ABSTRACT
 
 THIS PAPER DEALS WITH PLANNING AND DESIGN OF AN HOSPITAL
BUILDING OF STILT+4. IN THIS PAPER, IT DEALS WITH THE DESIGN OF
AN EYE CARE HOSPITAL FOR 45 BEDS. THE STRUCTURE SHALL BE
BEING DESIGNED TO RESIST AND MUST BEAR ALL LOAD LIABLE TO
ACT ON IT AT SOME POINT OF ITS LIFESTYLES. IT SHALL ADDITIONALLY
SATISFY SERVICEABILITY REQUIREMENTS INCLUDING LIMITATIONS ON
DEFLECTION AND CRACKING. IN OUR PAPER, PLANNING IS DONE
USING AUTOCAD. DESIGN IS DONE USING IS 12433-2 CODE.
INTRODUCTION

HOSPITAL BUILDING MEANS ANY BUILDING USED OR DESIGNED TO AND


INTENDED TO BE USED FOR MEDICAL, SURGICAL, NURSING OR
CUSTODIAL CARE ON A 24 HOUR.
HOSPITALS ARE THE MOST COMPLEX OF BUILDING TYPES. EACH
HOSPITAL IS COMPRISED OF A WIDE RANGE OF SERVICES AND
FUNCTIONAL UNITS. THESE INCLUDE DIAGNOSTIC AND TREATMENT
FUNCTIONS, SUCH AS CLINICAL LABORATORIES, IMAGING, EMERGENCY
ROOMS, AND SURGERY; HOSPITALITY FUNCTIONS, SUCH AS FOOD
SERVICE AND HOUSEKEEPING
THIS PROJECT DEALS WITH PLANNING PHASE, ANALYSIS PHASE AND
THE DESIGN PHASE. ANY ENGINEERING STRUCTURE SHOULD SATISFY
THE FUNCTIONAL AND STRUCTURAL NEEDS, HAVE A SUFFICIENT
DEGREE OF PERFORMANCE, A REASONABLE COST AND SHOULD BE
AESTHETICALLY ATTRACTIVE. THE PURPOSE OF STRUCTURAL
ANALYSIS AND DESIGN IS TO ENABLE THE DESIGNERS TO DESIGN THE
STRUCTURE WITH ADEQUATE STRENGTH, STIFFNESS, AND STABILITY.
DESIGN IS DONE MANUALLY. THE ANALYSIS IS DONE BY MANUALLY
AND WE HAVE USED AUTOCAD FOR PLANNING.
HOSPITAL MUST MEET TWO BASIC FUNDAMENTAL NEEDS
MUST MEET THE NEEDS OF THE
PATIENT IT IS GOING TO SERVE
ADEQUATELY.
IT MUST BE IN A SIZE AND
PROPORTIONS WHICH THE OWNERS
OR PROMOTERS WILL BE ABLE TO
BUILD AND OPERATE.
BASIC OBJECTIVES WHICH ARE TO BE MET BY THE
HOSPITAL

Sound architectural plan


Economic viability
Effective community orientation
Quality patient care
PRINCIPLES OF HOSPITAL PLANNING

•PROTECTION FROM UNWANTED AND UNNECESSARY


DISTURBANCES IN ORDER TO HELP SPEEDY RECOVERY
•SEPARATION OF DISSIMILAR ACTIVITIES
•CONTROL – THE NURSES STATION SHOULD BE
POSITIONED STRATEGICALLY TO ENABLE PROPER
MONITORING OF VISITORS ENTERING AND LEAVING THE
WARD, INFANTS AND CHILDREN SHOULD BE PROTECTED
FROM THEFT AND INFECTION ETC.
•CIRCULATION- ALL THE DEPARTMENTS OF A HOSPITAL
MUST BE PROPERLY INTEGRATED.
PLANNING OF DEPARTMENTS

IN PATIENT DEPARTMENT-
PATIENT ROOM- THESE MAY BE PRIVATE/SEMI PRIVATE ROOMS
OR MULTIBED GENERAL WARDS. THEY SHOULD BE DESIGNED TO
BE SAFE AND AESTHETICALLY PLEASING SO AS TO ASSIST IN
QUICK RECOVERY OF PATIENT. THEY MUST CONTAIN SPACE FOR
EQUIPMENTS, STAFFS AND VARIOUS NEED OF THE PATIENT.
NURSES CONTROL STATION- SHOULD BE LOCATED AND
DESIGNED IN SUCH A WAY THAT THE NURSES CAN OBSERVE THE
PATIENT ROOM.
THE WORK AREA- RELATED TO HANDLING MATERIALS
NECESSARY FOR PATIENT CARE, MAINTAINING COMMUNICATION
AND RECORDS ETC.
SELECTION OF SITE

NEEDS OF THE COMMUNITY


EASE OF ACCESSIBILITY

RANGE OF SERVICES OFFERED

AVAILABILITY OF SPECIALISTS

AVAILABILITY OF TECHNOLOGY

REQUIREMENTS OF STAFF AND SERVICES


STILT FLOOR

 TOTAL SITE AREA


500 SQM
 SECURITY ROOM
AREA 14.77 SQM
 PARKING AREA 180
SQM
 SPACE FOR OXYGEN
ROOM 8.97SQM
 LIFT AREA 4.2 SQM
 RAMP AREA 19.5
SQM
HOSPITAL PLAN DETAILS
[ FIRST FLOOR ]

 NO’S CONSULTANT ROOM 3


• SIZE CONSULTANT ROOM 1:
4700*3000MM
• SIZE OF CONSULTANT ROOM 2
(MINOR) 3100*3300MM
• SIZE OF CONSULTANT ROOM 3
3100*4700MM
 PHARMACY ROOM 3000*4800MM
 ANTI ROOM 4600*1800MM
 PASSAGE 6000*6200MM
 PASSAGE 6100*5200MM
 WASH AREA 2300*2500MM
HOSPITAL PLAN DETAILS
[ SECOND, THIRD & FOURTH FLOOR ]

 NO’S OPERATION THEATERS 3


• SIZE OPERATION THEATER 1:
4700*3000MM
• SIZE OF OPERATON THEATER
2 (MINOR) 3100*3300MM
• SIZE OF OPRATON THEATER 3
3100*4700MM
 INJECTON ROOM 3000*4800MM
 ANTI ROOM 4600*1800MM
 FEMALE WARD 6000*6200MM
 MALE WARD 6100*5200MM
 WASH AREA 2300*2500MM
 WAITING AREA 2300*3100MM
SECTION
COLUMN DESIGN
 NO OF C1F1 COLUMNS :1
• SIZE OF FOOTING 2700*2700 MM.
 NO OF C2F2 COLUMNS :1
• SIZE OF FOOTING 2400*2400 MM.
 NO OF C3F3 COLUMNS :1
• SIZE OF FOOTING 2300*2300 MM.
 NO OF C4F4 COLUMNS :3
• SIZE OF FOOTING 2100*2100 MM.
 NO OF C5F5 COLUMNS :5
• SIZE OF FOOTING 1800*1800 MM.
 NO OF C6F6 COLUMNS :6
• SIZE OF FOOTING 1800*1800 MM.
 NO OF C7F7 COLUMNS :3
• SIZE OF FOOTING 1700*1700 MM.
 NO OF C8F8 COLUMNS :4
• SIZE OF FOOTING 1200*1200 MM.
 SIZE OF F9 FOOTING 3600*2500 MM.
PLINTH BEAM DESIGN

 PLINTH BEAM 1
 NUMBER OF BEAMS 4
 SIZE OF BEAM 230*380MM
 PLINTH BEAM 2
 NUMBER OF BEAMS 27
 SIZE OF BEAM 230*300MM
SLAB BEAM REINFORCEMENT
LOCATION OF BEAM DESIGN
SLAB REINFORCEMENT

• SLAB HAS BEEN DESIGNED AS PER IS 456: 2000.


• SLAB : 120MM THICK RCC 8 MM BARS AT
150MM C/C IN BOTH WAYS.
• SLAB HEIGHT : 2700MM FROM TOP OF 2 LAYER
BRICKS TO SLAB BOTTOM LEVEL.
STAIRCASE DESIGN
[ STILT, FIRST, SECOND, THIRD & FOURTH FLOOR ]

• SLAB HAS BEEN DESIGNED AS PER IS 456:2000.


• OVERALL DEPTH OF SLAB IS 200MM,AND EFFECTIVE DEPTH
IS 150MM.
• WIDTH & LENGTH OF THE LANDING IS 1500MM, 3200MM.
• MAIN REINFORCEMENT IS 12MM DIA BARS @ 150MM C/C
(24 NO’S).
• DISTRIBUTOR REINFORCEMENT IS 6MM DIA BARS @
150MM C/C (62 NO’S).
• RISE & TREAD ARE 120MM & 250MM.
ARCHED STAIRCASE DESIGN
[ RIGHT & LEFT SIDE STILT FLOOR ]

• SLAB HAS BEEN DESIGNED AS PER


IS456:2000.
• OVERALL DEPTH OF SLAB IS 200MM,AND
EFFECTIVE DEPTH IS 150MM.
• TOTAL NUMBER OF STEPS IS 20 AT EACH
SIDE.
• RISE AND TRADE OF STAIRE CASE IS 150MM
AND 300 MM
• MAIN REINFORCEMENT IS 12MM DIA BARS
@ 150 C/C (12 NO’S) .
• DISTRIBUTOR REINFORCEMENT IS 6MM DIA
BARS @ 150 C/C (52 NO’S).
RAMP DESIGN
[ STILT, FIRST, SECOND & THIRD FLOOR ]

• SLAB HAS BEEN DESIGNED AS PER 456:2000.


• OVERALL DEPTH OF SLAB IS 200MM,AND EFFECTIVE
DEPTH IS 150MM.
• WIDTH & LENGTH OF THE LANDING IS 1700MM,
3000MM.
• MAIN REINFORCEMENT IS 12MM DIA BARS @ 150
C/C (24 NO’S).
• DISTRIBUTOR REINFORCEMENT IS 6MM DIA BARS @
150 C/C (106 NO’S).
CONCLUSION
THE PROJECT IS ABOUT DESIGN OF HOSPITAL BUILDING
 THE TOTAL PROJECT INCLUDES DESIGNING OF STRUCTURAL MEMBER LIKE
BEAM, SLAB, COLUMN, FOOTING.
 THE DESIGNING HAS BEEN DONE BASED ON REFERENCE OF IS CODE
456:2000.
 THE SOFTWARE AUTO CAD WAS USED FOR DRAWINGS (PLANS,SECTIONS)
AND FOR DRAWING REINFORCEMENT DETAILS OF SLABS, COLUMNS,
BEAMS AND FOOTING.
 THE VARIOUS LOAD COMBINATION AS PER IS CODE 456:2000.THE
STRUCTURE IS STABLE UNDER LOAD COMBINATIONS.