Set up procedure

(Machine main body)

1
Kyocera Mita Corporation
Set up procedure

1. [machine main body] Set up procedure

1. Remove fixing pin at the optical section * When transporting/moving the


machine, please make sure to set this fixing pin to hold (fix) the mirror
frame
2. Install the waste toner tank and insert the starter toner container which is
included in the machine (push the toner container to the end until it stops)
and lock (See the below photo 1)
3. Close the front cover
4. Plug in the power cord
5. Turn ON the main SW and toner install will start automatically (it takes
about 10 minutes)

Photo1 Lock

Insert the toner container

2
Kyocera Mita Corporation
Set up procedure

6. Attach the seal to hide the screws (3 positions: Left side of the machine x 1,
right side of the machine x 2) (See the below photo 2 and 3)
7. Make a test copy and perform the image adjustment if it is necessary

Photo 2 Photo 3

Left side of the machine Right side of the machine

Attach the seal x 3 positions to hide the screws

3
Kyocera Mita Corporation
Set up procedure
1-2. [Connect the cassette heater]
8. Remove the screw and hook, and remove front right cover
(See the photo 4 and 5)

Photo 4 Photo 5

Remove Slide the cover to the side


screw

Remove
hook

4
Kyocera Mita Corporation
Set up procedure
1-2. [Connect the cassette heater]
9. Pull out the cassette
10. Insert the wire into the wire saddle and install the cassette heater on the
machine (See the drawing 1 and 2)
11. Connect the connector of the cassette heater (See the photo 6)

Drawing 2 Insert
Drawing 1
Screw

Connect the
cassette heater

Insert
Photo 6
5
Kyocera Mita Corporation
Set up procedure (Right angle adjustment (Fuser unit))

Right angle adjustment is done by the following procedure


1. Execute U402 and make test print to check the right angle
2. In case of the image shown on the drawing 1, adjustment should be made based on the
drawing 2
* Specification: difference of the margin on D (|A-B| ≤ 1mm (See the below drawing)

Drawing 1 Drawing 2 ADJUSTOR FUSER

In case if the output image is Loosen the screw and


1 or 2, adjust the fuser unit shift the ADJUSTOR, and
as shown on the drawing 2 tighten the screw again

In case of the image 1,


shift to the left
Output Output
direction direction
In case of the image 2,
Image 1 Image 2 shift to the right

Specification

Difference of the margin on D


|A-B| ≤ 1mm

A B 6
Kyocera Mita Corporation
Set up procedure (Right angle adjustment (Fuser unit))

[Reference]
At the factory default, the marking is given on the position of the drawing 3 or drawing 4

Drawing 3 Drawing 4

At the factory default, black marking is In case if the ADJUSTOR FUSER is shifted to
given on the front side of the plate (side the right edge, marking is given on this
of the ADJUSTOR FUSER) position

7
Kyocera Mita Corporation
Set up procedure (Image adjustment)

Image adjustment

The procedure for the image adjustment

1. Writing the image (ENGINE section)

2. Scanning the original (SCANNER section)

3. DP

1. Engine section (Center, Leading edge timing, Magnification): U034, U053, U402

2. Scanner section (Center, Leading edge timing, Magnification): U065, U066, U067, U403

3. DP (Center, Leading edge timing, Magnification): U070, U071, U072, U404

8
Kyocera Mita Corporation
Set up procedure (Image adjustment)

1. Writing the image related (ENGINE section)

1) U053: Set adjust data of the motor speed (Adjust the magnification)

1. Change the value of the 2. Change the value of


POLYGON MOTOR (EXP2) the MAIN MOTOR (EXP1)
MAIN: Base cassette feeding
BYP: Bypass feeding
CAS: Optional cassette feeding
DUP: Duplex feeding

Adjust main scan direction


(270 +/- 1mm) Adjust sub scan direction
(300 +/- 1mm)

Execute the Maintenance mode U053 and select the MOTOR to adjust
1. Press interrupt key to go into the test print screen
2. Select the specified cassette
3. Press Start Key to output the sample
4. Measure the length of the line for the Main scan direction and Sub scan direction
5. Change the value to make the setting within the above standard
9
Kyocera Mita Corporation
Set up procedure (Image adjustment)

2) U034: Set the paper timing data (Adjust Leading edge timing of the paper, center misalignment)

1. Adjust the center misalignment 2. Adjust the leading edge timing


EXP1: Main body
EXP1: Main body
EXP2: Bypass
EXP2: Bypass
EXP3/4/5:
EXP3/4/5:
Option cassette 1/2/3
Option cassette 1/2/3
EXP1 Blinking: Duplex
EXP1 Blinking: Duplex

Center line Leading edge timing


(+/- 1mm) (20 +/- 1mm)

Execute the maintenance mode U034 and select the cassette to adjust
1. Press interrupt key and go into the test print screen
2. Select the specified cassette
3. Press Start Key to output the sample
4. Measure the center line and leading edge timing
5. Change the value to make the setting within the above standard

10
Kyocera Mita Corporation
Set up procedure (Image adjustment)

3) U402: Adjust the print margin

1. Adjust the print margin


LEAD : Leading edge
LEAD EDGE
(3 +/- 1mm) A : Front side of the image
C : Rear side of the image
C EDGE
(2.5 +/- 1mm) TRAIL : Trailing edge

Execute the maintenance mode U402 and select


the cassette to adjust
A EDGE
(2.5 +/- 1mm) 1. Press interrupt key and go into the test print
screen

TRAIL EDGE 2. Select the specified cassette


(3 +/- 1mm)
3. Press Start Key to output the sample
4. Measure each margin
5. Change the value to make the setting within
the above standard

11
Kyocera Mita Corporation
Set up procedure (Image adjustment)

3) U402: Adjust the print margin

2. Adjust the difference of the margin on D

Execute the maintenance mode U402 and select


the cassette to adjust

1. Press interrupt key and go into the test print


screen
2. Select the specified cassette
A B
3. Press Start Key to output the sample
4. Measure the margin of A and B

The difference of the margin on D 5. Adjust the Fuser Unit to make the setting
A-B ≤ 1mm within the above standard

(Please refer to the Page 6 on this presentation


for the details)

12