 4+100 sd 4+450 R 8-May-23 15-May-23 12.2 - 10 122.0


6-Jun-23 - 23.11 10 231.1

3 4+100 sd 4+450 R 9-May-23 16-May-23 12.4 - 10 124.0


7-Jun-23 - 10 0.0

4 4+900 sd 5+050 R 10-May-23 17-May-23 12.6 - 10 126.0


8-Jun-23 - 10 0.0

5 4+900 sd 5+050 R 11-May-23 18-May-23 13.1 - 10 131.0


9-Jun-23 - 10 0.0

6 5+600 sd 5+825 R 12-May-23 16-May-23 12.2 - 10 122.0


10-Jun-23 - 10 0.0

7 5+600 sd 5+825 R 13-May-23 17-May-23 12.2 - 10 122.0


11-Jun-23 - 10 0.0

8 5+050 sd 5+250 R 14-May-23 18-May-23 12.4 - 10 124.0


12-Jun-23 - 10 0.0

Disetujui Oleh Diperiksa Oleh : Dikerjakan Oleh :


PU. BINA MARGA KONSULTAN KONTRAKTOR

S U A N D I , ST A. MAULANA
Pengawas Lap Quality Engineer Quality Engineer