1. Fire Water Tank Location

Posisi Firewater Tank


2. Fire Water Tank Dimension
2.1 Mechanical data for Fire Water Tank

Equipment properties refer to equipment data for Fire Water Storage Tank (490-TK9002)
Equipment Inner diameter ID = 26120 mm
Bolt circle diameter BCD = 26410 mm
Equipment height H = 16610 mm
3. Foundation Design
3.1 Foundation Design
3. Foundation Design
3.1 Specification For Foundation Design & Equipment Properties
3. Foundation Design
3.2 Conseptual Design
3. Foundation Design
3.3 Loading Calculation
3. Foundation Design
3.4 Ringwall Sizing & Load Combination
3. Foundation Design
3.5 Sliding & Overturning Check
3. Foundation Design
3.6 Bearing Capacity Check
4. Settlement Analysis with PLAXIS
A. Soft Soil Model
• Calculation Stages:
A. Soft Soil Model
• The Soil parameter was used in this analysis was combined between CPTu-13 and GPF-BH-23 as follow:
Layer 1

Layer 2

Layer 3

Layer 4
Based on CPTu 13 and BH-23, Soil Properties for Soft Soil Model as Plaxis input as follow:
Elastic Settlement due
to Test Load = 20 cm

Settlement for 50 years


Period = 5,4 cm after
the hydrotest has been
done

Consolidation Settlement due to


Operation Load = 5,4 cm for 50
years Period
Differential Settlement =
3,0 cm < 0.55% *0.5D = 7.22cm
5. Specification
6. Conclusion
Base on the calculation, the result as follow:
• Sliding Check
Fos = 2.31 > 1.75 - OK
• Overturning Check
Fos = 2.17 > 2.00 - OK
• Soil Bearing Check
Qall = 307.48 kPa > Total Load = 270.30 ---- OK
• Differential Settlement
Differential Settlement = 3,0 cm < 0.55% *0.5D = 7.22cm ----- OK
• Settlement at Perimeter
Perimeter Settlement = 25,4 cm < 30 cm ----- OK