Describe the Procedure to Build Control

Modules

Data Acquisition Control Module 1 ExperionPKS Control Execution Environment EXP04R201


Describe the Procedure to Build Control Modules July 13, 2020
Building Control Modules
Honeywell

• Objectives:

– Build and Edit Control Modules

– Load, Activate and Monitor Control Modules

– Explore Additional Control Builder Functions

Data Acquisition Control Module 2 ExperionPKS Control Execution Environment EXP04R201


July 13, 2020
Describe the Procedure to Build Control Modules
Building Control Modules
Honeywell

Sequentially numbered name


given by Control Builder

Blank CM

Data Acquisition Control Module 3 ExperionPKS Control Execution Environment EXP04R201


July 13, 2020
Describe the Procedure to Build Control Modules
Building Control Modules
Honeywell

Drag and
Drop

Data Acquisition Control Module 4 ExperionPKS Control Execution Environment EXP04R201


July 13, 2020
Describe the Procedure to Build Control Modules
Building Control Modules
Honeywell

Configure CM Parameters

Data Acquisition Control Module 5 ExperionPKS Control Execution Environment EXP04R201


July 13, 2020
Describe the Procedure to Build Control Modules
Building Control Modules
Honeywell

Configure Module
Parameters

Data entry
details will be
provided in the
Lab exercise

Data Acquisition Control Module 6 ExperionPKS Control Execution Environment EXP04R201


July 13, 2020
Describe the Procedure to Build Control Modules
Building Control Modules
Honeywell

Execution Period and Phase=Execution Cycle


The Execution Cycle
has 40 timing phases of
50 ms each

PHASE
0 0
1 2 3 4 5 6 7 8 9 10 11 12 37 38 39

1850 1950
0 50 100 150 200 250 300 350 400 450 500 550 600 1900 2000
TIME (mS)

Examples: A CM with a one second Execution Period (1000 ms)


with a Phase of 0 would execute at Phase 0 and again at Phase 20
--
A CM with an Execution Period of 200 milliseconds and a Phase of
1 will execute in cycles 1, 5, 9, ... 37

Data Acquisition Control Module 7 ExperionPKS Control Execution Environment EXP04R201


July 13, 2020
Describe the Procedure to Build Control Modules
Building Control Modules
Honeywell

CEE
Detail
Display

Data Acquisition Control Module 8 ExperionPKS Control Execution Environment EXP04R201


July 13, 2020
Describe the Procedure to Build Control Modules
Building Control Modules
Honeywell

Assigning Control Modules to the CEE


2

4
3
1 6

Data Acquisition Control Module 9 ExperionPKS Control Execution Environment EXP04R201


July 13, 2020
Describe the Procedure to Build Control Modules
Building Control Modules
Honeywell

Inserting Function Blocks

Data Acquisition Control Module 10 ExperionPKS Control Execution Environment EXP04R201


July 13, 2020
Describe the Procedure to Build Control Modules
Building Control Modules
Honeywell
Execution Order in CM

Data Acquisition Control Module 11 ExperionPKS Control Execution Environment EXP04R201


July 13, 2020
Describe the Procedure to Build Control Modules
Building Control Modules
Honeywell
Connecting Function Blocks

Not yet
connected

Data Acquisition Control Module 12 ExperionPKS Control Execution Environment EXP04R201


July 13, 2020
Describe the Procedure to Build Control Modules
Building Control Modules
Honeywell
Analog Loop CM
1
3 3

2
3 5

3
5

Data Acquisition Control Module 13 ExperionPKS Control Execution Environment EXP04R201


July 13, 2020
Describe the Procedure to Build Control Modules
Building Control Modules
Honeywell
Device Control CM

Expanded
to show
Function
Blocks
Inputs

Outputs

Logic/Interlocks

Data Acquisition Control Module 14 ExperionPKS Control Execution Environment EXP04R201


July 13, 2020
Describe the Procedure to Build Control Modules
Building Control Modules
Honeywell
Device Control Detail Display

2-State

Data Acquisition Control Module 15 ExperionPKS Control Execution Environment EXP04R201


July 13, 2020
Describe the Procedure to Build Control Modules
Building Control Modules
Honeywell
Loading Control Modules

1
3

Right-Click

Data Acquisition Control Module 16 ExperionPKS Control Execution Environment EXP04R201


July 13, 2020
Describe the Procedure to Build Control Modules
Building Control Modules
Honeywell
Loading Control Modules

Check the
appropriate boxes

Data Acquisition Control Module 17 ExperionPKS Control Execution Environment EXP04R201


July 13, 2020
Describe the Procedure to Build Control Modules
Building Control Modules
Honeywell
Activating Control Modules

Right-Click

Data Acquisition Control Module 18 ExperionPKS Control Execution Environment EXP04R201


July 13, 2020
Describe the Procedure to Build Control Modules
Building Control Modules
Honeywell
Monitoring/Chart Visualization

Scale Factor
Icon

Data Acquisition Control Module 19 ExperionPKS Control Execution Environment EXP04R201


July 13, 2020
Describe the Procedure to Build Control Modules
Honeywell

This page is intentionally blank.

Data Acquisition Control Module 20 ExperionPKS Control Execution Environment EXP04R201


July 13, 2020
Describe the Procedure to Build Control Modules
Describe Bulk Edit Parameters

Data Acquisition Control Module 21 ExperionPKS Control Execution Environment EXP04R201


Describe Bulk Edit Parameters July 13, 2020
Use Bulk Edit Parameters
Honeywell
•Objectives:
– Export Tags and parameters to Excel
– Modify parameters in Excel
– Read Parameters into Project

Data Acquisition Control Module 22 ExperionPKS Control Execution Environment EXP04R201


July 13, 2020
Describe Bulk Edit Parameters
Use Bulk Edit Parameters
Honeywell
• Bulk Edit Parameters
– Bulk Edit Parameters is a utility which allows you to change the value of multiple
parameters in a single operation by importing a prepared list of edits.

• Tools>Bulk Edit Parameters>Create Bulk Edit List

Data Acquisition Control Module 23 ExperionPKS Control Execution Environment EXP04R201


July 13, 2020
Describe Bulk Edit Parameters
Use Bulk Edit Parameters
Honeywell
Show all points button is used to populate the "Available Points" selection list
with the names of all points in the database.

Show all Points

Data Acquisition Control Module 24 ExperionPKS Control Execution Environment EXP04R201


July 13, 2020
Describe Bulk Edit Parameters
Use Bulk Edit Parameters
Honeywell

Select the points


and parameters

The selected points

The parameter(s)
to be modified

Data Acquisition Control Module 25 ExperionPKS Control Execution Environment EXP04R201


July 13, 2020
Describe Bulk Edit Parameters
Use Bulk Edit Parameters
Honeywell

Building the
Excel file

Browse to desired
output path

Select the output


file type

Save

Data Acquisition Control Module 26 ExperionPKS Control Execution Environment EXP04R201


July 13, 2020
Describe Bulk Edit Parameters
Use Bulk Edit Parameters
Honeywell

Open the created BulkEdit.xls file in Excel

• Edit the parameters


as necessary

Use the single quote


before numbers ‘100

Do not change or
add tag names.
Keep columns in order.

Data Acquisition Control Module 27 ExperionPKS Control Execution Environment EXP04R201


July 13, 2020
Describe Bulk Edit Parameters
Use Bulk Edit Parameters
Honeywell

Read Bulk Edit list

Select Update to
Monitor or Project
Select Start

Data Acquisition Control Module 28 ExperionPKS Control Execution Environment EXP04R201


July 13, 2020
Describe Bulk Edit Parameters