You are on page 1of 12

CALCULATION NOTE

(SLAB AND BEAM SUPPORT SYSTEMS)

Figure-1. Slab support systems

Prepared by Voek Pitou (Technical Manager) Pg. 1


1. Plywood Checking

40 80 Plywood 18mm thick.

RC Slab

400 400

Property

No. Items Geometry Modulus Strength


Elasticity (E)
1. Concrete Slab 250mm - -

2. Plywood 18mm 12000 12 Mpa

3. Wood 40x80 80mmx40mm 12000 12 Mpa

4. Steel Pipe ∅49 49mm, 210000 215 Mpa


t=3mm

a. Plywood checking

Concrete Self-weight

= × ×1
= 25 / × 0.25 ×1 = 6.25 / /

Live Load

=2 ⁄ =2 / /

Load Combination

= 1.35 × + 1.6
= 1.35 × 6.25 + 1.6 × 2 = 11.64 / /
= . / /

Prepared by Voek Pitou (Technical Manager) Pg. 2


= . / /

= =

Bending Strength

=
10
11.64 × 0.40
= = 0.18 ⁄
10
= . ⁄

Stress in Plywood
Plywood =
1
= ×
= 12
1
= = × 1000 × 18
12
Prepared by Voek Pitou (Technical Manager) Pg. 3
=

0.18 × 10 × 9
= = 3.33
486000
= . < = ,

Maximum displacement

×
=
185

11.64 × 400
= = 0.27
185 × 12000 × 486000
= .

=
270
400
= = 1.5
270
= . < = . ,

b. Main Purlin checking

∅ @1200mm

Prepared by Voek Pitou (Technical Manager) Pg. 4


Concrete Self-weight

= × ×
= 25 / × 0.25 × 0.40 = 2.50 /

Live Load

=2 ⁄ × 0.40 = 0.80 /

Load Combination

= 1.35 × + 1.6
= 1.35 × 2.5 + 1.6 × 0.80 = 4.65 /
= . /

= .

= =

Bending Strength

=
10
4.65 × 1.0
= = 0.46
10
= .

Stress in Main Purlin

Main Purlin =
1
= ×ℎ
12
1
= × 40 × 80
= 12
= .

=
0.46 × 10 × 40
= = 10.78
1706666.66

Prepared by Voek Pitou (Technical Manager) Pg. 5


= . < = . ,

Maximum displacement

×
=
185
4.65 × 1000
= = 1.23
185 × 12000 × 1706666.66
= .

=
270
1000
= = 3.70
270
= . < = . ,

c. Steel pipe support system checking

Steel Pipe-1:∅

(3-D model for steel


Steel Pipe-2:∅ pipe support)

Prepared by Voek Pitou (Technical Manager) Pg. 6


1. Steel pipe-1 support system checking

Concrete Self-weight

= ×
= 25 / × 0.25 = 6.25 /

Live Load

=2 ⁄
Load Combination

= 1.35 × + 1.6
= 1.35 × 6.25 + 1.6 × 2 = 11.63 /
= . /

(3-D model for steel pipe support)

Prepared by Voek Pitou (Technical Manager) Pg. 7


(Result of Bending Moment for Steel Pipes)

(Bending Moment For steel pipe-1)

=− .

Stress for Steel Pipe-1, ∅ , =

=
,

Prepared by Voek Pitou (Technical Manager) Pg. 8


, = 115159.00

0.57 × 10
= × 24.50 = 121.27
115159.00
= . < = ,

Maximum displacement

×
=
185
11.63 × 1.0 × 1000
= = 2.6
185 × 210000 × 115159.0

= . < = = = . , .

For more stability in site construction, double steel pipes are used during the
construction.
2. Steel pipe-2 support system checking

Bracing:∅

Steel Pipe-2:∅

(3-D model for steel pipe support)

Prepared by Voek Pitou (Technical Manager) Pg. 9


STEEL PIPE CHECKING-(1)
----------------------------------------------------------------------------------------------------------------------------------------
CODE: EN 1993-1:2005/AC:2009, Eurocode 3: Design of steel structures.
ANALYSIS TYPE: Member Verification
----------------------------------------------------------------------------------------------------------------------------------------
CODE GROUP:
MEMBER: CRITICAL PIPE POINT: 2 COORDINATE: x = 0.19 L = 0.60
m
----------------------------------------------------------------------------------------------------------------------------------------
LOADS:
Governing Load Case: 4 steel pipe model (1+2)*1.35+3*1.60
----------------------------------------------------------------------------------------------------------------------------------------
MATERIAL:
S 215 fy = 215.00 MPa
----------------------------------------------------------------------------------------------------------------------------------------

SECTION PARAMETERS: PIPE D49MM


h=4.9 cm gM0=1.00 gM1=1.00
Ay=2.76 cm2 Az=2.76 cm2 Ax=4.34 cm2
tw=0.3 cm Iy=11.52 cm4 Iz=11.52 cm4 Ix=23.03 cm4
Wply=6.36 cm3 Wplz=6.36 cm3
----------------------------------------------------------------------------------------------------------------------------------------
INTERNAL FORCES AND CAPACITIES:
N,Ed = 12.00 kN My,Ed = -0.00 kN*m Mz,Ed = -0.00 kN*m Vy,Ed = 0.00 kN
Nc,Rd = 93.21 kN My,Ed,max = -0.01 kN*m Mz,Ed,max = -0.00 kN*m Vy,c,Rd = 34.26 kN
Nb,Rd = 20.78 kN My,c,Rd = 1.37 kN*m Mz,c,Rd = 1.37 kN*m Vz,Ed = -0.00 kN
MN,y,Rd = 1.32 kN*m MN,z,Rd = 1.32 kN*m Vz,c,Rd = 34.26 kN
Class of section = 1
----------------------------------------------------------------------------------------------------------------------------------------

LATERAL BUCKLING PARAMETERS:


----------------------------------------------------------------------------------------------------------------------------------------
BUCKLING PARAMETERS:

About y axis: About z axis:


Ly = 3.20 m Lam_y = 2.00 Lz = 3.20 m Lam_z = 2.00
Lcr,y = 3.20 m Xy = 0.22 Lcr,z = 3.20 m Xz = 0.22
Lamy = 196.34 kyy = 1.51 Lamz = 196.34 kyz = 1.34
----------------------------------------------------------------------------------------------------------------------------------------
VERIFICATION FORMULAS:
Section strength check:
N,Ed/Nc,Rd = 0.13 < 1.00 (6.2.4.(1))
(My,Ed/MN,y,Rd)^ 2.00 + (Mz,Ed/MN,z,Rd)^2.00 = 0.00 < 1.00 (6.2.9.1.(6))
Vy,Ed/Vy,c,Rd = 0.00 < 1.00 (6.2.6.(1))
Vz,Ed/Vz,c,Rd = 0.00 < 1.00 (6.2.6.(1))
Global stability check of member:
Lambda,y = 196.34 < Lambda,max = 210.00 Lambda,z = 196.34 < Lambda,max = 210.00 STABLE
N,Ed/(Xy*N,Rk/gM1) + kyy*My,Ed,max/(XLT*My,Rk/gM1) + kyz*Mz,Ed,max/(Mz,Rk/gM1) = 0.59 < 1.00
(6.3.3.(4))
N,Ed/(Xz*N,Rk/gM1) + kzy*My,Ed,max/(XLT*My,Rk/gM1) + kzz*Mz,Ed,max/(Mz,Rk/gM1) = 0.59 < 1.00

Prepared by Voek Pitou (Technical Manager) Pg.


10
(6.3.3.(4))
----------------------------------------------------------------------------------------------------------------------------------------
Section OK !!!

STEEL PIPE CHECKING-(2)


----------------------------------------------------------------------------------------------------------------------------------------
CODE: EN 1993-1:2005/AC:2009, Eurocode 3: Design of steel structures.
ANALYSIS TYPE: Member Verification
----------------------------------------------------------------------------------------------------------------------------------------
CODE GROUP:
MEMBER: CRITICAL PIPE POINT: 2 COORDINATE: x = 0.19 L = 0.60
m
----------------------------------------------------------------------------------------------------------------------------------------
LOADS:
Governing Load Case: 4 steel pipe model (1+2)*1.35+3*1.60
----------------------------------------------------------------------------------------------------------------------------------------
MATERIAL:
S 215 fy = 215.00 MPa
----------------------------------------------------------------------------------------------------------------------------------------

SECTION PARAMETERS: PIPE D49MM


h=4.9 cm gM0=1.00 gM1=1.00
Ay=2.76 cm2 Az=2.76 cm2 Ax=4.34 cm2
tw=0.3 cm Iy=11.52 cm4 Iz=11.52 cm4 Ix=23.03 cm4
Wply=6.36 cm3 Wplz=6.36 cm3
----------------------------------------------------------------------------------------------------------------------------------------
INTERNAL FORCES AND CAPACITIES:
N,Ed = 2.82 kN My,Ed = 0.00 kN*m Mz,Ed = 0.00 kN*m Vy,Ed = -0.01 kN
Nc,Rd = 93.21 kN My,Ed,max = 0.14 kN*m Mz,Ed,max = 0.16 kN*m Vy,c,Rd = 34.26 kN
Nb,Rd = 20.78 kN My,c,Rd = 1.37 kN*m Mz,c,Rd = 1.37 kN*m Vz,Ed = 0.00 kN
MN,y,Rd = 1.36 kN*m MN,z,Rd = 1.36 kN*m Vz,c,Rd = 34.26 kN
Class of section = 1
----------------------------------------------------------------------------------------------------------------------------------------

LATERAL BUCKLING PARAMETERS:


----------------------------------------------------------------------------------------------------------------------------------------
BUCKLING PARAMETERS:

About y axis: About z axis:


Ly = 3.20 m Lam_y = 2.00 Lz = 3.20 m Lam_z = 2.00
Lcr,y = 3.20 m Xy = 0.22 Lcr,z = 3.20 m Xz = 0.22
Lamy = 196.34 kzy = 0.70 Lamz = 196.34 kzz = 1.09
----------------------------------------------------------------------------------------------------------------------------------------
VERIFICATION FORMULAS:
Section strength check:
N,Ed/Nc,Rd = 0.03 < 1.00 (6.2.4.(1))
(My,Ed/MN,y,Rd)^ 2.00 + (Mz,Ed/MN,z,Rd)^2.00 = 0.00 < 1.00 (6.2.9.1.(6))
Vy,Ed/Vy,c,Rd = 0.00 < 1.00 (6.2.6.(1))
Vz,Ed/Vz,c,Rd = 0.00 < 1.00 (6.2.6.(1))
Global stability check of member:
Lambda,y = 196.34 < Lambda,max = 210.00 Lambda,z = 196.34 < Lambda,max = 210.00 STABLE
N,Ed/(Xy*N,Rk/gM1) + kyy*My,Ed,max/(XLT*My,Rk/gM1) + kyz*Mz,Ed,max/(Mz,Rk/gM1) = 0.33 < 1.00
(6.3.3.(4))
N,Ed/(Xz*N,Rk/gM1) + kzy*My,Ed,max/(XLT*My,Rk/gM1) + kzz*Mz,Ed,max/(Mz,Rk/gM1) = 0.34 < 1.00

Prepared by Voek Pitou (Technical Manager) Pg.


11
(6.3.3.(4))
----------------------------------------------------------------------------------------------------------------------------------------
Section OK !!!