You are on page 1of 31

ENVIRONMENTAL IMPACT ASSESSMENT

&
ENVIRONMENTAL MANAGEMENT PLAN

THINDIVANAM INDUSTRIAL PARK


Pelakuppam, Kollar and Venmaniyathur
Tindivanam Taluk
Villupuram District
TAMIL NADU- 621 109

ToR Letter No.SEIAA-TN/F.No.6497/2018/8(b)/ToR-506/2018 Dated: 16.07.2018


1st SEAC Meeting held on 16.05.2018

PROJECT PROPONENT

State Industries Promotion Corporation of Tamilnadu Limited


CHENNAI-600 008
TINDIVANAM INDUSTRIAL PARK
 All General Engineering units such as fabrication, machining, forging,
castings etc.,
 Auto components Industries.
 Food Processing Industries.
 Packaging units.
 Any Other industries that are not in the purview of EIA Notification,2006

SIPCOT/GoTN
TINDIVANAM INDUSTRIAL PARK

Neither A nor B Category Industries


291.60.50 Ha
50 Ha < 500 Ha

8(b) B1
as per the EIA Amendment Notification of MoEF & CC
dated 22/12/2009.

SIPCOT/GoTN
TINDIVANAM INDUSTRIAL PARK

Project Location : Pelakuppam, Kollar and Venmaniyathur


Tindivanam Taluk
Villupuram District
Tamil Nadu – 621 109

Area : 291.60.50 Ha

Geological Location

Latitude : 120 14’ 21.91”N to 120 14’ 28.51”N


Longitude : 790 36’ 30.92”E to 790 37’ 37.20”E

SIPCOT/GoTN
PROJECT AREA
291.60.50 Hectares

SIPCOT/GoTN
KEY MAP
To Vandhavasi 35 KM

To Chennai 120 KM (NH-45)


NH-66 N
790 36’ 30.92”E 790 37’ 37.02”E

120 15’ 28.51”N

120 15’ 28.51”N


To Gingee 12 KM (NH-66)

120 14’ 21.91”N

120 14’ 21.91”N


790 36’ 30.92”E 790 37’ 37.02”E

Longitude: 790 36’ 30.92”E to 790 37’ 37.02”E


Latitude : 120 14’ 21.91”N to 120 15’ 28.51”N

To Marakkanam-27 KM
SH-134

To Pondicherry-26 KM
NH-66

Scale: 1:50,000
To Villupuram-30 KM
NH-45

SIPCOT/GoTN
N
BUDGETARY ESTIMATE

INR 300 Crores


SUMMARY OF LAND –USE PATTERN
291.60.50 Ha
S.No. Purpose/Activity Extent of Percentage
Land
(in ac) (in Ha)
1 Plot Area/Member Industries 482.36 195.29 72.84%
2 Roads and Storm water drainage 33.49 13.56 5.06%
3 Common amenities 10.79 4.37 1.63%
4 Commercial purpose 36.00 14.57 5.44%
5 Green Belt outside plot area 66.22 26.81 10.00%
6 Green Belt along roadside 8.67 3.51 1.31%
7 Solid Waste Area 24.70 10.00 3.73%
Total Developed Area 662.23 268.11 100.00%
Water Bodies 58.02 23.49
Total IP Area 720.25 291.60
GREEN BELT DEVELOPMENT
1 - by Member Industries (30% of the plot 144.71 58.59 21.85%
area allotted to Member Industries)

2 In OSR 66.22 26.81 10.00%


3 along the Road side and central meridian 8.67 3.51 1.31%

Total 219.60 88.91 33.16%


PROJECT IMPACT MAP
(10KM RADIUS)
To Vandhavasi 35 KM

To Chennai 120 KM (NH-45)


N
NH-66
790 36’ 30.92”E 790 37’ 37.02”E

120 15’ 28.51”N

120 15’ 28.51”N


To Gingee 12 KM (NH-66)

120 14’ 21.91”N

120 14’ 21.91”N


790 36’ 30.92”E 790 37’ 37.02”E

Longitude: 790 36’ 30.92”E to 790 37’ 37.02”E


Latitude : 120 14’ 21.91”N to 120 15’ 28.51”N

To Marakkanam-27 KM
SH-134

To Pondicherry-26 KM
NH-66

To Villupuram-30 KM Scale: 1:50,000


NH-45

SIPCOT/GoTN
PROJECT IMPACT MAP
Google Imagery (10KM RADIUS)
To Vandhavasi 35 KM

To Chennai 120 KM (NH-45)


NH-66 N
790 36’ 30.92”E 790 37’ 37.02”E

120 15’ 28.51”N

120 15’ 28.51”N


To Gingee 12 KM (NH-66)

120 14’ 21.91”N

120 14’ 21.91”N


790 36’ 30.92”E 790 37’ 37.02”E

Longitude: 790 36’ 30.92”E to 790 37’ 37.02”E


Latitude : 120 14’ 21.91”N to 120 15’ 28.51”N

To Marakkanam-27 KM
SH-134

To Pondicherry-26 KM
NH-66

To Villupuram-30 KM Scale: 1:50,000


NH-45

SIPCOT/GoTN
RAW IMAGE – LISS-III

SIPCOT/GoTN
GEOMORPHOLOGY MAP

Project Site

SIPCOT/GoTN
LANDUSE, LAND COVER MAP (20X20 km)

Project Site

SIPCOT/GoTN
LINEAMENT MAP

SIPCOT/GoTN
CONTOUR MAP

SIPCOT/GoTN
AMBIENT AIR QUALITY

Sampling
S.No Location PM2.5 PM10 SO2 NOX
Stations

1 A1 Project location 24.85-26.86 35.50-38.00 5.65-6.34 7.15-8.45


2 A2 Sandhaimedu 19.95-20.55 35.50-37.30 4.32-6.02 6.55-6.95

3 A3 Pattanam 19.65-20.45 34.50-37.10 4.22-5.89 7.69-7.85

4 A4 Pelakuppam 19.20-20.82 33.90-37.80 3.58-4.99 6.12-7.89


5 A5 Muttiyur 19.22-21.85 36.50-38.00 4.25-5.10 6.85-7.95
6 A6 Salai 19.90-25.60 35.50-38.30 4.65-6.21 6.65-7.85

7 A7 Kattusiviri 21.70-24.60 34.75-35.80 4.00-5.20 7.15-8.88

8 A8 Ural 21.00-24.89 34.90-36.85 5.10-6.09 6.95-8.15

9 A9 Ayyanthoppu 21.50-24.70 34.50-37.00 4.08-5.99 6.55-7.85

10 A10 Tindivanam 20.80-24.20 35.50-38.30 5.00-6.10 6.90-7.05

NAAQ Standards 60 100 80 80

SIPCOT/GoTN
AMBIENT NOISE LEVEL
Day Time Night Time dB(A) standard
Stations Max. Min. Avg. Max. Min. Avg. Day Night
dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) time time
N1 33.40 27.65 30.20 30.10 29.90 29.50 55 45
N2 31.50 30.90 31.45 30.40 29.50 28.45 55 45
N3 36.90s 30.60 32.80 32.10 30.70 30.40 55 45
N4 35.90 31.50 32.90 31.95 29.70 32.16 55 45
N5 33.20 30.60 32.90 30.20 31.20 30.70 55 45
N6 34.40 31.75 32.50 31.25 31.40 29.60 55 45
N7 31.70 29.90 31.80 32.30 31.50 30.10 55 45
N8 34.20 32.40 33.80 30.50 32.40 30.96 55 45
N9 34.50 30.20 32.80 30.65 29..90 30.20 55 45
N10 32.00 29.80 31.40 31.47 30.75 30.10 55 45

SIPCOT/GoTN
WATER ENVIRONMENT
SUB SURFACE WATER SOURCES
Tolerance
Quality Parameter W1 W2 W3 W4 W5
limits
PH at 25°C 6.82 6.90 7.00 7.10 6.80 6.5-8.5
Turbidity (NTU) 1.8 2.2 1.9 2.0 2.1 10
Total Dissolved Solids, mg/l 460 390 380 440 480 500
Total Suspended Solids,
12 15 16 18 10 -
mg/l
Total Hardness as Ca Co3 240 250 265 285 200 200
Conductivity uS/cm 565 525 530 490 520 -
Sulphates as SO4, mg/l 55 45 35 55 45 200
Chloride as Cl, mg/l 180 205 220 230 210 250
Sodium as Na, mg/l 60 95 70 65 42 -
Calcium as Ca, mg/l 72 86 55 75 35 75
Magnesium as Mg, mg/l 25 30 25 35 20 30
Potassium as K, mg/l - - - - - -
Fluoride as F, mg/l 0.80 1.15 1.10 1.30 1.20 1.0
Dissolved Phosphate as PO4,
- - 0.01 - 0.01 -
mg/l
10.5 24.5 20.5 25.1
Nitrates as NO3, mg/l 9.20 45
0 0 0 0
Aluminum as Al, mg/l - - - 0.05 - -
Manganese as Mn, mg/l 0.10 0.05 0.05 0.01 0.02 -
Iron as Fe, mg/l 0.01 0.10 0.11 0.15 0.05 0.3
Ammonical Nitrogen, mg/l 35 29 32 45 35 -
Dissolved Oxygen, mg/l 4.0 5.5 6.1 5.0 5.5 -
Biological BOD3, mg/l 1.5 2.7 2.0 1.0 1.5 -
COD, mg/l 20.5 15.0 30.0 40.5 28.1 -
SIPCOT/GoTN
WATER ENVIRONMENT
SURFACE WATER SOURCES
Tolerance
Quality Parameter W6 W7 W8 W9 W10
limits
pH at 25°C 7.61 7.20 7.30 6.90 6.90 8.5

Turbidity (NTU) 13.6 14.5 18.1 20.9 20.6 10


204 201 157 144
Total Dissolved Solids, mg/l 2220 1500
0 0 0 0
Total Suspended Solids, mg/l 50 60 45 36 49 -
411
Total Hardness as Ca Co3 480 440 380 390 -
0
Conductivity uS/cm 990 810 795 925 880 -
Sulphates as SO4, mg/l 85 70 75 65 85 400
Chloride as Cl, mg/l 315 288 325 320 302 600

Fluoride as F, mg/l 0.94 1.25 1.15 1.08 1.54 1.5


Dissolved Phosphate as PO4,
- - - - -
mg/l
Iron as Fe, mg/l 0.19 0.17 0.16 0.17 0.29 0.3

Manganese as Mn, mg/l - - - - -


Potassium as K, mg/l - - - - -
Sodium as Na, mg/l 75 58 85 106 120 -
Calcium as Ca, mg/l 55 76 82 77 73 -
12.8 13.5 13.4 22.3
Nitrates as NO3, mg/l 21.70 -
5 4 0 5
Aluminium as Al, mg/l - - - - - -
Magnesium as Mg, mg/l 7.60 10.0 11.5 16.3 15.0 -

Ammonical Nitrogen, mg/l 0.14 0.15 0.45 0.14 0.55 -

Dissolved Oxygen, mg/l 5.0 5.2 4.9 4.7 5.1 -


SIPCOT/GoTN
Biological BOD3, mg/l 16 10 11 20 19 -
COD, mg/l 50 55 55 65 65 -
WATER DEMAND

4 MLD
Exclusive TTRO
( using Treated Domestic Wastewater from Tindivanam)

SIPCOT/GoTN
WATER BALANCE
SIPCOT Industrial Park
4 MLD
720.56 Acres @ 5000 lit/day
3.65 MLD
(Say 4 MLD)

Recycle-
2MLD

(ETP/STP)

75% 25%
On Moisture removal/drying
3 MLD 1 MLD Disposal as Sludge

1MLD
For Green belt Development
and Washing

SIPCOT/GoTN
WASTE WATER MANAGEMENT

Responsibility of Industries

Independent Effluent Treatment Plants


Physico-Chemical, Media Filtration followed by Membrane
Filtration
Operated as Zero Liquid Discharge Plants to reclaim
water for reuse/recycle
SOLID WASTE MANAGEMENT

Non-Hazardous
Composting/Mechanical Systems & Local Body Services
Hazardous
Off Site TSDF
Gummidipoondi, Chennai

SIPCOT/GoTN
GREEN BELT DEVELOPMENT

All open spaces and along the sides of all internal


roads

RAIN WATER HARVESTING STRUCTURES

Rain water collection Systems - All building Roofs


Recharge wells in strategic Points- 10 Locations

SIPCOT/GoTN
RENEWABLE ENERGY

Solar Energy
- Street Lightings by SIPCOT at artillery road junctions
- Solar Water Heating in Guest Houses

SIPCOT/GoTN
PARKING

Covered/Un covered Open Parking

100 Cars
5000 Two Wheelers
100 Cargo/Heavy Vehicles

SIPCOT/GoTN
CORPORATE SOCIAL RESPONSIBILITY

Support for

Green Belt Development in the adjoining villages


Community Health Surveillance Plan
Job Opportunity for local community
Special Training on latest Garment Manufacturing Techniques
Special Training on Garment Export opportunities

SIPCOT/GoTN
Corporate Environment Responsibility

1.5 % of the Capex – 3 Crores

( For infrastructure creation for drinking water supply,


sanitation, health, education, skill development,
roads, cross drains, electrification including solar
power, solid waste management facilities, scientific
support and awareness to local farmers to increase
yield of crop and fodder, rain water harvesting, soil
moisture conservation works, avenue plantation,
plantation in community areas and any other activity
as preferred in EC or subsequently in Special
Conditions of CTE/CTO from State PCB )

SIPCOT/GoTN
PROTOCOL OF ENVIRONMENTAL CELL
SIPCOT INDUSTRIAL PARK
TINDIVANAM

HEAD
(PROJECT MANAGER, SIPCOT)

ENVIRONMENTAL ENGINEER

Officer I Officer II Officer III Officer IV Officer V


Environmental Standards Green belt development Emergency Management Cell Statutory approvals from Social & Health
Status of member industries Rainwater Harvesting Structures Personal Safety Systems TNPCB/LBs/EB/Forests/ Public Grievances
(monitoring/documentation) Strom water Drainage Disaster Management cell CPCB/MoEF surveillance
Occupational Health Programmers

SIPCOT/GoTN
DISCLOSURE OF CONSULTANTS

Centre for Environment, Health and Safety


Annamalai University

Accredited under NABET


QUALITY COUNCIL OF INDIA.
&
ITCOT Consulting and Services Limited
Chennai

SIPCOT/GoTN

You might also like