You are on page 1of 1

AIR COOLER SERVICE: LIQUID COOLER: GAS OR VAPOR COOLER: NON-STM CONDENSER: STEAM CONDENSER: MIXED SERVICE

LIQUID COOLER
SELECT
A TYPE OF SERVICE

ITEM NO.:
FOR A COST ESTIMATE, ENTER THE REQUIRED INFORMATION BELOW:

E-2502

(OPTIONAL) CE INDEX FOR EQUIPMENT (1978's = 243) DESIGN PRESSURE, PSIG METALLURGY CODE

BARETUBE COEFFICIENT, 'U' HEAT DUTY, MMBTU/HR HOT FLUID INLET TEMP, F HOT FLUID OUT TEMP, F INLET AIR TEMPERATURE, F DO YOU WISH TO SPECIFY TUBE ROWS AND LENGTH? TUBE ROWS (3-10) = LENGTH (50' MAX) = ESTIMATED DIMENSIONS: WITH -

110.00 0.771 217.20 105.00 95.00 YES 3 16.0

427 1315 CS

'

ESTIMATED COST OF SPECIFIED UNIT WITH SPECIFIED METALLURGY: $36,660 TOTAL OPERATING FAN HP 5 CALCULATED TUBE ROWS 3 BARE TUBE AREA, FT 227 4'

16.0 ' TUBES (SPECIFIED), MINIMUM WIDTH IS:

Recommended air cooler specifications for preliminary estimate are: 16.0' Tube Length X 4' Total Width, 3 Tube Rows, 1 Bay With 2 - 20 HP Motor Fans

Source for ISO 9000 Considerations: YUBA Bulletin 21 - Air Cooled Exchangers, 1980

(YUBA no longer offers air cooled exchangers or this bulletin. Metallurgy cost factors are courtesy of Hudson Engineering, Inc., Houston, Texas.)
Z:\225_Process\Calculations\Equipment\Exchangers\Air Coolers\[E-2501air cooler.xls]Fast AC Method, Ver. 2.2

DATE:

04/12/06 CLIENT: Husky Oil (Madura) Ltd.

CONTRACT NO.:00A2MY000003 UNIT/AREA: 25

PROJECT NAME: HUSKY LOCATION: BY: ARB PURPOSE: G Kambing, Island, Indonsia CHK'D.: SHEET NO.: 1 OF 1