Professional Documents
Culture Documents
www.NOV.com/GrantPrideco
(in)
(in)
(in)
(in)
(in)
(in)
80 % Inspection Class
Nominal Weight Designation
15.50
(ft) 31.8
Drill Pipe Approximate Length
(in) 3/32 Raised
SmoothEdge Height
(psi) 120,000
Tool Joint SMYS
Upset Type
EU
(in) 3.875
Max Upset OD (DTE)
Friction Factor
1.0
3.500
0.449
S-135
Range2
XT39
4.938
2.500
10
15
Drill-Pipe Length
Best Estimates
(without Coating)
80 % Inspection Class
Applied Make-up
Torque
Max Tension
Operational
Torque (ft-lbs)
(lbs)
(ft-lbs)
Maximum MUT
23,900
Minimum MUT
19,900
Tension Only
Combined Loading
Tension Only
Combined Loading
0
21,100
451,100
310,300
0
16,500
451,100
370,800
Fluid Displacement
Fluid Displacement
Fluid Capacity
Fluid Capacity
Drift Size
17.89
0.27
(Bbls/ft) 0.0065
(gal/ft) 0.26
(Bbls/ft) 0.0063
(in) 2.375
XT39
4.938
Applied Make-up
Tension at Shoulder
Torque
Separation
(ft-lbs)
23,900
19,900
(ft-lbs)
(lbs)
Tensile Limited
720,700
SmoothEdge Height
(in)
(lbs)
3/32 Raised
5.125
909,200
17.28
0.26
0.0063
0.27
0.0065
(lbs/ft)
0.26
0.0062
(lbs)
OD X
(in)
2.500
Tension at Connection
Yield
(lbs)
646,800
753,900
ID
(in)
120,000
(psi)
(in)
(in)
5.024
4.653
4.653
39,800
753,900
(least accurate)
(gal/ft)
Nominal
(with Coating)
Connection Performance
Maximum Make-up Torque
Minimum Make-up Torque
Range2
(in)
4.938
746,000
4.653
510,100
Nominal
Assumed Slip Length
Transverse Load Factor (K)
(lbs)
(in)
453,100
(ft-lbs)
(ft-lbs)
(psi)
(psi)
(in)
(in)
(in)
(in^2)
(in^2)
(in^2)
(in^3)
(in^3)
3.5 (in) OD
80 % Inspection Class
356,500
(lbs)
S-135 )
Note: Slip Crushing: Slip crushing load is calculated with the Spiri-Reinhold equation from Why Does Drill Pipe
Fail in the Slip Area World Oil, 1959 for the slip length and transverse load factor shown and is for reference
only. Slip crushing is dependent on the slip design and condition, coefficient of friction, loading conditions, time in
slips, drill pipe OD and wall variation, and other factors. Consult with the slip manufacturer for additional
information.
16.5
4.2
Nominal
Pipe Tensile Strength
Pipe Torsional Strength
TJ/PipeBody Torsional Ratio
80% Pipe Torsional Strength
Burst
Collapse
Pipe OD
Wall Thickness
Nominal Pipe ID
Cross Sectional Area of Pipe Body
Cross Sectional Area of OD
Cross Sectional Area of ID
Section Modulus
Polar Section Modulus
(in)
Note: Elevator capacity based on assumed Elevator Bore, no wear factor, and contact stress of 110,100psi.
Note: A raised elevator OD increases elevator capacity without affecting make-up torque.
3.969
4.786
618,600
5.125
581,000
38,000
1.05
30,400
30,308
30,194
3.500
0.449
2.602
4.304
9.621
5.317
2.923
5.847
3.5 (in) OD
80 % Inspection Class
451,100
29,100
1.37
23,300
27,710
26,049
3.320
0.359
2.602
3.342
8.659
5.317
2.239
4.477
S-135 )
Note: The technical information contained herein, including the product performance sheet and other attached documents, is for reference only and should not be construed as a recommendation. The user is fully
responsible for the accuracy and suitability of use of the technical information. NOV Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied
warranty is intended. Drill pipe assembly properties are calculated based on uniform OD and wall thickness. No safety factor is applied. The information provided for various inspection classes and for various wear
conditions (remaining body wall) is for information only and does not represent or imply acceptable operating limits. It is the responsibility of the customer and the end user to determine the appropriate performance
ratings, acceptable use of the product, maintain safe operational practices, and to apply a prudent safety factor suitable for the application. For API connections that have different pin and box IDs, tool joint ID refers to
the pin ID. Per Chapter B, Section 4 VII of the IADC drilling manual, it is recommended that drilling torque should not exceed 80% of MUT.
www.NOV.com/GrantPrideco/CustomerFeedback
XT39
80 % Inspection Class
Tool Joint OD
(in)
4.938
Tool Joint ID
Pipe Body OD
(in)
3.5
(in)
0
1,100
2,200
3,300
4,400
5,600
6,700
7,800
8,900
10,000
11,100
12,200
13,300
14,400
15,500
16,700
17,800
18,900
20,000
21,100
(lbs)
451,100
450,800
449,800
448,200
445,900
442,700
439,000
434,600
429,400
423,600
416,900
409,400
401,100
391,800
381,600
369,200
356,600
342,700
327,300
310,300
(ft-lbs)
Operationa Assembly
l Torque
Max Tension
(ft-lbs)
(lbs)
Pipe Body
Max Tension
(lbs)
(lbs)
(lbs)
451,100
451,100
720,700
451,100
646,800
450,800
646,800
900
450,900
450,900
720,700
646,800
1,700
450,300
450,300
720,700
720,700
448,200
646,800
2,600
449,300
449,300
445,900
646,800
3,500
447,800
447,800
720,700
442,700
646,800
4,400
445,900
445,900
720,700
439,000
646,800
5,200
443,800
443,800
720,700
646,800
6,100
441,100
441,100
720,700
646,800
7,000
437,800
437,800
720,700
646,800
7,800
434,600
434,600
720,700
720,700
434,600
429,400
423,600
416,900
646,800
8,700
430,400
430,400
409,400
646,800
9,600
425,800
425,800
720,700
401,100
646,800
10,500
420,600
420,600
720,700
391,800
646,800
11,300
415,600
415,600
720,700
646,800
12,200
409,400
409,400
720,700
646,800
13,100
402,700
402,700
720,700
396,200
396,200
720,700
720,700
381,600
369,200
356,600
13,900
646,800
342,700
646,800
14,800
388,200
388,200
327,300
646,800
15,700
379,600
379,600
720,700
310,300
646,800
16,500
370,800
370,800
720,700
(ft-lbs)
Connection
Max Tension
449,800
S-135
Connection Max
Pipe Body
Max Tension Tension
(lbs)
2.500
Connection
Make-up Torque Range
Make-up Torque
(ft-lbs)
Min MUT
Max MUT
19,900
20,300
20,800
21,200
21,700
22,100
22,600
23,000
23,500
23,900
Connection Max
Tension
(lbs)
720,700
735,200
753,300
740,600
723,200
709,300
691,900
678,000
660,700
646,800
Note: Recommended MUT should always be used when possible. If not possible, MUT should be as close to Recommended MUT as possible.
Note: The technical information contained herein, including the product performance sheet and other attached documents, is for reference only and should not be construed as a recommendation. The user is fully responsible for the accuracy and
suitability of use of the technical information. NOV Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended. Drill pipe assembly properties are calculated
based on uniform OD and wall thickness. No safety factor is applied. The information provided for various inspection classes and for various wear conditions (remaining body wall) is for information only and does not represent or imply acceptable
operating limits. It is the responsibility of the customer and the end user to determine the appropriate performance ratings, acceptable use of the product, maintain safe operational practices, and to apply a prudent safety factor suitable for the
application. For API connections that have different pin and box IDs, tool joint ID refers to the pin ID. Per Chapter B, Section 4 VII of the IADC drilling manual, it is recommended that drilling torque should not exceed 80% of MUT.
02-03-2014
XT39
Tool Joint OD
Connection
Wear
Tool
Joint OD
New OD
(in)
4.938
4.912
4.886
4.86
4.834
4.808
4.782
4.756
4.731
4.705
4.679
4.653
Worn OD
(in)
4.938
Tool Joint ID
(in)
2.500
Connection Max
Tension
Connection
Torsional
Strength (ft-lbs)
Max
MUT
39,800
39,000
38,100
37,300
36,500
35,700
34,800
34,000
33,300
32,500
31,700
30,900
23,900
23,400
22,900
22,400
21,900
21,400
20,900
20,400
20,000
19,500
19,000
18,600
(ft-lbs)
Connection Max
Tension
Min MUT
(lbs)
(lbs)
(ft-lbs)
646,800
661,100
675,200
689,100
702,900
708,000
698,500
688,200
675,000
640,600
605,800
575,100
19,900
720,700
19,500
709,500
19,100
698,300
18,700
687,000
18,200
672,100
17,800
652,900
17,400
621,400
17,000
590,700
16,600
561,400
16,200
532,200
15,900
507,000
15,500
479,200
Pipe Body
Combined Loading Table (Torque-Tension)
Pipe Body
Pipe Body OD
80 % Inspection Class
(in)
3.5
S-135
2,600
5,300
7,900
10,600
13,200
15,900
18,500
21,100
23,800
26,400
29,000
449,300
443,600
434,100
420,000
401,900
377,600
347,900
310,200
258,900
188,600
29,700
(ft-lbs)
Note: The technical information contained herein, including the product performance sheet and other attached documents, is for reference only and should not be construed as a recommendation. The user is fully responsible for the accuracy and
suitability of use of the technical information. NOV Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended. Drill pipe assembly properties are calculated
based on uniform OD and wall thickness. No safety factor is applied. The information provided for various inspection classes and for various wear conditions (remaining body wall) is for information only and does not represent or imply acceptable
operating limits. It is the responsibility of the customer and the end user to determine the appropriate performance ratings, acceptable use of the product, maintain safe operational practices, and to apply a prudent safety factor suitable for the
application. For API connections that have different pin and box IDs, tool joint ID refers to the pin ID. Per Chapter B, Section 4 VII of the IADC drilling manual, it is recommended that drilling torque should not exceed 80% of MUT.
02-03-2014