BEAM DESIGN FORCES

Beam Name: GBX2


Location: Basement, Interior Girders in the X direction

Beam L/C Dist m Fx kN Fy kN Fz kN Mx kNm My kNm Mz kNm


2467 5 1.2D + 1.6L 0 -124.119 318.35 -0.136 3.012 0.133 641.881
0.278 -124.119 316.062 -0.136 3.012 0.095 553.769

Max Pos V = 324.851 Max Neg M = 685.64 Beam Length =


Max Neg V = -324.851 Max Pos M = -335.676

Beam L/C
Design V = 324.851 2856 5 1.2D + 1.6L
V at "d" = 316.976
V at "2h" = 298.7

Beam Name: GBZ1


Location: Basement, Exterior Girders in the Z direction

Beam L/C Dist m Fx kN Fy kN Fz kN Mx kNm My kNm Mz kNm


2512 5 1.2D + 1.6L 0 -46.84 71.946 -0.435 0.749 1.689 101.451
0.667 -46.84 65.689 -0.435 0.749 1.398 55.436

Max Pos V = 87.663 Max Neg M = 189.986 Beam Length =


Max Neg V = -87.659 Max Pos M = -71.511

Beam L/C
Design V = 87.663 2552 9 1.2D + 0.5L - 1.0EQZ
V at "d" = 81.94
V at "2h" = 71.792
Beam L/C
2467 5 1.2D + 1.6L
2467 5 1.2D + 1.6L

3.333 m

Beam L/C
2512 5 1.2D + 1.6L
2512 5 1.2D + 1.6L

8m