You are on page 1of 10

ANNAMACHARYA INSTITUTE OF TECHNOLOGY AND SCIENCES, RAJAMPET

DEPARTMENT OF MECHANICAL ENGINEERING

1.

CHECK THE POWER


SUPPLY

2.

CHECK THE
VOLTMETER
READING

3.

CHECK THE
AMMETER READING
CHECK THE WATER
LEVEL

4.
5.
6.

7.

6.

CHECK THE HEATER


WORKING
CHECK THE
THERMOCOUPLES
READING

CHECK THE
EQUIPMENT IS
CLEAN FROM DUST
Remarks

HEAT TRANSFER LAB

UNSTEADY STATE

STEFAN BOLTZMANN
CONSTANT

CRITICAL HEAT FLUX

EMISSIVITY OF GRAY BODY

HEAT TRANSFER IN
NATURAL CONVECTION

THERMAL CONDUCTIVITY
OF INSULATING POWDER

THERMAL CONDUCTIVITY
OF METAL BAR

EXP NAME

S.NO

DATE

HEAT EXCHANGER

HEAT TRANSFER IN FORCED CONVECTION

TWO PHASE HEAT TRANSFER

DROPWISE AND FILM WISE CONDENSATION

COMPOSITEWALL APPRATUS

PARALLEL FLOW & COUNTER FLOW

HEAT PIPE APPRATUS

PIN-FIN APPRATUS

HEAT FLOW

N-No

THROUGH LAGGED PIPE

Y- Yes

EXP NAME

S.NO

Signature of Lab Technician


Signature of Lab Incharge

Signature of Faculty

NR- Not required

DATE

1.

CHECK THE POWER


SUPPLY

2.

CHECK THE
VOLTMETER
READING

3.

CHECK THE
AMMETER READING
CHECK THE WATER
LEVEL

4.
5.
6.

7.

6.

CHECK THE HEATER


WORKING
CHECK THE
THERMOCOUPLES
READING

CHECK THE
EQUIPMENT IS
CLEAN FROM DUST
CHECK THE
MANOMETER
READING
Remarks

ANNAMACHARYA INSTITUTE OF TECHNOLOGY AND SCIENCES,


RAJAMPET
DEPARTMENT OF MECHANICAL ENGINEERING

HEAT TRANSFER LAB


LIST OF EXPERIMENTS
CYCLE-I
1. THERMAL CONDUCTIVITY OF METAL BAR
2. THERMAL CONDUCTIVITY OF INSULATING POWDER
3. HEAT TRANSFER IN NATURAL CONVECTION
4. EMISSIVISTY OF GRAY BODY

5. STEFAN BOLTZMAN CONSTANT


6. CRITICAL HEAT FLUX
7. UNSTEADY STATE

CYCLE-II

8. HEAT FLOW THROUGH LAGGED PIPE


9. PIN-FIN APPRATUS
10. HEAT PIPE APPRATUS

11. PARALLEL FLOW AND COUNTER FLOW HEAT EXCHANGER


12. COMPOSITE WALL APPRATUS
13. DROPWISE AND FILM WISE CONDENSATION
14. HEAT TRANSFER IN FORCED CONVECTION
15. TWO PHASE HEAT TRANSFER

Exp NO : 1 THERMAL CONDUCTIVITY OF METAL BAR


S.NO

CURRENT

VOLTAGE

WATTS

METAL BAR THERMO


Insulating
COUPLE READING (C) shell temp(C)

T1

T2

T3

T4

T5

T6

T7

T8

Cooling
water
temp(C)

T9

T10

T11

Mass
flow
rate
(cc/min)

Exp NO : 2 THERMAL CONDUCTIVITY OF INSULATING POWDER


S.NO

CURRENT

VOLTAGE

WATTS

INNER SURFACE
TEMP (C)

T1

Exp NO : 3
S.NO

CURRENT

T2

T3

T4

OUTER SURFACE
TEMP (C)

T5

T6

T7

T8

T9

T10

HEAT TRANSFER IN NATURAL CONVECTION

VOLTAGE

WATTS

TEMP ON THE SURFACE


OF THE PIPE (C)

Ambient
Temp
(C)

T1

Exp NO : 4
S.NO

T11

PLATE

T2

T3

T4

T5

T6

VOLTMETER

SURFACE TEMP
AMMETER

(C)

TEST PLATE
BLACK PLATE

STEFAN BOLTZMAN CONSTANT

THERMO COUPLE NUMBER


1
2
3
4

T8

EMISSIVISTY OF GRAY BODY


INPUT

Exp NO : 5

T7

TEMPERATURE (C)

T12

TIME (S)

TEMPERATURE (C)
0

Exp NO : 6
CRITICAL
S.NO

5
10

HEAT FLUX

15

BULK TEMP OF
20
WATER
(C)

AMMETER VOLTMETER
READING READING

25
30
35

Exp NO : 7
S.NO

40

Unsteady state

45
HEATING PROCESS

COOLING PROCESS

TIME (Sec) 50

TIME (Sec)

55
60

TEMP (C)

TEMP (C)

Exp NO : 8
S.NO

HEAT FLOW THROUGH LAGGED PIPE

VOLTMETER
(V)

AMMETER
( I)

THERMOCOUPLE READING (C)


T1

Exp NO : 9
S.NO

HEAT INPUT
V

PRESSURE
DROP
cm Of Hg

Exp NO : 10

T2

T3

T4

T5

T6

PIN FIN
TEMPERATURE READING (C)
T1

T2

T3

T4

T5

HEAT PIPE APPRATUS

1) HEAT SINK WATER TEMPERATURE


TIME
(Min)
5

S.S PIPE
HEAT SINK

COPPER PIPE
HEAT SINK

HEAT PIPE
HEAT SINK

10
15
20
25

2) LONGITUDINAL TEMPERATURE DISTRIBUTION


S.S PIPE

COPPER PIPE

HEAT PIPE

T6

ExpNO:11

PARALLEL FLOW AND COUNTER FLOW HEAT


EXCHANGER

i)

Parallel flow heat exchanger


HOT WATER SIDE

FLOWRATE
(ml/s)

INLET
TEMP (C)

OUTLET
TEMP (C)

T1

ii)

COLD WATER SIDE


FLOWRATE
(ml/s)

INLET
(C)
T3

T2

TEMP OUTLET
TEMP(C)
T4

Counter flow heat exchanger


HOT WATER SIDE

FLOWRATE
(ml/s)

INLET
TEMP (C)
T1

COLD WATER SIDE

OUTLET
TEMP (C)

FLOWRATE
(ml/s)

INLET
(C)
T3

T2

Exp NO : 12

TEMP OUTLET
TEMP(C)

COMPOSITE WALL APPRATUS

S.NO

READING

VOLTMETER (V)

AMMETER (I)

SET-1

T4

TEMPERATURE
READING (C)
T1
T2
T3
T4
T5
T6
T7
T8

Exp NO : 13

DROP AND FILMWISE CONDENSATION

S.NO

STEAM PRESSURE (Kg/cm2)


WATER FLOW RATE (LPH)
STEAM TEMPERATURE (C) T1
DROP CONDENSER SURFACE TEMP (C) T2
FILM CONDENSER SURFACE TEMP (C) T3
WATER INLET TEMP (C) T4
WATER OUTLET TEMP
CONDENSER (C) T5

FROM DROPWISE

WATER OUTLET TEMP


CONDENSER (C) T6

FROM FILMWISE

Exp NO : 14

HEAT TRANSFER IN FORCED CONVECTION

S.NO

HEAT
INPUT
V

AIR TEMP (C)


I

INLET

OUTLET

T1

T7

ORIFICE
TEMP
cm Of Hg

TUBE SURFACE
READING (C)
T2

T3

T4

Exp NO : 15 TWO PHASE HEAT TRANSFER

TEMPERATURE
T5

T6