You are on page 1of 2

HARDNESS TEST INSPECTION REPORT

PROJECT
CLIENT

EQUIPMENT NO
DATE OF INSPECTION
REPORT NO

PAGE NO

DRAWING NO.

WELD

:
:

TERENGGANU CRUDE OIL TERMINAL (TCOT)SEPARATION UPGRADE PACKAGE


RANHILL E & C SDN BHD
V-220C / GAS OIL WATER SEPARATOR
26/11/2015
MSET/M2-253/V-220C /HDT/002
1 OF 1
MSET/M2-253/V-220C/01 REV.G

BASE METAL
AVG

JOINT NO

LIFTING LUG PAD 1

126

139

120 146

141

134

LIFTING LUG PAD 2

143

135

164 134

134

142

LIFTING LUG PAD 3

103

111

140 114

134

120

LIFTING LUG PAD 4

117

110

129 114

125

119

1. EQUIPMENT USED : PROCEQ HARDNESS TESTER


2.READING TAKEN IN HV VALUE. ( MAX 248 HV )

Prepared By :

MSET QC INSPECTOR

Reviewed By :

AUTHORIZE INSPECTOR

Witness By :

CLIENT REP.