King Khalid International Airport

KKIA
Contract No.
DOC Submittals
4500001708
Project Name: Installation of new Fire and Domestic water piping networks.

Works Package
10
Name
Reference No.: FFC-4500001708-00000-Z3-DD-M-FF-M12-1-0001 Date: 02/08/2021
PMC/Contractor: First Fix Co Revision: 1
TO: Egis Co. FROM: First Fix Co.
Type:
Design Drawings Change Order Schedule Update Samples Reports

Shop Drawings As-Built Drawings Method Statement Others:

Discipline:
Architecture Civil/Structure Electrical/AGL Mechanical General

Projects Control Drainage/Water Topographical Others:

DESCRIPTION OF THE SUBMITTAL: DETAILED DESIGN DRAWINGS FOR FIRE FIGHTING


NETWORK ZONE - 3 Reply Required by: -

Subject: : DETAILED DESIGN DRAWINGS

Dear Engineer Ahmad EL- Ashry Kindly Find the Detailed design Drawings for firefighting network zone – 3 File for your review and approval.
Code-B
Mohamad Buraidi.
1. comments mentioned on drawings
ATTACHMENTS: 01.2.Sheet-8, Consider metro train crossing between the roads.
3.All fire hydrant needs isolation valve.
4.Any addition of fire hydrant in updated fire hydrant assessment should be
add in fire system drawing later.
5. Tie in is a important part of this project. prepare Tie-in schedule drawing
showing tie-in number, building no., location , zone, type of joint, size. (this
document will be used for taking permits and demonstration) (its important for
all zones).
6.contractor is responsible for any uncovered area.
7. Contractor need to add point in general note regarding existing services to
follow requirement. (as per MOM)
Requested By: Eng. Mohamad Buraidi Project Director
Name Designation Signature Stamp
Actions to be Taken (Riyadh Airports/PMC Decision) Comments By Decision Maker: Acknowledgment
Code A – Approved Work may proceed.
Code B – Approved with comments, resubmit, work
Code C - Revise and resubmit. Work may not
Decision Maker Stamp
Code D – Rejected, Not applicable

Name & Signature Date


King Khalid International Airport

COMMENT SUMMARY SHEET‐King Khalid International Airport‐ KKIAP‐

PMC comments FIRST FIX Response

1 Need stamp from NFPA CFPS. Drawings have been reviewed and stamped by NFPA CFPS.

2 Layout and profile should be as per increasing chainage. This has been revised accordingly.

Tie in number not seen


3 Indicate all tie‐in points and indicate tie –in number. All tie in points and tie in number is been shown accordingly

Verify operation & control of valves with SCADA/BMS network and provide separate
4 Noted
drawing for approval.

5 Verify pipe size again. Pipe size verified as per hydraulic model and depicted on layout and profiles

Air valves are located at high levels and wash outs at low level and shown in
6 Any low level needs washout chamber and high level needs air relief valve.
drawings

Thrust supports, concrete encasement, any concrete coverage details to be submit


7 Noted
separately.

Contractor is responsible for site co‐ordination with other services and maintain pipe
8 Noted
level and distance accordingly.

Contractor need to re‐verify and provide valves accordingly. Many valves are missing.
Provide valves as per distribution of network, operational & maintenance considerations
9 Valve placement has been reviewed and updated accordingly.
and isolation requirements. ( such as valves at Tee junction, intersection , mainline ,
branch line as per standard). ( technical attention required).

Provide clear indication of valves and type of valve with number. ( valve in valve box,
10 Clear indication of valves and type of valve with number has been provided
buried valve , type etc.).

11 Verify again for missing fire hydrant. Fire hydrant locations have been verified and updated accordingly.

Verify hydrant location again (physically on site). To maintain proper coverage as per
12 Fire hydrant locations have been verified and updated accordingly.
NFPA.
Regarding Air side ( AGL ,taxi way, apron and critical areas etc.) fire hydrant need to be
13 verify again. These are the critical areas. No elevated structure acceptable there. Provide Not Applicable for Zone 3 (air side included in zone 2)
fire hydrant type detail.

14 Maintain proper distance between valves in network as per standard. Noted

15 Sheet‐3 , valve missing at Tee junction and verify type of valves again. Valves at Tee junctions is been verified and updated accordingly

16 Provide isolation valve in pipe serving to the building UFA‐11.Sheet‐6. UFA‐11 BLV is provided and updated accordingly

17 Sheet‐11, provide valves in network. BLV is provided and updated accordingly

18 Sheet‐35, provide valves in network. BLV is provided and updated accordingly

19 Sheet‐38, provide valves in network. BLV is provided and updated accordingly

20
i. Comment number 1 to 14 : Noted
ii. Add the Note that “All HDPE pipes will protect with concrete encasement where
vertical clearance is less than 1.2m”
21
iii. Confirm that branch line and road-crossing profiles are not submitted due to
topographical survey permission issues; however, this all branch line profiles details will
be submitted as per topographical survey prior to start the construction for review and
22 approval.
iv. All Main line profile should be updated as per latest topographical and utility
survey and site condition prior to start the construction for review and approval.
23
v. Confirm the topo survey level at crossing metro line (from km 2+300 to 3+000)
vi. Show the metro line levels in the profile and confirm the pipeline should not
24
conflict with any metro structures.
vii. Check existing structures (hatching portion) at km 4+600
viii. Confirm that the routing should not conflict with public properties
25 Label the level of existing utility @2+560 (electrical) in profile

26

27

28
WETFIW
EUD

WETFIW
EUD
GENERAL NOTES

GATE 511
+617.35

Bollard
VDGS
BOX CARVERT

FRW
TRW
Road Trap

511.1
EUD

Bollard
VDGS
EUD

511.2
PB

FRW
FRW

FRW
A2

511.3

EUD
1. ALL DIMENSIONS ARE IN METRES UNLESS OTHERWISE

FRW

+611.89 fgl
Toll Gate

Toll Gate

Fire Hydrant
Floodlight
Bollard
EUD
STATED.

Fence Camera

EUD
Security Fence Lightings

TEW
150
A3

450
3300

GATE 510

EUD
450
(24'-9'')

(16'-7'')

150
(24'-9'')
R7550mm
R7550mm

R5060mm
(16'-7'') R5060mm

7425
40934
Ramp slope 6% Ramp slope 12% Ramp slope 6%

GATE 4000 32934 4000

R5

R8
450

VDGS
3300
450
450
3300 450 150
(24'-9'')

(16'-7'')
(24'-9'')

510.1
R7550mm
R7550mm

Bollard
VDGS
R5060mm

6800

MV
(16'-7'') R5060mm

TEW
5600 5600

B1
B2
L0

EXIT
L0
EXIT

510.2
B2
B1
B2

14
B1
L0
EXIT

PB

EUD
Fire Hydrant
Floodlight
64m

Bollard
TE W

65m

EUD
PB

Structure Below
PB

PB

GATE 509
55m

65m
64m

52m
B1
B2
EXIT

EXIT

EXIT
EXIT

63m

VDGS
Waste Storage Below

9
PB

FRW

EU
W ET

FUEL
Bollards

Concrete Parapet

509.1
Structure Below

Bollard
VDGS

EU
Discharge Pump Room Below

WETFIW
EXIT

10
EXISTING UTILITIES LEGEND

Brushed Reinforced Concrete

509.2
Honed/Flamed Natural Stone
N

65m

D
EUD

Balustrade

FRW
11

WETFIW
61m

TRW
13

Fire Hydrant
FIW

62m

Floodlight
Bollard
64m

EUD
(FOR LAYOUT)

62m

FRW
53m
65m
FRW

EUD
GATE 508
65m

FUEL
FRW
53m

VDGS
EUD

EUD
Trolleys

EUD
FUEL
65m

508.1
ARAMCO ARAMCO PIPE LINE

FRW TEW Bollard


VDGS

EUD
65m

508.2
55m
64m
EUD ELECTRICAL UTILITY DISTRIBUTION

Trolleys
PB

ffl +617.21 (-0.19)

ffl +617.45 (+0.05)

frl +617.35 (-0.05)

Fire Hydrant
Floodlight
Bollard
TEW
AREA
PARKING

DISABLED
VAN

EUD
FIRE WATER
Car Size Car Size

70
00x2 0)8 (1 7 0
00x2 0) 8
(1

FRW

GATE 507

EUD
VDGS
MEDIUM VOLTAGE
H

MEDVOL

EUD

H
H

EUD
DISABLED
VAN

507.1
Bollard
VDGS
PARKING
AREA

Trolleys

507.2
EU
EU TELCOM TELEPHONE LINE

THROUGH LANE

LANE FOR BUSES AND SHUTTLES


LOAD LANE FOR TAXIES &LOAD / UNLOAD

PAVEMENT

THROUGH TRAFFIC LANE

THROUGH TRAFFIC LANE

MANEUVERING LANE

CARS &UNLOAD LANE FOR TAXIES


LOAD / UNLOAD LANE FOR PRIVATE
D
D

Fire Hydrant
Floodlight
64m

Bollard
TEW TREATED EFFLUENT WATER

Trolleys

MVEUD
WETFIW

55m

GATE 506

FRW
TRW
WETFIW
FUEL AVIATION FUEL LINE

VDGS
N.IR

506.1
Male

Female

Bollard
VDGS
WC

Room
Family

Room
Jan.

WC
64m
PB

12
FRW

3
WETFIW FERTILIZED INJECTED WATER

506.2
Brushed Reinforced Concrete
62m

TEW

WETFIW
İPTAL

Concrete Parapet
ffl +617.40

ffl +612.75
EUD

Entrance for Ambulance


65m

Discharge Pump Room Below

Entrance for
Ambulance
65m
EUD

Fire Hydrant
WETPFW POTABLE FIRE WATER

FRW

Floodlight
TEW
Concrete Parapet

ffl +613.25
Structure Below

Escape Stairs

Bollard
Structure Below

Discharge Pump Room Below


WETPOW POTABLE WATER

GATE 505
PB

ffl +617.47
85m

VDGS
EXIT

EXIT

B1
B2
EUD

EUD

TEW
PB

505.1
EUD
B2
B1 EXIT B1
B2
GATE

Bollard
VDGS
EXIT
L0

EXIT
EXIT L0

WETSEW SEWAGE EFFLUENT

B2
B1

ffl +617.34
STOP

EUD
505.2
2
L0
B1 B1
B2

EUD EUD WETWLW WELL WATER

Toll Gate

Fire Hydrant
FRW

Floodlight
Bollard
5600 5600

(16'-7'') R5060mm

6800
(16'-7'')

VIP Canopy
(24'-9'') (24'-9'')

ffl +617.31
R5060mm

150 450
R7550mm
R7550mm

3300

R4

R1
450 450
3300
450
WETDEF DISCHARGE EFFLUENT FLOW

Toll Gate
4000 32934 4000

Bollards
Ramp slope 6% Ramp slope 12% Ramp slope 6%
40934

PB

7425
(16'-7'') R5060mm

(16'-7'')
(24'-9'') (24'-9'')

R5060mm
R7550mm
R7550mm

150
450

GATE 504
3300

FRW
ffl +617.47
450
150
D

TEW

EUD

VIP Canopy

VDGS
WETHPW HIGH PURITY WATER
EU

504.1

504.2
Bollard
VDGS

EUD
Service Road Below

Service Road Below


A1

FRW
TRW
WETINW INLET WATER

Security Fence

Fire Hydrant
WETFIW

Floodlight
Bollard
A4

Security Control
WETIRW IRRIGATION REGULATORY VALVE

FRW
EUD

frl +617.15
TRW UTW

EUD

EUD
Fence Camera
PB
EUD

TEW

FRW
TRW
WETFIW
Security Control
EUD EUD
EUD
FRW

WETFIW EUD

Crash Gate

EUD
Security Fence Lightings
Security Fence

TEW
EUD

FRW
TRW
EUD
EUD

WETFIW
FRW

WETFIW

D
EU
EU
D
TEW

FRW
TRW
D
EU
FRW
EUD

WETFIW
EUD

EUD
PB

TEW
TEW

FRW
TRW
FRW

EUD

WETFIW
PB
EUD
12A
PFT
UTW
TELCOM

PB
13A
PFT
TEW TEW TEW TEW TEW TEW TEW TEW TRWTEW
TEW TEW
TEW TEW
TEW TEW
TEW TEW
TEW TEW
TEW

GT18
TRW TRW TRW TRW TRW TRW TRW TRW TRW

VLV
UTW
END CAP - 250mm

GT25
TELCOM

TRW TRW TRW TRW TRW


TRW TRW
TRW TRW TRW

VLV

GT31
16B
PFT

18C
PFT

VLV
18A
PFT

19B
PFT
FOR CONTINUATION REFER
UTW DEAD LINE UTW DEAD LINE UTW
TO ZONE-2 PACKAGE

TEW
END CAP - 400mm

GT30
GT26

14B
PFT
GT27

GT29

VLV
VLV

GT28
10

VLV

VLV

VLV
E = 673984.1479

18F
PFT
TELCOM

FOR CONTINUATION REFER

GT46
VLV
TEW
WETIRW

TO ZONE-2 PACKAGE N = 2758818.4934

PB
E = 673105.0721

01

ESU
TEW
N = 2758290.4108
EUD
EUD

PB
PB
PB

PB
WETPOW

TEW
PB

PB

EUD
EUD
PB PBPB

PB
PB PB PB

PB
TELCOM

BOX CARVERT

FR
E = 673037.256 FH
E = 672991.096 N = 2758158.969
MEDVOL

END CAP - 400mm E = 674019.102

W
FOR CONTINUATION REFER N = 2758131.100
N = 2758759.155
WETSEW

TO ZONE-1 PACKAGE 160mmOD HDPE E = 673152.201


E = 671253.563

250mmOD HDPE
N = 2758210.946
N = 2757095.192 200x160 REDUCER

PB
TELCOM

E = 673044.195
PB

N = 2758147.313 BLV E = 673791.703


FH N = 2758578.658
AV

WETSAN

FH

PB
E = 673043.177
E = 673000.172 N = 2758141.398

200mmOD HDPE
EU
TR

N = 2758114.928

PB
E = 671262.277 E = 673046.495
400mmOD HDPE

160mmOD HDPE
N = 2757080.502 N = 2758143.450
E = 673048.075

WETSAN WETSAN WETSAN WETSAN WETSAN WETSAN WETSAN D

TRW

TEWWETIRW
E = 673142.224 E = 674064.097

PB
N = 2758141.035
TEW TEW TEW

PB
N = 2758126.215

WETFIW WETFIW
N = 2758674.194

07
W

FRW
PB

PB
E = 673123.925 E = 674067.847
N = 2758114.138 N = 2758676.403
EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD

PB
EUD EUD

PB
EUD EUD EUD

PB
N = 2757176.969

FH

PB
160mmOD HDPE BLV
E = 671623.052

PB

PB
PB

PB

PB

PB
PB

PB

PB

PB

PB

PB

PB

PB

PB
FH FH

EUD

EUD
160mmOD HDPE BLV BLV 160mmOD HDPE
E = 671310.786

PB
PB
FRW FRW FRW

PB

PB
N = 2756998.731 E = 671315.958 400x250 TEE E = 673095.842

PB
E = 673821.831

TRW
N = 2756996.738 E = 671522.803 N = 2758059.471 E = 673834.409
E = 671310.775 400x200 TEE E = 671627.397 EUD EUD
N = 2758522.162

EUD
N = 2757118.122

EUD EUD N
400x200 TEE N = 2757179.519 400x200 TEE N = 2758529.549
N = 2756993.795 E = 671514.379 E = 673141.029
FH FH
E = 671419.497 E = 672810.535 N = 2758085.457 EUD 400x160 TEE

N = 2758877.329
PB

PB
EUD
N = 2757113.177 E = 673096.670 E = 673165.827 250x160 REDUCER E = 675749.500
EUD EUD

E = 674526.605
E = 672303.085 E = 675253.017 EUD

PB
KEYPLAN
E = 672887.876 400x250 TEE

200mmOD HDPE
N = 2757057.481 N = 2757881.896 E = 673828.658

N = 2758623.867
E = 672715.992 E = 673016.789 N = 2758052.134 E = 673828.658

EUD EUD
E = 671633.071 E = 672587.079 N = 2758093.298 E = 674096.586 N = 2759626.147

E = 674105.138
BLV

BLV
N = 2757580.016 N = 2759331.072
PB

PB

PB

E = 671744.296 N = 2757927.921 E = 675212.616

BLV
N = 2757825.667 N = 2758004.612 N = 2758526.121

UTW
400mmOD HDPE N = 2757748.976 N = 2758526.121 N = 2758627.180
BLV BLV BLV BLV N = 2757182.849 N = 2757248.129 AV
BLVBLV FRW FRW FRW N = 2759285.657 FH FH FH FH EUD
FRW FRW FRW
BLV BLV 400mmOD HDPE 400mmOD HDPE BLV FH BLV

FRW
WO
UT

400mmOD HDPE
EUD
OM

400x250 TEE E = 673856.458 E = 675864.445


W

E = 671825.552 E = 672038.516 E = 675216.200


TELCOM WETPOW TELCOM E = 671952.436 E = 674268.814 E = 674698.465 END CAP - 400mm

11 12
200mmOD

BL

TELCOM TELCOM
E = 672120.089 N = 2758479.482

03 04 05 06 09 13
BLV

BLV

N = 2757276.218 E = 673789.209 E = 674483.640 E = 674569.570 E = 674827.360 E = 675171.079 E = 675207.820 N = 2759287.796 N = 2759674.993

PB
WETPOW WETPOW N = 2757351.237 N = 2757402.132
WETPOW WETPOW WETPOW WETPOW N = 2758723.889 N = 2758979.624 E = 674956.254
HDPE

N = 2757450.362 E = 672458.164 E = 674096.898 E = 674183.480 E = 675042.184 FOR CONTINUATION REFER

200mmOD HDPE BLV


E = 671514.366 N = 2758430.697 N = 2758851.755 N = 2758902.902 N = 2759056.345 N = 2759260.934 N = 2759282.803
N = 2758671.753 N = 2759133.066 N = 2759184.214 TO ZONE-5 PACKAGE

N = 2757851.236
AV N = 2757672.289 400x200 TEE E = 673863.237 N = 2758618.859 400mmOD HDPE

BLV
E = 673794.885 FH
AL TAYAREU

E = 671523.115 400mmOD HDPE AV

E = 672758.972
N = 2757113.147 400mmOD HDPE AV

N = 2758055.739
WO E = 673099.247 E = 673671.565 E = 673784.291 N = 2758475.956 400mmOD HDPE BLV BLV 400x160 TEE WO E = 675882.328

400x400 TEE
E = 673102.731

N = 2758080.360
400x160 TEE N = 2758434.167 400mmOD HDPE 400mmOD HDPE WO

N = 2758083.165
N = 2757110.007 WO

BLV
400x400 TEE

E = 673144.120
E = 671630.704 N = 2758053.666 N = 2758427.689 BLV BLV E = 675364.689 400x160 TEE

E = 673148.819
N = 2759686.122

BLV
N = 2758358.796

02
E = 671313.007 E = 671354.604 400x160 TEE N = 2757173.882 E = 672816.497 BLV 400mmOD HDPE N = 2759397.628 E = 675476.453 400x160 TEE
E = 671423.348 E = 673569.896 BLV BLV
LC

N = 2757019.388 E = 675712.589
WETIRW

N = 2756994.971 E = 671452.536 N = 2757871.843 400mmOD HDPE N = 2759464.027 400x160 TEE E = 675700.020

TELCOM
N = 2757050.988 E = 672222.078 N = 2758296.658

BLV
14 15 16
N = 2757076.875 E = 671643.700 E = 675588.233 N = 2759596.758 N = 2759604.224
N = 2757513.385 400x160 TEE
E = 671432.336 N = 2757151.727 N = 2759530.399
FH E = 675771.825 E = 675820.175

250mmOD HDPE
N = 2757035.833 E = 675214.582 N = 2759619.617 N = 2759648.525
N = 2759282.123

WETFIW
UTW

TEW
400x200 TEE
TE

E = 673791.689
WETPOW

400x160 TEE
400mmOD HDPE

E = 673859.825
N = 2758426.521 E = 674100.473
TE

L
N = 2758473.870

MEDVOL MEDVOL TELCOM MEDVOL TELCOM MEDVOL MEDVOL MEDVOL

FRWFRW
N = 2758621.015 E = 675226.787
TELCOM TELCOM TELCOM TELCOM TELCOM
AL TAYYAR

TELCOM TELCOM WETSEW TELCOM TELCOM TELCOM TELCOM TELCOM WETSEW TELCOM TELCOM TELCOM TELCOM
N = 2759260.311

VO
200

WETSEW WETSEW FRW WETSEW WETSEW WETSEW WETSEW WETSEW TEW WETSEW

250mmOD HDPE
FRW FRW FRW FRW FRW FRW TEW
AEREA

40
mm
MEDVOL

E = 672840.639
LC

0m
N = 2757831.141
OD

400x160 TEE

mO
ED
E = 671357.348 TIE-IN POINTS SHALL E = 673237.204
HD

D
GACA
N = 2758065.576
COVER THE NETWORK

HD
N = 2756906.186
PE

PE
FH
TIE-IN POINTS SHALL AND EXISTING HYDRANTS
W

Z4

TELCOM
OM

E = 671362.449
COVER THE NETWORK

TELCOM
N = 2756897.306
AND EXISTING HYDRANTS
WO

250
10007SQ.M.

PB
TE
mm

END CAP -400mm


OD

FOR FUTURE

D
WETSAN WETSAN WETSAN WETSAN WETSAN WETSAN
CONNECTION

EU
HDP

TIE-IN POINTS SHALL


WETPOW

E = 671366.129 TIE-IN POINTS SHALL

TEW
200
PB

TIE-IN POINTS SHALL COVER THE NETWORK


E

N = 2756890.899 COVER THE NETWORK

EU
mm

TRW
CARGO

AND EXISTING HYDRANTS COVER THE NETWORK AND EXISTING HYDRANTS


TELCOM

OD

TIE-IN POINTS SHALL AND EXISTING HYDRANTS

FRW
HD

COVER THE NETWORK

D
PE
D

AND EXISTING HYDRANTS

WO
E = 673344.196
N = 2758024.022 E = 673496.322
OM

N = 2758096.527

PB
08
TELCOM

200mmOD
FH HDPE
FRW Z1

AV
160mmOD HDPE

TEW
BLV FH
TIE-IN POINTS SHALL

OL
E = 673874.210
LC

COVER THE NETWORK FH


E = 673499.045 N = 2758300.602
AND EXISTING HYDRANTS 160mmOD HDPE FRW

WETIRW
E = 671684.708
N = 2757013.503 N = 2758079.133 250x200 TEE 200x160 REDUCER FRW

250mmOD HDPE
E = 673868.490 E = 673951.634
N = 2758346.592

V
N = 2758297.203
TE

AREA TO BE UPDATED
E = 673875.241

ED

TELCOM
18
N = 2758285.836
MED
TE

17 35
E = 673898.399

TELCOM
E = 671820.509 N = 2758259.668 200mmOD FH
N = 2757025.996 BLV HDPE 160mmOD HDPE

M Z5
250
LC

mm

43 44
250x200 TEE 200x160 REDUCER

42
OD

E = 673892.802 E = 673924.629
HD

N = 2758256.265 N = 2758275.214

400mmO

CAPPED
PE

VOL
WETIRW
PB

OM

E = 671856.496
TIE-IN POINTS SHALL

D HDPE
N = 2757003.967

D HDPE
FH
COVER THE NETWORK
AND EXISTING HYDRANTS

WETFIW
400mmO
WETPOW
MEDVOL

PB
EUD
W

FRW
FRW

FRW
NOT USED

TEW
TE

Z2
UTW
TIE-IN POINTS SHALL
WETSAN

Z5

1801B
200

PFT
COVER THE NETWORK
mm

AND EXISTING HYDRANTS


OD

E = 673540.526
OM

E = 673473.133

NOT USED NOT USED NOT USED


N = 2757952.813
HD

TEW
GOVERNMENT OFFICE
N = 2757912.605 FH
160mmOD HDPE
PE

FRW
BLV 200mmOD HDPE

IRW
985
FH E = 673952.327

.
E = 671854.920 N = 2758169.505

FRW
N = 2756911.844
LC

160mmOD HDPE
EUD

200x160 REDUCER
TELCOM

E = 674010.805
E = 673952.834
250x200 TEE N = 2758204.251
N = 2758155.233
E = 673946.434
EUD

FR

N = 2758166.003
TE

16
TE

44
250

15
mm

36
W
TELCOM

47
OD

43
LC

HD

14

PB
PE

42 46
13
MED

250x200

20
200

REDUCER
OM

19
45
FRW FRW

WETIRW
mm

E = 671997.670
N = 2756917.549

Z6 12
OD

10
HD

250mmOD HDPE
GACA
PE

11

45 46 47
FH PE
HD

09 35
VOL

OD
mm
200 E = 671956.805

WETIRW

07
N = 2756850.995

TEW
08 36
06
E = 671929.715

EUD
38

EUD
N = 2756805.638
E = 674030.616
EUD WETIRW

40
E = 671914.848 N = 2758024.215

05
FH
37
N = 2756780.749
160mmOD HDPE
200

41

NOT USED
FH
200

mm

04 Z3 39
mm

OD
WETPOW

OD
mm
OD

160 HDPE
HD

TIE-IN POINTS SHALL

03 18
PE
HD

COVER THE NETWORK

TELCOM
TIE-IN POINTS SHALL
PE

01
AND EXISTING HYDRANTS

TEW
COVER THE NETWORK
20

NOT USED NOT USED NOT USED


AND EXISTING HYDRANTS

WETFIW
02 17 26
WETSAN

FRW
E = 671972.934
N = 2756746.123 BLV

19 22
30
E = 671975.508

TEW
25
N = 2756750.442
FR

FRW
E = 672000.000 2
TIE-IN POINTS SHALL
29
W

N = 2756729.989
COVER THE NETWORK
24
33
AND EXISTING HYDRANTS
W

28
BLV
TE

OD E = 671997.522 23
TIE-IN POINTS SHALL
2

37
mm PE
N = 2756725.645

27 3
TE

160 HD
TE

COVER THE NETWORK

38
EUD

AND EXISTING HYDRANTS

31 34
LC
LC

250mmOD HDPE
21 22
E = 673928.480 E = 674108.554
OM

N = 2757893.158
OM

N = 2757761.106
FH
FR

E = 673933.269
FH
TELCOM

OD N = 2757753.021
mm E = 674012.267 160mmOD HDPE

160mmOD HDPE
160 PE E = 673926.761 N = 2757797.128

160mmOD HDPE

WETIRWTEW
HD
200

N = 2757749.086
TW

250x200 REDUCER
mm

E = 673865.193 E = 674096.918
E = 674011.001
OD

E = 673837.307 E = 673916.955 N = 2757850.215


N = 2757719.802
EW

N = 2757743.158 N = 2757799.277 E = 674124.274

BLV
FRW FRW FRW
HD

N = 2757695.994 TEW
WETFIW
N = 2757866.703

BLV
PE

BLV WO 160mmOD HDPE 200mmOD HDPE BLV 200mmOD HDPE BLV BLV

BLV

BLV
E = 672109.523 FH

BLV
N = 2756671.127 FH
E = 672106.964 E = 673918.264 E = 674096.918
200

N = 2756666.834 N = 2757741.025 N = 2757850.215 E = 674105.313


E = 673868.372
mm

160mmOD HDPE
N = 2757714.437 N = 2757855.235
OD

EUD

BLV
200x200 TEE E = 674104.176

EU
HD

E = 673937.203

NOT USED

200mmOD HDPE
N = 2757847.034 250x200 TEE
N = 2757755.274
PE

E = 674100.888
N = 2757852.563
WETIRW

E = 673948.395

WETIRW
N = 2757736.476
BLV

E = 672148.471

D
N = 2756642.328

EUD
FR
W

E = 672172.083
WETPOW

N = 2756628.387
E = 672169.580 BLV
TE

N = 2756624.059
W

OD

200mmOD HDPE
FH
mm 200x160 TEE
160 PE FH
HD E = 674176.111
WETSAN

N = 2757770.148

WETSAN
OD E = 674139.956

REVISIONS:
mm E = 674180.912
160HDPE N = 2757786.871

FRW
N = 2757773.001
FH
TEW
TE

BLV
160mmOD HDPE

40
E = 672229.878 V E = 674156.841

39
BL E = 672233.911 N = 2757758.480
N = 2756594.404
LC

N = 2756601.169
BLV

E = 674188.119
FR

TELCOM
23
N = 2757749.569
E = 672413.309

26
OM

EUD
E = 674190.896

EUD
TE

AV

N = 2756672.618

WETSAN
TE

N = 2757751.205

24 25
FH
WW

200mmOD HDPE
LC

160mmOD HDPE
200x160 REDUCER
E = 674019.293
E = 672422.151
N = 2757617.398
N = 2756667.421

EUD
200

EUD
OM

E = 674228.691
mm

N = 2757681.812
OD

E = 674230.527

TEW
N = 2757678.620
HD

986B
986A
PFT

PFT
IRW
TIE-IN POINTS SHALL 986

986C
PE

PFT
.
TELCOM

985B
PFT
COVER THE NETWORK FH BLV

BF964
BF963

VLV
VLV
AND EXISTING HYDRANTS E = 674233.321 BLV
FH TIE-IN POINTS SHALL N = 2757680.291
COVER THE NETWORK

BLV
OD E = 674233.461
W

AND EXISTING HYDRANTS

NOT USED
mm

NOT USED
FR

E = 672344.793 160 PE N = 2757673.774


200

N = 2756526.833 HD
E = 672342.242 E = 674236.230
mm

BLV N = 2756522.533 N = 2757675.430


TE
OD

E = 674237.559
AV

OD
HD

mm N = 2757666.839
PE
W

160 PE V
HD BL
E = 672354.221 E = 674065.428
E = 672368.919 N = 2757539.910
WETIRW

N = 2756521.278 N = 2756518.421

E = 674279.289
E = 672366.359 N = 2757635.899
N = 2756514.127 E = 674261.986
WETPOW

TE

N = 2757625.499

98602A
PFT
TEW

TEW
LC

WETSAN

V
TIE-IN POINTS SHALL

200mmOD HDPE
COVER THE NETWORK
FTRE

BL
E = 672579.126 AND EXISTING HYDRANTS

41
OD N = 2756574.898
mm
OM

160 PE
HD E = 672576.490
200

N = 2756570.427
W

FH
W mm

EUD E = 674322.079

P01 25/07/2021 COMMENTS INCORPORATED AJ


OD

N = 2757564.957
160mmOD HDPE

29
BLV

WETIRW
30

98601A
HD

28

PFT
27
PE

FH
EUD
TE

TEW

TEW
E = 674314.440
N = 2757560.455

WETSAN

98602
IRW
WETIRW

.
LC

200
mm

P00 30/06/2021 ISSUED FOR APPROVAL AJ


OD

OD E = 672517.179

98601
E = 674354.836

IRW
OM

HD

mm
FR

N = 2756425.262 E = 674341.818

98602B
160 PE BLV N = 2757510.649

PFT
PE

HD
TE

N = 2757502.757

E = 674351.759
E = 672514.551

TELCOM
NOT USED NOT USED
N = 2757486.023
W

N = 2756421.008
E = 674357.896
E = 672710.442
N = 2757467.509
N = 2756497.264 E = 674361.468
BLV
N = 2757469.682
EUD
NO. DATE DESCRIPTION APPROVED
E = 672707.920 BLV
TELCOM

N = 2756492.986 E = 674374.351 E = 674417.087


OD
mm E = 674369.140 N = 2757460.017 N = 2757485.722
160HDPE N = 2757456.882 WO 160mmOD HDPE

98601B
PFT
FH
TE
TFE

TEW

TEW
RW
WETPOW

PB
EUD

LC
W

EUD

98602C
PFT
WETSAN WETSAN WETSAN WETSAN WETSAN
O

200
M

MAIN CONSULTANT:
32
mm

31 33
OD

98602D
PFT
HD
PE

E = 672689.366
N = 2756323.494
OD
mm
160HDPE BLV E = 672686.836

98601C
N = 2756319.180

PFT
EUD

FH
E = 672865.018
200

OD
160 HDPE

E = 672821.745 N = 2756406.135
mm

mm

N = 2756333.081

98601D
OD

PFT
HD

E = 672819.053
PE

N = 2756328.535

NOT USED NOT USED


E = 672815.800
N = 2756323.045 E = 672832.745
BLV N = 2756351.652
BLV
BLV
WO

PE
HD E = 672824.363
OD E = 672834.118
mm N = 2756325.168
200 N = 2756318.984
TE

E = 672842.619

E = 672783.285
N = 2756268.152
N = 2756313.594
EUD
LC

PB
OM

TELCOM
EU
WETPOW

D
TELCOM

34
PB
EUD

EU
TE

NOT USED
D
LC

EU
OM

CLIENT:
PB

PB

D
EU
PB
PB

CONTRACTOR:

SUB-CONSULTANT:

Suite 1807, Damac Executive Heights


P.O.Box 80968
Barsha Heights, Dubai, UAE
Tel : +971 4 364 9235 Fax:+ 971 4 364 9225
Mail: dubai@jainconsultants.com

PROJECT NAME:

KING KHALID INTERNATIONAL AIRPORT


31.07.2021 KSA

DRAWING TITLE:

INFRA FIRE FIGHTING NETWORK


OVERALL LAYOUT ZONE-3

JOB NO. PAPER SIZE DRAWN CHECKED


A0 AS MM
SCALE DESIGNED APPROVED
DRAWING NO. NTS HK AJ
FFC-4500001708-00000-Z3-DD-M-FP-M10-1-001
STATUS DATE REVISION

DETAILED DESIGN 30/06/2021 P01


EUD
WET
TELCO

WETI
GENERAL NOTES

EUD
MEDVOL

EUD
TELCOM

EUD
1. ALL DIMENSIONS ARE IN METRES UNLESS OTHERWISE STATED.

EUD
2. DO NOT SCALE FROM THIS DRAWING. ONLY WRITTEN DIMENSIONS ARE

WETSAN
TO BE FOLLOWED.
.3 B
E
CO
T
U
C
V
N
H
T
E
L
R
P
W
O
T
R
S
GE
O
S
IP
O
IFR
S
E
K
D
P
RO
H
T
WE
C E
T
D
I STEEL SLEEVES.
4. PROPOSED FIRE NETWORK PIPE CROSSING THE EXISTING

TELCOM
N CARRIAGEWAY SHOULD BE LAID WITH THE ROAD CROSSING DUCT

TELCOM
(HORIZONTAL DRILLING METHOD).
5. FOR STANDARD DETAILS, REFER TO DRAWINGS
FFC-4500001708-00000-Z0-DD-M-FF-M10-0-001 TO

TELCOM
FFC-4500001708-00000-Z0-DD-M-FF-M10-0-013.

WETPOW
6. THE PROPOSED NETWORK SHALL BE LAID 500mm FOR HORIZONTAL

EUD
CLEARANCE AND 300mm FOR VERTICAL CLEARANCE WITH EXISTING

WETIRW
UTILITIES. IN ANY CASE WHERE THE MINIMUM VERTICAL CLEARANCE

TELCOM
CAN'T ABLE TO ACHIEVE PROPOSED PIPE SHALL BE PROTECTED WITH

EUD
MEDVOL
CONCRETE ENCASEMENT.

EUD
7. ALL EXISTING UTILITY LEVELS ARE INDICATED, HOWEVER THIS SHALL BE
VERIFIED AT SITE PRIOR TO THE CONSTRUCTION.
8. FOR EXISTING UTILITY LEGEND, REFER TO KEY PLAN DRAWING
FFC-4500001708-00000-Z3-DD-M-FF-M10-1-001.

WETSAN
TELCOM
9. FIRE HYDRANTS SHALL BE PROVIDED WITH FIRE HOSE HOUSES.

TELCOM
LEGEND (LAYOUT)
PROPOSED 160mmOD HDPE FIRE NETWORK

TELCOM
PROPOSED 200mmOD HDPE FIRE NETWORK
PROPOSED 250mmOD HDPE FIRE NETWORK

EUD
TELCOM

EUD
TELCOM TELCOM TELCOM PROPOSED 315mm OD HDPE FIRE NETWORK
TELCOMEUD

EUD
TELCOM
EUD PROPOSED 400mmOD HDPE FIRE NETWORK

WETPOW

EUD
PROPOSED PIPE REDUCER

WETIRW
MEDVOL
BLV
PROPOSED BUTTERFLY VALVE CHAMBER
WO

TELCOM
PROPOSED WASHOUT VALVE CHAMBER
AV
PROPOSED AIR RELEASE VALVE CHAMBER

WETSAN
TELCOM

FH EXISTING FIRE HYDRANT


FH PROPOSED FIRE HYDRANT WITH

EUD
ISOLATION VALVE

EUDEUD
EUD
TELCOM

PROPOSED ROAD CROSSING DUCT

EUD
(HORIZONTAL DRILLING METHOD)

PROPOSED END CAP


WETPOW

BOX CARVERT
MEDVOL
LEGEND (PROFILE)

WETIRW

TELCOM
FINISHED GROUND LEVEL
PROPOSED FIRE NETWORK LINE
PROPOSED BUTTERFLY VALVE CHAMBER
TELCOM

PROPOSED WASHOUT VALVE CHAMBER


END CAP - 400mm

WETSAN
EUD
TELCOM

FOR CONTINUATION REFER PROPOSED AIR RELEASE VALVE CHAMBER

EUD
EUD
PROPOSED ROAD CROSSING DUCT
TO ZONE-1 PACKAGE

EUD
(HORIZONTAL DRILLING METHOD)
ELECTRICAL CABLES
E = 671253.563 TELEPHONE CABLES
SEWER PIPELINE
ARAMCO PIPELINE

TELCOM
N = 2757095.192
MEDVOL

WATER PIPELINE OPTICAL FIBER CABLES


IRRIGATION PIPELINE
WETPOW

EUD
WETIRW

PB
TELCOM

N
KEYPLAN

AV
TELCOM

EUD

WETSAN
Z4

EU
Z1
E = 671262.277

TELCOM
D
400mmOD HDPE
Z5
N = 2757080.502
MEDVOL

EUD
TELCOM

Z5 Z2
WETPOW

EUD
EUD
WETIRW

16
15 44
43 47
14
46
TELCOM

13 42
45
Z6 10 12
11
09 35
PB

07
08 36
06 38
05 37 40
39 41
04 Z3
03 18
01 20
02 17 26
19 22
1 25 30

WETSAN
2
24 29
28 33
23
3 2
27
31 34

EU
D
LAYOUT PLAN
MEDVOL
TELCOM

EUD EUD
MATCH LINE EUD EUD EUD EUD EUD EUD
SCALE - 1:500
EUD
EUD

FOR CONTINUATION REVISIONS:


TELCOM

SEE DWG FFC-4500001708-00000-Z3-DD-M-FP-M10-1-003


WETPOW

TELCOM
EUD

E = 671310.786

P01 25/07/2021 COMMENTS INCORPORATED AJ


P00 30/06/2021 ISSUED FOR APPROVAL AJ
NO. DATE DESCRIPTION APPROVED

MAIN CONSULTANT:

31.07.2021

CLIENT:

CONTRACTOR:

SUB-CONSULTANT:

Suite 1807, Damac Executive Heights


P.O.Box 80968
Barsha Heights, Dubai, UAE
Tel : +971 4 364 9235 Fax:+ 971 4 364 9225
Mail: dubai@jainconsultants.com

PROJECT NAME:

KING KHALID INTERNATIONAL AIRPORT


KSA

DRAWING TITLE:

INFRA FIRE FIGHTING NETWORK ZONE 3


SHEET 01 OF 47

JOB NO. PAPER SIZE DRAWN CHECKED


A0 AS MM
SCALE DESIGNED APPROVED
DRAWING NO. AS SHOWN HK AJ
PROFILE VIEW FFC-4500001708-00000-Z3-DD-M-FP-M10-1-002
SCALE - H=1:500, V=1:50
ZONE-3 FF STA : 000.001 STA TO 075.000 STATUS DATE REVISION

DETAILED DESIGN 30/06/2021 P01


EUD
EUD
GENERAL NOTES

MEDVOL
EUD
EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD
MATCH LINE
EUD EUD EUD EUD EUD 1. ALL DIMENSIONS ARE IN METRES UNLESS OTHERWISE STATED.

TELCOM
WETPOW
TELCOM
2. DO NOT SCALE FROM THIS DRAWING. ONLY WRITTEN DIMENSIONS ARE
FOR CONTINUATION

WETIRW
TO BE FOLLOWED.
SEE DWG FFC-4500001708-00000-Z3-DD-M-FP-M10-1-002

TELCOM
.3 B
E
CO
T
U
C
V
N
H
T
E
L
R
P
W
O
T
R
S
GE
O
S
IP
O
IFR
S
E
K
D

WETSAN
P
RO
H
T
WE
C E
T
D
I STEEL SLEEVES.

EUD
E = 671310.786 4. PROPOSED FIRE NETWORK PIPE CROSSING THE EXISTING

EUD
EUD
CARRIAGEWAY SHOULD BE LAID WITH THE ROAD CROSSING DUCT
N = 2756998.731 N

MEDVOL
E = 671315.958

EUD
(HORIZONTAL DRILLING METHOD).

TELCOM
TELCOM
5. FOR STANDARD DETAILS, REFER TO DRAWINGS
N = 2756996.738 E = 671522.803 FFC-4500001708-00000-Z0-DD-M-FF-M10-0-001 TO

WETPOW
TELCOM
E = 671310.775 400x200 TEE FFC-4500001708-00000-Z0-DD-M-FF-M10-0-013.

WETIRW
400x200 TEE N = 2757118.122 6. THE PROPOSED NETWORK SHALL BE LAID 500mm FOR HORIZONTAL
N = 2756993.795 CLEARANCE AND 300mm FOR VERTICAL CLEARANCE WITH EXISTING

EUD
E = 671514.379

WETSAN
EUD
UTILITIES. IN ANY CASE WHERE THE MINIMUM VERTICAL CLEARANCE

EUD
EUD FH EUD EUD EUD E = 671419.497
EUD EUD EUD FH
EUD EUD EUD
EUD CAN'T ABLE TO ACHIEVE PROPOSED PIPE SHALL BE PROTECTED WITH
N =EUD2757113.177
EUD

EUD
MEDVOL

TELCOM
CONCRETE ENCASEMENT.

TELCOM
EUD
EU N = 2757057.481 EUD EUD
EUD
EUD EUD EUD EUD 7. ALL EXISTING UTILITY LEVELS ARE INDICATED, HOWEVER THIS SHALL BE

BLV
D EUD EUD EUD EUD EUD EUD EUD
VERIFIED AT SITE PRIOR TO THE CONSTRUCTION.

TELCOM
EUD
EUD EUD
8. FOR EXISTING UTILITY LEGEND, REFER TO KEY PLAN DRAWING
400mmOD HDPE

EUD
EU
BLV

WETPOW
BLV D
BLV BLV FFC-4500001708-00000-Z3-DD-M-FF-M10-1-001.

WETIRW

EUD
9. FIRE HYDRANTS SHALL BE PROVIDED WITH FIRE HOSE HOUSES.

EUD
EUD
EU

WETSAN
LEGEND (LAYOUT)
D

EUD
TELCOM
TELCOM

200mmOD
MEDVOL

BL
PROPOSED 160mmOD HDPE FIRE NETWORK

BLV
EUD
TELCOM
EU
PROPOSED 200mmOD HDPE FIRE NETWORK

HDPE
D

V
EUD
PROPOSED 250mmOD HDPE FIRE NETWORK
TELCOM
TELCOM TELCOM
TELCOM TELCOM
TELCOM TELCOM
TELCOM TELCOM TELCOM TELCOM
TELCOM TELCOM TELCOM TELCOM
TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM
TELCOM TELCOM
TELCOM TELCOM TELCOM TELCOM
TELCOM TELCOM
TELCOM TELCOM
TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOMTELCOM TELCOM TELCOM
E = 671514.366
TELCOM
TELCOM TELCOM TELCOM
PROPOSED 315mm OD HDPE FIRE NETWORK

WETPOW
EU

EUD
D
E = 671523.115

AL TAYAR CARGO
WETPOW WETPOW WETPOW WETPOW WETPOW WETPOW WETPOW WETPOW WETPOW WETPOW WETPOW WETPOW WETPOW WETPOW
N = 2757113.147

OM
EUD
WETIRW
PROPOSED 400mmOD HDPE FIRE NETWORK

EUD

TELCOM

LC

EU
400x400 TEE 400x160 TEE N = 2757110.007 PROPOSED PIPE REDUCER

TE
TE
EU

D
WETSAN
D

MEDVOL

L
BLV

CO
EUD
E = 671354.604

WETPOW
E = 671313.007 400x160 TEE PROPOSED BUTTERFLY VALVE CHAMBER

M
EUD EUD
E = 671423.348 WO
N = 2756994.971 N = 2757019.388 E = 671452.536 PROPOSED WASHOUT VALVE CHAMBER

OM
N = 2757050.988

EUD

LC
N = 2757076.875 AV

EUD

TELCOM
EUD
WETPOW

EU
TE TE
PROPOSED AIR RELEASE VALVE CHAMBER

WETIRW

LC

D
E = 671432.336

EUD

OM
FH
FH
EXISTING FIRE HYDRANT

MEDVOL

EUD

WETSAN
N = 2757035.833 FH PROPOSED FIRE HYDRANT WITH

WETPOW

OM
ISOLATION VALVE

LC
TETE
EUD
PROPOSED ROAD CROSSING DUCT

TELCOM

EU
LC
(HORIZONTAL DRILLING METHOD)

D
OM
400mmOD HDPE
EUD

EUD
WETPOW

EUD

SEE DWG FFC-4500001708-00000-Z3-DD-M-FP-M10-1-004


PROPOSED END CAP

WETIRW
MEDVOL

EUD

OM
LEGEND (PROFILE)

LC
WETSAN

TE
FINISHED GROUND LEVEL

TE
WETPOW

LC
AL TAYYAR

EU
TELCOM
L

EUD
MEDVOL PROPOSED FIRE NETWORK LINE

OM
VO

D
ED
M
PROPOSED BUTTERFLY VALVE CHAMBER

EUD

EUD

EUD

OM

20
WETPOW

LC
PROPOSED WASHOUT VALVE CHAMBER

EUD
MEDVOL

0m
WETIRW

AEREA

TE
TE
L
VO

LC
ED

EU
PROPOSED AIR RELEASE VALVE CHAMBER

OM

m
WETSAN
M

D
PROPOSED ROAD CROSSING DUCT

EUD

OD
WETPOW
400x160 TEE

TELCOM
(HORIZONTAL DRILLING METHOD)

OM
E = 671357.348

EUD

EUD

LC
L ELECTRICAL CABLES

EUD

HD
VO TELEPHONE CABLES

TE TE
ED ARAMCO PIPELINE SEWER PIPELINE
N = 2756906.186

LC
EUD
M
MEDVOL
WETPOW

PE
OM
WATER PIPELINE OPTICAL FIBER CABLES
WETIRW

IRRIGATION PIPELINE
FH
TIE-IN POINTS SHALL

FOR CONTINUATION
L

OM
TELCOM

WETSAN
VO
ED

LC

MATCH LINE
WETPOW
E = 671362.449 M

TE
COVER THE NETWORK

TE
EUD

EUD

EUD
N

EUD

LC
KEYPLAN
N = 2756897.306

OM
EUD
AND EXISTING HYDRANTS
MEDVOL

WO
VOL
WETPOW

ED

OM
10007SQ.
M
WETIRW

Z4

TELCOM

LC
TE
TE
LC
WETSAN
END CAP -400mm

OM
EUD

EUD

EUD
L

WETPOW
Z1

EUD
VO
FOR FUTURE ED
EUD

M Z5

OM
MEDVOL

CONNECTION

LC
TELCOM

TE
TE
WETPOW

E = 671366.129 Z2

20
LC
L Z5
VO
WETIRW

O
ED
PB

M
WETSAN WETSAN WETSAN WETSAN WETSAN WETSAN WETSAN WETSAN WETSAN WETSAN WETSAN WETSAN WETSAN WETSAN

0m
N = 2756890.899 M
EUD

EUD

16

EUD

EUD
15 44
43 47

OM
14

mO
46

WETPOW
13 42
45

LC
Z6 10 12
11
L

TE
TE
VO
09 35
MEDVOL

DH
TELCOM

07
36

LC
ED 06 08
38
M 40

OM
05 37
39 41
04 Z3
03 18
01
WETPOW

DP
17 20
EUD

02 22 26
19 30
25
WETIRW

2 1

OM
24 29
EUD

EUD

33
EUD

28
L

EUD
23

E
VO
2

LC
27 3
31 34
ED

TE TE
M

LC
LAYOUT PLAN

WETPOW
TELCOM

OM
MEDVOL

SCALE - 1:500 VO
L

OM
EUD

ED

LC
M
WETPOW

EUD

EUD

TE TE
REVISIONS:
EUD

EUD
WETIRW

LC
OM
P01 25/07/2021 COMMENTS INCORPORATED AJ
P00 30/06/2021 ISSUED FOR APPROVAL AJ
NO. DATE DESCRIPTION APPROVED

MAIN CONSULTANT:
31.07.2021

CLIENT:

CONTRACTOR:

SUB-CONSULTANT:

Suite 1807, Damac Executive Heights


P.O.Box 80968
Barsha Heights, Dubai, UAE
Tel : +971 4 364 9235 Fax:+ 971 4 364 9225
Mail: dubai@jainconsultants.com

PROJECT NAME:

KING KHALID INTERNATIONAL AIRPORT


KSA

DRAWING TITLE:

INFRA FIRE FIGHTING NETWORK ZONE 3


SHEET 02 OF 47

JOB NO. PAPER SIZE DRAWN CHECKED


A0 AS MM
SCALE DESIGNED APPROVED
DRAWING NO. AS SHOWN HK AJ
FFC-4500001708-00000-Z3-DD-M-FP-M10-1-003
ZONE-3 FF STA : 075.000 STA TO 427.000 PROFILE VIEW STATUS DATE REVISION
SCALE - H=1:500, V=1:50
DETAILED DESIGN 30/06/2021 P01
WETSEW

TELCOM
GENERAL NOTES

TR
W
N = 2757176.969
EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD
EUD EUD EUD EUD EUD
1. ALL DIMENSIONS ARE IN METRES UNLESS OTHERWISE STATED.

E = 671623.052
2. DO NOT SCALE FROM THIS DRAWING. ONLY WRITTEN DIMENSIONS ARE
TO BE FOLLOWED.
.3 B
E
CO
T
U
C
V
N
H
T
E
L
R
P
W
O
T
R
S
GE
O
S
IP
O
IFR
S
E
K
D

TELCOM
P
RO
H
T
WE
C E
T
D
I STEEL SLEEVES.

WETSEW

TR
4. PROPOSED FIRE NETWORK PIPE CROSSING THE EXISTING

W
CARRIAGEWAY SHOULD BE LAID WITH THE ROAD CROSSING DUCT

400x250 TEE N (HORIZONTAL DRILLING METHOD).


5. FOR STANDARD DETAILS, REFER TO DRAWINGS
FFC-4500001708-00000-Z0-DD-M-FF-M10-0-001 TO
E = 671627.397 FFC-4500001708-00000-Z0-DD-M-FF-M10-0-013.
6. THE PROPOSED NETWORK SHALL BE LAID 500mm FOR HORIZONTAL

TELCOM
N = 2757179.519

TR
CLEARANCE AND 300mm FOR VERTICAL CLEARANCE WITH EXISTING

W
UTILITIES. IN ANY CASE WHERE THE MINIMUM VERTICAL CLEARANCE

WETSEW
EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD
EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD CAN'T ABLE TO ACHIEVE PROPOSED PIPE SHALL BE PROTECTED WITH
EUD
CONCRETE ENCASEMENT.
EEUD= 671633.071 7. ALL EXISTING UTILITY LEVELS ARE INDICATED, HOWEVER THIS SHALL BE

PB
EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD
E EUD
= 671744.296
EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD VERIFIED AT SITE PRIOR TO THE CONSTRUCTION.
N = 2757182.849 8. FOR EXISTING UTILITY LEGEND, REFER TO KEY PLAN DRAWING

TELCOM

TR
N = 2757248.129

W
FFC-4500001708-00000-Z3-DD-M-FF-M10-1-001.
BLV BLV

UT
9. FIRE HYDRANTS SHALL BE PROVIDED WITH FIRE HOSE HOUSES.

W
E = 671825.552 LEGEND (LAYOUT)
E = 671952.436

WETSEW
BLV
PROPOSED 160mmOD HDPE FIRE NETWORK
N = 2757276.218 N = 2757351.237 PROPOSED 200mmOD HDPE FIRE NETWORK

TR
TELCOM

W
PROPOSED 250mmOD HDPE FIRE NETWORK
WETPOW WETPOW WETPOW WETPOW WETPOW WETPOW WETPOW WETPOW WETPOW WETPOW WETPOW WETPOW WETPOW WETPOW WETPOW WETPOW WETPOW WETPOW WETPOW WETPOW WETPOW WETPOW WETPOW WETPOW WETPOW WETPOW WETPOW PROPOSED 315mm OD HDPE FIRE NETWORK
400mmOD HDPE WO PROPOSED 400mmOD HDPE FIRE NETWORK
PROPOSED PIPE REDUCER
E = 671630.704 BLV

WETSEW

TR
N = 2757173.882 PROPOSED BUTTERFLY VALVE CHAMBER

W
TELCOM

W
TE
WO
PROPOSED WASHOUT VALVE CHAMBER
E = 671643.700 AV
PROPOSED AIR RELEASE VALVE CHAMBER
N = 2757151.727

TR
FH EXISTING FIRE HYDRANT

W
W
TELCOM

TE
WETSEW
FH PROPOSED FIRE HYDRANT WITH
ISOLATION VALVE
PROPOSED ROAD CROSSING DUCT
(HORIZONTAL DRILLING METHOD)

TR

SEE DWG FFC-4500001708-00000-Z3-DD-M-FP-M10-1-005


W
W
SEE DWG FFC-4500001708-00000-Z3-DD-M-FP-M10-1-003

PROPOSED END CAP

TE
TELCOM
LEGEND (PROFILE)
FINISHED GROUND LEVEL

WETSEW
EU

L MEDVOL MEDVOL MEDVOL MEDVOL MEDVOL MEDVOL MEDVOL MEDVOL MEDVOL MEDVOL MEDVOL MEDVOL MEDVOL MEDVOL MEDVOL MEDVOL MEDVOL MEDVOL MEDVOL MEDVOL MEDVOL MEDVOL MEDVOL MEDVOL MEDVOL MEDVOL MEDVOL MEDVOL MEDVOL
VO
D

ED
PROPOSED FIRE NETWORK LINE

TR
M

W
W
PROPOSED BUTTERFLY VALVE CHAMBER

TE
TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM
W
FR
L
PROPOSED WASHOUT VALVE CHAMBER
VO
ED
EU

M PROPOSED AIR RELEASE VALVE CHAMBER


D

TE
WETSEW WETSEW WETSEW WETSEW WETSEW WETSEW FRWWETSEW FRW WETSEW FRW WETSEW FRW WETSEW FRW WETSEW
FRW WETSEW
FRW WETSEW
FRW WETSEW
FRW WETSEW
FRW FRWWETSEW FRW WETSEW FRW WETSEW FRW WETSEW FRW
PROPOSED ROAD CROSSING DUCT

LC

FRW

W
TELCOM

TE
(HORIZONTAL DRILLING METHOD)

M
W
FR TELEPHONE CABLES ELECTRICAL CABLES
ARAMCO PIPELINE SEWER PIPELINE

TE

FR
LC
WATER PIPELINE OPTICAL FIBER CABLES

W
O
IRRIGATION PIPELINE

W
TE

FOR CONTINUATION
TELCOM
FOR CONTINUATION

MATCH LINE
TELCOM
MATCH LINE

N
KEYPLAN

FR
W
31.07.2021

W
250

TE
TELCOM
Z4
mm

TELCOM
FR
Z1
OD

W
W
Z5

TE
HD

TELCOM
20

Z5 Z2
PE

WETSAN WETSAN WETSAN WETSAN WETSAN WETSAN WETSAN WETSAN WETSAN WETSAN WETSAN WETSAN WETSAN WETSAN WETSAN WETSAN WETSAN WETSAN WETSAN WETSAN WETSAN WETSAN WETSAN WETSAN WETSAN WETSAN WETSAN WETSAN
0m

FR
W
16
44

W
15
OM

mO

43 47

TE
14
42 46
13
LC

45
Z6 10 12
TE TE

11
DH

09 35
LC

TELCOM

07
08 36
06 38
OM

05 37 40
39 41
04 Z3

FR
18
DP

03
01 20
02 17 26

W
19 22
25 30

W
OM

2 1
24 29

TE
E

28 33
LC

23
3 2
27
34
TE TE

31
LC

LAYOUT PLAN
OM

TELCOM
FR

SCALE - 1:500
W
OM

MATCH LINE
TE
LC
TE TE

FOR CONTINUATION REVISIONS:


LC

SEE DWG FFC-4500001708-00000-Z3-DD-M-FP-M10-1-018


OM

TELCOM

P01 25/07/2021 COMMENTS INCORPORATED AJ


P00 30/06/2021 ISSUED FOR APPROVAL AJ
NO. DATE DESCRIPTION APPROVED

MAIN CONSULTANT:

CLIENT:

CONTRACTOR:

SUB-CONSULTANT:

Suite 1807, Damac Executive Heights


P.O.Box 80968
Barsha Heights, Dubai, UAE
Tel : +971 4 364 9235 Fax:+ 971 4 364 9225
Mail: dubai@jainconsultants.com

PROJECT NAME:

KING KHALID INTERNATIONAL AIRPORT


KSA

DRAWING TITLE:

INFRA FIRE FIGHTING NETWORK ZONE 3


SHEET 03 OF 47

JOB NO. PAPER SIZE DRAWN CHECKED


A0 AS MM
SCALE DESIGNED APPROVED

ZONE-3 FF STA : 427.000 STA TO 885.000 DRAWING NO. AS SHOWN HK AJ


PROFILE VIEW FFC-4500001708-00000-Z3-DD-M-FP-M10-1-004
SCALE - H=1:500, V=1:50 STATUS DATE REVISION

DETAILED DESIGN 30/06/2021 P01


EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD
GENERAL NOTES
1. ALL DIMENSIONS ARE IN METRES UNLESS OTHERWISE STATED.
2. DO NOT SCALE FROM THIS DRAWING. ONLY WRITTEN DIMENSIONS ARE
TO BE FOLLOWED.
.3 B
E
CO
T
U
C
V
N
H
T
E
L
R
P
W
O
T
R
S
GE
O
S
IP
O
IFR
S
E
K
D
P
RO
H
T
WE
C E
T
D
I STEEL SLEEVES.
4. PROPOSED FIRE NETWORK PIPE CROSSING THE EXISTING
CARRIAGEWAY SHOULD BE LAID WITH THE ROAD CROSSING DUCT
N (HORIZONTAL DRILLING METHOD).
5. FOR STANDARD DETAILS, REFER TO DRAWINGS
FFC-4500001708-00000-Z0-DD-M-FF-M10-0-001 TO
FFC-4500001708-00000-Z0-DD-M-FF-M10-0-013.
6. THE PROPOSED NETWORK SHALL BE LAID 500mm FOR HORIZONTAL
CLEARANCE AND 300mm FOR VERTICAL CLEARANCE WITH EXISTING
EUD UTILITIES. IN ANY CASE WHERE THE MINIMUM VERTICAL CLEARANCE
EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD CAN'T ABLE TO ACHIEVE PROPOSED PIPE SHALL BE PROTECTED WITH
E = 672303.085 CONCRETE ENCASEMENT.
7. ALL EXISTING UTILITY LEVELS ARE INDICATED, HOWEVER THIS SHALL BE
N = 2757580.016

PB

PB
EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD VERIFIED AT SITE PRIOR TO THE CONSTRUCTION.
8. FOR EXISTING UTILITY LEGEND, REFER TO KEY PLAN DRAWING
FFC-4500001708-00000-Z3-DD-M-FF-M10-1-001.
9. FIRE HYDRANTS SHALL BE PROVIDED WITH FIRE HOSE HOUSES.

LEGEND (LAYOUT)
E = 672038.516
E = 672120.089 PROPOSED 160mmOD HDPE FIRE NETWORK
N = 2757402.132 PROPOSED 200mmOD HDPE FIRE NETWORK
N = 2757450.362 PROPOSED 250mmOD HDPE FIRE NETWORK
WETPOW WETPOW WETPOW WETPOW WETPOW WETPOW WETPOW WETPOW WETPOW WETPOW AV WETPOW WETPOW WETPOW WETPOW WETPOW WETPOW WETPOW WETPOW WETPOW WETPOW WETPOW WETPOW WETPOW WETPOW WETPOW WETPOW WETPOW WETPOW PROPOSED 315mm OD HDPE FIRE NETWORK
400mmOD HDPE PROPOSED 400mmOD HDPE FIRE NETWORK
PROPOSED PIPE REDUCER
BLV
PROPOSED BUTTERFLY VALVE CHAMBER
WO
E = 672222.078 PROPOSED WASHOUT VALVE CHAMBER
AV
N = 2757513.385 PROPOSED AIR RELEASE VALVE CHAMBER
FH EXISTING FIRE HYDRANT
FH PROPOSED FIRE HYDRANT WITH
ISOLATION VALVE
PROPOSED ROAD CROSSING DUCT
(HORIZONTAL DRILLING METHOD)
SEE DWG FFC-4500001708-00000-Z3-DD-M-FP-M10-1-004

SEE DWG FFC-4500001708-00000-Z3-DD-M-FP-M10-1-006


PROPOSED END CAP
LEGEND (PROFILE)
FINISHED GROUND LEVEL
MEDVOL MEDVOL MEDVOL MEDVOL MEDVOL MEDVOL MEDVOL MEDVOL MEDVOL MEDVOL MEDVOL MEDVOL MEDVOL MEDVOL MEDVOL MEDVOL MEDVOL MEDVOL MEDVOL MEDVOL MEDVOL MEDVOL MEDVOL MEDVOL MEDVOL MEDVOL MEDVOL MEDVOL MEDVOL MEDVOL MEDVOL
PROPOSED FIRE NETWORK LINE

TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM
PROPOSED BUTTERFLY VALVE CHAMBER
PROPOSED WASHOUT VALVE CHAMBER

PROPOSED AIR RELEASE VALVE CHAMBER


FRW WETSEW FRW WETSEW FRW WETSEW FRW WETSEW
FRW WETSEW
FRW WETSEW
FRW WETSEW
FRW WETSEW
FRW FRWWETSEW FRW WETSEW FRW WETSEW FRW WETSEW FRW WETSEW
FRW WETSEW
FRW WETSEW
FRW WETSEW
FRW WETSEW
FRW FRWWETSEW FRW WETSEW FRW WETSEW FRW WETSEW FRW WETSEW
FRW WETSEW
FRW WETSEW
FRW WETSEW
FRW WETSEW
FRW FRWWETSEW FRW WETSEW
PROPOSED ROAD CROSSING DUCT
(HORIZONTAL DRILLING METHOD)
TELEPHONE CABLES ELECTRICAL CABLES
ARAMCO PIPELINE SEWER PIPELINE
WATER PIPELINE OPTICAL FIBER CABLES
IRRIGATION PIPELINE
FOR CONTINUATION

FOR CONTINUATION
MATCH LINE

MATCH LINE
N
KEYPLAN

31.07.2021
Z4

Z1

Z5

Z5 Z2
WETSAN WETSAN WETSAN WETSAN WETSAN WETSAN WETSAN WETSAN WETSAN WETSAN WETSAN WETSAN WETSAN WETSAN WETSAN WETSAN WETSAN WETSAN WETSAN WETSAN WETSAN WETSAN WETSAN WETSAN WETSAN WETSAN WETSAN
16
15 44
43 47
14
42 46
13
45
Z6 10 12
11
09 35

07
08 36
06 38
05 37 40
39 41
04 Z3
03 18
01 20
02 17 26
19 22
1 25 30
2
24 29
28 33
23
3 2
27
31 34

LAYOUT PLAN
SCALE - 1:500 MATCH LINE
FOR CONTINUATION REVISIONS:
SEE DWG FFC-4500001708-00000-Z3-DD-M-FP-M10-1-019

P01 25/07/2021 COMMENTS INCORPORATED AJ


P00 30/06/2021 ISSUED FOR APPROVAL AJ
NO. DATE DESCRIPTION APPROVED

MAIN CONSULTANT:

CLIENT:

CONTRACTOR:

SUB-CONSULTANT:

Suite 1807, Damac Executive Heights


P.O.Box 80968
Barsha Heights, Dubai, UAE
Tel : +971 4 364 9235 Fax:+ 971 4 364 9225
Mail: dubai@jainconsultants.com

PROJECT NAME:

KING KHALID INTERNATIONAL AIRPORT


KSA

DRAWING TITLE:

INFRA FIRE FIGHTING NETWORK ZONE 3


SHEET 04 OF 47

JOB NO. PAPER SIZE DRAWN CHECKED


A0 AS MM
ZONE-3 FF STA : 885.000 STA TO 1350.000 DRAWING NO.
SCALE
AS SHOWN
DESIGNED APPROVED
HK AJ
PROFILE VIEW FFC-4500001708-00000-Z3-DD-M-FP-M10-1-005
SCALE - H=1:500, V=1:50 STATUS DATE REVISION

DETAILED DESIGN 30/06/2021 P01


EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD
GENERAL NOTES
EUD
EUD 1. ALL DIMENSIONS ARE IN METRES UNLESS OTHERWISE STATED.
2. DO NOT SCALE FROM THIS DRAWING. ONLY WRITTEN DIMENSIONS ARE
D EU TO BE FOLLOWED.
D
EU
EUD .3 B
E
CO
T
U
C
V
N
H
T
E
L
R
P
W
O
T
R
S
GE
O
S
IP
O
IFR
S
E
K
D
EUD
P
RO
H
T
WE
C E
T
D
I STEEL SLEEVES.
4. PROPOSED FIRE NETWORK PIPE CROSSING THE EXISTING
CARRIAGEWAY SHOULD BE LAID WITH THE ROAD CROSSING DUCT
N (HORIZONTAL DRILLING METHOD).
5. FOR STANDARD DETAILS, REFER TO DRAWINGS
FFC-4500001708-00000-Z0-DD-M-FF-M10-0-001 TO
FFC-4500001708-00000-Z0-DD-M-FF-M10-0-013.
6. THE PROPOSED NETWORK SHALL BE LAID 500mm FOR HORIZONTAL
CLEARANCE AND 300mm FOR VERTICAL CLEARANCE WITH EXISTING
UTILITIES. IN ANY CASE WHERE THE MINIMUM VERTICAL CLEARANCE
EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD CAN'T ABLE TO ACHIEVE PROPOSED PIPE SHALL BE PROTECTED WITH
CONCRETE ENCASEMENT.
E = 672587.079 E = 672715.992 7. ALL EXISTING UTILITY LEVELS ARE INDICATED, HOWEVER THIS SHALL BE
VERIFIED AT SITE PRIOR TO THE CONSTRUCTION.
N = 2757748.976 N = 2757825.667 AV 8. FOR EXISTING UTILITY LEGEND, REFER TO KEY PLAN DRAWING
FFC-4500001708-00000-Z3-DD-M-FF-M10-1-001.
WO 400mmOD HDPE 9. FIRE HYDRANTS SHALL BE PROVIDED WITH FIRE HOSE HOUSES.

LEGEND (LAYOUT)
PROPOSED 160mmOD HDPE FIRE NETWORK
PROPOSED 200mmOD HDPE FIRE NETWORK
E = 672458.164 PROPOSED 250mmOD HDPE FIRE NETWORK

N = 2757851.236
N = 2757672.289 PROPOSED 315mm OD HDPE FIRE NETWORK

E = 672758.972
WETPOW WETPOW WETPOW WETPOW WETPOW WETPOW WETPOW WETPOW WETPOW WETPOW WETPOW WETPOW WETPOW WETPOW WETPOW WETPOW WETPOW WETPOW WETPOW WETPOW WETPOW WETPOW WETPOW WETPOW WETPOW WETPOW WETPOW
PROPOSED 400mmOD HDPE FIRE NETWORK
PROPOSED PIPE REDUCER
BLV
PROPOSED BUTTERFLY VALVE CHAMBER
WO
PROPOSED WASHOUT VALVE CHAMBER
AV
PROPOSED AIR RELEASE VALVE CHAMBER
FH EXISTING FIRE HYDRANT
FH PROPOSED FIRE HYDRANT WITH
ISOLATION VALVE
PROPOSED ROAD CROSSING DUCT
(HORIZONTAL DRILLING METHOD)
SEE DWG FFC-4500001708-00000-Z3-DD-M-FP-M10-1-005

SEE DWG FFC-4500001708-00000-Z3-DD-M-FP-M10-1-007


PROPOSED END CAP
LEGEND (PROFILE)
FINISHED GROUND LEVEL
MEDVOL MEDVOL MEDVOL MEDVOL MEDVOL MEDVOL MEDVOL MEDVOL MEDVOL MEDVOL MEDVOL MEDVOL MEDVOL MEDVOL MEDVOL MEDVOL MEDVOL MEDVOL MEDVOL MEDVOL
PROPOSED FIRE NETWORK LINE

MED
PROPOSED BUTTERFLY VALVE CHAMBER

VOL
TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM

PROPOSED WASHOUT VALVE CHAMBER

PROPOSED AIR RELEASE VALVE CHAMBER


WETSEW
FRW WETSEW
FRW FRWWETSEW FRW WETSEW FRW WETSEW FRW WETSEW FRW WETSEW
FRW WETSEW
FRW WETSEW
FRW WETSEW
FRW WETSEW
FRW FRWWETSEW FRW WETSEW FRW WETSEW FRW WETSEW FRW WETSEW
FRW WETSEW
FRW WETSEW
FRW WETSEW
FRW WETSEW
FRW FRWWETSEW FRW WETSEW FRW WETSEW FRW WETSEW FRW WETSEW
FRW WETSEW
FRW WETSEW
FRW WETSEW
FRW
PROPOSED ROAD CROSSING DUCT
(HORIZONTAL DRILLING METHOD)

MED
VOL
TELEPHONE CABLES ELECTRICAL CABLES
ARAMCO PIPELINE SEWER PIPELINE
WATER PIPELINE OPTICAL FIBER CABLES
IRRIGATION PIPELINE
FOR CONTINUATION

FOR CONTINUATION
MED
MATCH LINE

MATCH LINE
VOL
N
KEYPLAN

31.07.2021 Z4

MED
VOL
Z1

Z5

Z5 Z2

MED
WETSAN WETSAN WETSAN WETSAN WETSAN WETSAN WETSAN WETSAN WETSAN WETSAN WETSAN WETSAN WETSAN WETSAN WETSAN WETSAN WETSAN WETSAN WETSAN

VOL
16
15 44
43 47
14
42 46
13
45
Z6 10 12

WETSAN
TIE-IN POINTS SHALL 09 35
11

07
08 36
06 38
05 37 40

COVER THE NETWORK 39 41


04 Z3
03 18
01 20

MED
02 17 26
19 22
1 25 30
2

AND EXISTING HYDRANTS 24 29

VOL
28 33
23
3 2
27
31 34

LAYOUT PLAN

WETSAN
SCALE - 1:500

MED
VOL
REVISIONS:

P01 25/07/2021 COMMENTS INCORPORATED AJ


P00 30/06/2021 ISSUED FOR APPROVAL AJ
NO. DATE DESCRIPTION APPROVED

MAIN CONSULTANT:

CLIENT:

CONTRACTOR:

SUB-CONSULTANT:

Suite 1807, Damac Executive Heights


P.O.Box 80968
Barsha Heights, Dubai, UAE
Tel : +971 4 364 9235 Fax:+ 971 4 364 9225
Mail: dubai@jainconsultants.com

PROJECT NAME:

KING KHALID INTERNATIONAL AIRPORT


KSA

DRAWING TITLE:

INFRA FIRE FIGHTING NETWORK ZONE 3


SHEET 05 OF 47

JOB NO. PAPER SIZE DRAWN CHECKED


A0 AS MM
SCALE DESIGNED APPROVED
DRAWING NO. AS SHOWN HK AJ

ZONE-3 FF STA : 1350.000 STA TO 1800.000 PROFILE VIEW FFC-4500001708-00000-Z3-DD-M-FP-M10-1-006


SCALE - H=1:500, V=1:50 STATUS DATE REVISION

DETAILED DESIGN 30/06/2021 P01


N = 2758131.100 GENERAL NOTES

WETFIW
FRW FRW FRW

EUD
160mmOD HDPE 1. ALL DIMENSIONS ARE IN METRES UNLESS OTHERWISE STATED.

EUD
2. DO NOT SCALE FROM THIS DRAWING. ONLY WRITTEN DIMENSIONS ARE

EUD
EUD
TO BE FOLLOWED.
.3 B
E
CO
T
U
C
V
N
H
T
E
L
R
P
W
O
T
R
S
GE
O
S
IP
O
IFR
S
E
K
D

FRW

FRW
200x160 REDUCER P
RO
H
T
WE
C E
T
D
I STEEL SLEEVES.
4. PROPOSED FIRE NETWORK PIPE CROSSING THE EXISTING

WW
TEW
E = 673044.195

EET
CARRIAGEWAY SHOULD BE LAID WITH THE ROAD CROSSING DUCT

W N
N

TSS

ET
(HORIZONTAL DRILLING METHOD).

AAN

W
EUD
WETFIW

FI
N = 2758147.313

TE
5. FOR STANDARD DETAILS, REFER TO DRAWINGS

WETFIW
EUD

W
BLV FFC-4500001708-00000-Z0-DD-M-FF-M10-0-001 TO

EUD
EUD
FFC-4500001708-00000-Z0-DD-M-FF-M10-0-013.
FH FH 6. THE PROPOSED NETWORK SHALL BE LAID 500mm FOR HORIZONTAL
CLEARANCE AND 300mm FOR VERTICAL CLEARANCE WITH EXISTING

WW
EET
UTILITIES. IN ANY CASE WHERE THE MINIMUM VERTICAL CLEARANCE

W
W N
TEW

TSS
E = 673043.177

TE
ET
AAN
CAN'T ABLE TO ACHIEVE PROPOSED PIPE SHALL BE PROTECTED WITH

FI
W
CONCRETE ENCASEMENT.

EUD
E = 673000.172 N = 2758141.398

EUD

200mmOD HDPE
7. ALL EXISTING UTILITY LEVELS ARE INDICATED, HOWEVER THIS SHALL BE
VERIFIED AT SITE PRIOR TO THE CONSTRUCTION.

EUD
EUD
N = 2758114.928 E = 673046.495
D 8. FOR EXISTING UTILITY LEGEND, REFER TO KEY PLAN DRAWING

WW
FFC-4500001708-00000-Z3-DD-M-FF-M10-1-001.

W
EU

EET
M

TE
31.07.2021 CO

W N
TEL 9. FIRE HYDRANTS SHALL BE PROVIDED WITH FIRE HOSE HOUSES.

TSS
N = 2758143.450

ET
AAN
TEWWETFIW

FI
W
M
CO
TEL LEGEND (LAYOUT)

EUD
E = 673048.075 PROPOSED 160mmOD HDPE FIRE NETWORK

EUD
D

M
EU

O
E = 673142.224 PROPOSED 200mmOD HDPE FIRE NETWORK

LC
EUD

W
N = 2758141.035

TE

TE
EU

WW
PROPOSED 250mmOD HDPE FIRE NETWORK

EET
N = 2758126.215

W N
TSS
PROPOSED 315mm OD HDPE FIRE NETWORK

ET
AAN

F IW
PROPOSED 400mmOD HDPE FIRE NETWORK

TEW
MEDVOL
MEDVOL

MEDVOL

MEDVOL
MEDVOL
MEDVOL
MEDVOL

MEDVOL

MEDVOL

MEDVOL
MEDVOL
MEDVOL

PROPOSED PIPE REDUCER

MEDVOL
MEDVOL

E = 673123.925
MEDVOL

TEW

D
WETFIW

EU
BLV

WETFIW
D

TELCOM
EU
PROPOSED BUTTERFLY VALVE CHAMBER
TELCOM TELCOM TELCOM TELCOM
N = 2758114.138
TELCOM TELCOM TELCOM TELCOM

W
EUD
TELCOM TELCOM TELCOM TELCOM TELCOM

ET
TELC
OM
WO

SA
TELCO

EUD
M

N
M
TELCO EUD PROPOSED WASHOUT VALVE CHAMBER
TE
LC
TELCO AV

PB
EUD
OM WETFIW
TEW
M
PROPOSED AIR RELEASE VALVE CHAMBER
TELCOM TELCOM TELCOM TELCOM TELCOM
EUD EUD TELCO
EUD
EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD M EUD
OM FH EXISTING FIRE HYDRANT

PB
LC

EUD
EU TE
D EU
D TE FH PROPOSED FIRE HYDRANT WITH

EU
LC
ISOLATION VALVE

EUD
OM

EUD
TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM

D
EUD
EUD EUD EUD
PROPOSED ROAD CROSSING DUCT
EUD EUD EUD EUD WETFIW EUD EUD (HORIZONTAL DRILLING METHOD)

E = 673095.842 PROPOSED END CAP

EUD
LEGEND (PROFILE)
N = 2758059.471 FINISHED GROUND LEVEL

EUD
400x200 TEE E = 673141.029 PROPOSED FIRE NETWORK LINE
EUD EUD EUD EUD EUD EUD E = 672810.535
EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD E = 673096.670 EUD EUD EUD N = 2758085.457 PROPOSED BUTTERFLY VALVE CHAMBER
N = 2757881.896 E = 672887.876 E = 673016.789 N = 2758052.134
EUD
EUD
EUD PROPOSED WASHOUT VALVE CHAMBER

BLV
N = 2757927.921

BLV
EUD
N = 2758004.612

EUD
EUD
EUD

EUD
EUD

EUD
PROPOSED AIR RELEASE VALVE CHAMBER

TELCOM
AV

TELCOM
TELCOM

TELCOM
TELCOM

EUD
400mmOD HDPE BLV BLV BLV PROPOSED ROAD CROSSING DUCT
(HORIZONTAL DRILLING METHOD)
TELEPHONE CABLES ELECTRICAL CABLES

TE
ARAMCO PIPELINE SEWER PIPELINE

W
WATER PIPELINE OPTICAL FIBER CABLES
200mmOD HDPE BLV

TELCOM
EUD
TELCOM
EUD
IRRIGATION PIPELINE
TELCOM

TELCOM
EUD
EUD

TELCOM
EUD

EUD
N = 2757851.236

400x200 TEE
E = 672758.972

WETPOW WETPOW WETPOW WETPOW WETPOW WETPOW WETPOW

N = 2758055.739
SEE DWG FFC-4500001708-00000-Z3-DD-M-FP-M10-1-006

E = 673099.247

SEE DWG FFC-4500001708-00000-Z3-DD-M-FP-M10-1-008


N = 2758080.360
400x400 TEE
E = 673102.731

TE
N = 2758083.165
N

E = 673144.120
KEYPLAN

W
N = 2758053.666

E = 673148.819
E = 672816.497

TELCOM
TELCOM
TELCOM

TELCOM
TELCOM
WETPOW

EUD
EUD

EUD
EUD

EUD

EUD
N = 2757871.843 Z4

Z1

Z5

EUD
WETPOW

Z5 Z2

16
15 44
43 47
14
42 46
13
45
Z6 10 12
11
09 35
FOR CONTINUATION

07
FOR CONTINUATION
08 36
06 38

EUD
05 37 40
41
MATCH LINE

04 Z3 39

MATCH LINE
03 18
WETPOW

01 20
02 17 26
19 22
1 25 30
2
24 29
28 33
23
TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM 27 3 2
34
31

E = 672840.639 LAYOUT PLAN

EUD
WETSEW WETSEW WETSEW WETSEW WETSEW FRWWETSEW WETSEW WETSEW WETSEW FRW WETSEW WETSEW WETSEW WETSEW WETSEW FRWWETSEW WETSEW WETSEW WETSEW FRW WETSEW WETSEW WETSEW WETSEW WETSEW FRWWETSEW WETSEW WETSEW WETSEW FRW WETSEW
FRW FRW FRW FRW FRW
N =FRW
2757831.141
FRW FRW FRW FRW FRW FRW FRW
SCALE - 1:500 FRW FRW FRW FRW FRW FRW FRW FRW FRW FRW FRW FRW
WETPOW

TIE-IN POINTS SHALL REVISIONS:

GACA
COVER THE NETWORK

P01 25/07/2021 COMMENTS INCORPORATED AJ


P00 30/06/2021 ISSUED FOR APPROVAL AJ
NO. DATE DESCRIPTION APPROVED

MAIN CONSULTANT:

CLIENT:

CONTRACTOR:

SUB-CONSULTANT:

Suite 1807, Damac Executive Heights


P.O.Box 80968
Barsha Heights, Dubai, UAE
Tel : +971 4 364 9235 Fax:+ 971 4 364 9225
Mail: dubai@jainconsultants.com

PROJECT NAME:

KING KHALID INTERNATIONAL AIRPORT


KSA

DRAWING TITLE:

INFRA FIRE FIGHTING NETWORK ZONE 3


SHEET 06 OF 47

JOB NO. PAPER SIZE DRAWN CHECKED


A0 AS MM
SCALE DESIGNED APPROVED
DRAWING NO. AS SHOWN HK AJ

ZONE-3 FF STA : 1800.000 STA TO 2250.000 PROFILE VIEW FFC-4500001708-00000-Z3-DD-M-FP-M10-1-007


SCALE - H=1:500, V=1:50 STATUS DATE REVISION

DETAILED DESIGN 30/06/2021 P01


WETSEW
EUD
TELCOM
EUD

EUD
GENERAL NOTES

EUD

D
EU
TEWTEW
1. ALL DIMENSIONS ARE IN METRES UNLESS OTHERWISE STATED.

WETSAN
WETFIW

TEW
2. DO NOT SCALE FROM THIS DRAWING. ONLY WRITTEN DIMENSIONS ARE
TELCOM TELCOM

EU
TO BE FOLLOWED.

TELCOM
EUD EUD EU
PB D

TRW
EUD .3 B
E
CO
T
U
C
V
N
H
T
E
L
R
P
W
O
T
R
S
GE
O
S
IP
O
IFR
S
E
K
D

TRW

N
TEW
EUD P
RO
H
T
WE
C E
T
D
I STEEL SLEEVES.

EUD

EUD
4. PROPOSED FIRE NETWORK PIPE CROSSING THE EXISTING

D
TEW WETSEW
TELCOM
EU

EU
D

EUD
CARRIAGEWAY SHOULD BE LAID WITH THE ROAD CROSSING DUCT
EU
D (HORIZONTAL DRILLING METHOD).

EUD

EUD
TEWTEW
EUD
5. FOR STANDARD DETAILS, REFER TO DRAWINGS
FFC-4500001708-00000-Z0-DD-M-FF-M10-0-001 TO

WETSAN

TELCOM
WETFIW
EU FFC-4500001708-00000-Z0-DD-M-FF-M10-0-013.
D

D
EU

TRW
6. THE PROPOSED NETWORK SHALL BE LAID 500mm FOR HORIZONTAL

EU
D

TRW

TEW
CLEARANCE AND 300mm FOR VERTICAL CLEARANCE WITH EXISTING

TELCOM
EUD
PB
UTILITIES. IN ANY CASE WHERE THE MINIMUM VERTICAL CLEARANCE

EUD
EU
CAN'T ABLE TO ACHIEVE PROPOSED PIPE SHALL BE PROTECTED WITH

WETSEW
D EU

EUD
CONCRETE ENCASEMENT.

EUD
D

TEWTEW

EUD
7. ALL EXISTING UTILITY LEVELS ARE INDICATED, HOWEVER THIS SHALL BE

TEW
TELCOM
EU
EU VERIFIED AT SITE PRIOR TO THE CONSTRUCTION.
D 8. FOR EXISTING UTILITY LEGEND, REFER TO KEY PLAN DRAWING

WETFIW
TRW
EU FFC-4500001708-00000-Z3-DD-M-FF-M10-1-001.

TEW
TRW

TELCOM
D
9. FIRE HYDRANTS SHALL BE PROVIDED WITH FIRE HOSE HOUSES.

EUD
EUD

WETSAN
LEGEND (LAYOUT)

D
EU
EUD
O

EUD

WETSEW
TEWTEW

EUD
EUD
EU
W PROPOSED 160mmOD HDPE FIRE NETWORK

TELCOM

TEW
D

EU
PROPOSED 200mmOD HDPE FIRE NETWORK

N = 2758210.946
D
FOR CONTINUATION REFER
PROPOSED 250mmOD HDPE FIRE NETWORK

E = 673152.201

TELCOM
TRW

TEW
PROPOSED 315mm OD HDPE FIRE NETWORK

TRW

D
WETFIW
PB

EU
EU
PB
PB
D
PROPOSED 400mmOD HDPE FIRE NETWORK
PROPOSED PIPE REDUCER

EUD
TO ZONE-2 PACKAGE

WETSAN

TELCOM
TEWTEW

EUD
BLV

TEW
WETSEW
EU PROPOSED BUTTERFLY VALVE CHAMBER

EUD
D

D
EU
WO

TELCOM
END CAP - 400mm

EUD
N = 2758290.4108
PB
PROPOSED WASHOUT VALVE CHAMBER

TEW
TRW

E = 673105.0721
TRW

AV

N = 2758024.022
EUD

WETFIW
PROPOSED AIR RELEASE VALVE CHAMBER

E = 673344.196
EU

SEE DWG FFC-4500001708-00000-Z3-DD-M-FP-M10-1-009


D

TELCOM
EUD

EUD
TEWTEW

EUD
FH

D
EXISTING FIRE HYDRANT

EU

TEW
WETSAN
EUD
EUD
FH PROPOSED FIRE HYDRANT WITH

TELCOM

WETSEW
EUD
EU
ISOLATION VALVE

EUD
D

TEW
TRW

PROPOSED ROAD CROSSING DUCT


TRW

PE
PB
(HORIZONTAL DRILLING METHOD)

D
EU

TELCOM
HD

WETFIW
EU
PROPOSED END CAP
TEWTEW

EUD
D

OD

TEW
LEGEND (PROFILE)

EUD

TELCTO
EUD

WETSAN
m

EUDEU M
FINISHED GROUND LEVEL
EUD
D
m

WETSEW
U

D
EM
0
DE

TEW
EU

EU
LCO
EU
40
D
PROPOSED FIRE NETWORK LINE
TRW

31.07.2021

D
TRW

TELCOM
PROPOSED BUTTERFLY VALVE CHAMBER
TEWTEW

EUD
D

WETFIW
U
DE EU
PROPOSED WASHOUT VALVE CHAMBER

TELCTO

TEW
W
EUD

EU D

D
TE

EU
EUD

EUDTEW
EUD

PROPOSED AIR RELEASE VALVE CHAMBER

EM

N = 2758093.298

FOR CONTINUATION
WETSAN
LCOM

E = 673165.827
PROPOSED ROAD CROSSING DUCT

WETSEW
D

E = 673237.204 W
TRW

MATCH LINE
(HORIZONTAL DRILLING METHOD)
U

TELCOM
EU

FR
TRW

DE
EU D
T EW

FR

N = 2758065.576
TELEPHONE CABLES ELECTRICAL CABLES

W
TEWTEW

FRW FRW
FRW FRW
FRW FRW
FRW FRW
FRW FRW
FRW FRW
FRW FRW
FRW FRW FRW FRW FRW FRW FRW FRW FRW FRW FRW FRW FRW

TELCO
FRW
FRW FRW
FRW FRW FRW FRW FRW FRW
SEWER PIPELINE
FRW
FRW FRW
FRW FRW
FRW
ARAMCO PIPELINE
EUD

WETFIW
OPTICAL FIBER CABLES
EUD

WATER PIPELINE
D
EU EU
W
EUD

EUD
TE IRRIGATION PIPELINE

M
D

EUD
TEW
FRW
FRW

WETSAN

TELCOM
TRW

FRW
TRW

WETSEW
D
EU
EU W N
TE KEYPLAN

TELCO
D
TEWTEW

EUD
EUD

M
EUD

EUD
WETFIW
EUD
EUD
W Z4
TE

TEW

TELCOM
FRW
TRW

FRW
TRW

TELCO
Z1

EUD

WETSEW

AND EXISTING HYDRANTS


TIE-IN POINTS SHALL
COVER THE NETWORK
N
TEWTEW

SA TE
W
EUD

ET Z5

EUD
EUD

W
EUD

EUD
W

TELCOM
FI
N = 2758083.165 Z5 Z2
ET
TE W N
FRW

W
AN E = 673148.819

TELCO
TRW

SA

WETSEW FRW
TS
TRW

EET 16

EUD
WW 15 44
43 47
14
TEWTEW

42 46

M
EUD

13
45
Z6 12
EUD

10

EUD
W 11
FI
EUD

EUD
09 35
ET
TE

07
08 36
06

TELCOM
W 38
W N

BLV
05 37 40

SSAAN 04 Z3 39 41
T 03 18
EET 01

N = 2758126.215
20

TELCO
17
WW
MATCH LINE 02 22 26
FRW

19 30
25

E = 673142.224
2 1
TRW

24 29

FRW
33
TRW

23 28
TE
IW FOR CONTINUATION 27 3 2

M
34
TEWTEW

31
F
SEE DWG FFC-4500001708-00000-Z3-DD-M-FP-M10-1-007
W
ET
BLV
EUD

W N
EUD

EUD

WETSEW
AAN
EUD

EUD
TSS

TELCOM
EET
400x400 TEE
W
LAYOUT PLAN

N = 2758085.457
W
N = 2758080.360

E = 673141.029
TELCO
N = 2758114.138
TE
W
W

E = 673123.925
I
SCALE - 1:500
FRW

TF E = 673144.120
TRW

FRW
REVISIONS:

M
PB
PB PB W N PB
AAN TELCOM
TSS
TE

EET MEDVOL MEDVOL


LC

EUD
WW
O
M

P01 25/07/2021 COMMENTS INCORPORATED AJ


P00 30/06/2021 ISSUED FOR APPROVAL AJ
NO. DATE DESCRIPTION APPROVED

MAIN CONSULTANT:

CLIENT:

CONTRACTOR:

SUB-CONSULTANT:

Suite 1807, Damac Executive Heights


P.O.Box 80968
Barsha Heights, Dubai, UAE
Tel : +971 4 364 9235 Fax:+ 971 4 364 9225
Mail: dubai@jainconsultants.com

PROJECT NAME:

KING KHALID INTERNATIONAL AIRPORT


KSA

DRAWING TITLE:

INFRA FIRE FIGHTING NETWORK ZONE 3


SHEET 07 OF 47

JOB NO. PAPER SIZE DRAWN CHECKED


A0 AS MM
ZONE-3 FF STA : 2250.000 STA TO 2500.000 ZONE-2 FF TIE IN STA : 000.000 STA TO 238.986 SCALE DESIGNED APPROVED
DRAWING NO. AS SHOWN HK AJ
PROFILE VIEW FFC-4500001708-00000-Z3-DD-M-FP-M10-1-008
SCALE - H=1:500, V=1:50 STATUS DATE REVISION

DETAILED DESIGN 30/06/2021 P01


W
ET
GENERAL NOTES

I
EU

RW
EU

D
1. ALL DIMENSIONS ARE IN METRES UNLESS OTHERWISE STATED.

TELCOM
2. DO NOT SCALE FROM THIS DRAWING. ONLY WRITTEN DIMENSIONS ARE

FRW

EU
TO BE FOLLOWED.

D
EUD
EUD
.3 B
E
CO
T
U
C
V
N
H
T
E
L
R
P
W
O
T
R
S
GE
O
S
IP
O
IFR
S
E
K
D
P
RO
H
T
WE
C E
T
D
I STEEL SLEEVES.

W
ET
D
4. PROPOSED FIRE NETWORK PIPE CROSSING THE EXISTING

EU
EU

IR
D
CARRIAGEWAY SHOULD BE LAID WITH THE ROAD CROSSING DUCT

W
N (HORIZONTAL DRILLING METHOD).

EU
MATCH LINE

TELCOM
5. FOR STANDARD DETAILS, REFER TO DRAWINGS

D
FFC-4500001708-00000-Z0-DD-M-FF-M10-0-001 TO
FRW
FOR CONTINUATION

EUD
FFC-4500001708-00000-Z0-DD-M-FF-M10-0-013.

EUD
SEE DWG FFC-4500001708-00000-Z3-DD-M-FP-M10-1-010

W
6. THE PROPOSED NETWORK SHALL BE LAID 500mm FOR HORIZONTAL

W
D

EU
O

ET
EU
CLEARANCE AND 300mm FOR VERTICAL CLEARANCE WITH EXISTING

RW I
E = 673344.196 UTILITIES. IN ANY CASE WHERE THE MINIMUM VERTICAL CLEARANCE

EU
CAN'T ABLE TO ACHIEVE PROPOSED PIPE SHALL BE PROTECTED WITH

D
N = 2758024.022 CONCRETE ENCASEMENT.

TELCOM
E = 673496.322 7. ALL EXISTING UTILITY LEVELS ARE INDICATED, HOWEVER THIS SHALL BE
VERIFIED AT SITE PRIOR TO THE CONSTRUCTION.
FRW

N = 2758096.527

EU
D

EUD
EUD
EU
8. FOR EXISTING UTILITY LEGEND, REFER TO KEY PLAN DRAWING

PB
FFC-4500001708-00000-Z3-DD-M-FF-M10-1-001.
9. FIRE HYDRANTS SHALL BE PROVIDED WITH FIRE HOSE HOUSES.

LEGEND (LAYOUT)

TELCOM
EUD

EU

WE
PROPOSED 160mmOD HDPE FIRE NETWORK

D
D
MATCH LINE

TIR
EU
PROPOSED 200mmOD HDPE FIRE NETWORK

AV

W
FRW

EUD
EUD
FOR CONTINUATION PROPOSED 250mmOD HDPE FIRE NETWORK
SEE DWG FFC-4500001708-00000-Z3-DD-M-FP-M10-1-008 PROPOSED 315mm OD HDPE FIRE NETWORK

EUD
PROPOSED 400mmOD HDPE FIRE NETWORK

TELCOM
PROPOSED PIPE REDUCER

EUD
D
E = 673499.045 BLV

EU
PROPOSED BUTTERFLY VALVE CHAMBER

EUD
EUD
FRW

N = 2758079.133 WO
PROPOSED WASHOUT VALVE CHAMBER

EUD
AV

WETIRW
PROPOSED AIR RELEASE VALVE CHAMBER

EUD
D
FH EXISTING FIRE HYDRANT

EU
FH PROPOSED FIRE HYDRANT WITH
FRW

ISOLATION VALVE

TELCOM
EUD
PROPOSED ROAD CROSSING DUCT
(HORIZONTAL DRILLING METHOD)

EUD
D

WETIRW
EU
PROPOSED END CAP
LEGEND (PROFILE)
FINISHED GROUND LEVEL

TELCOM
FRW

EUD
PROPOSED FIRE NETWORK LINE

EUD
PROPOSED BUTTERFLY VALVE CHAMBER

EUD

WETIRW
EUD
PROPOSED WASHOUT VALVE CHAMBER

TELCOM
PROPOSED AIR RELEASE VALVE CHAMBER
FRW

PROPOSED ROAD CROSSING DUCT


(HORIZONTAL DRILLING METHOD)

400mm

EUD
EUD
ELECTRICAL CABLES

EUD
TELEPHONE CABLES
ARAMCO PIPELINE SEWER PIPELINE
OPTICAL FIBER CABLES

TELCOM
WATER PIPELINE
IRRIGATION PIPELINE

OD HDP
FRW

ED HDP

EUD
EUD
N

EUD
KEYPLAN

WETIR
TELCOM
E

400mmO

W
31.07.2021 Z4
FRW

EUD

PB
EUD

Z1

TELCOM
Z5

EUD
EUD
Z5 Z2
FRW

EUD

16
15 44

WETIRW
43 47

TELCOM
14
42 46
13
45
Z6 10 12
11
09 35

07
36

EUD
06 08
38

EUD
05 37 40
39 41
04 Z3
FRW

03 18
01 20
02 17 26
19 22
1 25 30
2
24 29
28 33
23

TELCOM
3 2
27
31 34

E = 673540.526

WETIRW
EUD
E = 673473.133 EUD EUD EUD EUD

N = 2757952.813 LAYOUT PLAN

EUD
N = 2757912.605
SCALE - 1:500
FRW

TELCOM
REVISIONS:

P01 25/07/2021 COMMENTS INCORPORATED AJ


P00 30/06/2021 ISSUED FOR APPROVAL AJ
NO. DATE DESCRIPTION APPROVED

MAIN CONSULTANT:

CLIENT:

CONTRACTOR:

SUB-CONSULTANT:

Suite 1807, Damac Executive Heights


P.O.Box 80968
Barsha Heights, Dubai, UAE
Tel : +971 4 364 9235 Fax:+ 971 4 364 9225
Mail: dubai@jainconsultants.com

PROJECT NAME:

KING KHALID INTERNATIONAL AIRPORT


KSA

DRAWING TITLE:

INFRA FIRE FIGHTING NETWORK ZONE 3


SHEET 08 OF 47

JOB NO. PAPER SIZE DRAWN CHECKED


A0 AS MM
SCALE DESIGNED APPROVED
DRAWING NO. AS SHOWN HK AJ
FFC-4500001708-00000-Z3-DD-M-FP-M10-1-009
ZONE-3 FF STA : 2500.000 STA TO 2900.000 PROFILE VIEW
STATUS DATE REVISION
SCALE - H=1:500, V=1:50
DETAILED DESIGN 30/06/2021 P01
EUD

EU
WETSAN
M
TELCO EUD
GENERAL NOTES

TEW
WETSAN WETSAN WETSAN WETSAN WETSAN EUD
EUD

D
EUD

TELCOM
EUD EUD EUD EUD EUD EUD

WETFIW
TRW
EUD EUD
EUD TELCOM TELCOM TELCOM TELCOM
TELCOM TELCOM EUD EUD
COM
EUD EUD EUD EUD TELCOM

PB
EUD TELCOM TELCOM TELCOM EUD EUD 1. ALL DIMENSIONS ARE IN METRES UNLESS OTHERWISE STATED.
TEL
M EUD TELCOM

FRW
ELCO EUD EUD EUD EUD EUD EUD EUD EUD EUD
T EUD EUD EUD 2. DO NOT SCALE FROM THIS DRAWING. ONLY WRITTEN DIMENSIONS ARE
FH

TELCOM
TELCOM
EUD TELCOM TO BE FOLLOWED.
TELCOM TELCOM TELCOM
.3 B
E
CO
T
U
C
V
N
H
T
E
L
R
P
W
O
T
R
S
GE
O
S
IP
O
IFR
S
E
K
D
EUD EUD EUD EUD
160mmOD HDPE P
RO
H
T
WE
C E
T
D
I STEEL SLEEVES.
4. PROPOSED FIRE NETWORK PIPE CROSSING THE EXISTING
EUD EUD EUD

EUD
EUD

PB

UD
TELCOM

TEW WETFIW
CARRIAGEWAY SHOULD BE LAID WITH THE ROAD CROSSING DUCT
N (HORIZONTAL DRILLING METHOD).

TRW
E = 673821.831 5. FOR STANDARD DETAILS, REFER TO DRAWINGS

FRW
TELCOM
FFC-4500001708-00000-Z0-DD-M-FF-M10-0-001 TO

E UD
N = 2758522.162 FFC-4500001708-00000-Z0-DD-M-FF-M10-0-013.

EU
6. THE PROPOSED NETWORK SHALL BE LAID 500mm FOR HORIZONTAL

D
CLEARANCE AND 300mm FOR VERTICAL CLEARANCE WITH EXISTING
UTILITIES. IN ANY CASE WHERE THE MINIMUM VERTICAL CLEARANCE
TELCOM

EUD
PB

EUD

TEW
EUD
EUD EUD EUD EUD
EUD
CAN'T ABLE TO ACHIEVE PROPOSED PIPE SHALL BE PROTECTED WITH

PB
EUD EUD EUD EUD EUD EUD
E = 673828.658 CONCRETE ENCASEMENT.
EUD EUD

TRW
EUD

TELCOM
EUD EUD
EUD 7. ALL EXISTING UTILITY LEVELS ARE INDICATED, HOWEVER THIS SHALL BE

FRW
EUD EUD

WETFIW
N = 2758526.121 VERIFIED AT SITE PRIOR TO THE CONSTRUCTION.
EUD
EUD
EUD 8. FOR EXISTING UTILITY LEGEND, REFER TO KEY PLAN DRAWING
EU FFC-4500001708-00000-Z3-DD-M-FF-M10-1-001.

EUD
9. FIRE HYDRANTS SHALL BE PROVIDED WITH FIRE HOSE HOUSES.
TELCOM

EUD
WETIRW
400x250 TEE

TEW
WETIRW WETIRW WETIRW
WETIR
WETIRW WETIRW
LEGEND (LAYOUT)

TELCOM
W FRW FRW FRW FRW

EU

TRW
E = 673789.209 PROPOSED 160mmOD HDPE FIRE NETWORK

EU
D

PB
WETIR EUD

FRW
EU W
PROPOSED 200mmOD HDPE FIRE NETWORK
D
N = 2758430.697

WETFIW
PROPOSED 250mmOD HDPE FIRE NETWORK
WETIR
W
PROPOSED 315mm OD HDPE FIRE NETWORK

EUD
TELCOM

E = 673794.885

WETIRW
WETIR

EUD
W

FRW
31.07.2021 E = 673784.291 PROPOSED 400mmOD HDPE FIRE NETWORK

EUD
E = 673671.565

EU

TEW
EUD
N = 2758434.167

TELCOM
D
PROPOSED PIPE REDUCER
N = 2758427.689
EU

N = 2758358.796
D

TRW
BLV
PROPOSED BUTTERFLY VALVE CHAMBER

FRW
E = 673569.896 BLV BLV
400mmOD HDPE

W
WO

ET
TELCOM

N = 2758296.658 PROPOSED WASHOUT VALVE CHAMBER

WETFIW
IR

BLV
EU

W
EUD
EU
AV

FRW
EUD
D

WETIRW
PROPOSED AIR RELEASE VALVE CHAMBER

TELCOM
EUD

TEW
FH EXISTING FIRE HYDRANT

TRW
W
FH

FRW
PROPOSED FIRE HYDRANT WITH

ET
EU

EU
TELCOM

ISOLATION VALVE

IR
D

W
D

UTW
EU
PROPOSED ROAD CROSSING DUCT

WETFIW
E = 673791.689

TELCOM
EUD
(HORIZONTAL DRILLING METHOD)

FRW
EUD

TEW
WETIRW
D
EU N = 2758426.521 PROPOSED END CAP

TRW
W
LEGEND (PROFILE)

ET

SEE DWG FFC-4500001708-00000-Z3-DD-M-FP-M10-1-012


FRW
IR
TELCOM

EU

W
D FINISHED GROUND LEVEL
PROPOSED FIRE NETWORK LINE

TELCOM
EU

EUD
EU

FRW
EUD

TEW
PROPOSED BUTTERFLY VALVE CHAMBER
D

WETFIW
D

TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM W TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM

250mmOD
WETIRW
PROPOSED WASHOUT VALVE CHAMBER
ET
EU

TRW
IR

WETSAN
TELCOM

W
D

FRW
D
EU
PROPOSED AIR RELEASE VALVE CHAMBER
WETSEW TEW WETSEW TEW WETSEW TEW WETSEW
TEW WETSEW
TEW WETSEW
TEW WETSEW
TEW TEW WETSEW TEW WETSEW TEW WETSEW TEW WETSEW
TEW WETSEW
TEW WETSEW
TEW WETSEW
TEW TEW WETSEW TEW WETSEW TEW WETSEW
TEW WETSEW
TEW
PROPOSED ROAD CROSSING DUCT

TELCOM
TELCOM
EU

(HORIZONTAL DRILLING METHOD)


D

EUD
EUD

TEW
FRW
ELECTRICAL CABLES
W

TELEPHONE CABLES
EU D

WETFIW
ET
EU

SEWER PIPELINE

TEW
IR
D

EU
ARAMCO PIPELINE

HDPE
WETSEW
W

TRW

WETIRW
WATER PIPELINE OPTICAL FIBER CABLES
IRRIGATION PIPELINE

FRW

WETSAN
EU
D
TELCOM

EU D
EU

TEW
EUD
W

EU

FOR CONTINUATION
ET

FRW
D

D
N

TELCOM
KEYPLAN
IR
W

MATCH LINE
TEW WETSEW

WETFIW
EU

TRW

EUD
EUD
EUD
D
PB

WETIRW

FRW
Z4

WETSAN
TELCOM

TEW
EUD
EU

TELCOM
EU

Z1

FRW
D

TEW
Z5
W
ET

EUD

WETFIW
EUD
TRW

EUD
IR
EU

FRW
WETSEW
D

WETIRW
Z5 Z2
TELCOM

EU

WETSAN
TELCOM
D

TEW
16
15 44

FRW
43 47
14
46
W

42

TEW
13
45
ET

Z6 12
EU

10
11
IR
D

EUD
09 35

EUD
EUD
W

TRW

07
08 36
06 38

WETFIW
05 40
EU

37

FRW
MATCH LINE 39 41
TELCOM

04 Z3
MATCH LINE
D

18

WETSEW TEW
03
01 20

TELCOM
17

WETIRW
02 22 26
19
FOR CONTINUATION FOR CONTINUATION 2 1 25 30

TEW
24 29

WETSAN
SEE DWG FFC-4500001708-00000-Z3-DD-M-FP-M10-1-009 28 33
23
SEE DWG FFC-4500001708-00000-Z3-DD-M-FP-M10-1-036
W

3 2
27
EU

FRW
34
ET

31
D

IR
W

LAYOUT PLAN

EUD
EUD
EU

EUD
TRW
D
TELCOM

E = 673496.322

FRW
SCALE - 1:500

WETFIW
TELCOM
EUD EUD EUD

N = 2758096.527 EUD

WETSEW
EU

TEW
WETIRW
REVISIONS:
PB
D

EUD

WETSAN
FRW
EUD

TEW
P01 25/07/2021 COMMENTS INCORPORATED AJ
P00 30/06/2021 ISSUED FOR APPROVAL AJ
NO. DATE DESCRIPTION APPROVED

MAIN CONSULTANT:

CLIENT:

CONTRACTOR:

SUB-CONSULTANT:

Suite 1807, Damac Executive Heights


P.O.Box 80968
Barsha Heights, Dubai, UAE
Tel : +971 4 364 9235 Fax:+ 971 4 364 9225
Mail: dubai@jainconsultants.com

PROJECT NAME:

KING KHALID INTERNATIONAL AIRPORT


KSA

DRAWING TITLE:

INFRA FIRE FIGHTING NETWORK ZONE 3


SHEET 09 OF 47

JOB NO. PAPER SIZE DRAWN CHECKED


A0 AS MM
SCALE DESIGNED APPROVED
DRAWING NO. AS SHOWN HK AJ
ZONE-3 FF STA : 2900.000 STA TO 3350.000 PROFILE VIEW FFC-4500001708-00000-Z3-DD-M-FP-M10-1-010
SCALE - H=1:500, V=1:50 STATUS DATE REVISION

DETAILED DESIGN 30/06/2021 P01


GENERAL NOTES
N

TEW
1. ALL DIMENSIONS ARE IN METRES UNLESS OTHERWISE STATED.

WETSAN
2. DO NOT SCALE FROM THIS DRAWING. ONLY WRITTEN DIMENSIONS ARE

WETSAN
TO BE FOLLOWED.

WETFIW
WETFIW

FRW
.3 B
E
CO
T
U
C
V
N
H
T
E
L
R
P
W
O
T
R
S
GE
O
S
IP
O
IFR
S
E
K
D

TRW
FRW
P
RO
H
T
WE
C E
T
D
I STEEL SLEEVES.

TEW

TRW
4. PROPOSED FIRE NETWORK PIPE CROSSING THE EXISTING
CARRIAGEWAY SHOULD BE LAID WITH THE ROAD CROSSING DUCT
(HORIZONTAL DRILLING METHOD).

TEW
5. FOR STANDARD DETAILS, REFER TO DRAWINGS
FFC-4500001708-00000-Z0-DD-M-FF-M10-0-001 TO

WETSAN
FFC-4500001708-00000-Z0-DD-M-FF-M10-0-013.

FRW
WETSAN
WETFIW
6. THE PROPOSED NETWORK SHALL BE LAID 500mm FOR HORIZONTAL

WETFIW

TRW
FRW
TEW
CLEARANCE AND 300mm FOR VERTICAL CLEARANCE WITH EXISTING

TRW
UTILITIES. IN ANY CASE WHERE THE MINIMUM VERTICAL CLEARANCE
CAN'T ABLE TO ACHIEVE PROPOSED PIPE SHALL BE PROTECTED WITH
END CAP - 250mm

GT25
VLV
CONCRETE ENCASEMENT.

TEW

GT31
VLV
7. ALL EXISTING UTILITY LEVELS ARE INDICATED, HOWEVER THIS SHALL BE
TEWTEW
DEAD LINE TEWTEW TEWTEW TEWTEW TEWTEW TEWTEW TEWTEW TEWTEW TEWTEW TEWTEW TEWTEW TEWTEW TEWTEW TEWTEW TEWTEW TEWTEW TEWTEW TEWTEW TEWTEW TEWTEW TEWTEW TEWTEW TEWTEW TEWTEW TEWTEW TEWTEW TEWTEW TEWTEW FOR CONTINUATION
TEWTEW TEWTEW TEWTEW REFER
TEWTEW VERIFIED AT SITE PRIOR TO THE CONSTRUCTION.
8. FOR EXISTING UTILITY LEGEND, REFER TO KEY PLAN DRAWING
TO ZONE-2 PACKAGE
TRWTRW TRWTRW TRWTRW TRW
TRW TRW TRW TRW TRW TRW TRW TRW TRW TRW TRW TRW TRW TRW TRW TRW TRW TRW TRW TRW TRW TRW TRW TRW TRW TRW TRW

WETSAN
FFC-4500001708-00000-Z3-DD-M-FF-M10-1-001.

GT30
TEW

VLV
WETSAN
WETFIW
WETFIW
9. FIRE HYDRANTS SHALL BE PROVIDED WITH FIRE HOSE HOUSES.
E = 673984.1479

PFT
18F
LEGEND (LAYOUT)
N = 2758818.4934

TEW
PROPOSED 160mmOD HDPE FIRE NETWORK
PROPOSED 200mmOD HDPE FIRE NETWORK
PROPOSED 250mmOD HDPE FIRE NETWORK
PROPOSED 315mm OD HDPE FIRE NETWORK

TEW

WETSAN
PROPOSED 400mmOD HDPE FIRE NETWORK

WETSAN
WETFIW
WETFIW
PROPOSED PIPE REDUCER

TEW
BLV
PROPOSED BUTTERFLY VALVE CHAMBER
WO
PROPOSED WASHOUT VALVE CHAMBER

TEW
AV
PROPOSED AIR RELEASE VALVE CHAMBER
WETFIW
WETFIW
TEW

WETSAN
FH EXISTING FIRE HYDRANT
FH PROPOSED FIRE HYDRANT WITH
ISOLATION VALVE
TEW

PROPOSED ROAD CROSSING DUCT


(HORIZONTAL DRILLING METHOD)

PROPOSED END CAP


TEW
WETFIW
WETFIW

LEGEND (PROFILE)
WETSAN

FINISHED GROUND LEVEL


TEW

PROPOSED FIRE NETWORK LINE


FH PROPOSED BUTTERFLY VALVE CHAMBER
TEW

PROPOSED WASHOUT VALVE CHAMBER


WETFIW
WETFIW

E = 674019.102 PROPOSED AIR RELEASE VALVE CHAMBER


WETSAN

N = 2758759.155
TEW

PROPOSED ROAD CROSSING DUCT


(HORIZONTAL DRILLING METHOD)
TELEPHONE CABLES ELECTRICAL CABLES
TEW

250mmOD HDPE
ARAMCO PIPELINE SEWER PIPELINE
WATER PIPELINE OPTICAL FIBER CABLES
IRRIGATION PIPELINE
WETFIW
WETFIW
TEW

WETSAN

E = 673791.703 KEYPLAN
N
TEW

N = 2758578.658

FRW
Z4
WETFIW
WETFIW
TEW

WETSAN

Z1
TEW

TELCOM
EUD EUD Z5
160mmOD HDPE

FRW
Z2
TEW

Z5
WETFIW
WETFIW

16
FRW FRW FRW FRW FRW
E = 674064.097 44

PB
15
WETSAN

WETSAN WETSAN WETSAN WETSAN WETSAN WETSAN WETSAN WETSAN WETSAN WETSAN 43 47
14
TEW

WETSAN 42 46
13
45
Z6
N = 2758674.194 10 12

TELCOM
WETSAN 11
09 35

07
WETSAN 36
06 08
38
WETSAN 05 37 40
39 41
04 Z3
TEW
WETFIW
TEW
WETFIW
TEW
WETFIW
TEW
WETFIW
TEW WETSAN
E = 674067.847 01
03 18
20
EUD

02 17 26
19 22
FRW

WETSAN 1 25 30
2
29
WETSAN WETSAN WETSAN WETSAN WETSAN
LAYOUT PLAN N = 2758676.403 23
27
31
24
28
3 2
34
33
M
CO

SCALE - 1:500
TEL
TEW

EUD EUD EUD EUD EUD


WETFIW

TELCOM TELCOM TELCOM


TELCOM EUD EUD MATCH LINEEUD
EUD

TELCOM
FH
EUD TELCOM
160mmOD HDPEEUDBLV
PB

TELCOM TELCOM TELCOM EUD TELCOM EUD TELCOM EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD
FRW

TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM
EUD EUD EUD EUD EUD EUD EUD EUD
MEDVOL

EUD EUD EUD

PB

PB
EUD
MEDVOL

EUD EUD EUD EUD EUD EUD EUD


FOR CONTINUATION EUD EUD EUD EUD EUD EUD EUD EUD
PB

EUD EUD EUD


MEDVOL

MEDVOL

REVISIONS:
FH
MEDVOL
MEDVOL
TELCOM

MEDVOL
MEDVOL

MEDVOL

FH
MEDVOL
MEDVOL
MEDVOL
MEDVOL

MEDVOL

MEDVOL

SEE DWG FFC-4500001708-00000-Z3-DD-M-FP-M10-1-012


160mmOD HDPE BLV BLV 160mmOD HDPE

P01 25/07/2021 COMMENTS INCORPORATED AJ


P00 30/06/2021 ISSUED FOR APPROVAL AJ
NO. DATE DESCRIPTION APPROVED

MAIN CONSULTANT:

CLIENT:

CONTRACTOR:

SUB-CONSULTANT:

Suite 1807, Damac Executive Heights


P.O.Box 80968
Barsha Heights, Dubai, UAE
Tel : +971 4 364 9235 Fax:+ 971 4 364 9225
Mail: dubai@jainconsultants.com

PROJECT NAME:

KING KHALID INTERNATIONAL AIRPORT


KSA

DRAWING TITLE:

INFRA FIRE FIGHTING NETWORK ZONE 3


SHEET 10 OF 47
31.07.2021
JOB NO. PAPER SIZE DRAWN CHECKED
A0 AS MM
SCALE DESIGNED APPROVED
DRAWING NO. AS SHOWN HK AJ
FFC-4500001708-00000-Z3-DD-M-FP-M10-1-011
STATUS DATE REVISION

DETAILED DESIGN 30/06/2021 P01


GENERAL NOTES

TEW
EUD EUD EUD EUD EUD

WETFIW
TELCOM TELCOM TELCOM
TELCOM EUD EUD
MATCHEUD
LINE

EUD
TELCOM
FH
EUD TELCOM
160mmOD HDPEEUDBLV

PB
TELCOM TELCOM TELCOM EUD TELCOM EUD TELCOM EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD 1. ALL DIMENSIONS ARE IN METRES UNLESS OTHERWISE STATED.

FRW
TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM
EUD EUD EUD EUD EUD EUD EUD EUD
MEDVOL
MEDVOL

EUD EUD EUD

PB

PB
EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD

PB
EUD EUD 2. DO NOT SCALE FROM THIS DRAWING. ONLY WRITTEN DIMENSIONS ARE

MEDVOL

MEDVOL
FH
MEDVOL

TELCOM
MEDVOL
MEDVOL

FOR CONTINUATION

MEDVOL
MEDVOL

FH
MEDVOL

MEDVOL
MEDVOL
MEDVOL
MEDVOL

MEDVOL

TO BE FOLLOWED.
SEE DWG FFC-4500001708-00000-Z3-DD-M-FP-M10-1-011 .3 B
E
CO
T
U
C
V
N
H
T
E
L
R
P
W
O
T
R
S
GE
O
S
IP
O
IFR
S
E
K
D
160mmOD HDPE BLV BLV 160mmOD HDPE P
RO
H
T
WE
C E
T
D
I STEEL SLEEVES.
4. PROPOSED FIRE NETWORK PIPE CROSSING THE EXISTING

EUD
N

TEW WETFIW
CARRIAGEWAY SHOULD BE LAID WITH THE ROAD CROSSING DUCT
(HORIZONTAL DRILLING METHOD).
E = 673821.831 5. FOR STANDARD DETAILS, REFER TO DRAWINGS

FRW
TELCOM
E = 673834.409 FFC-4500001708-00000-Z0-DD-M-FF-M10-0-001 TO
N = 2758522.162 N = 2758529.549
FFC-4500001708-00000-Z0-DD-M-FF-M10-0-013.
6. THE PROPOSED NETWORK SHALL BE LAID 500mm FOR HORIZONTAL
CLEARANCE AND 300mm FOR VERTICAL CLEARANCE WITH EXISTING
UTILITIES. IN ANY CASE WHERE THE MINIMUM VERTICAL CLEARANCE

EUD
250x160 REDUCER

TEW
EUD EUD EUD EUD EUD EUD
EUD
EUD
EUD CAN'T ABLE TO ACHIEVE PROPOSED PIPE SHALL BE PROTECTED WITH
E = 673828.658 CONCRETE ENCASEMENT.

200mmOD HDPE
EUD EUD

N = 2758623.867
EUD EUD

TELCOM
E = 673828.658
EUD
E = 674096.586
EUD EUD
7. ALL EXISTING UTILITY LEVELS ARE INDICATED, HOWEVER THIS SHALL BE

E = 674105.138
FRW
EUD EUD EUD EUD

WETFIW
N = 2758526.121
EUD
EUD EUD VERIFIED AT SITE PRIOR TO THE CONSTRUCTION.
EUD N = 2758526.121 N = 2758627.180
EUD
EUD EUD EUD EUD EUD
8. FOR EXISTING UTILITY LEGEND, REFER TO KEY PLAN DRAWING
FFC-4500001708-00000-Z3-DD-M-FF-M10-1-001.
9. FIRE HYDRANTS SHALL BE PROVIDED WITH FIRE HOSE HOUSES.
E = 673856.458
EUD

400x250 TEE

TEW
EUD
EUD
LEGEND (LAYOUT)

EUD
EUD FRW FRW FRW FRW FRW FRW
TELCOM

FRW FRW FRW FRW FRW FRW EUD FRW FRW FRW FRW FRW FRW FRW FRW FRW FRW FRW FRW FRW FRW

E = 673789.209 N = 2758479.482 EUD


PROPOSED 160mmOD HDPE FIRE NETWORK
EU

EUD
PB

EUD EUD
D

FRW
EUD
PROPOSED 200mmOD HDPE FIRE NETWORK
N = 2758430.697 E = 674096.898
EUD
EUD

WETFIW
EUD
EUD PROPOSED 250mmOD HDPE FIRE NETWORK
N = 2758618.859
EUD
E = 673863.237 PROPOSED 315mm OD HDPE FIRE NETWORK

BLV
EUD
E = 673794.885
EUD EUD EUD EUD EUD EUD EUD EUD
WETIRW

FRW
E = 673784.291 PROPOSED 400mmOD HDPE FIRE NETWORK
EUD

N = 2758475.956

TEW
EUD

N = 2758434.167
TELCOM

EUD
BLV
PROPOSED PIPE REDUCER
N = 2758427.689 BLV BLV BLV
BLV 400mmOD HDPE PROPOSED BUTTERFLY VALVE CHAMBER

FRW
BLV BLV
WO

EUD
PROPOSED WASHOUT VALVE CHAMBER

WETFIW
BLV
AV
FRW
EUD
WETIRW

PROPOSED AIR RELEASE VALVE CHAMBER


TELCOM
EUD

TEW

FH EXISTING FIRE HYDRANT


FH
FRW

PROPOSED FIRE HYDRANT WITH


ISOLATION VALVE

EUD
400x200 TEE

SEE DWG FFC-4500001708-00000-Z3-DD-M-FP-M10-1-013


PROPOSED ROAD CROSSING DUCT
WETFIW

E = 673791.689
TELCOM
EUD

(HORIZONTAL DRILLING METHOD)


FRW

E = 673859.825 400x160 TEE


EUD

TEW
WETIRW

N = 2758426.521 N = 2758473.870 E = 674100.473 PROPOSED END CAP


LEGEND (PROFILE)
SEE DWG FFC-4500001708-00000-Z3-DD-M-FP-M10-1-010

N = 2758621.015
FRW

FINISHED GROUND LEVEL

EUD
PROPOSED FIRE NETWORK LINE
TELCOM
EUD

FRW
EUD

TEW

PROPOSED BUTTERFLY VALVE CHAMBER


WETFIW

TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM
250mmOD
WETIRW

PROPOSED WASHOUT VALVE CHAMBER


WETSAN

TELCOM
FRW

EUD
PROPOSED AIR RELEASE VALVE CHAMBER
PROPOSED ROAD CROSSING DUCT
TELCOM

(HORIZONTAL DRILLING METHOD)


EUD
EUD

TEW
FRW

TELEPHONE CABLES ELECTRICAL CABLES


WETFIW

ARAMCO PIPELINE SEWER PIPELINE


HDPE

FOR CONTINUATION
TELCOM
WETIRW

WATER PIPELINE OPTICAL FIBER CABLES

EUD
IRRIGATION PIPELINE

MATCH LINE
FRW

WETSAN
TEW
EUD

FOR CONTINUATION
FRW

N
TELCOM

KEYPLAN
MATCH LINE

TELCOM
WETFIW
EUD
EUD
EUD

EUD
WETIRW

FRW

Z4
WETSAN
TEW
EUD

TELCOM

Z1
FRW

TELCOM
31.07.2021 Z5

EUD
EUD

WETFIW
EUD
EUD

FRW
WETIRW

Z5 Z2
WETSAN
TELCOM

TEW

16
15 44

TELCOM
FRW

43 47
14
42 46
13
45
Z6 10 12

EUD
11
EUD

09 35
EUD
EUD

07
08 36
06 38
WETFIW

05 37 40
FRW

39 41
04 Z3
MATCH LINE 01
03 18
20
TELCOM

17
WETIRW

02 22 26
19 30
1 25
FOR CONTINUATION 2
TEW

24 29
WETSAN

TELCOM
28 33
23

SEE DWG FFC-4500001708-00000-Z3-DD-M-FP-M10-1-036 27 3 2


FRW

31 34

LAYOUT PLAN
EUD
EUD
EUD

FRW

EUD SCALE - 1:500


WETFIW
TELCOM

EUD EUD EUD EUD


EUD

TELCOM
TEW
WETIRW

EUD REVISIONS:
TELCOM
WETSAN
FRW

EUD

P01 25/07/2021 COMMENTS INCORPORATED AJ


P00 30/06/2021 ISSUED FOR APPROVAL AJ
NO. DATE DESCRIPTION APPROVED

MAIN CONSULTANT:

CLIENT:

CONTRACTOR:

SUB-CONSULTANT:

Suite 1807, Damac Executive Heights


P.O.Box 80968
Barsha Heights, Dubai, UAE
Tel : +971 4 364 9235 Fax:+ 971 4 364 9225
Mail: dubai@jainconsultants.com

PROJECT NAME:

KING KHALID INTERNATIONAL AIRPORT


KSA

DRAWING TITLE:

INFRA FIRE FIGHTING NETWORK ZONE 3


SHEET 11 OF 47

JOB NO. PAPER SIZE DRAWN CHECKED


A0 AS MM
SCALE DESIGNED APPROVED
DRAWING NO. AS SHOWN HK AJ
FFC-4500001708-00000-Z3-DD-M-FP-M10-1-012
ZONE-3 FF STA : 3350.000 STA TO 3750.000 PROFILE VIEW
STATUS DATE REVISION
SCALE - H=1:500, V=1:50
DETAILED DESIGN 30/06/2021 P01
GENERAL NOTES
EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD
EUD EUD TELCOM TELCOM TELCOM 1. ALL DIMENSIONS ARE IN METRES UNLESS OTHERWISE STATED.
TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM
TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM TELCOM

TEW
EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD

PB

PB
EUD

PB

PB
2. DO NOT SCALE FROM THIS DRAWING. ONLY WRITTEN DIMENSIONS ARE
TO BE FOLLOWED.
.3 B
E
CO
T
U
C
V
N
H
T
E
L
R
P
W
O
T
R
S
GE
O
S
IP
O
IFR
S
E
K
D

WETIRW
P
RO
H
T
WE
C E
T
D
I STEEL SLEEVES.
4. PROPOSED FIRE NETWORK PIPE CROSSING THE EXISTING
N CARRIAGEWAY SHOULD BE LAID WITH THE ROAD CROSSING DUCT
(HORIZONTAL DRILLING METHOD).
5. FOR STANDARD DETAILS, REFER TO DRAWINGS

TEW
FFC-4500001708-00000-Z0-DD-M-FF-M10-0-001 TO
FFC-4500001708-00000-Z0-DD-M-FF-M10-0-013.
6. THE PROPOSED NETWORK SHALL BE LAID 500mm FOR HORIZONTAL
CLEARANCE AND 300mm FOR VERTICAL CLEARANCE WITH EXISTING

WETIRW
UTILITIES. IN ANY CASE WHERE THE MINIMUM VERTICAL CLEARANCE

N = 2758877.329
CAN'T ABLE TO ACHIEVE PROPOSED PIPE SHALL BE PROTECTED WITH

E = 674526.605
CONCRETE ENCASEMENT.

TEW
7. ALL EXISTING UTILITY LEVELS ARE INDICATED, HOWEVER THIS SHALL BE
VERIFIED AT SITE PRIOR TO THE CONSTRUCTION.
EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD
8. FOR EXISTING UTILITY LEGEND, REFER TO KEY PLAN DRAWING
EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD FFC-4500001708-00000-Z3-DD-M-FF-M10-1-001.
EUD 9. FIRE HYDRANTS SHALL BE PROVIDED WITH FIRE HOSE HOUSES.

WETIRWTEW
EUD FRW LEGEND (LAYOUT)
E = 674268.814
FRW FRW
FRW FRW FRW FRW
FRW FRW FRW FRW
FRW FRW FRW FRW
FRW FRW FRW FRW FRW
FRW FRW FRW FRW
FRW FRW FRW
FRW FRW FRW
PROPOSED 160mmOD HDPE FIRE NETWORK
EUD E = 674483.640
E = 674183.480 N = 2758723.889 PROPOSED 200mmOD HDPE FIRE NETWORK
EUD
N = 2758851.755 PROPOSED 250mmOD HDPE FIRE NETWORK
EUD EUD EUD EUD EUD N = 2758671.753
EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD EUD PROPOSED 315mm OD HDPE FIRE NETWORK
AV PROPOSED 400mmOD HDPE FIRE NETWORK
WO 400mmOD HDPE

WETIRW
PROPOSED PIPE REDUCER
BLV

TEW
PROPOSED BUTTERFLY VALVE CHAMBER
WO
PROPOSED WASHOUT VALVE CHAMBER
AV
PROPOSED AIR RELEASE VALVE CHAMBER
FH

WETIRW
EXISTING FIRE HYDRANT

TEW
FH PROPOSED FIRE HYDRANT WITH
ISOLATION VALVE
SEE DWG FFC-4500001708-00000-Z3-DD-M-FP-M10-1-012

SEE DWG FFC-4500001708-00000-Z3-DD-M-FP-M10-1-014


PROPOSED ROAD CROSSING DUCT
(HORIZONTAL DRILLING METHOD)

PROPOSED END CAP

TEW
LEGEND (PROFILE)

WETIRW
FINISHED GROUND LEVEL
PROPOSED FIRE NETWORK LINE
PROPOSED BUTTERFLY VALVE CHAMBER

You might also like