Professional Documents
Culture Documents
4 Piping Interview Questionnaire
4 Piping Interview Questionnaire
PIPING GUIDE
Sr.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
Standard
ANSI B18.2
ANSI B16.3
ANSI B16.4
ANSI B16.9
ANSI B16.11
ANSI B16.25
ANSI B16.28
MSS-SP-43
MSS-SP-83
API 605
ANSI B16.1
ANSI B16.5
ANSI B16.47
ANSI B16.20
ANSI B16.21
API 601
API 5L
ANSI B16.10
ANSI B36.19
ANSI B16.10
ANSI B16.34
Description
Square and hexagola head bolts and nuts
Malleable iron threaded fittings
Cast iron threaded fittings.
Steel buttwelding fittings
Forged steel socketwelding and threaded fittings
Buttwelding ends
Short elbow radius and returns
Stainless steel buttweld fittings
Pipe Unions
Large diameter carbon steel flanges
Cast iron pipe flanges and flanged fittings
Steel pipe flanges and flanged fittings
Large diameter steel pipe flanges and flanged fitts.
Ring joint gaskets and grooves for pipe flanges
Non metallic gaskets for pipe flanges
Metallic gasket for refinery piping.
Specification for line pipe.
Welded and seamless wrought steel pipes
Welded and seamless austenitic stainless steel pipe
Face to face and end to end dimensions of valves
Steel valves, flanged and buttwelding ends.
MILIND SATPUTE
PIPING GUIDE
TOWERS
1
What are crude oil ranges?
Ans : Crude oil BP Range: 100F-1400F, lightest material: Butene below
100F, Heavier materials- upto 800F, Residue above 800F.
2
What is batch shell process?
Ans : feed, heat,condense,heat more,condense, low quality.
3
What are types of towers?
Ans : Stripper, Vacuum tower, trayed, packed towers.
4
What is chimney tray?
Ans : Its a solid plate with central chimney section, used at drawoff
sections of the tower.
5
What factors to consider while setting tower elevation?
Ans : NPSH, Operator access, Maintenance access, Minimum clearance,
reboiler type , common area, type of support, Tower dimensions, type of
head, bottom outlet size, foundation details, minimum clearances.
6
How to located tower maintenance access nozzles ?
Ans : At bottom, top and intermediate sections of tower, must not be at
the downcomer section of tower and in front of internal piping.
7
How to located feed nozzle ?
Ans : Must be oriented in specific area of tray by means of internal
piping.
8
How to located temperature and pressure instruments ?
Ans : Temperature in liquid space, at downcomer side and pressure in
vapor space, in area except downcomer sector.