400/220kV & 440/132kV GIS Substation for ERSS-VI

Contract No.:

Comment Sheet No.

COMMENT SHEET
Owner
Drawing Number

TBEAEI-EP19,20,21,22,23,26,27,
28,29 & 30

Contractor
Rev.

Status

Drawing Number

Rev.

Quality Assurance Plan


(10 documents)

Owners Comments

No.

The following QAP have been received and reviewed.

Type

Com.

Date of Comment
By Owner: 04/12/2014

Drawing Title

i)

Bus Post insulator

ii)

Capacitive Voltage transformer

iii)

Circuit Breaker

iv)

Current Transformer

v)

Isolator

vi)

Fasteners

vii)

Galvanized Lattice Structure

viii)

Surge Arrester/ Lightning Arrester

ix)

Galvanized Pipe Structure

x)
XLPE Cable
Specific comments are marked in the pdf files. The general comments
applicable to most submitted documents are given below.

Com.
No.

Date of Reply
By Contractor:

Contractors Reply

a)
b)
c)
d)
e)
f)
g)
h)

Mention the Project Title & Client name in header section.


Please mention Voltage Class of items where applicable.
Please indicate abbreviations as Note/Legend.
What is TBEA, M or S ? Please mention clearly in document.
Please identify brought out items & TBEA manufacturer items as we find
mention of Vendor drawing/Vendor Standard Procedure in lot of places.
The heading part which is in Page No. 1 should also come in all pages.
Essel to decide if any more witness points are required.
Please submit separate QAP for 220 kV and 132 kV XLPE Cable. If 33 kV
Cable is used then please submit separate QAP.