Results and conclusion

From the above table the peak stress measured was observed at the corners and were the stress
Gradient occurs in a small, localized area of a structure; therefore the peak stress at the localized
Area shall be ignored.
The maximum stress measured apart from corners was 236MPa, which is less than the nominal
Stress of 310Mpa, and the maximum deformation measured was 0.42mm which is less than the bolt
Hole clearance 0.5mm, therefore the design is safe.