State 1 (Superheated) State 2 (Superheated) State 3 (Mixture)
State 1 (Superheated) State 2 (Superheated) State 3 (Mixture)
State 1 (Superheated)
State 2 (Superheated)
State 3 (Mixture)
T1 = 520 C
P2 = 2 MPa
P3 = 0,5 MPa
P1 = 8 MPa
s1 = s2 = 6,7871 kJ/kg.K
s1 = s3 = 6,7871 kJ/kg.K
s1 = 6,7871 kJ/kg.K
h2 = 3036,1928 kJ/kg
h1 = 2734,2355 kJ/kg
h1 = 3447,7 kJ/kg
T2 = 308,91 C
T3 = 151,9 C
x3 = 0,9931
y = 0,2929
State 4 (Superheated)
State 5 (Superheated)
State 6 (Mixture)
T4 = 460 C
P5 = 15 MPa
P6 = 0,008 MPa
P4 = 0,5 MPa
s5 = s4 = 7,9726 kJ/kg.K
s6 = s5 = 7,9726 kJ/kg.K
s4 = 7,9726 kJ/kg.K
h5 = 3042,594 kJ/kg
h6 = 2496,3847 kJ/kg
h4 = 3398,6333 kJ/kg
T2 = 284,8545 C
T6 = 41,51 C
x6 = 0,9665
Jika y = 0,0071
(1 - y) h4 h5) + (1 - y - y) h5 h6)
(1 - 0,2929) (3398,6333 - 3042,594) + (1 - 0,2929 - 0,0071) (3042,594 - 2496,3847)
Wt2 = 50,728 MW
State 8
P7 = 0,008 MPa
P8 = 0,15 MPa
T7 = 41,51 C
h8 = 174,0232 kJ/kg
h7 = 173,88 kJ/kg
v7 = 1,0084
Wp1 = [(1 - y - y) h8 h7)]
= [(1 0,086 0,1927) (174,0232 - 173,88)] x 80
= 8,2632 KW
State 9 (Sat. Liq)
State 10
P9 = 0,5 MPa
P8 = 8 MPa
h9 = 640,23 kJ/kg
v = 1,0926
Wp = (hv hg) = 80 (648,4295 640,23) = 655,56 KW
0 = y h5 + (1 - y - y) h8 + y h15 - h9
h13 =
= 1695,3955 KJ/kg
h12 = h13 = 1695,3955 KJ/kg
State 12 (Mixture)
State 13 (Mixture)
P12 = 2 MPa
T12 = 212,4 C
T13 = 111,4 C
y =