Professional Documents
Culture Documents
LIQUID COOLER
SELECT
A TYPE OF SERVICE
ITEM NO.:
FOR A COST ESTIMATE, ENTER THE REQUIRED INFORMATION BELOW:
E-2502
(OPTIONAL) CE INDEX FOR EQUIPMENT (1978's = 243) DESIGN PRESSURE, PSIG METALLURGY CODE
BARETUBE COEFFICIENT, 'U' HEAT DUTY, MMBTU/HR HOT FLUID INLET TEMP, F HOT FLUID OUT TEMP, F INLET AIR TEMPERATURE, F DO YOU WISH TO SPECIFY TUBE ROWS AND LENGTH? TUBE ROWS (3-10) = LENGTH (50' MAX) = ESTIMATED DIMENSIONS: WITH -
427 1315 CS
'
ESTIMATED COST OF SPECIFIED UNIT WITH SPECIFIED METALLURGY: $36,660 TOTAL OPERATING FAN HP 5 CALCULATED TUBE ROWS 3 BARE TUBE AREA, FT 227 4'
Recommended air cooler specifications for preliminary estimate are: 16.0' Tube Length X 4' Total Width, 3 Tube Rows, 1 Bay With 2 - 20 HP Motor Fans
Source for ISO 9000 Considerations: YUBA Bulletin 21 - Air Cooled Exchangers, 1980
(YUBA no longer offers air cooled exchangers or this bulletin. Metallurgy cost factors are courtesy of Hudson Engineering, Inc., Houston, Texas.)
Z:\225_Process\Calculations\Equipment\Exchangers\Air Coolers\[E-2501air cooler.xls]Fast AC Method, Ver. 2.2
DATE:
PROJECT NAME: HUSKY LOCATION: BY: ARB PURPOSE: G Kambing, Island, Indonsia CHK'D.: SHEET NO.: 1 OF 1