Professional Documents
Culture Documents
1
Kyocera Mita Corporation
Set up procedure
Photo1 Lock
2
Kyocera Mita Corporation
Set up procedure
6. Attach the seal to hide the screws (3 positions: Left side of the machine x 1,
right side of the machine x 2) (See the below photo 2 and 3)
7. Make a test copy and perform the image adjustment if it is necessary
Photo 2 Photo 3
3
Kyocera Mita Corporation
Set up procedure
1-2. [Connect the cassette heater]
8. Remove the screw and hook, and remove front right cover
(See the photo 4 and 5)
Photo 4 Photo 5
Remove
hook
4
Kyocera Mita Corporation
Set up procedure
1-2. [Connect the cassette heater]
9. Pull out the cassette
10. Insert the wire into the wire saddle and install the cassette heater on the
machine (See the drawing 1 and 2)
11. Connect the connector of the cassette heater (See the photo 6)
Drawing 2 Insert
Drawing 1
Screw
Connect the
cassette heater
Insert
Photo 6
5
Kyocera Mita Corporation
Set up procedure (Right angle adjustment (Fuser unit))
Specification
A B 6
Kyocera Mita Corporation
Set up procedure (Right angle adjustment (Fuser unit))
[Reference]
At the factory default, the marking is given on the position of the drawing 3 or drawing 4
Drawing 3 Drawing 4
At the factory default, black marking is In case if the ADJUSTOR FUSER is shifted to
given on the front side of the plate (side the right edge, marking is given on this
of the ADJUSTOR FUSER) position
7
Kyocera Mita Corporation
Set up procedure (Image adjustment)
Image adjustment
3. DP
1. Engine section (Center, Leading edge timing, Magnification): U034, U053, U402
2. Scanner section (Center, Leading edge timing, Magnification): U065, U066, U067, U403
8
Kyocera Mita Corporation
Set up procedure (Image adjustment)
1) U053: Set adjust data of the motor speed (Adjust the magnification)
Execute the Maintenance mode U053 and select the MOTOR to adjust
1. Press interrupt key to go into the test print screen
2. Select the specified cassette
3. Press Start Key to output the sample
4. Measure the length of the line for the Main scan direction and Sub scan direction
5. Change the value to make the setting within the above standard
9
Kyocera Mita Corporation
Set up procedure (Image adjustment)
2) U034: Set the paper timing data (Adjust Leading edge timing of the paper, center misalignment)
Execute the maintenance mode U034 and select the cassette to adjust
1. Press interrupt key and go into the test print screen
2. Select the specified cassette
3. Press Start Key to output the sample
4. Measure the center line and leading edge timing
5. Change the value to make the setting within the above standard
10
Kyocera Mita Corporation
Set up procedure (Image adjustment)
11
Kyocera Mita Corporation
Set up procedure (Image adjustment)
The difference of the margin on D 5. Adjust the Fuser Unit to make the setting
A-B ≤ 1mm within the above standard
12
Kyocera Mita Corporation