Building Bye Laws | ARD-514
Submitted to : Submitted by :
Ar. Vishakha Verma MANISH SOOD
Dept. of Architecture 17615
NIT Hamirpur B.Arch. 9th
Sem
THESIS
PROJECT :
THESIS
PROJECT :
Site is located in
Residential Zone 1
Sources Considered for Bye
-Laws : Urban Development Authority (AUDA)
Ahmedabad
Revised Development Plan 2021 | AUDA
D1
Category
FSI PERMISSBLE
Floor Space Index /Floor Area Ratio
For example:
40 ft Road = 12 Road
Width of Internal Roads
:
Up to 6 m wide Roads,
Radius of
Road Curvature
= 3m
Road Side
Margins :
= 2.5 m
Margins b/w two
Buildings :
= 4.5 m
Rear & Side
Margins :
For Example, In my case for
residences Building Height will be
less than 16 m
Rear Margin
=3m
Side Margin
=3m
Basement
Regulations
:
Access Path:
1. Access path from the building‐unit to the building entry or the plinth - a minimum width of 1.8mts with an even surface
and devoid of steps.
2. a sloping access path - the gradient shall not be greater than 1:12.
3. Any difference between the road level and building‐unit level shall be accommodated within the building‐unit boundary.
Ramp Dimensions : Railing Dimensions
Stepped Approach:
• All circulation and service spaces such as • sloping roof, minimum clearance height shall be 2.2 mts
verandah, bathroom, washroom, toilet,
passage, puja room, store room and stair cabin • trussed roof, minimum clearance height (measured from the
- a minimum clearance height of 2.1 mts. floor level to the bottom of the tie beam) 2.8 mts.
Mezzanine : Loft :
• Loft of a maximum height of 1.2 mts may be
• Mezzanine floor - a minimum clear height of 2.1 mts which
allowed in a room at a minimum clear height of 2.1
may be allowed in a room at a minimum clear height of 2.1
mts from the finish floor level
mts from the finished floor level
• if the area does not exceed 30 % of the area of the
• (if the area does not exceed 30 % of the area of the
enclosed space.
enclosed space.)
Basement :
• For Basement, exclusively used for parking - minimum clear height of 2.8 mts, and maximum clear height of 4.5 mts.
• Provision for drainage or water supply shall not be permitted in the basement.
• Material used for construction of basement shall be fire resistant. Wood or any other combustible material shall not be
used as structural members of a basement.
• The ramps leading to loading and unloading space- minimum 6.0 mt width.
• The loading and unloading space shall be permitted on ground level or in first basement. And shall be considered
as a part of parking area
Ventilation of Bathrooms and Water Closets :
Signage :
• The size of lettering shall not be less than 20mm to enable easy legibility.