Professional Documents
Culture Documents
FUNCTION IN HOTELS
1
CONTENTS:
INTRODUCTION TO HOTEL
HOTEL AREAS
HOTEL ENTRANCES
RELATION BETWEEN SPACES
SITE REQUIREMENT
GROUND FLOOR
MEZZANINE FLOOR
TYPICAL FLOOR
2
INTRODUCTION
HOTEL RATING
3
INTRODUCTION
Amenities in addition to the facilities provided by a 5 star
hotel:
Speciality restaurant
Coffee shop
Lounge
Up scale public areas
Up scale guestrooms including premium furniture and
linen, bathrobes, slippers, safe, wet bar.
4
HOTEL AREAS DEFINED:
5
HOTEL AREAS DEFINED:
6
BUILDING BYE LAWS :
* THERE ARE TWO MAIN ENTRANCES IN A HOTEL:
7
BUILDING BYE LAWS :
LOBBIES FRONT
GUEST
OF THE
Lobbies BATHROOM
HOUSE
ADMINISTRATION GUEST ROOM
AREA CLOSET
GUEST
RESTAURANT ROOMS GUEST FLOOR
FACILITIES SERVICE SPACE
ELEVATOR BANQUETING
FACILITIES
GUEST FLOOR CORRIDOR
8
BUILDING BYE LAWS :
MECHANICAL LAUNDRY
FRONT OF
SPACES FACILITY
THE HOUSE
9
R E L AT I O N B E T W E E N S PA C E S :
10
11
PUBLIC AREAS:
Main Entrance
12
Main Lobby
RESTAURANT
13
MEZZANINE FLOOR:
Main restaurant,. 500m2
Kitchen, washbasin, w.c
Administration 5 * 16 m2 + services
Worker services and rest rooms
200m2
RESTAURANT
•It should have moveable furniture for flexibility of use.
•The kitchen store rooms , delivery points, dining room ,
toilets and other service areas should be well connected.
•Structural columns in the dining rooms are the best in the
middle of the group of tables or at the corner of the table.
•The minimum width of the escape routes should be 1.00 m
per 150 people.
•General walkways should be at least 1.10m with clearance
height of more than or equal to 2.1m .
•The window area should be 1/10th of the room area of the
dining room.
RESTAURANT
•It should have moveable furniture for flexibility of use.
•The kitchen store rooms , delivery points, dining room ,
toilets and other service areas should be well connected.
•Structural columns in the dining rooms are the best in the
middle of the group of tables or at the corner of the table.
•The minimum width of the escape routes should be 1.00 m
per 150 people.
•General walkways should be at least 1.10m with clearance
height of more than or equal to 2.1m .
•The window area should be 1/10th of the room area of the
dining room.
STAFF
GUEST
17
MEZZANINE FLOOR:
RESTAURANT
LONGUE
BANQUTE
STORAGE
LONGUE BAR
KITCHEN
18
MEZZANINE FLOOR:
HOTEL KITCHENS
Kitchen size is determined by the number of workstations,
the space required for equipment. the range of meals and
the extent of food preparation.
kitchen
•The kitchen should have a direct access to the restaurant
with double service doors between the dining and
kitchen.
•Seggregate storage for meat , fish and vegetables.
•Tiled wall sand non slippery floors.
•Separate washing areas.
•Separate Grocery areas.
19
MEZZANINE FLOOR:
20
MEZZANINE FLOOR:
21
MEZZANINE FLOOR:
22
MEZZANINE FLOOR:
ADMINISTRATION
2-ACCOUNTING
General office located near the front office to
have counting & deposits.
23
MEZZANINE FLOOR:
3-SALES & CATERING OFFICES
The fourth group, the sales & catering office,
is responsible for attracting group business
and servicing the meetings & banquets once
they are in the hotel.
SALES &
Their cluster include:- CATERING
1. Reception area.
2. Director of sales MEETING &
3. Sales representative OFFICES
4. Catering managers
5. Banquet manager
6. Banquet representative.
7. Convention service manager
8. Function book room
9. Secretaries
10. Other:- toilets, storage, etc.
24