You are on page 1of 1

Engineering

High Injection Point


PROJECT:

REPORT OF PROBLEM ANALYSIS CONCLUSION

Quality control detects high injection point problem in part number: The height of the injection point is measured to determine if it is greater At the time of assembly with the PCB board, no
BN61-18883A, Problem is located in the assembly area of the PCB than the height of the Boss where the PCB board sits. The dimensional contact is generated between the injection point and
board. results show that the injection point has a maximum height of 2.18mm, the PCB. The injection point must not exceed
and the Boss 2.50mm, therefore which there is no possibility of it being 2.45mm.
related to any assembly problem.

OK NG
Condition Condition
Injection
Point

Assembly OK

Boss Support is required from the quality control and


production areas to notify personnel about this
NG defect, in order to not generate massive quantities in
Condition this condition in the future.

By Eng. Christian Coronel