FRAMELESS GLAZING USING

SPIDER FITTINS & PATCH FITTINGS


• TOUGHENED GLASS IS 5 TIMES STRONGER THAN ORDINARY
GLASS. (AS SRONG AS BLOCKBOARD)

• SINGLE HT. SHEETS OF TOUGHENED GLASS (FOR SHOP


WINDOWS) CAN BE BUTTED AT THEIR VERTICAL EDGES.

• 12 MM THICK VERTICAL FINS AT JUNCTION OF GLASS CAN BE


FIXED TO GIVE LATERAL STABILITY FOR THE GLASS.

• THE JOINTS CAN BE BONDED WITH SILICONE SEALENT.


PARIS SCIENCE MUSEUM
PARIS SCIENCE MUSEUM
RENAULT DISTRIBUTION CENTER
SUSPENDED MULTI PANEL ASSEMBLIES
• GLASS WALLS UPTO 75 FEET HT (23meters) AND UNLIMETED LENGTH CAN BE MADE USING
12 mm THICK PANELS AND 19mm MULLIONS / FINS OUT OF TOUGHENED FLOAT GLASS.

• OWING TO LARGE SIZE, THE PANES HAVE TO BE MECHANICALLY JOINED TOGETHER AT


CORNERS USING PATCH FITTINGS.

• THE PANELS SUSPENDED FROM TOP AND PERIMETER EMBEDED INTO THE AL. CHANNEL
ALLOWS THE MOVEMENT OF THE ASSEMBLY INDIPENDENTLY OF THE STRUCTURE AND
ACCOMMODATE TOLARENCE BETWEEN HIGHLY ACCURATE GLASS ASSEMBLIES AND LESS
ACCURATE MAIN STRUCTURE.

• WIND LOAD RESISTED BY RC STRUCTURE, 19 mm TH GLASS FINS, OR SPACE FRAME


SUPPORTED AT THE JUNCTION OF GLASS PANES.

• FIBER GASKET AND PLASTIC BUSHES ELIMINATE CONTACT BETWEEN METAL AND GLASS.

• HORIZONTAL AND VERTICAL BUTT JOINTS SEALED BY SILICONE SEALENT


SIZES OF GLASS
 SIZES OF TOUGHENED GLASS : 3.6X2.1M; 4X2M; 4.2X2M ETC.

THE SIZE DEPENDS ON:


 ALLOWABLE DEFLCTION & STRESSES.
 SIZE OF TOUGHENING BATH.
 GOATING OR TINTING OF GLASS
ETC.
THUMB RULE FOR FIXING OF BOLTS
 THUMB RULE FOR FIXING OF BOLTS IN SHELTERED URBAN AREAS:

2M sq PANELS – 4 NOS (ONE AT EACH CORNER)


2-3.5 sqm PANELS – 6 NOS.
>3.5 sqm PANELS – 8 NOS.
BK/BLOCK WALL SHIMS

12mm PLASTER

25mm MIN COVER

SILICONE SEALANT AND NEOPRENE GUIDES

10 or 12 MM TOUGHENED GLASS

50X30 AL. CHANNEL(2mm WALL THICKNESS)


FIXING

PERIMETER DETAIL OF SUSPENDED GLASS ASSEMBLY


TWO –POINT
SUSPENSION EDGE OF SLAB /BEAM
HANGER(12)

GASKET

(80 ht)

(4)
ROOT ANGLE TO
HEAD OF MULLION

(2)
GASKET

PATCH FITTING(100X100)

GLASS FIN(300X19)

SUSPENDED GLAZING (50X50)


(MULTI PANEL ASSEMBLIES)
GLASS FIN(19mm)

TEMPERED GLASS PANELS


(12mm) SLIDING JOINT

STAINLESS STEEL BOLTS


WITH FIBER
GASKETS/PLASTIC BUSHES

PATCH FITTING(100X100mm)

ELASTOMERIC SEALANT JOINTING


EDGES OF GLASS PANELS

PATCH FITTING FOR FOUR PANELS


& GLASS FIN JUNCTION.
GLASS WALL LATERALLY SUPPORTED BY FINS
GROUND BASED MULTI PANEL ASSEMBLIES
• THE PANEL ASSEMBLIES ARE SOPPORTED FROM GROUND
UP TO 9 TO 10M.
• THE WALL IS LATERALLY SUPPORTED BY FINS OR
STRUCTURAL SYSTEM.
• GLAZING IS RIGIDLY FIXED IN THE MIDDLE & CANTILEVERS
AT TOP & BOTTOM
OR
THE ASSEMBLY CAN BE RIGIDLY FIXED AT
BOTTOM & SLIDING JOINT AT TOP.

• PATCH FITTING PLATE SPLIT VERTICALLY TO


ACCOMMODATE DIFFERENT FACES OF ANGLES & TO
ALLOW DIFFERENTIAL MOVEMENT.
AL. SHEET FLASHING

AL. CLAMPING STRIP WPC


BOLTED THROUGH
GLASS
RCC ROOF SLAB

MS SUPPORT PLATE FOR


SUSPENSION BOLT

SUSPENSION BOLT FIBRE GASKET FIN FIXINGS BOLTED


THROUGH SLABS

TREATED MS INTERNAL
CLAMPING STRIP

19mm CLEAR
TOUGHENED GLASS FIN

165X165mm PATCH FITTING VERTICALLY SPLIT


12mm TOUGHENED
GLASS

TYP. VIEW OF GROUND-BASED


MULTI PANEL ASSEMBLIES
SPIDER FITTINGS
• MEETS THE REQUREMENT OF MAXIMISING GLASS AREA IN A FACADE.
• THE FITTINGS ARE DESIGNED TO TRANSFER LOADS FROM GLASS TO LATERAL
STRUCTURAL SYSTEM.
• MAJOR CLASSIFICATION – (i) GLASS FIN SUPPORTED SYSTEM.
(ii) STEEL SUPPORTED SYSTEM.
• MANUFACTURED WITH STAINLESS STEEL (S-316) & ALUMINIUM.
• FINISHES: POLISHED,SATIN FINISHED & EPOXY PAINT.
• ALUMINIUM FITTINGS ARE LIGHT-WEIGHT, CORROSSION RESISTANT; SUITABLE FOR
LIGHT-WEIGHT DUTY.
• THE FITTINGS ARE PRODUCED IN 1,2,3,&4 ARMED FOR USING IN DIFFERENT
LOCATIONS IN GLASS PANES.
4 WAY SPIDER WITH FIN

200

94

(FIN THK)
VIEW

19
94
130

PLAN

44
20 dia
SIDE ELEVATION
ONTARIO CONVENTION CENTER
VIEW

PLAN

200

26 dia 56 dia 46 dia

2 WAY SPIDER WITHOUT FIN


c/c
SLOTS 9X18mm

c/c
HOLE 18mm DIA

ELEVATION DIAGONAL SECTION

SPIDER FITTING