You are on page 1of 2

Material Properties

Fcu
Fy
w(con)
Density of liquid
Permissible Direct tension
Permissible Bending tension
Tank Dimensions
Length
Width
Height
Free Board
Tank Capacity
Top Thickness of Vertical wall
Bot. Thickness of Vertical wall
Centre to centre dimension

25
415
24
10
1300
1800

N/mm2
N/mm2
KN/mm3
KN/mm3
KN/mm2
KN/mm2
12
6
2.3
0.2
151.2
180
180
12.18

see page 701, A.K, jain


1.7 Mpa
m
m
m
m
m3(kilo litre)
mm
mm
m

Moments(See page 714, A.K. Jain)


L/H
Max. BM in vertical direction at bottom of wall
BM at mid height of wall
Max. BM in horizontal direction at ends of wall
BM at mid height of wall

5.8
11.66886
0.46305
7.59402
5.09355

Thickness of wall required at bottom


Thickness of wall required at top

202.9389 mm
163.7145 mm

KNm
KNm
KNm
KNm
change thickness
thickness is ok

Shear force
Max. shear force @ midpoint of bottom edge of wall
Max. shear force @ midpoint/top of vertical edge of wall
Vertical reinforcement in wall
1) Base of wall
Permissible stress in concrete in bending compression

19.845 KN/m
17.9046 KN/m

9 Mpa

change thickness
ok

Permissible stress in steel on liquid retaining face


modular ratio
N
j
Ast
Provide
T
2) Quarter height of wall
BM
D
d
Ast
Min. steel(0.24%)
Provide

0.9261
180
145
48.9417360285
432

150 Mpa
10.37037
0.383562
0.872146
615.1484 mm2/m
10 @
127.6762 mm c/c

KNm/m
mm
mm
mm2/m
mm2/m

10 @

181.8051 mm c/c

10 @

225.6891 mm c/c

10 @

151.4857 mm c/c

Horizontal reinforcement in wall


1) Near top of wall at corner
Ld
M

e
Ast
Min steel
Provide

500
7.59402
17.9046
0.424137931

351.4836420927 mm2/m
348 mm2/m
T

2) Base Slab
M
T
e
Ast
Provide

mm
KNm/m
KN/m
m

11.66886 KNm/m
19.845 KN/m
588 mm
518.4634066587 mm2/m
T

You might also like