LIQUID COOLER
SELECT
A TYPE OF SERVICE
ITEM NO.:
FOR A COST ESTIMATE, ENTER THE REQUIRED INFORMATION BELOW:
E-2003
(OPTIONAL) CE INDEX FOR EQUIPMENT (1978's = 243) DESIGN PRESSURE, PSIG METALLURGY CODE
BARETUBE COEFFICIENT, 'U' HEAT DUTY, MMBTU/HR HOT FLUID INLET TEMP, F HOT FLUID OUT TEMP, F INLET AIR TEMPERATURE, F DO YOU WISH TO SPECIFY TUBE ROWS AND LENGTH? TUBE ROWS (3-10) = LENGTH (50' MAX) = ESTIMATED DIMENSIONS: WITH -
340 235 CS
'
ESTIMATED COST OF SPECIFIED UNIT WITH SPECIFIED METALLURGY: $85,126 TOTAL OPERATING FAN HP 36 CALCULATED TUBE ROWS 6 BARE TUBE AREA, FT 3,530 14'
Recommended air cooler specifications for preliminary estimate are: 36.0' Tube Length X 14' Total Width, 6 Tube Rows, 1 Bay With 2 - 25 HP Motor Fans
Source for ISO 9000 Considerations: YUBA Bulletin 21 - Air Cooled Exchangers, 1980
(YUBA no longer offers air cooled exchangers or this bulletin. Metallurgy cost factors are courtesy of Hudson Engineering, Inc., Houston, Texas.)
Z:\225_Process\Calculations\Equipment\Exchangers\Air Coolers\[E-2003 Lean Amine Cooler-GTU RevC.xls]Fast AC Method, Ver. 2.2
DATE:
Kambing Island, Indonesia CHK'D.: JCT ESTIMATE SIZE OF CONDENSATE COOLER SHEET NO.: 1 OF 1